Data Sheet FL SWITCH SFN…24VAC

FL SWITCH SFN…24VAC
Five- and Eight-Port Standard Function Ethernet
Switch with Narrow Housings for 24 V AC Power
AUTOMATION
Data Sheet
2686_en_D
1
© PHOENIX CONTACT 2009-12
Description
2
The FL SWITCH SFN…-24VAC range of Factory Line
switches can be used for quick and cost-effective Ethernet
network expansion to the field level. Due to the narrow
housing design, the switches are suitable for use in control
cabinets and junction boxes.
–
The FL SWITCH SFN…-24VAC switches support the auto
negotiation function on the RJ45 ports and offer
transmission speeds of 10/100 Mbps. Mixed operation for
the connection of segments with different data transmission
speeds is also supported. The RJ45 ports offer an auto
crossing function, which means it is not necessary to make
a distinction between 1:1 and crossover cables. Unused
RJ45 ports can be fitted with security caps to provide
mechanical protection against unauthorized use.
–
–
–
–
–
–
–
–
–
–
–
–
Features and Benefits
Switched Ethernet networks reduce traffic and nonpredictable timing
Pretagged high priority messages are forwarded before
lower priority messages during periods of high network
traffic
Auto-negotiation and autocross simplify cabling
Couple copper network segments with different bit rates
with automatic detection of the data transmission speed
of 10 or 100 Mbps
Individual LEDs at each port indicate communication
activity and data rate
-0 to 60°C operating range
Removable power connector
NS 35 DIN rail (EN 60715) compatible
Industrial rated, rugged metal housing for industrial
applications
Low-cost, low-complexity security by connecting
Layer 1 security elements at the RJ45 ports to restrict
access and tampering (optional)
Meets IEC 61000-6-2 electrical noise immunity
Meets IEC 60068-2-6 vibration test standards
Meets IEC 60068-2-27 shock test standards
Make sure you always use the latest documentation.
It can be downloaded at www.phoenixcontact.net/catalog.
This data sheet is valid for all products listed on the following page:
FL SWITCH SFN…24VAC
3
Ordering Data
Description
Type
Order No.
Pcs./Pkt.
Ethernet switch, with 5 RJ45 ports for 10/100 Mbps
FL SWITCH SFN 5TX-24VAC
2891021
1
Ethernet switch, with 8 RJ45 ports for 10/100 Mbps
FL SWITCH SFN 8TX-24VAC
2891020
1
Accessories
Description
Type
Order No.
Pcs./Pkt.
Universal end clamp
E/NS 35 N
0800886
50
Patch angle with 2 ports in CAT 5e
FL PF 2TX CAT5E
2891165
1
Patch angle with 8 ports in CAT 5e
FL PF 8TX CAT5E
2891178
1
Patch angle with 2 ports in CAT 6
FL PF 2TX CAT6
2891068
1
Patch angle with 8 ports in CAT 6
FL PF 8TX CAT6
2891071
1
Patch angle with security elements for 2 ports in CAT 5e
FL PF SEC 2TX
2832687
1
Patch angle with security elements for 8 ports in CAT 5e
FL PF SEC 8TX
2832690
1
Patchbox 8 x RJ45 CAT 5e, pre-assembled, can be retrofitted
FL PBX 8TX
2832496
1
Patch cable, CAT 5, pre-assembled, 0.3 m long
FL CAT5 PATCH 0,3
2832250
10
Patch cable, CAT 5, pre-assembled, 0.5 m long
FL CAT5 PATCH 0,5
2832263
10
Patch cable, CAT 5, pre-assembled, 1.0 m long
