ASL15 - Astrodyne

ASL15
1 5 W U l t r a m i n i a t ure Open Frame Global Switching Power Supplies
series
Universal 90-264VAC Input
Molex Mini Connector I/O
Regulated Outputs
3000V Isolation
Single Output from 3.3 to 24 VDC
3”W x 2.18”L x 0.93”H
Model Number
Output Voltage
Output Amps (max)
(pk)
ASL-1500
ASL-1501
ASL-1502
ASL-1503
ASL-1505
3.3 VDC
5 VDC
12 VDC
15VDC
24VDC
3.5A
3A
1.25A
1A
0.63A
3.8A
3.6A
1.5A
1.25A
0.75A
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
ASL15
1 5 W U l t r a m i n i a t ure Open Frame Global Switching Power Supplies
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ:
PHYSICAL SPECIFICATIONS
90-264 VAC
47-63 Hz
20A @ 100VAC Input *
40A @ 200VAC Input *
Size
Construction
Weight
Connectors: Molex P/N:
See Selection Chart
+/- 3% (20% to 100% Load)
Singles +/- 0.1~1%, typ
1%
+/- 6% of FS (Primary)
+/-0.03%/°C
100mV Pk-Pk, typ Clamp, 130-150% *
Latching, Cool and Repower
Continuous, self-recovering
20 mS, typ
ENVIRONMENTAL SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation Line Regulation
Preset Accuracy
DC Voltage Adjust (typ)
Temperature Coefficient
Ripple/Noise
Over Voltage Protection
Over Temp. Protection
Short Circuit Protection
Hold Up Time
series
3” x 2.18” x 0.93”
Open Frame
2.5oz (70g)
50-37-5043 (Input)
50-37-5043 (Output)
Contact: 08-70-1040
Oper. Temperature
Storage Temperature
Relative Humidity
EMI
MTBF
-10 to +50°C(FL) See Derate
-25 to +71°C *
0 to + 95%, non-cond *
EN55022 Class A 180,000 Hrs
Mil Std 217, 25°C
OUTPUT DERATING CURVE
100
90
GENERAL SPECIFICATIONS
80
I/P-O/P:3000VAC
I/P-Ground: 2500VAC
O/P-Ground: 1000VAC
75%~78%, typ
100Khz, (fixed, typical)
UL60950-1 2nd ed./
C22.2 60950-1 2nd ed.
EN60950-1 2nd ed.
EN60601-1-2
IEC60950-1 2nd ed. All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
Load (%)
70
Isolation
Efficiency
Switching Frequency
Safety UL/cUL: UL-EU:
CE: CB: 60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
Ambient Temperature °C
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
A S L 1 5 series
A S L 1 5 series
1 5 W U l t r a m i n iature Open Frame Global Switching Power Supplies
1 5 W U l t r a m i n i a t ure Open Frame Global Switching Power Supplies
MECHANICAL DIMENSIONS
MECHANICAL DIMENSIONS
0.12” Dia Mtg Hole ( 4 plcs)
0.15
0.93
0.85
max
3.0
15 Watt
0.15
2.18
2.10
max
J1 (AC Input)
Pin 1
Pin 2
Pin 3
Pin 4
AC Neutral
N/C
N/C
AC Line
J2 (DC Output)
Pin 1
Pin 2
Pin 3
Pin 4
Com. Return
Com. Return
+Vout
+Vout
WWW.ASTRODYNE.COM
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458