SA1-0505 LF-Spec-X0-120913_BHUSA

SA1-0505 LF
1 Watt Single Output SMD DC-DC Converter
Features :
2.
3.
1.1.
Low Ripple and Noise
1.2.
Input / Output Isolation :1000 Vdc
1.3.
100 % Burn-In
1.4.
Net Weight : 1.5 g Typical
1.5.
RoHS Converter Certified By SGS
Input Specifications :
2.1.
Input Voltage
: 4.5–5.5 Vdc
5 Vdc ±10 %
2.2.
Max. Input Current
: 282 mA Max.
@ Vin = 5 Vdc and Output at Full Load.
2.3.
Quiescent Current
: 33 mA Typical
@ Vin = 5 Vdc and No Load.
2.4.
Input Ripple
: 100 mV Typical
2.5.
Input Filter
: Internal Capacitor
2.6.
Switching Frequency
: 100 KHz Typ.
@ Vin = 5 Vdc and Output at Full Load.
2.7.
Input Efficiency
: 71% Min.
@ Vin = 5 Vdc and 100 % Load. ( 75% Typical )
@ Vin = 5 Vdc ,Output at Full Load ,No Input
Electrolytic Capacitor and 20 MHz BW.
Output Specification :
3.1.
Output Voltage
: 5 Vdc
3.2.
Output Voltage Accuracy
: ±5%
3.3.
Max. Output Current
: 200 mA
3.4.
Min. Output Current
: 20 mA
3.5.
Ripple
: 60 mVp-p Max.
3.6.
Line Regulation
: 1.2 %/ 1.0 %
3.7.
Load Regulation
: 15 %
3.8.
Max. Capacitive Load
: 220
3.9.
Temperature Coefficient
: ± 0.02 %/℃
@ Vin = 5 Vdc and Output at Full Load.
@ 20 MHz BW
Max. See Note (1).
Max.
See Note (2).
uF
Note :
(1). Line Regulation : Set output load to full load, Then adjust input voltage from 4.5 Vdc to 5.5 Vdc (10% change), The
output voltage difference must be within 12% of the output at full load and nominal input.
(2). Load Regulation : Set input voltage at 5 Vdc, Then changing the load current from 10 % to 100 % Max. Load. The
output voltage difference must be within 15 % of the output at full load and nominal input.
(3). All specification are typical at 25℃ unless otherwise state.
4.
General Specification :
4.1.
Isolation Voltage
: 1000 Vdc
Test duration 60 Seconds / 0.5 mA
4.2.
Isolation Resistance
: 1000 MΩ Min.
@ 500 Vdc
4.3.
Operating Temperature (1)
: -40℃ ~ +85℃
@ Ambient Temperature with Natural convention
4.4.
Operating Temperature (2)
: -40℃ ~ +95℃
@ Case Surface Temperature
4.5.
Storage Temperature
: -55℃ ~ +125℃
4.6.
Humidity
: Up to 90 %
4.7.
Cooling
: Free air convection
4.8.
Case Type
: Non-Conductive Plastic
4.9.
Safety Standard / Approval
: IEC /EN 60950-1
Bothhand USA
SA1-0505 LF-Spec-X0-120913
Page 1 of 7
SA1-0505 LF
5.
1 Watt Single Output SMD DC-DC Converter
Mechanical Dimension :
12.80
[0.50]
Pin
SA1-0505 LF
8.40
[0.33]
11.40
[0.45]
Date Code
Units : mm (inch)
Tolerance : 0.xx ± 0.25(0.xx ±0.01)
1 KVdc - Single
Pin
NC
14
1
-Vin
3
+Vin
12
--2.54 5.08
[0.10] [0.20]
8.15
[0.32]
5.90
[0.23]
1.70
[0.07]
7.60
[0.30]
0.08 .003
1.50
[0.06]
---
7
Vo (-)
0.25 [0.01]
0.60 [0.02]
6.
5
10
8
Vo (+)
Note:“---” means Omitted
0.82 [0.03]
Recommended footprint details :
NC
+Vo
14
8
Top View
1
3
7
-Vin +Vin
-Vo
13.1
[0.52]
Units : mm (inch)
12.2
8.7
[0.48]
[0.34]
1.2
[0.05]
Tolerance : 0.xx ± 0.25 ( 0.xx ± 0.01)
1.75
[0.07]
(Top View)
Efficiency & Output Load Chart :
Output Load (mA)
Bothhand USA
SA1-0505 LF-Spec-X0-120913
Page 2 of 200
180
140
160
120
100
80
0
20
90
80
70
60
50
40
30
20
10
0
60
8.
40
Power Derating Curve :
Efficiency %
7.
SA1-0505 LF
1 Watt Single Output SMD DC-DC Converter
Application note
Test Configurations :
All specifications are typical at nominal input, full load and 25°C unless otherwise stated.
A
A
DC
Power Supply
V
DC/DC
converter
V
Load
◎ DC Power Supply: It offers a wide voltage and current range precisely.
◎ Current meter (A): Accuracy 200µA ~ 200mA 4 ranges+(0.2% rdg + 2 digits)
2000mA ~ 20A 2 ranges+(0.3% rdg + 2 digits).
◎ Voltage meter (V): Accuracy +(0.03% rdg + 4 digits).
◎ Load: At full load.
◎ Wires: The resistance of the wires must be small.