FL CAT5 PATCH 1,0
2832276
10
Patch cable, CAT 5, pre-assembled, 1.5 m long
FL CAT5 PATCH 1,5
2832221
10
Patch cable, CAT 5, pre-assembled, 2.0 m long
FL CAT5 PATCH 2,0
2832289
10
Patch cable, CAT 5, pre-assembled, 3.0 m long
FL CAT5 PATCH 3,0
2832292
10
Patch cable, CAT 5, pre-assembled, 5.0 m long
FL CAT5 PATCH 5,0
2832580
10
Patch cable, CAT 5, pre-assembled, 7.5 m long
FL CAT5 PATCH 7,5
2832616
10
Patch cable, CAT 5, pre-assembled, 10.0 m long
FL CAT5 PATCH 10
2832629
10
Security frame for SFN switch and patch fields, green
FL PLUG GUARD, GN
2891615
20
Security frame for SFN switch and patch fields, red
FL PLUG GUARD, RD
2891712
20
Security frame for SFN switch and patch fields, white
FL PLUG GUARD, WH
2891819
20
Security frame for SFN switch and patch fields
FL PORT GUARD
2891220
20
Security frame for SFN switch and patch fields
FL PLUG GUARD KEY
2891327
1
Security element for FL CAT patch
FL PATCH SAFE CLIP
2891246
20
4
Technical Data
General Data
Function
Switch/repeater; conforms to standard IEEE 802.3
Latency of the communication processor
8 µs plus frame time
Housing dimensions (width x height x depth)
5-port switch, without connectors
8-port switch, without connectors
30 x 120 x 70 mm
50 x 120 x 70 mm
Weight
5-port switch, without connectors
8-port switch, without connectors
277 g
340 g
Operating temperature
0°C to 60°C
Storage temperature
-20°C to 85°C
Degree of protection
IP20, DIN 40050, IEC 60529
Protection class
Class 3 VDE 0106; IEC 60536
Humidity (operation and storage)
5% to 95%, no condensation
Air pressure (operation)
86 kPa to 108 kPa, 1500 m above sea level
Air pressure (storage)
86 kPa to 108 kPa, 3500 m above sea level
Mounting rail
NS 35 (EN 60715)
Preferred mounting position
Perpendicular to a standard rail
Connection to protective earth ground
Snapped onto a grounded rail
2686_en_D
PHOENIX CONTACT
2
FL SWITCH SFN…24VAC
Supply Voltage (US)
Connection type
Removable, spring-cage connector
Wire size (solid/stranded/AWG)
0.2 to 2.5 mm² / 0.2 to 2.5 mm² / 24 to 12 AWG
Recommended PE wire size
2.5 mm2
Nominal power supply
24 V AC/24 V DC
Permissible ripple
3.6 Vpp within the permissible voltage range
Permissible voltage range
20 V AC to 28 V AC
12 V DC to 32 V DC
Test voltage
500 V DC for one minute
Protection against polarity reversal
Present
Current Consumption and Inrush Current
Nominal current consumption
FL SWITCH SFN 5TX-24VAC
114 mA @ 24 V AC
74 mA @ 24 V DC
FL SWITCH SFN 8TX-24VAC
189 mA @ 24 V AC
135 mA @ 24 V DC
FL SWITCH SFN 5TX-24VAC
132 mA @ 20 V AC
139 mA @ 12 V DC
FL SWITCH SFN 8TX-24VAC
214 mA @ 20 V AC
287 mA @ 12 V DC
FL SWITCH SFN 5TX-24VAC
3.83 A @ 24 V AC (750 µs)
5.01 A @ 24 V DC (750 µs)
FL SWITCH SFN 8TX-24VAC
3.92 A @ 24 V AC (750 µs)
4.15 A @ 24 V DC (750 µs)
Maximum, current consumption
Inrush current
Interfaces
Total number of RJ45 Ethernet interfaces
5/8
MAC Address Table Size (Entries)
1K
Properties of RJ45 Ports
Connection format
8-pos. RJ45 female connector on the switch
Connection medium
