Adjustable IRt/c Models Adjustable IR-TC Sensors

Adjustable IRt/c Models
Adjustable IR-TC Sensors
IRt/c.10A
Quick Selection Guide
These models allow users to calibrate the IRt/c sensors to match a thermocouple output in whatever
temperature range desired. For example: if the requirement is to measure and control a non-metal target in
the 1000 F to 1100 F (540 C to 590 C) range, an IRt/c.10A-K-HiE sensor can be selected. It is then installed
and calibrated, in place, to generate a type K signal for that temperature range.
IRt/c.20A
1.375 dia. (34,9)
1.375 dia. (34,9)
3.34 lg. (84,8)
4.15 lg. (105,4)
IRt/c.100A
1.375 dia. (34,9)
10.45 lg. (265,4)
Approximate scale 1:5 dimensions in inches (mm).
IRt/c ACF models
Close Focus
IRt/c AMF models
Medium Focus
1.7
(43)
IRt/c ALF models
Long Focus
3.0 (76)
4.1 (105)
1.375 dia.
(34,9)
1.375 dia.
(34,9)
1.375 dia.
(34,9)
2.97 lg.
(75,3)
2.02 lg.
(51,3)
3.34 lg. (213)
IRt/c AXLF models
Extra Long Focus
8.0 (203)
1.375 dia.
(34,9)
8.375 lg. (213)
Ordering information: (Model) - (Thermocouple Type) - (HiE or LoE)
Use the Selection Table. Select the model for (1) temperature range (2) spot size, and (3) target surface
material (nonmetal or metal, uncoated). Then finally, (4) select the thermocouple type (J,K, R or S).
Example: IRt/c.10A -K- HiE
Adjustable IRt/c Options
Adjustable IRt/c models are also available, Pre-Calibrated, from Exergen with NIST traceability for quick
multiple same sensor installations for factory automation and OEMs. Also, millivolt signal output curves
and mv tables are available for all sensor models for special calibrations.
C
ASM GmbH
O
R
P
O
R
A
T
I
O
N
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.de
11
IRTC-ADJ-02/2009
1
www.asm-sensor.de
Adjustable Models Selection Table
Adjustable Models selection table
Model
2
C
Temperature Range
°F
°C
Spot Size
Target
Surface
.10A-HiE
J, K
-50 to 2500
-45 to 1370
Distance ÷ 10
Nonmetal
.10A-LoE
J, K
500 to 2500
260 to 1370
Distance ÷ 10
Metal
.20A-HiE
J, K
500 to 3000
260 to 1650
Distance ÷ 20
Nonmetal
.20A-LoE
J, K
1000 to 3500
540 to 1930
Distance ÷ 20
Metal
.100A-HiE
R, S
1000 to 5000
540 to 2760
Distance ÷ 100
Nonmetal
.100A-LoE
R, S
1500 to 5000
820 to 2760
Distance ÷ 100
Metal
.2ACF-HiE
J, K
500 to 2500
260 to 1370
2.9 mm
Nonmetal
.2ACF-LoE
J, K
1000 to 2500
540 to 1370
2.9 mm
Metal
.2/15ACF-HiE
J, K
0 to 2500
-18 to 1370
2.9 x 8.7 mm
Nonmetal
.2/15ACF-LoE
J, K
500 to 2500
260 to 1370
2.9 x 8.7 mm
Metal
.3AMF-Hi E
J, K
500 to 2500
260 to 1370
3.7 mm
Nonmetal
.3AMF-LoE
J, K
1100 to 2500
590 to 1370
3.7 mm
Metal
.4ACF-HiE
J, K
0 to 2500
-18 to 1370
5.0 mm
