BUB15 Series -- 15 Watt
Bothhand USA
Features
Wide 2 : 1 Input Voltage Range(9~18V,18~36V,36~75V)
Remote On/Off
Input / Output Isolation Voltage: 1.5K VDC
Extended Operating Temperature Range: -40°C to+85°C
Output Short Circuit Protection:
Description
Hiccup, continuous & Auto Recovery
The BUB15 Series are isolated 15W DC/DC converters.
Over Voltage Protection: Clamp Mode
Designed with highly efficiency, allow the operating temperature
Shielded Metal Case with Insulated Baseplate
range of these units to be -40°C to +85°C in a 6 pin DIP package
with industry-standard footprint. Further features include wide 2 :
Lead Free Design, RoHS Compliant
1 input voltage range, remote on/off control, short-circuit
6 pin DIP Package with Industry-Standard Footprint
protection and over voltage protection.
Customer Design Available
Applications
Safety Standard / Approval : IEC / EN 60950-1
These converters are well suitable for battery operated
equipment, measurement equipment, telecom, wireless
network, Industry control system, everywhere where isolated,
tightly regulated voltages and compact size are required.
Technical Specification
Model
Number
Input Voltage
Range
All specifications are typical at nominal input, full load and 25°C unless otherwise stated.
Output
Voltage
(V)
Output Current (mA)
Min. Load
(1)
Input Current (mA)
Full. Load
No Load
Full Load
Eff .
(%)
Capacitive
(3)
Load, max.
(uF)
(2)
BUB15-12S0
3.3
0
4000
64
1425
81
28000
BUB15-12S1
5
0
3000
89
1565
84
17760
1498
12
24
1250
91
87
3680
15
38
1000
87
1482
88
2104
BUB15-12D1
±5
0
±1500
83
1547
85
10080
BUB15-12D2
±12
±18
±625
88
1491
88
1920
BUB15-12D3
±15
0
±500
90
1484
88
1064
BUB15-24S0
3.3
0
4000
27
691
84
38320
BUB15-24S1
5
0
3000
31
768
85
19360
BUB15-24S2
12
0
1250
33
732
89
3784
15
28
1000
30
725
90
2288
BUB15-24D1
±5
0
±1500
30
753
87
10288
BUB15-24D2
±12
0
±625
32
730
90
1600
BUB15-24D3
±15
0
±500
31
727
90
1144
BUB15-48S0
3.3
0
4000
12
353
82
36560
BUB15-48S1
5
0
3000
15
387
85
20560
BUB15-48S2
12
0
1250
15
368
89
4320
15
24
1000
15
364
90
2368
BUB15-48D1
±5
0
±1500
16
380
86
8800
BUB15-48D2
±12
0
±625
16
368
89
1760
BUB15-48D3
±15
0
±500
16
365
90
1144
BUB15-12S2
BUB15-12S3
BUB15-24S3
BUB15-48S3
9~18V
Nominal:12V
18~36V
Nominal:24V
36~75V
Nominal:48V
[email protected]
www.bothhandusa.com
Rev:20130813 A
Page 1 of 7
Isolated DC-DC Converters
BUB15 Series -- 15 Watt
Bothhand USA
Input Specifications
Input Voltage
12V nominal input
9-18V
24V nominal input
18-36V
48V nominal input
36-75V
Input filter
Pi Type
Input surge voltage
12V nominal input
25Vdc
(100ms max.)
24V nominal input
50Vdc
48V nominal input
100Vdc
Input reflected ripple current
Nominal Vin and full load
Start up time
Nominal Vin and constant resistive load
Remote ON/OFF
100mAp-p max.
80ms typ.
Open or 3.5V<Vr<12V
Converter: ON
Short
Converter: OFF
(4)
or 0V<Vr<0.5V
Sourcing current of remote control pin
Nominal Vin
<0.2 mA
Idle input current (at Remote OFF state)
Nominal Vin
<15 mA
Environmental Specifications
-40°C to +85°C (with derating)
Operating ambient temperature
+100°C
Maximum case temperature
-55°C to +105°C
Storage temperature range
5% to 95% RH
Relative humidity
±0.02% / °C max.
Temperature coefficient
Output Specifications
15 Watts max.
Output power
Voltage accuracy
Full load and nominal Vin
±1%
See table
Minimum load
Line regulation
LL to HL at full load
25% load to full load
Load Regulation
Balanced load
±1%
Single
±0.5%
Dual
±0.5%
Unbalanced load 25% to 100% full load
Ripple and Noise
±5%
20MHz bandwidth
80mVp-p max.
3.3Vout models
3.9V
Over voltage protection
5Vout models
6.2V
(Zener Diode Clamp)
12Vout models
15V
15Vout models
18V
See table
Capacitive load
Over load protection
% of full load at nominal input
Short circuit protection
150% typ.
Hiccup, continuous (Auto Recovery)
Transient response settling time
50% load step change
1000uS max.
Transient response over shoot
di/dt=0.8A/µs
≤ ±5% of Vo
[email protected]
www.bothhandusa.com
Rev:20130813 A
Page 2 of 7
Isolated DC-DC Converters
BUB15 Series -- 15 Watt
Bothhand USA
General Specifications
Efficiency
Nominal input
Isolation voltage
Input to output
Isolation resistance
See table
1500VDC
9
500VDC
10 Ohms min.
Isolation capacitance
550pF typ.
Switching frequency
330kHz typ.