Twisted-pair cable with a conductor cross section of 0.14 mm2 to 0.22 mm2
Cable impedance
100 Ω
Transmission speed
10/100 Mbps
Maximum network segment length
100 m
Mechanical Tests
Shock test according to IEC 60068-2-27
Operation: 25g, 11 ms period, half-sine shock pulse
Storage/transport: 50g, 11 ms period, half-sine shock pulse
Vibration resistance according to IEC 60068-2-6
Operation/storage/transport: 5g, 150 Hz, Criterion 3
Free fall according to IEC 60068-2-32
1m
Conformance With EMC Directives
Developed according to IEC 61000-6-2
IEC 61000-4-2 (ESD)
Criterion B
IEC 61000-4-3 (radiated-noise immunity)
Criterion A
IEC 61000-4-4 (burst)
Criterion A
IEC 61000-4-5 (surge)
Criterion B
IEC 61000-4-6 (conducted noise immunity)
Criterion A
IEC 61000-4-8 (noise immunity against magnetic fields)
Criterion A
EN 55022 (noise emission)
Class A
Approvals
General
Hazardous location
c u ROHS EEE 2002/95/EC, WEEE 2002/96/EC
U Class 1, Division 2, Groups A, B, C, D Temp Code T6
installed in minimum IP54 enclosure
2686_en_D
PHOENIX CONTACT
3
FL SWITCH SFN…24VAC
5
Overview
6
CAUTION:
1
Only qualified personnel may start up and operate
this device. Qualified personnel are persons
authorized to start up, ground and mark devices,
systems, and equipment according to the
standards of safety technology.
2
2
US
FL SWITCH SFN 5TX-24VAC
Ord.No. 2891020
FL SWITCH SFN 5TX-24VAC
Ord.No. 2891021
3
K/
LN T
AC
X1
10
0
K/
LN T
AC
X1
10
X2
0
10
K/
LN T
AC
X2
X3
X4
0
10
1
00
K/
LN T
AC
K/
LN T
AC
1
K/
LN T
AC
X6
X5
X3
0
00
K/
LN T
AC
K/
LN T
AC
0
10
0
10
10
0
K
LN T
AC
K
LN T
AC
10
K/
LN T
AC
/
K
LN T
AC
X4
0
/
/
10
The FL SWITCH SFN…24VAC module is
designed for SELV and PELV operation
according to IEC 61140/EN 61140.
K/
LN T
AC
0
10
10
1
NOTE:
0
00
K/
LN T
AC
/
K
LN T
AC
10
1
US
K/
LN T
AC
4
0
Install the FL SWITCH SFN…24VAC on a clean mounting
rail. To avoid contact resistance, use only clean, corrosionfree rails that meet the EN 60715 standard. End clamps can
be mounted on both sides of the module to stop the modules
from slipping on the rail.
K/
LN T
AC
X7
X8
0
10
NOTE:
0
10
LNK/ACT
100
1
2
3
4
Figure 1
5.1
Connect the mounting rail to protective earth
ground using a grounding terminal block. The
modules are grounded when they are snapped
onto the rail. Connect protective earth ground
with low impedance.
0
Port X5
Power connector
Power LED (US) - green
LNK/ACT LED
100 LED
6.1
Housing
1.
Diagnostic and Status Indicators
Meaning
2.
ON
Supply voltage (US) in
the tolerance range
3.
OFF
Supply voltage (US) too
low
Des.
Color
Status
US1
green
6.2
1.
5.2
Installation
Data Transmission Speed LEDs (2 LEDs/Port)
10 Mbps
100 Mbps
LNK/ACT
ON/blinking
ON/blinking
100
OFF
ON
2.
3.
Assembly
Place the module onto the rail from above. The upper
holding keyway must be hooked onto the top edge of
the rail.
Push the module from the front towards the mounting
surface.
Once the module has been snapped on properly, check
that it is fixed securely on the rail.
Removal
Insert a suitable tool (e.g., needle-nose pliers) into the
arresting latch and pull it down.