Nonmetal
.4ACF-LoE
J, K
600 to 2500
320 to 1370
5.0 mm
Metal
.8ACF-LoE
J, K
300 to 2500
150 to 1370
8.5 mm
Metal
.2/18AMF-HiE
J, K
0 to 2500
-18 to 1370
4.5 x 12.8 mm
Nonmetal
.2/18AMF-LoE
J, K
600 to 2500
320 to 1370
4.5 x 12.8 mm
Metal
.6AMF-HiE
J, K
0 to 2500
-18 to 1370
6.5 mm
Nonmetal
.6AMF-LoE
J, K
700 to 2500
370 to 1370
6.5 mm
Metal
.12AMF-LoE
J, K
400 to 2500
200 to 1370
11.1 mm
Metal
.2/15ALF-HiE
J, K
700 to 3000
370 to 1650
3.0 x 7.2 mm
Nonmetal
.2/15ALF-LoE
J, K
1200 to 3500
650 to 1930
3.0 x 7.2 mm
Metal
.4ALF-HiE
J, K
700 to 3000
370 to 1650
4 mm
Nonmetal
.4ALF-LoE
J, K
1300 to 3500
700 to 1930
4 mm
Metal
.7ALF-HiE
J, K
300 to 3000
150 to 1650
7.2 mm
Nonmetal
.7ALF-LoE
J, K
900 to 3500
480 to 1930
7.2 mm
Metal
.2AXLF-HiE
R, S
1100 to 3500
590 to 1930
1.8 mm
Nonmetal
.2AXLF-LoE
R, S
2200 to 3500
1200 to 1930
1.8 mm
Metal
.4AXLF-HiE
R, S
900 to 3500
480 to 1930
4.8 mm
Nonmetal
.4AXLF-LoE
R, S
1700 to 3500
930 to 1930
4.8 mm
Metal
IRTC-ADJ-02/2009
12
T/C
Types
O
R
P
O
R
A
T
I
O
N
51 Water Street, Watertown, MA 02172 USA
Tel.: 08123/986-0
Fax:
08123/986-500
www.asm-sensor.de
800-422-3006
• 617-923-9900
• Fax
617-923-9911
ASM GmbH
Adjustable IR-TC Sensors
Adjustable Models
IRt/c.10A
Range Adjustment Screw: CW to Increase
10:1 Field-of-View
1.375 (34,9) DIA.
AIR PURGE/COOL FITTING
.558 (14,17)
10 X
8.5 (216)
.151 (3,84)
AIR PURGE PATH
1X
1.40 (35,5)
.80 (20) DIA.
.073 (1,85)
3.34 (84,8)
T/C WIRE
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR., MOUNTING SCREWS PROVIDED
IRt/c.20A
Range Adjustment Screw: CW to Increase
20:1 Field-of-View
1.375 (34,9) DIA.
AIR PURGE/COOL FITTING
.558 (14,17)
20 X
17 (432)
.151 (3,84)
AIR PURGE PATH
1X
1.40 (35,5)
.80 (20) DIA.
4.15 (105,4)
.073 (1,85)
T/C WIRE
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR., MOUNTING SCREWS PROVIDED
IRt/c.10A
Target Surface Type
Sensing Range
Optimum Range
Selections
Lo E (metal)
-50 to 2500°F (-45 to
1370°C)
500 to 2500°F (260 to
1370°C)
500 to 3000°F (260 to
1650°C)
1000 to 3500°F (540 to
1930°C)
One model each J, K: adjustable over entire sensing range, output tables available
No Aperture: 0.8" (20 mm) at <16" (400 mm)
½" Aperture: 0.5" (13 mm) at <9" (230 mm)
¼" Aperture: 0.25" (6 mm) at<3.5" (90 mm)
Field-of-View at > min.
spot
10:1 (6°) approximately
20:1 (3°) approximately
Spectral Response
2 to 20 µ
0.1 to 5 µ
2 to 20 µ
0.1 to 5 µ
Output Impedance
6 to 13 Kohms approx
9 to 18 Kohms approx
6 to 13 Kohms approx
9 to 18 Kohms approx
Twisted shielded pair of base thermocouple material (J,K,etc.), 3 ft (.9 m) std length, Teflon sheathed,
rated to 392°F (200°C) continuous service.
