FB100-10 Filter Module 100V, 10A Product Data Sheet

FB100-10 Filter Module
Rev 20090310a
100V, 10A
Product Data Sheet
ADDITIONAL FEATURES:
DESCRIPTION:
The FB100-10 Filter Module is designed to reduce
the conducted differential-mode and commonmode noise on input lines of DC/DC power
modules. It provides high insertion loss throughout the frequency range regulated by FCC and
CISPR for conducted emissions.
FEATURES:
•
Minature Size: 2.00in x 1.125in x 0.50in (
50.8mm x 28.6mm x 12.7mm )
•
Optimized for use with RO SuperVerter
fixed frequency DC to DC power modules
•
Printed circuit board mountable
•
Allows power modules to meed FCC and
EN55022 (CISPR22)
www.astrodyne.com
www.roassoc.com
30
•
Designed to meet UL1959; CSA C22.2 No.
950-95; VDE 0805
•
Isolation voltage: 1500Vdc
•
Maximum input voltage: 100V
•
Operating case temperature range: -40 to
70°C
•
Storage temperature: -40 to 100°C
•
Calculated MTBF TBD hours at case
temperature 65 degree C (Bellcore
Standard).
•
Short Leads: 0.23in ( 5.8mm )
TYPICAL CHARACTERISTECS:
•
Resistance per leg: Typ. 0.015 Ohm
•
Common-mode insertion loss: 40dB at
500kHz
•
Differential-mode insertion loss: 52dB at
500kHz
Astrodyne USA: 1-800-823-8082
FB100-10 Filter Module Datasheet
INSERTION LOSS
(with 50Ω source and load impedances)
INSERTION LOSS (dB)
70
60
50
DM
40
30
20
CM
10
0
.01
.02
.04
.1
1
.4
4
.2
2
.07
.7
7
FREQUENCY (MEGAHERTZ)
10
20
40
70
100
OUTLINE DRAWING
Tolerances:
x.xx: ± 0.005
x.xxx: ± 0.015
www.astrodyne.com
www.roassoc.com
30
2
Astrodyne USA: 1-800-823-8082
FB100-10 Filter Module Datasheet
SCHEMATIC
4700pF
4.7µF
4700pF
100µH
0.7mH
APPLICATION RECOMMENDATIONS
NOTE 1: C1 through C4 can be 0.01uF to 0.1uF.
NOTE 2: C6 ceramic capacitor can be 0uF to 4.7uF.
NOTE 3: C7 aluminum electrolytic capacitor.
NOTE 4: C8 aluminum electrolytic capacitor.
www.astrodyne.com
www.roassoc.com
30
3
Astrodyne USA: 1-800-823-8082
FB100-10 Filter Module Datasheet
RECOMMENDED PCB LAYOUT
SETUP FOR MEASURING CONDUCTED EMI
www.astrodyne.com
www.roassoc.com
30
4
Astrodyne USA: 1-800-823-8082
FB100-10 Filter Module Datasheet
TEST RESULTS
Data not available yet.
(a) Differential Mode
Data not available yet.
(b) Common Mode
Fig. 1. SV28-28-200 (Vi=28V, V0=28V, Io=8.6A) with filter and external circuit to
meet FCC/VDE class B. C1 through C4 is 0.068µF, C6 is 3.3µF, C7 and C8
are 220µF.
www.astrodyne.com
www.roassoc.com
30
5