Pull the module slightly away from the mounting
surface.
Lift the module from the rail.
LNK/ACT LED:
ON: indicates an electrical link
Flashing: indicates network traffic (at high data
rates the blinking is in a constant rate)
2686_en_D
PHOENIX CONTACT
4
FL SWITCH SFN…24VAC
6.3
Power Connection
7
The switch is designed for SELV and PELV operation at
24 V AC/DC according to IEC 61140/EN 61140. Only SELV
and PELV according to the defined standards may be used
for supply purposes.
Snapping the switch onto a grounded mounting rail
connects it to the ground potential. In an environment
particularly prone to EMI, noise immunity can be increased
by an additional low-impedance connection to functional
earth ground (see Figure 2).
–
–
+ –
Switching Characteristics
Store and Forward
All data telegrams received by the switch are saved and
their validity checked. Invalid or faulty data packets
(> 1522 bytes or CRC errors) and fragments
(< 64 bytes) are rejected. Valid data telegrams are
forwarded by the switch. The switch always forwards
the data using the data transmission speed that is used
in the destination network segment.
Multi-Address Function
The switch independently learns the addresses for
termination devices, which are connected via a port, by
evaluating the source addresses in the data telegrams.
Only packets with unknown addresses, with a source
address of this port or with a multicast/broadcast
address in the destination address field are forwarded
via the corresponding port. The switch can store
addresses in its address table with an aging time of
5 minutes. This is important when more than one
termination device is connected to one or more ports. In
this way, several independent subnetworks can be
connected to one switch.
US GND
A restart deletes the entire address table.
Figure 2
Power connections
Use power conductors between 0.2 - 2.5 mm²
(24 - 12 AWG). Torque connection screws to 0.5 - 0.6 Nm
(5 - 7 lb-in.).
6.4
Ethernet Interface
The FL SWITCH SFN…24VAC has five/eight Ethernet ports
on the front in RJ45 format to which only twisted-pair cables
with an impedance of 100 Ω can be connected. The data
transmission speed is 10/100 Mbps. In addition, every port
has an auto crossing function: it is not necessary to make a
distinction between 1:1 or crossover Ethernet cables.
–
Quality of Service (QoS): IEEE 802.1P/Q
The FL SWITCH SFN…-24VAC switches are capable
of reading Ethernet packets that have already been
assigned a priority level by a managed switch. In cases
of heavy traffic, packets with a priority level between 4
and 7 are considered high priority and processed
before packets with a priority level between 0 and 3.
After prioritization the packets are forwarded without
modification.
RJ45
8 7 6 5
4 3 2 1
n.c. TDn.c. RDn.c. n.c.
TD+ RD+
Figure 3
2686_en_D
RJ45 pin assignment
PHOENIX CONTACT
5
FL SWITCH SFN…24VAC
8
Dimensions
14 mm
US
FL SWITCH SFN 5TX-24VAC
Ord.No. 2891020
FL SWITCH SFN 5TX-24VAC
Ord.No. 2891021
K/
LN T
AC
X1
X1
10
X2
0
10
0
10
K/
LN T
AC
0
K/
LN T
AC
X3
120 mm
X2
10
10
0
0
K/
LN T
AC
X3
X4
0
10
10
0
K/
LN T
AC
K/
LN T
AC
10
0
0
K/
LN T
AC
K/
LN T
AC
X6
X5
0
10
0
10
/
10
0
K
LN T
AC
K/
LN T
AC
/
K
LN T
AC
X4
10
10
K/
LN T
AC
/
K
LN T
AC
10
1
US
K/
LN T
AC
/
K
LN T
AC
0
/
K
LN T
AC
10
0
K/
LN T
AC
X7
X8
0
10
0
10
LNK/ACT
100
0
Port X5
30 mm
50 mm
Depth = 70 mm
Figure 4
2686_en_D
Housing dimensions
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00
PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300
www.phoenixcontact.com
6