Weight
Hi E (non-metal)
No Aperture: 0.8" (20 mm) at <7" (180 mm)
½" Aperture: 0.5" (13 mm) at <3.5" (90 mm)
¼" Aperture: 0.25" (6 mm) at <1" (25 mm)
Dimensions
Lo E (metal)
Minimum Spot Size at
dist. (with supplied
apertures)
Cable
ASM GmbH
IRt/c.20A
Hi E (non-metal)
3.34" x 1.375" Dia. (85 x 35 mm)
4.15" x 1.375" Dia. (105 x 35 mm)
8.0 oz (230 g) with cable
8.7 oz (248 g) with cable
Housing
Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield grounded to
housing and electrically isolated from signal.
Air Purge
Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided
51 Water Street, Watertown, MA 02172 USA
IRTC-ADJ-02/2009 2 3
800-422-3006 • 617-923-9900 • Fax 617-923-9911
C
O
R
P
O
R
A
T
I
O
N
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.de
3
www.asm-sensor.de
Adjustable
Models
Adjustable
IR-TC Sensors
IRt/c.100A
100:1 Field-of-View
Range Adjustment Screw
100 X
1.375 (34,9) DIA.
AIR PURGE/COOL FITTING
.558 (14,17)
.151 (3,84)
80 (2000)
AIR PURGE
1X
T/C
.073 (1,85)
1.40 (35,5)
10.45 (265,4)
.80 (20) DIA.
IRt/c Models
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR., MOUNTING SCREWS PROVIDED
IRt/c.100A
Target Surface Type
Sensing Range
Optimum Range
Selections
Minimum Spot Size
Field-of-View
Spectral Response
Output Impedance
Dimensions
IRTC-ADJ-02/2009
4
C
O
R
P
O
R
A
T
I
Lo E (metal)
1000 to 5000°F (540 to 2760°C)
1500 to 5000°F (820 to 2760°C)
One model each R,S: adjustable over entire sensing range, output tables
available
At distance, with supplied apertures:
No Aperture: 0.8" (20 mm) at <80" (2000 mm)
½" Aperture: 0.5" (13 mm) at <50" (1270 mm)
¼" Aperture: 0.25" (6 mm) at <25" (635 mm)
At > min. spot: 100:1 (0.6°) approximately
2 to 20 µ
0.1 to 5 µ
6 to 13 Kohms approx
9 to 18 Kohms approx
Twisted shielded pair of base thermocouple material (R,S,etc.), 3 ft (.9 m) std
length, Teflon sheathed, rated to 392°F (200°C) continuous service.
Cable
24
Hi E (non-metal)
10.5" x 1.375" Dia. (265 x 35 mm)
Weight
20 oz (570 g) with cable
Housing
Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically
safe, cable shield grounded to housing and electrically isolated from signal.
Air Purge
Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing
provided
O
N
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.de
ASM GmbH
Adjustable Models
Adjustable IR-TC Sensors
IRt/c.2ACF
Close Focus, 0.11" (2.9 mm)
Spot
Range Adjustment Screw
1.375 (34,9) DIA.
AIR PURGE/COOL FITTING
.558 (14,17)
0.11"
(2.9 mm)
Dia
AIR PURGE PATH 1.7 (43)
.151 (3,84)
~30
2.02 (51,3)
.073 (1,85)
T/C WIRE
Spot size is 0.11"
(2.9 mm) at focal
plane. Spot size
increases with
approx 30 deg
included angle
away from focal
plane.
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
IRt/c.2/15ACF
Range Adjustment Screw
1.375 (34,9) DIA.
Lines Indicating Long Axis of View
Spot size
is 0.11 x 0.35"
(2.9 x 8.7 mm)
rectangle at focal
plane. Spot size
increases with
approx 30 deg
included angle
away from focal
plane.
