Serial Bluetooth Converter for V.24 (RS-232), RS

Serial Bluetooth Converter for V.24 (RS-232), RS-422, and
RS-485 2-Wire Bus Systems
PSI-WL-RS232-RS485/BT
1. Description
The Bluetooth converter provides a quick and easy
wireless connection between serial interfaces of the
V.24 (RS-232), RS-422, and RS-485 2-wire standard.
The wireless connection can extend up to 150 m
and is based on the international license-free Bluetooth
standard.
This wireless standard meets high requirements for
interference-free data transmission, in particular
through the use of the FHSS method (Frequency
Hopping Spread Spectrum) with the 2.4 GHz ISM
band.
The Bluetooth converter can be used for a wide
range of different applications, for example:
– Replacement of simple, serial point-to-point cabling
for V.24 (RS-232), RS-422, and RS-485 2-wire
interfaces.
– Creation of master/slave multi-drop connections.
– Wireless operation and monitoring for processes.
– Wireless parameterization, and diagnostic and
programming connections.
– Replacement of slip ring joints or drag chains.
– Implementation of high-quality electrical isolation
between the stations.
The PSI-WL-RS232-RS485/BT serial Bluetooth
converter is designed for industrial use and features
the following performance characteristics:
– Mounting by snapping on to an EN DIN rail
– Supply of 24 V DC or AC
– Transmission speed of up to 187.5 kbps
– Can be set to V.24 (RS-232), RS-422 or RS-485
– Supports all popular 10/11-bit UART data formats
– 3964R-compatible
– External antenna connection for optimum antenna
positioning
– Bluetooth access protected by password, fixed
device pairing or device access list
– Scalable transmission power (-28 to 20 dBm) for
specific localization of the radio cell
– Integrated Bluetooth path diagnostics indicate the
signal quality of the radio connection.
Should you have any technical questions, please
contact us:
PSM HOTLINE: +49 - 52 35 - 31 98 90
FAX: +49 - 52 35 - 31 98 99
E-mail: [email protected]
The PSI-WL-RS232-RS485/BT Bluetooth converter
is accessed via a second, identical device or via the
PSI-WL-PLUG-RS232/BT V.24 (RS-232) adapter,
which is in the form of a connector. Wireless access via
third-party devices, which already have an integrated
Bluetooth interface, e.g., PDA, notebook or cell phone,
is also supported (see page 2).
Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany
Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com
Local contact: www.phoenixcontact.com/salesnetwork
Serial Bluetooth Converter for V.24 (RS-232), RS-422, and RS-485 2-Wire Bus – PSI-WL-RS232-RS485/BT
2. Application
2.1 Point-to-Point Connections
Programming device and PLC
Point-to-Point
Without Termination Device Addressing
(V.24 (RS-232), RS-422, etc.)
– Direct programming connection between a laptop
and a programmable logic controller (Figure 02).
Figure 02
– Data connection between a third-party device with
integrated Bluetooth interface (PDA, cell phone,
etc.) and an industrial controller (Figure 03).
PDA and PLC
Figure 03
– Connection between a mobile operator interface
and an industrial controller (Figure 04).
PLC and operating panel
Figure 04
Point-to-Point
With Termination Device Addressing
(RS-485 2-Wire)
– Integration of a device into an existing bus system,
e.g., Modbus, PROFIBUS, etc. (Figure 05).
RS-485 2-wire bus system
Figure 05
2.2 Multi-Drop Connections
Networking for automation components.
Up to seven Bluetooth slaves can be connected
to a Bluetooth master (Figure 06).
1x master and up to 7x slaves
Figure 06
PHOENIX CONTACT page 2 of 8
Serial Bluetooth Converter for V.24 (RS-232), RS-422, and RS-485 2-Wire Bus – PSI-WL-RS232-RS485/BT
3. Technical Data
2 2 ,5
1 1 4 ,5
(4 .5 0 8 " )
(0 .8 8 6 " )
P S I-W L -R S 2 3 2 R S 4 8 5 /B T
O rd .-N o . 2 7 0 8 5 1 7
9 9
(3 .8 9 8 " )
V C C
T D
A N T
R D
R E S
B T
S IG N A L
S E R
E R R
R S 2 3 2
6 1 4 5 1 0 0 1
PSI-WL-RS232-RS485/BT
UL (in preparation)
2 4 V
B a c k p la n e
V C C
2 4 V
V C C
5 V
g n
+ 5 V
0 V
2 4 V
0 V
D -S U B -9
R S -2 3 2
D C E
T x D
3
R x D
2
R T S
7
C T S
8
D T R
4
D S R
6
G N D
5
+ 5 V
R D
g n
T D
y e
P u s h
R E S
T e r m in a tio n
3 9 0 W
1 5 0 W
3 9 0 W
S W
(A )
D
(B )
H W
C O N F
R S 2 3 2
R S 4 2 2
R S 4 8 5
R U N
T (A )
M C X
A N T
- S w itc h
B lu e to o th
µ C
T (B )
G N D
B T S ig n a l
C O M B IC O N
R S -4 2 2 / R S 4 8 5 W 2
D
- S w itc h
b u tto n
( S h ie ld )
g n
g n
y e
r e d
S E R
Description
Bluetooth converter for converting V.24 (RS-232)/RS-422/
RS-485 2-wire to Bluetooth, range up to 150 m,
DIN rail mounting, 24 V supply.
