FL SWITCH SFN…24VAC Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housings for 24 V AC Power AUTOMATION Data Sheet 2686_en_D 1 © PHOENIX CONTACT 2009-12 Description 2 The FL SWITCH SFN…-24VAC range of Factory Line switches can be used for quick and cost-effective Ethernet network expansion to the field level. Due to the narrow housing design, the switches are suitable for use in control cabinets and junction boxes. – The FL SWITCH SFN…-24VAC switches support the auto negotiation function on the RJ45 ports and offer transmission speeds of 10/100 Mbps. Mixed operation for the connection of segments with different data transmission speeds is also supported. The RJ45 ports offer an auto crossing function, which means it is not necessary to make a distinction between 1:1 and crossover cables. Unused RJ45 ports can be fitted with security caps to provide mechanical protection against unauthorized use. – – – – – – – – – – – – Features and Benefits Switched Ethernet networks reduce traffic and nonpredictable timing Pretagged high priority messages are forwarded before lower priority messages during periods of high network traffic Auto-negotiation and autocross simplify cabling Couple copper network segments with different bit rates with automatic detection of the data transmission speed of 10 or 100 Mbps Individual LEDs at each port indicate communication activity and data rate -0 to 60°C operating range Removable power connector NS 35 DIN rail (EN 60715) compatible Industrial rated, rugged metal housing for industrial applications Low-cost, low-complexity security by connecting Layer 1 security elements at the RJ45 ports to restrict access and tampering (optional) Meets IEC 61000-6-2 electrical noise immunity Meets IEC 60068-2-6 vibration test standards Meets IEC 60068-2-27 shock test standards Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/catalog. This data sheet is valid for all products listed on the following page: FL SWITCH SFN…24VAC 3 Ordering Data Description Type Order No. Pcs./Pkt. Ethernet switch, with 5 RJ45 ports for 10/100 Mbps FL SWITCH SFN 5TX-24VAC 2891021 1 Ethernet switch, with 8 RJ45 ports for 10/100 Mbps FL SWITCH SFN 8TX-24VAC 2891020 1 Accessories Description Type Order No. Pcs./Pkt. Universal end clamp E/NS 35 N 0800886 50 Patch angle with 2 ports in CAT 5e FL PF 2TX CAT5E 2891165 1 Patch angle with 8 ports in CAT 5e FL PF 8TX CAT5E 2891178 1 Patch angle with 2 ports in CAT 6 FL PF 2TX CAT6 2891068 1 Patch angle with 8 ports in CAT 6 FL PF 8TX CAT6 2891071 1 Patch angle with security elements for 2 ports in CAT 5e FL PF SEC 2TX 2832687 1 Patch angle with security elements for 8 ports in CAT 5e FL PF SEC 8TX 2832690 1 Patchbox 8 x RJ45 CAT 5e, pre-assembled, can be retrofitted FL PBX 8TX 2832496 1 Patch cable, CAT 5, pre-assembled, 0.3 m long FL CAT5 PATCH 0,3 2832250 10 Patch cable, CAT 5, pre-assembled, 0.5 m long FL CAT5 PATCH 0,5 2832263 10 Patch cable, CAT 5, pre-assembled, 1.0 m long FL CAT5 PATCH 1,0 2832276 10 Patch cable, CAT 5, pre-assembled, 1.5 m long FL CAT5 PATCH 1,5 2832221 10 Patch cable, CAT 5, pre-assembled, 2.0 m long FL CAT5 PATCH 2,0 2832289 10 Patch cable, CAT 5, pre-assembled, 3.0 m long FL CAT5 PATCH 3,0 2832292 10 Patch cable, CAT 5, pre-assembled, 5.0 m long FL CAT5 PATCH 5,0 2832580 10 Patch cable, CAT 5, pre-assembled, 7.5 m long FL CAT5 PATCH 7,5 2832616 10 Patch cable, CAT 5, pre-assembled, 10.0 m long FL CAT5 PATCH 10 2832629 10 Security frame for SFN switch and patch fields, green FL PLUG GUARD, GN 2891615 20 Security frame for SFN switch and patch fields, red FL PLUG GUARD, RD 2891712 20 Security frame for SFN switch and patch fields, white FL PLUG GUARD, WH 2891819 20 Security frame for SFN switch and patch fields FL PORT GUARD 2891220 20 Security frame for SFN switch and patch fields FL PLUG GUARD KEY 2891327 1 Security element for FL CAT patch FL PATCH SAFE CLIP 2891246 20 4 Technical Data General Data Function Switch/repeater; conforms to standard IEEE 802.3 Latency of the communication processor 8 µs plus frame time Housing dimensions (width x height x depth) 5-port switch, without connectors 8-port switch, without