FB100-10 Filter Module Rev 20090310a 100V, 10A Product Data Sheet ADDITIONAL FEATURES: DESCRIPTION: The FB100-10 Filter Module is designed to reduce the conducted differential-mode and commonmode noise on input lines of DC/DC power modules. It provides high insertion loss throughout the frequency range regulated by FCC and CISPR for conducted emissions. FEATURES: • Minature Size: 2.00in x 1.125in x 0.50in ( 50.8mm x 28.6mm x 12.7mm ) • Optimized for use with RO SuperVerter fixed frequency DC to DC power modules • Printed circuit board mountable • Allows power modules to meed FCC and EN55022 (CISPR22) www.astrodyne.com www.roassoc.com 30 • Designed to meet UL1959; CSA C22.2 No. 950-95; VDE 0805 • Isolation voltage: 1500Vdc • Maximum input voltage: 100V • Operating case temperature range: -40 to 70°C • Storage temperature: -40 to 100°C • Calculated MTBF TBD hours at case temperature 65 degree C (Bellcore Standard). • Short Leads: 0.23in ( 5.8mm ) TYPICAL CHARACTERISTECS: • Resistance per leg: Typ. 0.015 Ohm • Common-mode insertion loss: 40dB at 500kHz • Differential-mode insertion loss: 52dB at 500kHz Astrodyne USA: 1-800-823-8082 FB100-10 Filter Module Datasheet INSERTION LOSS (with 50Ω source and load impedances) INSERTION LOSS (dB) 70 60 50 DM 40 30 20 CM 10 0 .01 .02 .04 .1 1 .4 4 .2 2 .07 .7 7 FREQUENCY (MEGAHERTZ) 10 20 40 70 100 OUTLINE DRAWING Tolerances: x.xx: ± 0.005 x.xxx: ± 0.015 www.astrodyne.com www.roassoc.com 30 2 Astrodyne USA: 1-800-823-8082 FB100-10 Filter Module Datasheet SCHEMATIC 4700pF 4.7µF 4700pF 100µH 0.7mH APPLICATION RECOMMENDATIONS NOTE 1: C1 through C4 can be 0.01uF to 0.1uF. NOTE 2: C6 ceramic capacitor can be 0uF to 4.7uF. NOTE 3: C7 aluminum electrolytic capacitor. NOTE 4: C8 aluminum electrolytic capacitor. www.astrodyne.com www.roassoc.com 30 3 Astrodyne USA: 1-800-823-8082 FB100-10 Filter Module Datasheet RECOMMENDED PCB LAYOUT SETUP FOR MEASURING CONDUCTED EMI www.astrodyne.com www.roassoc.com 30 4 Astrodyne USA: 1-800-823-8082 FB100-10 Filter Module Datasheet TEST RESULTS Data not available yet. (a) Differential Mode Data not available yet. (b) Common Mode Fig. 1. SV28-28-200 (Vi=28V, V0=28V, Io=8.6A) with filter and external circuit to meet FCC/VDE class B. C1 through C4 is 0.068µF, C6 is 3.3µF, C7 and C8 are 220µF. www.astrodyne.com www.roassoc.com 30 5 Astrodyne USA: 1-800-823-8082