1 5 0 Wa t t O p e n F rame Switching Power Supply with PFC Pmk150 series 150 Watts Output Power Single and Dual Outputs Universal 90-264VAC Input 5VDC to 48VDC Outputs 3000VAC Input to Output Isolation Active Power Factor Correction 3”W x 5.5”L x 1.4”H Model Number Output Voltage Output Amps (max) Line Regulation Ripple & Noise SINGLE OUTPUT PMK150S-5 PMK150S-12 PMK150S-15 PMK150S-24 PMK150S-48 5 VDC 12 VDC 15 VDC 24 VDC 48 VDC 30 12.5 10 6.3 3.2 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% 100mV pk-pk 100mV pk-pk 100mV pk-pk 100mV pk-pk 100mV pk-pk DUAL OUTPUT PMK150D-A PMK150D-B PMK150D-C PMK150D-D 5/12 VDC 5/24 VDC 12/24 VDC 12/48 VDC 15/7 15/3.5 7/3.5 7/1.5 ±0.5/1% ±0.5/2% ±1/2% ±1/4% 50/100mV pk-pk 50/200mV pk-pk 100/200mV pk-pk 100/400mV pk-pk WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060 1 5 0 Wa t t O p e n F rame Switching Power Supply with PFC INPUT SPECIFICATIONS Input Voltage Range Frequency Range Power Factor Correction Inrush Current, typ: series ENVIRONMENTAL SPECIFICATIONS 90-264 VAC 47-63 Hz 0.96 to 0.98 30A @ 115VAC 60A @ 230VAC * OUTPUT SPECIFICATIONS Voltage and Current (Note 6) See Selection Chart Line Regulation (Note 8) See Selection Chart Load Regulation (10%-FL, Note 7) Singles: ± 0.5%, typ Duals: ±3/5%, typ Preset Accuracy (Note 9) ±1%, typ DC Voltage Adjust (typ) ±6%, typ Temperature Coefficient ±0.05%/°C Ripple/Noise (Notes 1, 3, 10) See Selection Chart Over Voltage Protection Latching, Auto Recover after fault condition is removed * Short Circuit Protection Latching, Auto Recover after fault condition is removed * Hold Up Time 20mS, typ (Nom I/P, FL) GENERAL SPECIFICATIONS Isolation (Note 4) Efficiency Switching Frequency Safety Pmk150 I/P-O/P: 3000VAC I/P-Ground: 2000VAC O/P-Ground: 500 VAC 75%, min. 67Khz, (fixed, typical) UL,TUV, CB, CE All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Oper. Temperature Storage Temperature Relative Humidity EMC MTBF -10 to +70°C (See Derate Curve) -25 to +85°C * 0% to +95%, non-cond * EN55011 Class B 270,000 Hrs Mil Std 217, 25°C PHYSICAL SPECIFICATIONS Size Construction Weight 3” x 5.5” x 1.4” Open Frame 0.5 lb, (226g) Notes 1. All measurements should be made directly at the terminals of the power supply 2. All specifications typical @ 25°C, unless otherwise noted, at nominal line and load. 3. Ripple and noise dependent upon output voltage as specified per particular model. 4. Isolation for up to 1 minute duration. 5. Specified for free air convection cooling. 6. Minimum load is not required for proper operation. 7. Load Regulation is measured by change ±40% of measured output load from 60% full load, with the other output set to 60% full load. 8. Line Regulation measured from 90-264VAC. 100VAC minimum required for full load start. 9. Preset Accuracy measured at nominal load, 120VAC input. 10. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060 Pmk150 1 5 0 Wa t t O p e n F rame Switching Power Supply with PFC MECHANICAL DIMENSIONS 2.00 ± 0.50 mm [0.079 ± 0.020 in] 3.4 m [0. 13 4i n] 9 8 7 6 5 4 1 2 3 76.20 mm [3.000 in] 0m 71.20 mm [2.803 in] Ø 35.00 mm [1.378 in] 5.00 mm [0.197 in] 4_ series 5.70 mm [0.224 in] 134.00 mm [5.276 in] 139.70 mm [5.500 in] Pin # Outputs 1 2 3 4 5 6 7 8 9 GND ACN ACL + Output + Output Common Common Common N/C WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060 1 5 0 Wa t t O p e n F rame Switching Power Supply with PFC Pmk150 series OUTPUT DERATING CURVE - Single Output OUTPUT DERATING CURVE - Dual Output 1. Forced air colling 10 CFM 2. Free air convection - Open Frame, U-Channel 3. Free air convection - Enclosed WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060