Scope of supply:
DIN-rail mountable Bluetooth device, CD with configuration software
and user manual
E R R
Pcs.
Pkt.
Type
Order No.
PSI-WL-RS232-RS485/BT
27 08 51 7
1
RAD-ISM-2400-ANT-OMNI-2-1
28 67 46 1
1
RAD-ISM-2400-ANT-PAN-8-0
28 67 61 0
1
RAD-PIG-EF316-MCX-SMA
28 67 67 8
1
Accessories
Lambda/4 antenna with
omni-directional characteristics,
mounting bracket, antenna cable
with angled antenna connector.
Gain
Polarization
Impedance
Degree of protection
Dimensions
Panel antenna with
directional characteristics,
mounting clamp
and antenna connection.
Gain
Polarization
Impedance
Degree of protection
Dimensions (H x W x D)
Coaxial antenna cable
for panel antenna.
Connections
Attenuation
Impedance
1.50 m
MCX
2 dBi
Omni, vertical
50 Ω
IP65
∅ 8.2 mm x 82.5 mm
∅ 40 mm to 60 mm
SMA
8 dBi
Linear, vertical
50 Ω
IP55
101 mm x 80 mm x 20 mm
1 m (3.28 ft.)
MCX/SMA
2 dB
50 Ω
PHOENIX CONTACT page 3 of 8
Serial Bluetooth Converter for V.24 (RS-232), RS-422, and RS-485 2-Wire Bus – PSI-WL-RS232-RS485/BT
Additional Accessories
System power supply
primary switched.
Input voltage range
Nominal output voltage
Nominal output current
45 to 65 Hz
85 to 264 V AC
24 V DC ±1%
1.5 A
DIN rail bus connector
Pcs.
Pkt.
Type
Order No.
MINI-SYSPS-100-240AC/24DC/1.5
28 66 983
1
ME 22,5 TBUS 1,5/ 5-ST-3,81 GN
27 07 437
1
Technical Data
Supply
Supply voltage 1
(function elements 12 - 13)
10 to 30 V DC,
24 V AC ±20%
Via plug-in COMBICON screw terminal block
Protection against polarity reversal via bridge rectifier
Supply voltage 2
(alternative or redundant)
24 V DC ±20%
Via backplane bus contact and appropriate system power supply,
protection against polarity reversal via series diode.
Frequency
DC or 50 to 60 Hz
Nominal current consumption
40 mA at 24 V DC
70 mA RMS at 24 V AC
LED indicator
(function element 9)
Configuration
System requirements
Windows 98 SE, 2000, NT4, XP
Configuration interface
V.24 (RS-232), Bluetooth,
The system is configured in CONF mode via the V.24 (RS-232)
interface and the configuration software provided.
Either the local device is configured or a remote device is configured
via Bluetooth.
V.24 (RS-232) Interface
Physics
Connection
VCC (green LED):
- Steady light during operation in RUN mode
- Flashing during operation in CONF mode
EIA/TIA RS-232
(function element 1)
9-pos. D-SUB pin strip
Device type
DCE (Data Communication Equipment) with 1:1 cable
to DTE (Data Terminal Equipment).
Signal assignment
TxD = 3, RxD = 2, RTS = 7, CTS = 8, DTR = 4, DSR = 6, GND = 5
Data format
Serial asynchronous UART/NRZ
Encoding
7/8 data, 1/2 stop, 1 parity, 10/11-bit character length
can be adjusted via software.
Protocols
Transparent protocol, including 3964R protocol
Serial transmission speed
0.3, 1.2, 2.4, 4.8, 7.2, 9.6, 19.2, 31.25, 38.4, 57.6, 75, 93.75, 115.2,
136, 187.5 kbps can be adjusted via software.