6
Reliability, calculated MTBF
1.58× 10 Hrs
Physical Specifications
Case material
Nickel-coated copper
Base material
Non-conductive black plastic
Silicon rubber (UL94V-0)
Potting material
2.0 × 1.0 × 0.4 Inch
Dimensions
(50.8 × 25.4 × 10.2 mm)
Weight
32.0g (1.13oz) typ.
BUB15 Series
Output Power (%)
Power Derating Curve(5)
Ambient Temp.TA (℃)
[email protected]
Efficiency (%)
BUB15-48S1
Output Current vs. Efficiency
Efficiency (%)
BUB15-48S1
Input voltage vs. Efficiency
www.bothhandusa.com
Rev:20130813 A
Page 3 of 7
Isolated DC-DC Converters
BUB15 Series -- 15 Watt
Bothhand USA
Input voltage (V)
Output Current (A)
BUB15-48S1
BUB15-48S1
Transient Response at 50%~100% Max Load
Loop Gain & Phase at Vi=48V,Full Load
Note
1. Io below this value will not damage these converters, however, they may not meet all listed specifications.
2. Typical value, tested at nominal input and full load.
3. For each output.
4. Short to -Vin (Pin 2).
5. Based on BUB15-48S1.
Mechanical Dimensions
Pin
1
2
3
4
5
6
Pin Assignment
Single
Dual
+Vin
+Vin
-Vin
-Vin
+Vout
+Vout
Trim
Common
-Vout
-Vout
Remote On/Off Remote On/Off
(optional)
(optional)
Unit: mm [inch]
Tolerance:±0.5[0.02]
[email protected]
www.bothhandusa.com
Rev:20130813 A
Page 4 of 7
Isolated DC-DC Converters
BUB15 Series -- 15 Watt
Bothhand USA
Specifications subject to change without noticed.
Test Configurations
All specifications are typical at nominal input, full load and 25°C unless otherwise stated.
A
A
DC
Power Supply
DC/DC
converter
V
V
Load
◎DC Power Supply: It offers a wide voltage and current range precisely.
◎Current meter (A): Accuracy 200μA ~ 200mA 4 ranges+(0.2% rdg + 2 digits)
2000mA ~ 20A
2 ranges+(0.3% rdg + 2 digits).
◎Voltage meter (V): Accuracy +(0.03% rdg + 4 digits).
◎Load: At full load.
◎Wires: The resistance of the wires must be small.
1. Input voltage range: Narrow input voltage range(±10%)、wide input voltage range (2:1 and 4:1)。
EX: Narrow input voltage range(±10%)
5V nominal input 4.5~5.5V
12V nominal input 10.8~13.2V
24V nominal input 21.6~26.4V
Wide input voltage range 2:1
5V nominal input 12V nominal input 24V nominal input 48V nominal input 4.5~9V
9~18V
18~36V
36~75V
Wide input voltage range 4:1 (W)
24V nominal input 9~36V
48V nominal input 18~75V
2. Input power :
Pin = Vin x Iin
Vin:Input voltage
Iin:Input current
Pout = Vout x Iout
Vout:Output voltage
Iout:Output current
3. Output power :
4. Efficiency :
Efficiency =
Pout
Pin
x100%
Pout: Output power
Pin: Input power
5. Voltage accuracy:
│
│Vout-Vout(nominal)│
Vout
[email protected]
x100%
Vout:Output voltage
Vout(nominal):Nominal output voltage
www.bothhandusa.com
Rev:20130813 A
Page 5 of 7
Isolated DC-DC Converters
BUB15 Series -- 15 Watt
Bothhand USA
││││
││││
6. Line regulation: (1) Wide input voltage range and regulated output voltage series.
│Vout(LL)-Vout(HL)│
│
Vout(LL)
LL: Low Line input voltage
HL: High Line input voltage
x100%
(2) Narrow input voltage range(±10%)and unregulated output voltage series.
Δ Vout
Line regulation=
Δ Vin
ΔVout = Vout(+10%)-Vout(-10%) x100%
Vout
Vout(+10%):Output voltage at Vin = 1.1xVin(nominal)&full load
Vout(-10%):Output voltage at Vin = 0.9xVin(nominal)&full load
Vout:Output voltage at Vin = Vin(nominal)&full load
ΔVin = Vin(+10%)-Vin(-10%) x100%
Vin(nominal)
Vin(+10%):Input voltage = 1.1xVin(nominal)
Vin(-10%):Input voltage = 0.9xVin(nominal)
Vin(nominal):Nominal Input voltage
7. Load regulation :
│ x100%
│Vout(FL)-Vout(NL)│
Vout(FL)
Vout(FL): Output voltage at full load
Vout(NL): Output voltage at 25% full load or 10% full load
8. Ripple and Noise: as shown below. The bandwidth is 0-20MHz.
Ripple&Noise
Noise
Ripple
[email protected]
www.bothhandusa.com
Rev:20130813 A
Page 6 of 7
Isolated DC-DC Converters
BUB15 Series -- 15 Watt
Bothhand USA
Output Ripple&Noise measurement test circuit: as shown below.
Copper strip
DC/DC
converter
Co
Oscilloscope
Load
Copper strip
Co: usually 0.47uF.
9. Temperature derating curve: The DC-DC converter will operate over a wider temperature range if less power is
Output Power (%)
drawn from the output and the device is already running. The temperature derating curve shows the operating
power-temperature range. As shown below.
Ambient Temp.TA (℃)
10. Switching frequency: The nominal operating frequency of the DC-DC converters.
11. Input to output isolation: The dielectric breakdown strength test between input and output circuits. This is the
isolation voltage the device is capable of withstanding for a specified time, usually 1 second or 1 minute.
[email protected]
www.bothhandusa.com