AIR PURGE/COOL FITTING
.558 (14,17)
AIR PURGE PATH 1.7 (43)
.151 (3,84)
o
~30
.073 (1,85)
2.02 (51,3)
T/C WIRE
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
Close Focus
“Slot Spot”
IRt/c.2ACF
Target Surface Type
Sensing Range
Hi E (non-metal)
Lo E (metal)
Hi E (non-metal)
Lo E (metal)
500 to 2500°F (260 to
1370°C)
1000 to 2500°F (540 to
1370°C)
0 to 2500°F (-18 to 1370°C)
500 to 2500°F (260 to
1370°C)
One model each J, K: adjustable over entire sensing range, output tables available
Optimum Range
Selections
Minimum Spot Size
IRt/c.2/15ACF
At focus: 0.11" (2.9 mm) at 1.7" (43 mm) from sensor
Non-focus: 30° approximately
Field-of-View
Spectral Response
Output Impedance
2 to 20 µ
30° approximately
0.1 to 5 µ
Dimensions
Weight
4 to 8 Kohms (varies by model)
0.1 to 5 µ
10 Kohms approx
2.02" x 1.375" Dia. (51.3 x 35 mm)
2.02" x 1.375" Dia. (51.3 x 35 mm)
6.8 oz (192 g) with cable
6.8 oz (192 g) with cable
Housing
Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield grounded to housing
and electrically isolated from signal.
Air Purge
Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided
C
2 to 20 µ
Twisted shielded pair of base thermocouple material (J,K,etc.), 3 ft (.9 m) std length, Teflon sheathed,
rated to 392°F (200°C) continuous service.
Cable
ASM GmbH
0.11 x 0.35" (2.9 x 8.7 mm) at 1.7" (43 mm) from sensor
O
R
P
O
R
A
T
I
O
N
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.de
25
IRTC-ADJ-02/2009
5
www.asm-sensor.de
Adjustable
ModelsIR-TC Sensors
Adjustable
IRt/c.4ACF
Range Adjustment Screw
Close Focus
0.20" (5.0 mm) Spot
1.375 (34,9) DIA.
AIR PURGE/COOL FITTING
.558 (14,17)
0.20"
(5.0 mm)
Dia
AIR PURGE PATH 1.7 (43)
.151 (3,84)
~30o
2.02 (51,3)
.073 (1,85)
T/C WIRE
Spot size is 0.20"
(5.0 mm) at focal
plane. Spot size
increases with
approx 30 deg
included angle
away from focal
plane.
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
IRt/c.8ACF
Close Focus
0.33" (8.5 mm) Spot
Range Adjustment Screw
1.375 (34,9) DIA.
AIR PURGE/COOL FITTING
.558 (14,17)
IRt/c Models
0.33"
(8.5 mm)
Dia
AIR PURGE PATH 1.7 (43)
.151 (3,84)
~30o
2.02 (51,3)
.073 (1,85)
T/C WIRE
Spot size is 0.33"
(8.5 mm) at focal
plane. Spot size
increases with
approx 30 deg
included angle
away from focal
plane.
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
IRt/c.4ACF
Target Surface Type
Hi E (non-metal)
Lo E (metal)
Lo E (metal)
Sensing Range
0 to 2500°F
(-18 to 1370°C)
600 to 2500°F
(320 to 1370°C)
300 to 2500°F
(150 to 1370°C)
One model each J, K: adjustable over entire sensing range, output tables available
Optimum Range
Selections
Minimum Spot Size at
Focus
Field-of-View
(non-focus)
Spectral Response
Output Impedance
IRTC-ADJ-02/2009
6
O
0.33" (8.5 mm) at 1.7" (43 mm) from sensor
30° approximately
30° approximately
2 to 20 µ
0.1 to 5 µ
4 to 8 Kohms (varies by model)
0.1 to 5 µ
10 Kohms approx
2.02" x 1.375" Dia. (51.3 x 35 mm)
Dimensions
C
0.20" (5.0 mm) at 1.7" (43 mm) from sensor
Twisted shielded pair of base thermocouple material (J,K,etc.), 3 ft (.9 m) std length, Teflon
sheathed, rated to 392°F (200°C) continuous service.
Cable
26
IRt/c.8ACF
Weight
6.8 oz (192 g) with cable
Housing
Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield
grounded to housing and electrically isolated from signal.
Air Purge
Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided
R
P
O
R
A
T
I
O
N
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.de
ASM GmbH
Adjustable Models
Adjustable IR-TC Sensors
IRt/c.2/18AMF
Range Adjustment Screw
0.18 (4.5 mm)
1.375 (34,9) DIA.
Lines Indicating Long Axis of View
0.5 (12.8 mm)
AIR PURGE/COOL FITTING
.558 (14,17)
Spot size is 0.18 x 0.5"
4.5 x 12.8 mm)
rectangle at focal plane.