Data flow control
Hardware handshake:
- Termination device directly with the Bluetooth converter via
RTS/CTS
- Data transmission speed of up to 187.5 kbps
Software handshake (Xon/Xoff):
- Software handshake is negotiated directly between the termination
devices
- Setting on Bluetooth converter = "none"
- Data transmission speed of up to 38.4 kbps
Message-oriented protocols, e.g., Modbus, PROFIBUS, etc.:
- Setting on Bluetooth converter = "none"
- Data transmission speed of up to 93.75 kbps
Default upon delivery
9.6 kbps, 8 data, no parity,
1 stop bit, hardware handshake
LED indicator/serial data indicator
LED indicator/serial system diagnostics
(function elements 7 - 8)
(function element 2)
TD (yellow LED), dynamic, serial port is transmitting data,
RD (green LED), dynamic, serial port is receiving data
SER ERR (red LED),
parity error, handshake error, buffer data overrun
PHOENIX CONTACT page 4 of 8
Serial Bluetooth Converter for V.24 (RS-232), RS-422, and RS-485 2-Wire Bus – PSI-WL-RS232-RS485/BT
RS-422/RS-485 2-Wire
Physics
Connection
EIA/TIA RS-422 and RS-485 2-wire,
can be switched via configuration software,
default upon delivery is V.24 (RS-232)
(function elements 10 - 11, 14 - 17)
Termination resistor/termination
(function element 19)
Plug-in COMBICON screw terminal block
390 - 150 - 390 Ω can be enabled in the device, default upon
delivery is OFF
Signal assignment for RS-422
Transmit pos. = TB, Transmit neg. = TA,
Receive pos. = DB, Receive neg. = DA
Signal ground = GND, Shield connection = FE
Signal assignment for RS-485 2-wire
Bluetooth Interface
Physics
Frequency
Channel distance
Bandwidth
Channels
Transmission method
Transmit/Receive pos. = DB, Transmit/Receive neg. = DA
Radio approvals
Bluetooth 1.1 Specification
2.402 GHz to 2.480 GHz (ISM band 2.4 GHz)
1 MHz
79 MHz
79
Frequency hopping 1.6 kHz (FHSS)
USA (in preparation):
Canada (in preparation):
Europe:
Approved countries:
FCC/CFR 47, Part 15
RSS-210
ETSI EN 300 328, 300 826
EU countries:
Belgium, Denmark, Germany, Estonia, Finland, France, Greece,
Great Britain, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Austria, Poland, Portugal, Sweden, Slovakia, Slovenia,
Spain, Czech Republic, Hungary, Cyprus
Non-EU countries:
Iceland, Norway, Switzerland, USA, Canada
Other countries on request
Notification
EU countries, Iceland, Switzerland, Norway
R&TTE device class
Class 2
Usage restrictions according to
ERC Recommendation 70-03/April 2004
France: Outside buildings the
maximum transmission power is 10 mW (10 dBm),
(note antenna data and software settings)
Italy: Outside buildings a license is required for operation and
the maximum transmission power is 10 mW (10 dBm),
(note antenna data and software settings)
Bluetooth device class
Class 1 = 100 mW (20 dBm), maximum
Transmission power
20 dBm = default upon delivery,
can be set via software from -28 dBm to +20 dBm
Range guide values
(depending on the application environment)
20 dBm = 80 m to 150 m
10 dBm = 40 m to 70 m
0 dBm = 10 m to 30 m
Receiver sensitivity
-80 dBm at 0 dBi antenna gain
Antenna
External antenna, not included in the scope of supply,
(see list of accessories)
Antenna connection
(function element 18)
MCX
Bluetooth profile
- GAP (Generic Access Profile)
(method for authentication and connection establishment)
- SDAP (Service Discovery Application)
(method for requesting supported services)
- SPP (Serial Port Profile)
(COM port emulation method)
- DUN (Dial-up Networking Profile)
(modem dial-up method)
- LAP (LAN Access Point Profile)
(network connection method)
Number of Bluetooth masters/Bluetooth slaves
1x master/7x slaves
LED indicator/Bluetooth data indicator
LED indicator/Bluetooth transmission quality
(function element 3)
(function elements 3 - 5)
(function elements 3 - 4)
(function element 3)
BT SIGNAL (1x yellow LED flashing),
Bluetooth is transmitting/receiving data
BT SIGNAL (1x yellow LED, 2x green LEDs), very good reception
BT SIGNAL (1x yellow LED, 1x green LED), good reception
BT SIGNAL (1x yellow LED), poor reception, close to the
system reserve
PHOENIX CONTACT page 5 of 8
Serial Bluetooth Converter for V.24 (RS-232), RS-422, and RS-485 2-Wire Bus – PSI-WL-RS232-RS485/BT
General Data
CE conformance
According to R&TTE Directive 1999/5/EC
Approvals
UL (in preparation)
Ambient operating temperature range during operation
-20°C to +60°C.
