ASL15 1 5 W U l t r a m i n i a t ure Open Frame Global Switching Power Supplies series Universal 90-264VAC Input Molex Mini Connector I/O Regulated Outputs 3000V Isolation Single Output from 3.3 to 24 VDC 3”W x 2.18”L x 0.93”H Model Number Output Voltage Output Amps (max) (pk) ASL-1500 ASL-1501 ASL-1502 ASL-1503 ASL-1505 3.3 VDC 5 VDC 12 VDC 15VDC 24VDC 3.5A 3A 1.25A 1A 0.63A 3.8A 3.6A 1.5A 1.25A 0.75A WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASL15 1 5 W U l t r a m i n i a t ure Open Frame Global Switching Power Supplies INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: PHYSICAL SPECIFICATIONS 90-264 VAC 47-63 Hz 20A @ 100VAC Input * 40A @ 200VAC Input * Size Construction Weight Connectors: Molex P/N: See Selection Chart +/- 3% (20% to 100% Load) Singles +/- 0.1~1%, typ 1% +/- 6% of FS (Primary) +/-0.03%/°C 100mV Pk-Pk, typ Clamp, 130-150% * Latching, Cool and Repower Continuous, self-recovering 20 mS, typ ENVIRONMENTAL SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage and Current Load Regulation Line Regulation Preset Accuracy DC Voltage Adjust (typ) Temperature Coefficient Ripple/Noise Over Voltage Protection Over Temp. Protection Short Circuit Protection Hold Up Time series 3” x 2.18” x 0.93” Open Frame 2.5oz (70g) 50-37-5043 (Input) 50-37-5043 (Output) Contact: 08-70-1040 Oper. Temperature Storage Temperature Relative Humidity EMI MTBF -10 to +50°C(FL) See Derate -25 to +71°C * 0 to + 95%, non-cond * EN55022 Class A 180,000 Hrs Mil Std 217, 25°C OUTPUT DERATING CURVE 100 90 GENERAL SPECIFICATIONS 80 I/P-O/P:3000VAC I/P-Ground: 2500VAC O/P-Ground: 1000VAC 75%~78%, typ 100Khz, (fixed, typical) UL60950-1 2nd ed./ C22.2 60950-1 2nd ed. EN60950-1 2nd ed. EN60601-1-2 IEC60950-1 2nd ed. All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Load (%) 70 Isolation Efficiency Switching Frequency Safety UL/cUL: UL-EU: CE: CB: 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 Ambient Temperature °C Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 A S L 1 5 series A S L 1 5 series 1 5 W U l t r a m i n iature Open Frame Global Switching Power Supplies 1 5 W U l t r a m i n i a t ure Open Frame Global Switching Power Supplies MECHANICAL DIMENSIONS MECHANICAL DIMENSIONS 0.12” Dia Mtg Hole ( 4 plcs) 0.15 0.93 0.85 max 3.0 15 Watt 0.15 2.18 2.10 max J1 (AC Input) Pin 1 Pin 2 Pin 3 Pin 4 AC Neutral N/C N/C AC Line J2 (DC Output) Pin 1 Pin 2 Pin 3 Pin 4 Com. Return Com. Return +Vout +Vout WWW.ASTRODYNE.COM WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458