SPU12A series

SPU12A
1 0 - 1 5 Wa t t Wa l l mount Switching Power Supplies
series
90-264VAC Universal Input
3.3 Through 48VDC Single Outputs
2 Prong Plug-In Mains Connector
3000V Isolation
2.55”W x 2.16”L x1.34”H
Model Number
Output Watts
Output Voltage
Output Amps
SPU12A-101
SPU12A-102
SPU12A-103
SPU12A-104
SPU12A-105
SPU12A-106
SPU12A-107
SPU12A-108
SPU12A-109
SPU12A-110
SPU12A-111
10
10
10
12
15
15
15
15
15
15
15
3.3V
5V
6V
9V
12V
15V
18V
24V
30V
36V
48V
3.03
2.0A
1.66A
1.33A
1.25A
1.0A
0.83A
0.62A
0.5A
0.41A
0.31A
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
SPU12A
1 0 - 1 5 Wa t t Wa l l mount Switching Power Supplies
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Input Current
Inrush Current, typ (Cold Start)
Leakage Current
GENERAL SPECIFICATIONS
90-264 VAC (Universal)
47-63 Hz
Low Line (115VAC)
High Line (230VAC)
Low Line (115VAC)
High Line (230VAC)
0.75mA MAX. @ 240 VAC, FL
0.4A
0.3A
15A max.
30A max.
OUTPUT SPECIFICATIONS
Voltage and Current
Output Power Range
Load Regulation (FL, 230Vin)
Line Regulation (FL)
Transient Response
Temperature Coefficient
Ripple/Noise
Short Circuit Protection
Start Up / Hold Up Time
series
See Selection Charts
0 to FL Rating
+/- 7%, max. +/- 1%, max.
100Vin, FL to 1/2L
4mS
+/-0.04%/°C, typ
FL, 90Vin
1% Pk-Pk
Continuous, self-recovering *
100Vin, FL
2S max. / 5 mS min.
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
Input-Out Isolation
Isolation Resistance
Efficiency
Safety
3000 VAC
50 Mohm min.
(FL, 230Vin)
(c)UL60950 70%, typ
PHYSICAL SPECIFICATIONS
Size
Construction
Weight
2.55” x 2.16” x 1.34”
Wallmount Style
4oz (115g)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
EMC
MTBF
0 to +40°C (FL) *
50% Load @ 70°C
(See Derate Curve Next Page)
-40 to +85°C *
5% to 95%, non-cond *
110Vin:
FCC Part 15 Class B
220Vin:
CISPR-22 Class B
100,000 Hrs
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
SPU12A
1 0 - 1 5 Wa t t Wa l l mount Switching Power Supplies
series
MECHANICAL DIMENSIONS
Dimensions Are In mm.
DERATE CURVE
DC OUTPUT CONNECTIONS
Coaxial Plug:
-Vout
+Vout
5.5mm outer diameter
2.1mm inner diameter, female
11mm length, center “+”
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458