1. Input voltage range: Narrow input voltage range(±10%)
、wide input voltage range (2:1 and
4:1)
。
EX: Narrow input voltage range(±10%)
5VDC nominal input 4.5~5.5VDC
12VDC nominal input 10.8~13.2VDC
24VDC nominal input 21.6~26.4VDC
Wide input voltage range 2:1
5VDC nominal input 4.5~9VDC
12VDC nominal input 9~18VDC
24VDC nominal input 18~36VDC
48VDC nominal input
36~75VDC
Wide input voltage range 4:1 (W)
24VDC nominal input 9~36VDC
48VDC nominal input 18~75VDC
2. Input power :
Pin = Vin x Iin
Vin:Input voltage
Iin:Input current
3. Output power :
Pout = Vout x Iout
Vout:Output voltage
Iout:Output current
Bothhand USA
SA1-0505 LF-Spec-X0-120913
Page 3 of SA1-0505 LF
1 Watt Single Output SMD DC-DC Converter
4. Efficiency :
Efficiency =
Pout x100%
Pin
Pout: Output power
Pin: Input power
5. Voltage accuracy:
│Vout-Vout(nominal)│
│ x100%
Vout
Vout:Output voltage
Vout(nominal):Nominal output voltage
6. Line regulation: (1) Wide input voltage range and regulated output voltage series.
││││
││││
│Vout(LL)-Vout(HL)│
│ x100%
Vout(LL)
LL: Low Line input voltage
HL: High Line input voltage
(2) Narrow input voltage range(±10%)and unregulated output voltage series.
Line regulation=
ΔVout
ΔVin
ΔVout = Vout(+10%)-Vout(-10%) x100%
Vout
Vout(+10%):Output voltage at Vin = 1.1xVin(nominal)&full load
Vout(-10%):Output voltage at Vin = 0.9xVin(nominal)&full load
Vout:Output voltage at Vin = Vin(nominal)&full load
ΔVin =
Vin(+10%)-Vin(-10%)
x100%
Vin(nominal)
Vin(+10%):Input voltage = 1.1xVin(nominal)
Vin(-10%):Input voltage = 0.9xVin(nominal)
Vin(nominal):Nominal Input voltage
7. Load regulation :
│Vout(FL)-Vout(NL)│
│ x100%
Vout(FL)
Vout(FL): Output voltage at full load
Vout(NL): Output voltage at 25% full load or 10% full load
Bothhand USA
SA1-0505 LF-Spec-X0-120913
Page 4 of SA1-0505 LF
1 Watt Single Output SMD DC-DC Converter
8. Ripple and Noise: as shown below. The bandwidth is 0-20MHz.
Ripple&Noise
Noise
Ripple
Output Ripple&Noise measurement test circuit: as shown below.
Copper strip
DC/DC
converter
Co
Oscilloscope
Load
Copper strip
Co: usually 0.47uF.
9. Temperature derating curve: The DC-DC converter will operate over a wider temperature
range if less power is drawn from the output and the device is already running. The
temperature derating curve shows the operating power-temperature range. As shown below.
120
100
Output
Power
(%)
80
60
40
20
0
-40
-20
0
20
40
60
80
100
120
Ambient Temp.TA ( ℃ )
10. Switching frequency: The nominal operating frequency of the DC-DC converters.
11.Input to output isolation: The dielectric breakdown strength test between input and
output circuits. This is the isolation voltage the device is capable of withstanding for a
specified time, usually 1 second or 1 minute.
Bothhand USA
SA1-0505 LF-Spec-X0-120913
Page 5 of SA1-0505 LF
1 Watt Single Output SMD DC-DC Converter
Pb-free SMD Peakage AIR Reflow Profile
Step#
Profile Feature
Condition / Duration
Step1
Ramp-up rate
3℃/sec max
Step2
Preheat : 150~200℃
Ta-Tb: 60-180 sec
Ramp-up rate (TL to Tp)
3℃/sec max
Temperature maintained above217℃ (TL)
tL:60-150sec
Peak temperature (Tp)
245+0℃/-5℃
The Time of Actual peak temperature
20-40sec
Ramp-down rate
6℃/sec max
Step3
Step4
Step5
Note1
All temperatures refer to topside of the package, measured on the package body surface.
Note2 Time 25℃ to peak temperature: 8 minutes max
Note3 It is not allowed to make a forced cooling in temperature falling range.
Bothhand USA
SA1-0505 LF-Spec-X0-120913
Page 6 of SA1-0505 LF
1 Watt Single Output SMD DC-DC Converter
8.40±0.10
R eel:
1 7.80±0.10
Package
30.4±2.00
.5
0
4.00±0.10
.1
0/
-0
Date Code
+0
SA1-0505 LF
50
Date Code
1.
SA1-0505 LF
O
O 33
9.6
24.00±0.30
11.50±0.10
8.7
2.00±0.10
1.75±0.10
13.10±0.10
20.00±0.10
0M
IN
12.10±0.10
O1
0.40±0.05
24.4+2/-0
347
82
347
Inner Carton :347*347*82mm
Export Carton:375*375*460m m
1 、P ackaging Num ber of 13":350PCS/R
2 、Inner Carton=1 R=1*350=350PCS
3 、Export Carton=5 Inner Carton=5*350=1750PCS
Tube:
Bothhand USA
SA1-0505 LF-Spec-X0-120913