Spot size increases with
approx 13 deg included
angle away from focal
plane.
AIR PURGE PATH 2.76 (70,1)
.151 (3,84)
Medium Focus
“Slot Spot”
~13o
.073 (1,85)
2.97 (75,3)
T/C WIRE
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
IRt/c.3AMF
Range Adjustment Screw
Medium Focus
0.12" (3 mm) Spot
1.375 (34,9) DIA.
Spot size is
0.12" (3 mm)
dia. at focal
plane. Spot size
increases with
approx 13 deg
included angle
away from focal
plane.
AIR PURGE/COOL FITTING
.558 (14,17)
AIR PURGE PATH 2.76 (70,1)
.151 (3,84)
~13o
2.97 (75,3)
T/C WIRE
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
.073 (1,85)
IRt/c.2/18AMF
IRt/c.3AMF
Target Surface Type
Hi E (non-metal)
Lo E (metal)
Hi E (non-metal)
Lo E (metal)
Sensing Range
0 to 2500°F
(-18 to 1370°C)
600 to 2500°F
(320 to 1370°C)
500 to 2500°F
(260 to 1370°C)
1100 to 2500°F
(590 to 1370°C)
One model each J, K: adjustable over entire sensing range, output tables available
Optimum Range
Selections
Minimum Spot Size at
Focus
0.18 x 0.5" (4.5 x 12.8 mm) at 3" (76 mm) from sensor
13° approximately
Field-of-View
(non-focus)
Spectral Response
2 to 20 µ
0.1 to 5 µ
Dimensions
2.97" x 1.375" Dia. (75.3 x 35 mm)
Weight
6.8 oz (192 g) with cable
Housing
Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield grounded to housing and
electrically isolated from signal.
Air Purge
Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided
C
0.1 to 5 µ
Twisted shielded pair of base thermocouple material (J,K,etc.), 3 ft (.9 m) std length, Teflon sheathed,
rated to 392°F (200°C) continuous service.
Cable
2 to 20 µ
10 Kohms approx
Output Impedance
ASM GmbH
0.15" (3.7 mm) at 3" (76 mm) from sensor
O
R
P
O
R
A
T
I
O
N
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.de
27
IRTC-ADJ-02/2009
7
www.asm-sensor.de
Adjustable Models
Adjustable IR-TC Sensors
IRt/c.6AMF
Range Adjustment Screw
Medium Focus
0.26" (6.5 mm) Spot
1.375 (34,9) DIA.
AIR PURGE/COOL FITTING
.558 (14,17)
AIR PURGE PATH 2.76 (70,1)
.151 (3,84)
~13o
Spot size is
0.26" (6.5 mm)
dia. at focal
plane. Spot size
increases with
approx 13 deg
included angle
away from focal
plane.
2.97 (75,3)
T/C WIRE
.073 (1,85)
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
IRt/c.12AMF
IRt/c Models
Range Adjustment Screw
Medium Focus
0.48" (11.1 mm) Spot
1.375 (34,9) DIA.
Spot size is 0.48"
(11,1 mm) dia. at
focal plane. Spot
size increases
with approx 13
deg included
angle away from
focal plane.
AIR PURGE/COOL FITTING
.558 (14,17)
AIR PURGE PATH 2.76 (70,1)
.151 (3,84)
o
~13
2.97 (75,3)
T/C WIRE
.073 (1,85)
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
IRt/c.6AMF
IRt/c.12AMF
Target Surface Type
Hi E (non-metal)
Lo E (metal)
Lo E (metal)
Sensing Range
0 to 2500°F
(-18 to 1370°C)
700 to 2500°F
(370 to 1370°C)
400 to 2500°F
200 to 1370°C)
One model each J, K: adjustable over entire sensing range, output tables available
Optimum Range Selections
Minimum Spot Size at Focus
0.26" (6.5 mm) at 3" (76 mm) from sensor
13° approximately
Field-of-View (non-focus)
2 to 20 µ
Spectral Response
0.1 to 5 µ
0.1 to 5 µ
10 Kohms approx
Output Impedance
Twisted shielded pair of base thermocouple material (J,K,etc.), 3 ft (.9 m) std length, Teflon sheathed, rated to
392°F (200°C) continuous service.
