BYB100-48S5 20120906

PRELIMINARY
Isolated DC-DC Converters
BYB100-48S5
Bothhand USA
Features
Wide 2 : 1 Input Voltage Range
High Power Density
High Efficiency
Operating Temperature Range: -40°C to +85°C
(with derating)
Output Short Circuit Protection:
Hiccup, continuous & Auto Recovery
Output Over Voltage Protection
Over Temperature Protection
Applications
Fixed Switching Frequency
Distributed power system
Input/ Output Isolation 1500VDC
Telecommunication application
Lead Free Design, RoHS Compliant
Battery powered equipment
Industry Standard Pinout
Industrial application
Adjustable Output Voltage
Process control equipment
Transportation equipment
Input Specifications
Input voltage range
36~75V
Under voltage shutdown
Full Load
33V (typical)
Input current
Vin=48V and no Load
90mA (typical)
Input current
Vin=48V and full Load
2367mA (typical)
Input current
Vin=48V and output shorted
10mA (typical)
Converter: ON
Open or 3.5V<Vr<12V
Converter: OFF
Short(2) or 0V<Vr<1.2V
Sourcing current of remote control pin
Nominal Vin
<0.2mA
Idle input current (at Remote OFF state)
Nominal Vin
<20mA
Remote ON/OFF
Output Specifications
Output voltage
Output voltage accuracy
24V
Vout=23.76 ~ 24.24V
±1%
Maximum Load
4.2A
Minimum Load
0A
Maximum capacitive load
1750uF (maximum)
Efficiency
Vin=48V and full load
92% (typical)
Ripple / Noise
20MHz bandwidth.
200mVp-p (maximum)
±0.02%/℃ (maximum)
Temperature coefficient
Output short circuit protection
Automatic recovery
Output over voltage protection
[email protected]
Hiccup, Continuous
27V (typical)
www.bothhandusa.com
Rev:20120906A
Page 1 of 3
PRELIMINARY
Isolated DC-DC Converters
BYB100-48S5
Bothhand USA
Line regulation
LL to HL at full load
±0.5% (maximum)
Load regulation
25% load to full load
±0.5% (maximum)
Transient response over shoot
di/dt=0.8A/µs
≤ ±5% of Vo
Transient response settling time
50% load step change
240µs (typical)
Start-up time
Nominal Vin and full load
70msec (typical)
Dynamic Characteristics
Switching frequency
300kHz (typical).
General Specifications
4
≧8.8×10 hours
Reliability, calculated MTBF
Operating ambient temperature
-40℃~+85℃
With derating
Maximum case surface temperature
105℃
Thermal shutdown
110°C typ.
Storage temperature range
-55℃~+125 ℃
Relative humidity
95% RH (maximum)
Isolation voltage
Input to output
15000VDC
Isolation capacitance
Input to output
1200pF (typical)
Isolation resistance
Input to output (500VDC)
10 Ω (minimum)
Cooling
Natural convection
9
Physical Specifications
Case material
Aluminum
Potting material
Silicon rubber (UL94V-0)
2.40 × 2.28 × 0.5 Inch
Dimensions
(61.0 × 57.9 × 12.7 mm)
Weight
97g (3.42oz) (typical)
Soldering temperature
Lead-free wave soldering
260℃/10Sec (maximum)
Note
1. Typical value, tested at nominal input and full load.
2. Short to -Vin (Pin 2).
Power Derating Curve
120
100
80
60
40
20
0
-40
-20
0
20
40
50
60
80
100
120
Ambient Temp.TA (℃
℃)
[email protected]
www.bothhandusa.com
Rev:20120906A
Page 2 of 3
PRELIMINARY
Isolated DC-DC Converters
BYB100-48S5
Bothhand USA
Mechanical Dimensions
Pin Assignment
Pin
Single
1
-Vin
2
Case
Remote On/Off
3
4
+Vin
5
-Vout
6
-Sense
7
Trim
8
+Sense
9
+Vout
4-M3x0.5
(Through hole)
1
2
5
Bottom view
6
7
3
8
4
9
Pin 5&9 diameter: 2.0 [0.08]
Other pins diameter: 1.0 [0.04]
Unit: mm [inch]
Tolerance: ±0.5 [0.02]
[email protected]
www.bothhandusa.com
Rev:20120906A
Page 3 of 3
PRELIMINARY
Isolated DC-DC Converters
BYB100-48S5
Bothhand USA
Remote Sense Application circuit
The Remote Sense function is used to compensate for the voltage drop incurred when the load is located physically
far away from the DC/DC converter providing its power. The Remote Sense pins are connected as close to the load as
possible. The DC/DC converter’s regulation specification is maintained across the points where the Remote Sense wires
are connected at the load. This will remove the effect of the voltage drop caused by the resistance of the wires used to
conduct the power from the DC/DC converter to the load. This is represented by RCL1 and RCL2. With the use of Remote
Sense, the effects of RCL1 and RCL2 are eliminated.
If the Remote Sense function is not used, the +Sense has to be connected to +Vout and the –Sense has to be
connected to –Vout as close to the DC/DC converter as possible.
RCL1
+Vout
+Vin
+Sense
Load
-Vin
-Sense
-Vout
RCL1 and RCL2 are line resisters
[email protected]
www.bothhandusa.com
RCL2
Rev:20120906A
Page 4 of 3