connectors 30 x 120 x 70 mm 50 x 120 x 70 mm Weight 5-port switch, without connectors 8-port switch, without connectors 277 g 340 g Operating temperature 0°C to 60°C Storage temperature -20°C to 85°C Degree of protection IP20, DIN 40050, IEC 60529 Protection class Class 3 VDE 0106; IEC 60536 Humidity (operation and storage) 5% to 95%, no condensation Air pressure (operation) 86 kPa to 108 kPa, 1500 m above sea level Air pressure (storage) 86 kPa to 108 kPa, 3500 m above sea level Mounting rail NS 35 (EN 60715) Preferred mounting position Perpendicular to a standard rail Connection to protective earth ground Snapped onto a grounded rail 2686_en_D PHOENIX CONTACT 2 FL SWITCH SFN…24VAC Supply Voltage (US) Connection type Removable, spring-cage connector Wire size (solid/stranded/AWG) 0.2 to 2.5 mm² / 0.2 to 2.5 mm² / 24 to 12 AWG Recommended PE wire size 2.5 mm2 Nominal power supply 24 V AC/24 V DC Permissible ripple 3.6 Vpp within the permissible voltage range Permissible voltage range 20 V AC to 28 V AC 12 V DC to 32 V DC Test voltage 500 V DC for one minute Protection against polarity reversal Present Current Consumption and Inrush Current Nominal current consumption FL SWITCH SFN 5TX-24VAC 114 mA @ 24 V AC 74 mA @ 24 V DC FL SWITCH SFN 8TX-24VAC 189 mA @ 24 V AC 135 mA @ 24 V DC FL SWITCH SFN 5TX-24VAC 132 mA @ 20 V AC 139 mA @ 12 V DC FL SWITCH SFN 8TX-24VAC 214 mA @ 20 V AC 287 mA @ 12 V DC FL SWITCH SFN 5TX-24VAC 3.83 A @ 24 V AC (750 µs) 5.01 A @ 24 V DC (750 µs) FL SWITCH SFN 8TX-24VAC 3.92 A @ 24 V AC (750 µs) 4.15 A @ 24 V DC (750 µs) Maximum, current consumption Inrush current Interfaces Total number of RJ45 Ethernet interfaces 5/8 MAC Address Table Size (Entries) 1K Properties of RJ45 Ports Connection format 8-pos. RJ45 female connector on the switch Connection medium Twisted-pair cable with a conductor cross section of 0.14 mm2 to 0.22 mm2 Cable impedance 100 Ω Transmission speed 10/100 Mbps Maximum network segment length 100 m Mechanical Tests Shock test according to IEC 60068-2-27 Operation: 25g, 11 ms period, half-sine shock pulse Storage/transport: 50g, 11 ms period, half-sine shock pulse Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 150 Hz, Criterion 3 Free fall according to IEC 60068-2-32 1m Conformance With EMC Directives Developed according to IEC 61000-6-2 IEC 61000-4-2 (ESD) Criterion B IEC 61000-4-3 (radiated-noise immunity) Criterion A IEC 61000-4-4 (burst) Criterion A IEC 61000-4-5 (surge) Criterion B IEC 61000-4-6 (conducted noise immunity) Criterion A IEC 61000-4-8 (noise immunity against magnetic fields) Criterion A EN 55022 (noise emission) Class A Approvals General Hazardous location c u ROHS EEE 2002/95/EC, WEEE 2002/96/EC U Class 1, Division 2, Groups A, B, C, D Temp Code T6 installed in minimum IP54 enclosure 2686_en_D PHOENIX CONTACT 3 FL SWITCH SFN…24VAC 5 Overview 6 CAUTION: 1 Only qualified personnel may start up and operate this device. Qualified personnel are persons authorized to start up, ground and mark devices, systems, and equipment according to the standards of safety technology. 2 2 US FL SWITCH SFN 5TX-24VAC Ord.No. 2891020 FL SWITCH SFN 5TX-24VAC Ord.No. 2891021 3 K/ LN T AC X1 10 0 K/ LN T AC X1 10 X2 0 10 K/ LN T AC X2 X3 X4 0 10 1 00 K/ LN T AC K/ LN T AC 1 K/ LN T AC X6 X5 X3 0 00 K/ LN T AC K/ LN T AC 0 10 0 10 10 0 K LN T AC K LN T AC 10 K/ LN T AC / K LN T AC X4 0 / / 10 The FL SWITCH SFN…24VAC module is designed for SELV and PELV operation according to IEC 61140/EN 61140. K/ LN T AC 0 10 10 1 NOTE: 0 00 K/ LN T AC / K LN T AC 10 1 US K/ LN T AC 4 0 Install the FL SWITCH SFN…24VAC on a clean mounting rail. To avoid contact resistance, use only clean, corrosionfree rails that meet the EN 60715 standard. End clamps can be mounted on both sides of the module to stop the modules from slipping on the rail. K/ LN T AC X7 X8 0 10 NOTE: 0 10 LNK/ACT 100 1 2 3 4 Figure 1 5.1 Connect the mounting rail to protective earth ground using a grounding terminal block. The modules are grounded when they are snapped onto the rail. Connect protective earth ground with low impedance. 