ASL10 - Astrodyne

ASL10
1 0 W U l t r a m i n i a t ure Open Frame Global Switching Power Supplies
series
Universal 90-264VAC Input
Molex Mini Connector I/O
Regulated Outputs
3000V Isolation
Single Output from 3.3 to 24 VDC
2”W x 2.28”L x 0.883”H
Model Number
Output Voltage
Output Amps (max)
(pk)
ASL-0100
ASL-0101
ASL-0102
ASL-0103
ASL-0105
3.3 VDC
5 VDC
12 VDC
15VDC
24VDC
2.5A
2A
0.85A
0.67A
0.42A
3.3A
2.6A
1.2A
0.9A
0.6A
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
ASL10
1 0 W U l t r a m i n i a t ure Open Frame Global Switching Power Supplies
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ:
PHYSICAL SPECIFICATIONS
90-264 VAC
47-63 Hz
20A @ 100VAC Input *
40A @ 200VAC Input *
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation Line Regulation
Preset Accuracy
DC Voltage Adjust (typ)
Temperature Coefficient
Ripple/Noise
Over Voltage Protection
Over Temp. Protection
Short Circuit Protection
Hold Up Time
series
See Selection Chart
+/- 3% (20% to 100% Load)
Singles +/- 0.1~1%, typ
1%
+/- 6% of FS (Primary)
+/-0.03%/°C
100mV Pk-Pk, typ Clamp, 130-150% *
Latching, Cool and Repower
Continuous, self-recovering
20 mS, typ
Size
Construction
Weight
Connectors: Molex P/N:
2” x 2.28” x 0.883”
Open Frame
1.6oz (44g)
50-37-5033 (Input)
50-37-5023 (Output)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
EMI
MTBF
0 to +50°C(FL) See Derate
-25 to +71°C *
0 to + 95%, non-cond *
EN55022 Class A 180,000 Hrs
Mil Std 217, 25°C
OUTPUT DERATING CURVE
100
90
80
GENERAL SPECIFICATIONS
I/P-O/P:3000VAC
I/P-Ground: 2500VAC
O/P-Ground: 1000VAC
75%~78%, typ
100Khz, (fixed, typical)
UL60950-1 2nd ed./
C22.2 60950-1 2nd ed.
EN60950-1 2nd ed.
EN60601-1-2
IEC60950-1 2nd ed. All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
Load (%)
Isolation
Efficiency
Switching Frequency
Safety UL/cUL: UL-EU:
CE: CB: 70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
Ambient Temperature °C
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
: 8 O W U D P L Q L D W XUH2SHQ)UDPH*OREDO6ZLWFKLQJ3RZHU6XSSOLHV

ASL10
1 0 W U l t r a m i n i a t ure Open Frame Global Switching Power Supplies
series
MECHANICAL DIMENSIONS
2.00in
50.8mm
.11in
2.79mm
.11in
2.79mm
1.78in
45.21mm
[ .833in
.68in]
21.15mm
max
17.27mm
1
J1 (AC lnput )
Pin 1
Pin 3
2.28in
2.06in
57.91mm 52.32mm
T1
AC Neutral
AC Line
.17in
4.32mm
J2 (DC Output )
Pin 1
Pin 32
+Vout
Return
1
.54in
13.71mm
.70in
17.78mm
SIZE TOLERANCE :
.54in
13.72mm
.11in
2.79mm
0.3mm

WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458