PMMK150-D M e d i c a l G r a d e 1 50 Watt with DIN Rail mount and PFC series 150 Watts Output Power Single and Dual Outputs Universal 90-264VAC Input 5VDC to 48VDC Outputs 5656VDC Input to Output Isolation Active Power Factor Correction 3.2”W x 5.5”L x 1.6”H Model Number Output Voltage Output Amps (max) Line Regulation (max) Ripple & Noise SINGLE OUTPUT PMMK150S-5D PMMK150S-12D PMMK150S-15D PMMK150S-24D PMMK150S-48D 5 VDC 12 VDC 15 VDC 24 VDC 48 VDC 30 12.5 10 6.3 3.2 ±1% ±1% ±1% ±1% ±1% 150mV pk-pk 150mV pk-pk 150mV pk-pk 150mV pk-pk 250mV pk-pk DUAL OUTPUT PMMK150D-AD PMMK150D-BD PMMK150D-CD PMMK150D-DD 5/12 VDC 5/24 VDC 12/24 VDC 12/48 VDC 15/7 15/3.5 7/3.5 7/1.5 ±0.5/1% ±0.5/2% ±1/2% ±1/4% 50/100mV pk-pk 50/200mV pk-pk 100/200mV pk-pk 100/400mV pk-pk WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 M e d i c a l G r a d e 1 50 Watt with DIN Rail mount and PFC INPUT SPECIFICATIONS Input Voltage Range Frequency Range Power Factor Correction Inrush Current, typ: Leakage Current series ENVIRONMENTAL SPECIFICATIONS 90-264 VAC 47-63 Hz 0.96 min. 30A @ 115VAC 60A @ 230VAC * <300UA @ 264VAC, 50Hz OUTPUT SPECIFICATIONS Voltage and Current (Note 6) See Selection Chart Line Regulation (Note 8) See Selection Chart Load Regulation (10%-FL, Note 7) Singles: ± 1%, max. Duals: ±3/5% Preset Accuracy (Note 9) ±1%, typ Ripple/Noise (Notes 1, 3, 10) See Selection Chart Over Voltage Protection Auto Recover after fault condition is removed * Short Circuit Protection Auto Recover after fault condition is removed * Hold Up Time 20mS, typ (Nom I/P, FL) GENERAL SPECIFICATIONS Isolation (Note 4) Efficiency Safety UL/cUL: UL-EU: CB: CE: PMMK150-D I/P-O/P: 5656VDC I/P-Ground: 2828VDC O/P-Ground: 707VDC 75%, min. ANSI/AAMI ES60601-1 3rd ed. CSA C22.2 No. 60601-1 3rd ed. EN60601-1 3rd ed. IEC60601-1 3rd ed. EN60601-1-2 All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Oper. Temperature Storage Temperature Relative Humidity EMC MTBF -10 to +70°C (See Derate Curve) -25 to +85°C * 0% to +95%, non-cond * EN55011 Class B 270,000 Hrs Mil Std 217, 25°C PHYSICAL SPECIFICATIONS Size Construction Weight 3.2” x 5.5” x 1.6” Enclosed DIN Rail 1.4 lb, (635g) NOTES 1. All measurements should be made directly at the terminals of the power supply 2. All specifications typical @ 25°C, unless otherwise noted, at nominal line and load. 3. Ripple and noise dependent upon output voltage as specified per particular model. 4. Isolation for up to 1 minute duration. 5. Specified for free air convection cooling. 6. Minimum load is not required for proper operation. 7. Load Regulation is measured by change ±40% of measured output load from 60% full load, with the other output set to 60% full load. 8. Line Regulation measured from 90-264VAC. 100VAC minimum required for full load start. 9. Preset Accuracy measured at nominal load, 120VAC input. 10. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 M e d i c a l G r a d e 1 50 Watt with DIN Rail mount and PFC PMMK150-D series MECHANICAL DIMENSIONS 65 .70 m m [2.58 7 in] 134 .00 m m [5.276 in] 13 9.70 mm [5.500 in] 28.20 mm [1.110 in] 5.70 mm [0.224 i n] 15.10 mm [0.594 in] 12.00 mm [0.472 in] 24.00 mm [0.945 in] M3 hole size 80.40 mm [3.165 in] 65.30 mm [2.571 in] 7_ M3x0.5 - 6H ( The L ength : 3 mm ) 40.60 mm [1.598 in] WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 M e d i c a l G r a d e 1 50 Watt with DIN Rail mount and PFC PMMK150-D series 98.90 m m [3.894 in] WWW.ASTRODYNE.COM 6.50 mm [0.256 in] 1.50 m m [0.059 in] 6.50 mm [0.256 in] 8.80 mm [0.346 in] 139.70 mm [5.500 i n] 80.40 mm [3.165 in] 40.60 m m [1.598 in] 50.90 mm [2.004 in] 20.20 m m [0.795 in] 60.20 mm [2.370 in] M3 hole size ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 M e d i c a l G r a d e 1 50 Watt with DIN Rail mount and PFC PMMK150-D series OUTPUT DERATING CURVE - SINGLE OUTPUT OUTPUT DERATING CURVE - DUAL OUTPUT 1. Forced air colling 10 CFM 2. Free air convection - Open Frame, U-Channel 3. Free air convection - Enclosed WWW.ASTRODYNE.COM 4112 ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458