Cable
2.97" x 1.375" Dia. (75.3 x 35 mm)
Dimensions
Weight
6.8 oz (192 g) with cable
Housing
Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield grounded to
housing and electrically isolated from signal.
Air Purge
Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided
28
IRTC-ADJ-02/2009
8
0.48" (11.1 mm) at 3" (76 mm) from sensor
C
O
R
P
O
R
A
T
I
O
N
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.de
ASM GmbH
Adjustable Models
Adjustable IR-TC Sensors
IRt/c.2/15ALF
Range Adjustment Screw
1.375 (34,9) DIA.
Spot size is
0.12 x 0.28"
(3 x 7.2 mm)
rectangle at focal
plane. Spot size
increases with
approx 11 deg
inlcluded angle
away from focal
plane.
Lines Indicating Long Axis of View
AIR PURGE/COOL FITTING
.558 (14,17)
AIR PURGE PATH
.151 (3,84)
4.1 (105)
~11 o
3.34 (84,8)
.073 (1,85)
Long Focus
“Slot Spot”
T/C WIRE
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
IRt/c.4ALF
Range Adjustment Screw
Long Focus
0.14" (3.5 mm) Spot
1.375 (34,9) DIA.
AIR PURGE/COOL FITTING
AIR PURGE PATH
.151 (3,84)
IRt/c Models
.558 (14,17)
4.1 (105)
~11 o
3.34 (84,8)
.073 (1,85)
Spot size is 0.14
(3.5 mm) dia. at focal
plane. Spot size
increases with approx
11 deg included angle
away from focal plane.
T/C WIRE
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
IRt/c.2/15ALF
IRt/c.4ALF
Target Surface Type
Hi E (non-metal)
Lo E (metal)
Hi E (non-metal)
Lo E (metal)
Sensing Range
700 to 3000°F
(370 to 1650°C)
1200 to 3500°F
(650 to 1930°C)
700 to 3000°F
(370 to 1650°C)
1200 to 3500°F
(700 to 1930°C)
Optimum Range
Selections
Minimum Spot Size at
Focus
One model each J, K: adjustable over entire sensing range, output tables available
0.12 x 0.28" (3 x 7.2 mm) at 4.1" (105 mm) from
sensor
11° approximately
Field-of-View
(non-focus)
Spectral Response
2 to 20 µ
0.1 to 5 µ
Dimensions
3.34" x 1.375" Dia. (84.8 x 35 mm)
Weight
8.7 oz (248 g) with cable
Housing
Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield
grounded to housing and electrically isolated from signal.
Air Purge
Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided
C
0.1 to 5 µ
Twisted shielded pair of base thermocouple material (J,K,etc.), 3 ft (.9 m) std length, Teflon
sheathed, rated to 392°F (200°C) continuous service.
Cable
2 to 20 µ
10 Kohms approx
Output Impedance
ASM GmbH
0.14" (35 mm) at 4.1" (105 mm) from sensor
O
R
P
O
R
A
T
I
O
N
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.de
29
IRTC-ADJ-02/2009
9
www.asm-sensor.de
Adjustable
Adjustable
ModelsIR-TC Sensors
IRt/c.7ALF
Long Focus
0.3" (7 mm) Spot
Range Adjustment Screw
1.375 (34,9) DIA.
AIR PURGE/COOL FITTING
.558 (14,17)
AIR PURGE PATH
.151 (3,84)
4.1 (105)
~11 o
3.34 (84,8)
.073 (1,85)
Spot size is 0.28" (7.2 mm) dia.
at focal plane. Spot size increases
with approx 11 deg inlcluded
angle away from focal plane.
IRt/c Models
T/C WIRE
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
IRt/c.7ALF
Target Surface Type
Hi E (non-metal)
Lo E (metal)
Sensing Range
300 to 3000°F
(150 to 1650°C)
900 to 3500°F
(480 to 1930°C)
Optimum Range Selections
One model each J, K: adjustable over entire sensing range, output tables available
Minimum Spot Size at Focus
0.28" (7.2 mm) at 4.1" (105 mm) from sensor
11° approximately
Field-of-View (non-focus)
Spectral Response
2 to 20 µ
0.1 to 5 µ
10 Kohms approx
Output Impedance
Twisted shielded pair of base thermocouple material (J,K,etc.), 3 ft (.9 m) std length, Teflon sheathed
rated to 392°F (200°C) continuous service.
