TRABTECH Product Range P O W E R M C R • Surge Protection for Power Supply Systems lightning current arresters , surge protection ,special systems , equipment protection • Surge Protection devices for Measurement and Control Technology DIN rail modules :pluggable ,Terminal block LSA-PLUS modules : COMTRAB I T • Surge Protection devices for Information Technology and Telecomunications Ethernet , Serial ,ADSL ,Analog • R F Surge Protection equipment for Transceiver systems. Mobile phone ,Video communication ,Radio and TV P O W E R P O W E R FLT –CP PLUS.... Pluggable class I arrester for TN-C,TN-S,TT,TN-CS systems. Easy maintenance without switching of the supply voltage. 3+1 concept complying with IEC standards. Status display and remote signaling. High power follow current capability. Technical data Protection level : <1.5 kV Iimp (10/350): 100kA IFI (line follow): 50kA per pole IEC class : I (B) Rated voltage Uc: 350V P O W E R FLT –CP... Pluggable class I +II arrester for TN-C,TN-S,TT,TN-CS systems. Encapsulated spark gaps & thermal monitored varistors. Easy maintenance without switching of the power supply. 3+1 concept complying with IEC standards. Status display and remote signaling. Active Energy Control. Technical data Protection level : <1.5 kV Iimp (10/350): 100kA IEC class : I+II (B+C) Rated voltage Uc: 350V P O W E R VAL –CP... Pluggable class II arrester for TN-C,TN-S,TT,TN-CS systems. Thermal monitored varistors. Easy maintenance without switching of the power supply. 3+1 concept complying with IEC standards. Status display and remote signaling. Wide range of products for different power supply systems. Technical data Protection level : <1.4 kV In (8/20): 20kA. Imax (8/20) : 40kA. IEC class : II (C) Rated voltage Uc: 350V P O W E R VAL-MS..350 L-N plugs: 3+1: VAL-MS 350/10 ST VAL-MS 350/10/3+1 VAL-MS 350/20 ST VAL-MS 350/20/3+1 N-PE plugs: 3+1-FM: F-MS 30 ST VAL-MS 350/10/3+1-FM VAL-MS 350/20/3+1-FM 3+0: 1+1: VAL-MS 350/10/3+0 VAL-MS 350/10/1+1 VAL-MS 350/20/3+0 VAL-MS 350/20/1+1 3+0-FM: 1+1-FM: VAL-MS 350/10/3+0-FM VAL-MS 350/10/1+1-FM VAL-MS 350/20/3+0-FM VAL-MS 350/20/1+1-FM P O W E R PT 2-PE/S.. Surge protection for single and three phase power supplies. Signaling on the unit + remote signaling . The varistors are equipped with a thermal monitoring element. Technical data Protection level : <180V (24VAC version) Iimp (8/20): 1kA per pole (24VAC version) IEC class : III (D) Rated voltage Uc: wide range of arresters for different nominal voltages. Nominal current In : 26A/3x16A P O W E R PRT .. Two piece pluggable (outlet + plug) equipment protection for the power supply. Mounted in cable ducts. Acoustic/Visual alarm + remote signaling. Temperature monitored varistors. Technical data Protection level : <1.3kV (230VAC version) In (8/20): 1.5kA IEC class : III (D) Rated voltage Uc: 250V AC Nominal current In : 16A P O W E R BT-SKT 230/A Equipment protection for the power supply. Mounted in installation boxes. Acoustic alarm. Temperature monitored varistors. Technical data Protection level : <1. kV Iimp (8/20): 1.5kA IEC class : III (D) Rated voltage Uc: 260V AC Nominal current In : 16A P O W E R CHECKMASTER Highly efficient and flexible testing system. Testing of pluggable SPD class I /II /III is possible. Easy handling using a bar code scanner and key panel. Full documentation of the tests and RS 232 / USB interface for connection with a printer or a PC. Onsite testing without long downtimes as with laboratory tests. Basically a “must have” tool for SPD without signaling option for faults . Gives a third status of a “recommendation for replacement”. Extensive tests for SPD with multi stage protective circuits. M C R M C R PT 2X2 & PT 1X2 ... One and two circuits for protection of a floating signal on a double conductor. Two stage protection circuit for high surge arresting capacity while maintaining low residual voltage. Direct/indirect connection to local ground to avoid