AWC6340H HELP CDMA Band Class 0,10 CDMA Power Amplifier Module TM DATA SHEET - Rev 2.1 FEATURES • CDMA/EVDO Compliant •HELPTM technology • High Efficiency (RC-1 waveform): AWC6340 H • 36 % @ POUT = +28.0 dBm • 17 % @ POUT = +15.5 dBm • Low Quiescent Current: 13 mA • Low Leakage Current in Shutdown Mode: <6 µA • Internal Voltage Regulator • Integrated “daisy chainable” directional coupler with CPLIN and CPLOUT port. • Internal DC Blocks on all RF ports 10 Pin 3 mm x 3 mm x 0.9 mm Surface Mount Module • Optimized for a 50 Ω System • 1.8V Control Logic • RoHS Compliant Package, 260 oC MSL-3 APPLICATIONS • Band Class 0, 10 CDMA/EVDO Wireless Devices GND at Slug (pad) PRODUCT DESCRIPTION The AWC6340H is a HELP TM product for CDMA VBATT devices operating in Band Class 0 and 10. This PA incorporates ANADIGICS’ HELP™ technology to deliver exceptional efficiency at low power levels and RFIN low quiescent current without the need for external voltage regulators or converters. The device is manufactured using advanced InGaP HBT technology offering state-of-the-art reliability, temperature stability, GND and ruggedness. Two selectable bias modes that optimize efficiency for different output power levels and a shutdown mode with low leakage current increase VMODE handset talk and standby time. A “daisy chainable” directional coupler is integrated in the module thus eliminating the need of an external coupler. The selfcontained 3 mm x 3 mm x 0.9 mm surface mount VEN package incorporates matching networks optimized for output power, efficiency, and linearity in a 50 Ω system. 05/2013 1 10 2 VCC 9 RFOUT 8 CPLIN 4 7 GND 5 6 CPLOUT 3 CPL Bias Control Voltage Regulation Figure 1: Block Diagram AWC6340H VBATT 1 10 RFIN 2 9 RFOUT GND 3 8 CPLIN VMODE 4 7 GND VEN 5 6 CPLOUT Figure 2: Pinout (X-ray Top View) Table 1: Pin Description 2 PIN NAME DESCRIPTION 1 VBATT Battery Voltage 2 RFIN RF Input 3 GND Ground 4 VMODE Mode Control Voltage 5 VEN 6 CPLOUT 7 GND Ground 8 CPLIN Coupler Input 9 RFOUT RF Output 10 VCC PA Enable Voltage Coupler Output Supply Voltage DATA SHEET - Rev 2.1 05/2013 VCC AWC6340H ELECTRICAL CHARACTERISTICS Table 2: Absolute Minimum and Maximum Ratings PARAMETER MIN MAX UNIT Supply Voltage (VCC) 0 +5 V Battery Voltage (VBATT) 0 +6 V Control Voltages (VMODE, VEN) 0 +3.5 V RF Input Power (PIN) - +10 dBm -40 +150 °C Storage Temperature (TSTG) Stresses in excess of the absolute ratings may cause permanent damage. Functional operation is not implied under these conditions. Exposure to absolute ratings for extended periods of time may adversely affect reliability. Table 3: Operating Ranges PARAMETER MIN TYP MAX UNIT COMMENTS Operating Frequency (f) 816 - 849 MHz BC0, BC10 Supply Voltage (VCC) +3.1 +3.4 +4.35 V POUT ≤ +28 dBm Enable Voltage (VEN) +1.35 0 +1.8 - +3.1 +0.5 V PA "on" PA "shut down" Mode Control Voltage (VMODE) +1.35 0 +1.8 - +3.1 +0.5 V Low Bias Mode High Bias Mode 27.5(1) 26.9 - 28 27.7 15.5 - dBm -30 - +90 C CDMA Output Power HPM HPM LPM Case Temperature (TC) BC0 CDMA 2000, RC1 BC10 The device may be operated safely over these conditions; however, parametric performance is guaranteed only over the conditions defined in the electrical specifications. Note: (1) For operation at 3.1 V, POUT is derated by 0.8 dB. 3 DATA SHEET - Rev 2.1 05/2013 AWC6340H Table 4: Electrical Specifications - CDMA2000 Operation BC0 (RC-1 waveform) (TC = +25 °C, VBATT = VCC = +3.4 V, VENABLE = +1.8 V, 50 Ω system) PARAMETER MIN TYP MAX UNIT Gain 25.5 13.5 28 16 31 20 Adjacent Channel Power at ±885 kHz offset (1) Primary Channel BW = 1.23 MHZ Adjacent Channel BW = 30 kHz - -49 -54 Adjacent Channel Power at ±1.98 MHz offset (1) Primary Channel BW = 1.23 MHZ Adjacent Channel BW = 30 kHz - COMMENTS POUT VMODE dB +28 dBm +15.5 dBm 0V 1.8 V -46 -46 dBc +28 dBm +15.5 dBm 0V 1.8 V -59 -61 -56.5 -56.5 dBc +28 dBm +15.5 dBm 0V 1.8 V 32 - 37 18 - % +28 dBm +15.5 dBm 0V 1.8 V Quiescent Current (Icq) Low Bias Mode - 13 20 mA through VCC pin 1.8 V Mode Control Current - 0.06 0.15 mA through VMODE pin, VMODE = 1.8 V Enable Current - 0.06 0.15 mA through VEN pin, VMODE = 1.8 V BATT Current - 2.5 4.5 mA through VBATT pin, VMODE = +1.8 V Leakage Current - 6 15 µA VBATT = +4.35 V, VCC = +4.35 V, VEN = 0 V, VMODE = 0 V Noise in Receive Band - -134 - dBm/Hz Harmonic 2fo 3fo, 4fo - -40 -50 - dBc Coupling Factor - 20 - dB Coupler IN_OUT Daisy Chain Insertion Loss - <0.25 - dB 698 MHz to 2620 MHz Pin 8-6, Shutdown Mode Efficiency (1) Spurious Output Level (all spurious outputs) Load mismatch stress with no permanent degradation or failure - - -70 dBc POUT ≤ +28 dBm In-band Load VSWR < 5:1 Out-of-band Load VSWR < 10:1 Applies over all operating conditions 8:1 - - VSWR Applies over all operating conditions Notes: (1) ACLR and Efficiency measured at 836.5 MHz. 4 POUT ≤ +28 dBm DATA SHEET - Rev 2.1 05/2013 AWC6340H APPLICATION INFORMATION To ensure proper performance, refer to all related Application Notes on the ANADIGICS web site: http://www.anadigics.com Shutdown Mode The power amplifier may be placed in a shutdown mode by applying logic low levels (see Operating Ranges table) to the VEN and VMODE voltages. The Bias Control table below lists the recommended modes of operation for various applications. Two operating modes are recommended to optimize current consumption. HighBias/High Power operating mode is for Pout levels >16 dBm. At about 16 dBm, the PA should be “Mode Switched” to Low Power Mode. Bias Modes The power amplifier may be placed in either Low or High Bias modes by applying the appropriate logic level (see Operating Ranges table) to the VMODE pin. Vcontrols Venable/Vmode(s) On Sequence Start T_0N = 0µ Rise/Fall Max 1µS Defined at 10% to 90% of Min/Max Voltage Off Sequence Start T_0FF = 0µ ON Sequence OFF Sequence RFIN notes 1,2 VEN VCC note 1 T_0N+1µS T_0N+3µS T_0FF+2µS T_0FF+3µS Referenced After 90% of Rise Time Referenced Before10% of Fall Time Figure 3: Recommended ON/OFF Timing Sequence Notes: (1) Level might be changed after RF is ON. (2) RF OFF defined as PIN ≤ -30 dBm. (3) Switching simultaneously between VMODE and VEN is not recommended. Table 5: Bias Control POUT LEVELS BIAS MODE VEN VMODE VCC VBATT Low power ≤ +16 dBm Low +1.8 V +1.8 V 3.1 - 4.35 V > 3.1 V High power > +16 dBm High +1.8 V 0V 3.1 - 4.35 V > 3.1 V - Shutdown 0V 0V 3.1 - 4.35 V > 3.1 V APPLICATION Shutdown 5 DATA SHEET - Rev 2.1 05/2013 AWC6340H VBATT VCC C2 2.2 µF C1 33 pF GND at slug 1 2 RFIN VMODE1 VCC RFIN RFOUT 10 9 GND CPLIN 8 4 VMODE GND 7 5 VEN 3 VEN VBATT CPLOUT 6 Figure 4: Evaluation Board Schematic 6 DATA SHEET - Rev 2.1 05/2013 C3 330 pF C5 C4 0.01 µF 2.2 µF ceramic RFOUT CPLIN CPLOUT AWC6340H PACKAGE OUTLINE Figure 5: Package Outline - 10 Pin 3 mm x 3 mm x 0.9 mm Surface Mount Module Pin 1 Identifier Date Code (YYWW) 6340H LLLLNN YYWWCC Part Number Lot Number Country Code(CC) Figure 6: Branding Specification - M45 Package 7 DATA SHEET - Rev 2.1 05/2013 AWC6340H PCB AND STENCIL DESIGN GUIDELINE Figure 7: Recommended PCB Layout Information 8 DATA SHEET - Rev 2.1 05/2013 AWC6340H COMPONENT PACKAGING Pin 1 Figure 8: Carrier Tape Figure 9: Reel 9 DATA SHEET - Rev 2.1 05/2013 AWC6340H ORDERING INFORMATION ORDER NUMBER TEMPERATURE RANGE PACKAGE DESCRIPTION COMPONENT PACKAGING AWC6340HQ7 -30 oC to +90 oC RoHS Compliant 10 Pin 3 mm x 3 mm x 0.9 mm Surface Mount Module Tape and Reel, 2500 pieces per Reel AWC6340HP9 -30 oC to +90 oC RoHS Compliant 10 Pin 3 mm x 3 mm x 0.9 mm Partial Tape and Reel Surface Mount Module ANADIGICS 141 Mount Bethel Road Warren, New Jersey 07059, U.S.A. Tel: +1 (908) 668-5000 Fax: +1 (908) 668-5132 URL: http://www.anadigics.com IMPORTANT NOTICE ANADIGICS, Inc. reserves the right to make changes to its products or to discontinue any product at any time without notice. The product specifications contained in Advanced Product Information sheets and Preliminary Data Sheets are subject to change prior to a product’s formal introduction. Information in Data Sheets have been carefully checked and are assumed to be reliable; however, ANADIGICS assumes no responsibilities for inaccuracies. ANADIGICS strongly urges customers to verify that the information they are using is current before placing orders. warning ANADIGICS products are not intended for use in life support appliances, devices or systems. Use of an ANADIGICS product in any such application without written consent is prohibited. 10 DATA SHEET - Rev 2.1 05/2013