0 Port X5 Power connector Power LED (US) - green LNK/ACT LED 100 LED 6.1 Housing 1. Diagnostic and Status Indicators Meaning 2. ON Supply voltage (US) in the tolerance range 3. OFF Supply voltage (US) too low Des. Color Status US1 green 6.2 1. 5.2 Installation Data Transmission Speed LEDs (2 LEDs/Port) 10 Mbps 100 Mbps LNK/ACT ON/blinking ON/blinking 100 OFF ON 2. 3. Assembly Place the module onto the rail from above. The upper holding keyway must be hooked onto the top edge of the rail. Push the module from the front towards the mounting surface. Once the module has been snapped on properly, check that it is fixed securely on the rail. Removal Insert a suitable tool (e.g., needle-nose pliers) into the arresting latch and pull it down. Pull the module slightly away from the mounting surface. Lift the module from the rail. LNK/ACT LED: ON: indicates an electrical link Flashing: indicates network traffic (at high data rates the blinking is in a constant rate) 2686_en_D PHOENIX CONTACT 4 FL SWITCH SFN…24VAC 6.3 Power Connection 7 The switch is designed for SELV and PELV operation at 24 V AC/DC according to IEC 61140/EN 61140. Only SELV and PELV according to the defined standards may be used for supply purposes. Snapping the switch onto a grounded mounting rail connects it to the ground potential. In an environment particularly prone to EMI, noise immunity can be increased by an additional low-impedance connection to functional earth ground (see Figure 2). – – + – Switching Characteristics Store and Forward All data telegrams received by the switch are saved and their validity checked. Invalid or faulty data packets (> 1522 bytes or CRC errors) and fragments (< 64 bytes) are rejected. Valid data telegrams are forwarded by the switch. The switch always forwards the data using the data transmission speed that is used in the destination network segment. Multi-Address Function The switch independently learns the addresses for termination devices, which are connected via a port, by evaluating the source addresses in the data telegrams. Only packets with unknown addresses, with a source address of this port or with a multicast/broadcast address in the destination address field are forwarded via the corresponding port. The switch can store addresses in its address table with an aging time of 5 minutes. This is important when more than one termination device is connected to one or more ports. In this way, several independent subnetworks can be connected to one switch. US GND A restart deletes the entire address table. Figure 2 Power connections Use power conductors between 0.2 - 2.5 mm² (24 - 12 AWG). Torque connection screws to 0.5 - 0.6 Nm (5 - 7 lb-in.). 6.4 Ethernet Interface The FL SWITCH SFN…24VAC has five/eight Ethernet ports on the front in RJ45 format to which only twisted-pair cables with an impedance of 100 Ω can be connected. The data transmission speed is 10/100 Mbps. In addition, every port has an auto crossing function: it is not necessary to make a distinction between 1:1 or crossover Ethernet cables. – Quality of Service (QoS): IEEE 802.1P/Q The FL SWITCH SFN…-24VAC switches are capable of reading Ethernet packets that have already been assigned a priority level by a managed switch. In cases of heavy traffic, packets with a priority level between 4 and 7 are considered high priority and processed before packets with a priority level between 0 and 3. After prioritization the packets are forwarded without modification. RJ45 8 7 6 5 4 3 2 1 n.c. TDn.c. RDn.c. n.c. TD+ RD+ Figure 3 2686_en_D RJ45 pin assignment PHOENIX CONTACT 5 FL SWITCH SFN…24VAC 8 Dimensions 14 mm US FL SWITCH SFN 5TX-24VAC Ord.No. 2891020 FL SWITCH SFN 5TX-24VAC Ord.No. 2891021 K/ LN T AC X1 X1 10 X2 0 10 0 10 K/ LN T AC 0 K/ LN T AC X3 120 mm X2 10 10 0 0 K/ LN T AC X3 X4 0 10 10 0 K/ LN T AC K/ LN T AC 10 0 0 K/ LN T AC K/ LN T AC X6 X5 0 10 0 10 / 10 0 K LN T AC K/ LN T AC / K LN T AC X4 10 10 K/ LN T AC / K LN T AC 10 1 US K/ LN T AC / K LN T AC 0 / K LN T AC 10 0 K/ LN T AC X7 X8 0 10 0 10 LNK/ACT 100 0 Port X5 30 mm 50 mm Depth = 70 mm Figure 4 2686_en_D Housing dimensions PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 www.phoenixcontact.com 6