ground current loop. Pluggable for efficient maintenance. Technical data In (8/20): 10kA Iimp (10/350) :2.5kA Residual Voltage at In : ≤40v (PT..24DC) Nominal Voltage : 5,12,24DC 12,24AC Nominal Current : 450mA 1 2 5 6 3 4 9 10 M C R PT PE/S 1X2-24 field PT PE/S+ 1x2-24-ST PHOENIX CONTACT PLUGTRAB PHOENIX CONTACT PLUGTRAB 08.03.01 PT 2-PE/S230AC-ST TT 1297 Mains Class III (D) Measuring transducer OUT PT PE/S+ 1x2-24-ST I 0..20mA 0...20mA IN 24V max. 6A PLUGTRAB Sensor IN OUT PHOENIX CONTACT +24V24V Inst. board 0...20mA L N M C R PT ..Ex(I)-24DC Surge arresters for intrinsically safe circuits. PT 2...Ex.. Protects 2 independent 2 wire circuits. PT 4...Ex.. Protects a signal of 3 or 4 wire measuring technology. Areas of application : zones 0,1,2. Technical data In (8/20): 10kA (PT..2..) Iimp (10/350) : 2.5kA Nominal Voltage :24vDC Nominal Current : 450mA Residual voltage at In : ≤45v (PT..2..) M C R TERMITRAB TT-2-PE , for double conductor floating signal TT-2/2-PE , for 2 conductors with common ground TT-2-PE , for double conductor temperature measurement signal M C R COMTRAB modular Modular Surge arresters for 1-10 double conductors or 2-20 single conductors. Easily mounted on a 10 segment magazine . Protection for floating signal on a double conductor. Operating Protection for 2 conductors with common ground. voltages : 12/24/60vDC 110vAC. Nominal current : 380mA. M C R COMTRAB accessories Grounding rail Disconnect strip Shield fast connection magazine plug TERMIBLOCK Mounting clip I T I T D-LAN ... Protection for all 8 signal paths that are connected to the RJ-45 connector. Designed for Ethernet, Token Ring. Transmission rates up to 1Gbps. Technical data D-LAN CAT 6+ In (8/20): 2kA Nominal Voltage : ≤ 3.3vDC Nominal Current : ≤ 1.5A Protection Level : ≤9v 19 inch rack for protection of 4/8/12/16/20/24 RJ 45 ports. D-LAN 19 Grounding of the housing is possible as direct grounding or via a gas filled arrester. I T WT-RJ45 ... Flush mounted socket for class D( cat 5 /cat 5.e) Ethernet with RJ-45 connection. Can be adapted for Token Ring by using an adapter cable. Technical data In (8/20): 10kA Nominal Voltage : 6.2vDC Nominal Current : 1.5A Residual voltage : ≤30v I T D-UFB ... For RS-SERIAL Protection of data transmission systems with V.11/RS-485. D-sub 9. Two protection stages. Technical data Total surge current (8/20): 5kA Nominal Voltage : 12vDC Nominal Current : 380mA (D-UFB modules) Residual voltage : ≤25v (D-UFB modules) I T D-TELE ... For Analog Telecomunication Protection adapter of Analog Telecomunication. RJ 45 interface also suitable for RJ 11 and RJ 12. Din Rail mountable. Technical data In (8/20): 5kA Nominal Voltage : 185vDC Nominal Current : 380mA Residual Voltage : 120v R F R F CN-UB-280DC Surge protection adapter for mobile phone and radio systems. Replaceable gas discharge arrester (coarse protection). N type connector. Plug-socket / socket-socket. Mountable in the cabinet. Permanent HF Power : 700 700W W Technical data Cut-off , fg : >3GHZ In (8/20): 20kA IEC class : C2,C3,D1 Rated Voltage : 280vDC/195vAC Nominal Current : 5A R F CN-UFB... Surge protection adapter for data and video communication systems. Low capacitance two stage protective circuits with coarse (gas tube) and fine (diodes) protection. Used for communication with low power signals that require low protection level and low capacitance.. BNC connectors for 50Ω and 75Ω. Technical data In (8/20): 10kA IEC class : B1,C2,C3,D1 Residual Voltage at In : ≤10v (C-UFB-5DC/E) Nominal Voltage : 5v/24v R F CN-TV... Surge protection for antenna input of radio and television sets. Located either on the cable or the antenna or the satellite receiver. High discharge currents due to a gas discharge arrester. TV and F connectors . For single device or for antenna distributor (5 F connectors). Technical data In (8/20): 2.5kA IEC class : B2,C1,C2,C3,D1 Residual Voltage at In : ≤30v (C-TV) Nominal Voltage : 180vdc/130vAC (C-TV)