Cable
3.34" x 1.375" Dia. (84.8 x 35 mm)
Dimensions
30
IRTC-ADJ-02/2009
10
Weight
8.7 oz (248 g) with cable
Housing
Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield
grounded to housing and electrically isolated from signal.
Air Purge
Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided
C
O
R
P
O
R
A
T
I
O
N
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.de
ASM GmbH
Adjustable IR-TC Sensors
Adjustable Models
IRt/c.2AXLF
Range Adjustment Screw
1.375 (34,9) DIA.
AIR PURGE/COOL FITTING
AIR PURGE PATH
.558 (14,17)
Extra Long Focus
0.07" (1.8 mm) Spot
8.0 (203)
~ 5o
.151 (1,85)
8.375 (213)
.073 (1,85)
T/C WIRE
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
.151 (3,84)
Spot size is 0.07 (1.8 mm)
dia. at focal plane. Spot
size increases with approx
5 deg included angle away
from focal plane.
IRt/c.4AXLF
Range Adjustment Screw
1.375 (34,9) DIA.
Extra Long Focus
0.19" (4.8 mm) Spot
8.0 (203)
IRt/c Models
AIR PURGE/COOL FITTING
AIR PURGE PATH
.558 (14,17)
~ 5o
.151 (1,85)
8.375 (213)
.073 (1,85)
T/C WIRE
#10-32 MOUNTING HOLES ON A 1.0" (25,4) DIA BOLT CIR.,
MOUNTING SCREWS PROVIDED
.151 (3,84)
Spot size is 0.14 (3.5 mm)
dia. at focal plane. Spot
size increases with approx
5 deg included angle away
from focal plane.
IRt/c.2AXLF
IRt/c.4AXLF
Target Surface Type
Hi E (non-metal)
Lo E (metal)
Hi E (non-metal)
Lo E (metal)
Sensing Range
1100 to 3500°F
(590 to 1930°C)
2200 to 3500°F
(1200 to 1930°C)
900 to 3500°F
(480 to 1930°C)
1700 to 3500°F
(930 to 1930°C)
Optimum Range
Selections
Minimum Spot Size at
Focus
One model each R, S: adjustable over entire sensing range, output tables available
0.07" (1.8 mm) at 8" (200 mm) from sensor
5° approximately
Field-of-View
(non-focus)
Spectral Response
2 to 20 µ
0.1 to 5 µ
Dimensions
8.375" x 1.375" Dia. (213 x 35 mm)
Weight
20 oz (570 g) with cable
Housing
Stainless steel, hermetically sealed, exceeds NEMA 4,4x; IP65,67, intrinsically safe, cable shield
grounded to housing and electrically isolated from signal.
Air Purge
Built-in; cooling capacity to 400°F (200°C) ambient; 3' (0.9 m) polyurethane tubing provided
C
0.1 to 5 µ
Twisted shielded pair of base thermocouple material (J,K,etc.), 3 ft (.9 m) std length, Teflon
sheathed, rated to 392°F (200°C) continuous service.
Cable
2 to 20 µ
10 Kohms approx
Output Impedance
ASM GmbH
0.19" (4.8 mm) at 8" (200 mm) from sensor
O
R
P
O
R
A
T
I
O
N
51 Water Street, Watertown, MA 02172 USA
800-422-3006 • 617-923-9900 • Fax 617-923-9911
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.de
31
IRTC-ADJ-02/2009
11
ASM GmbH
Am Bleichbach 18 - 22
85452 Moosinning
Deutschland
Tel. +49-(0)8123-986-0 Fax +49-(0)8123-986-500
[email protected] www.asm-sensor.de
© by ASM GmbH Moosinning. Änderungen und Irrtümer vorbehalten. Schutzvermerk DIN34 beachten.
02.2009