Housing
- Material
- Dimensions (H x W x D in mm)
ME 22,5 LWL LINE with 5-pos. ME-T bus contact and ground contact
ABS-VO, green
99 x 22.5 x 114.5 mm
Weight of device
120 g, approximately
Functional earth ground
Housing contact with DIN rail
Vibration resistance
According to DIN EN 60068-2-6
5g, 2.5 h in each x, y, and z direction
Criterion A (no functional disruption)
Shock test
According to DIN EN 60068-2-27
15 g, 11 ms pulse length
Criterion C (module is not damaged)
Free fall
According to DIN EN 60950 from a height of 1 m. without packaging
Degree of protection
IP20
Air and creepage distances
According to VDE 0110-1, DIN EN 50178, DIN EN 60950
Ambient compatibility
Free from substances, which would hinder coating with paint or varnish
according to central standard P-VW 3.10.7 -3.10 0.757 650 of VW,
Audi, and Seat (chloroform test)
Separate ground levels
24 V supply // 5 V logic + serial ports // functional earth ground
Test voltage
1.5 kV AC, 50 Hz, 1 min. between all ground levels
according to EN 50 178 and EN 61 131-2
PHOENIX CONTACT page 6 of 8
Serial Bluetooth Converter for V.24 (RS-232), RS-422, and RS-485 2-Wire Bus – PSI-WL-RS232-RS485/BT
c
According to R&TTE Directive 1999/5/EC:
EMC*)
Noise immunity (Electromagnetic Compatibility)
EN 61000-6-2:2001
Safety
Protection of personnel with regard to electrical safety.
EN 60950 : 2001
Health
Limitation of exposure of the population to electromagnetic fields.
Radio
Effective use of the frequency spectrum and prevention of
radio interference.
*)
EC Gazette
1999/519/EC
Generic standard for the
industrial sector
EC Council recommendation
of July 12, 1999
ETSI EN 300 328:
V1.2.1, V1.4.1
Addition: EMC (Electromagnetic Compatibility)
Noise Immunity According to EN 61000-6-2
8 kV air discharge 2)
6 kV contact discharge 2)
• Electrostatic discharge (ESD)
EN 61000-4-2
• Electromagnetic HF field
Amplitude modulation
Pulse modulation
EN 61000-4-3
• Fast transients (burst)
Signal:
Supply:
EN 61000-4-4
• Surge current loads (surge)
Signal:
Supply:
EN 61000-4-5
• Immunity to conducted interference
EN 61000-4-6
10 V/m 1)
• Noise emission:
Conducted emission
Radiated emission
EN 55011
ETSI EN 300 328
Class A
EN 61000 corresponds to IEC 1000
EN 55011 corresponds to CISPR11
1)
2)
Criterion A: Normal operating characteristics within the specified
limits.
Criterion B: Temporary adverse effects on the operating
characteristics that the device corrects automatically.
Class A:
Industrial application, without special
installation measures.
PHOENIX CONTACT page 7 of 8
10 V/m 1)
10 V/m 1)
2 kV/2 min. 2)
2 kV/2 min. 2)
1 kV/42 Ω 2)
0.5 kV/2 Ω symmetrical 2)
0.5 kV/12 Ω asymmetrical 2)
Serial Bluetooth Converter for V.24 (RS-232), RS-422, and RS-485 2-Wire Bus – PSI-WL-RS232-RS485/BT
4. Function Elements/Diagnostics
1 2
1 3
1 4
1 5
1 1
1 6
1 0
1 7
P S I-W L -R S 2 3 2 R S 4 8 5 /B T
O rd .-N o . 2 7 0 8 5 1 7
9
8
7
V C C
T D
A N T
R D
6
1 8
R E S
5
B T
S IG N A L
4
3
2
S E R
A
19
R S 2 3 2
1
E R R
20 B
6 1 4 5 1 0 0 1
PHOENIX CONTACT page 8 of 8
TNR:102403-00-GB
11/15/04
11. GND, operating ground
12. VCC, supply of 10 to 30 V DC, 24 V AC ±20%
13. 0 V, supply of 0 V
14. TA, RS-422: Transmit negative
15. TB, RS-422: Transmit positive
16. DA, RS-422: Receive negative
RS-485 2-wire: Transmit/Receive negative
17. DB, RS-422: Receive positive
RS-485 2-wire: Transmit/Receive positive
18. MCX connection, for external antenna
19. Switch for RS-422/RS-485 Terminate ON/OFF
20. Switch for CONF/RUN
 PHOENIX CONTACT
1. 9-pos. D-SUB, V.24 (RS-232) data interface
2. Red LED, incorrect interface setting or
buffer overrun
3. Yellow LED, poor reception, close to the
system reserve
4. Green LED, good reception
5. Green LED, very good reception
6. Pushbutton, to reset settings
7. Green LED, dynamic, serial port is receiving
data
8. Yellow LED, dynamic, serial port is transmitting
data
9. Green LED, steady light during operation in
RUN mode, flashing during operation in
CONF mode
10. 6, shield connection
http://www.phoenixcontact.com
Figure 09