SL3C4CLGH - LM79 Report

FOR THE SCOPE OF
ACCREDITATION UNDER NVLAP LAB
CODE 100402-0.
REPORT
3933 US ROUTE 11
CORTLAND, NEW YORK 13045
Project No. G100547181
Date: December 1, 2011
REPORT NO. 100547181CRT-002
TEST OF ONE LED ROADWAY LUMINAIRE
FIXTURE MODEL NO. SL3C4CLGH
RENDERED TO
DIALIGHT CORPORATION
1501 ROUTE 34 SOUTH
FARMINGDALE, NJ 08005
TEST:
Electrical and Photometric tests as required to the IESNA test standard.
LABORATORY NOTE: The laboratory that conducted the testing detailed in this report has been Qualified,
Verified, and Recognized for LM-79 Testing for ENERGY STAR for SSL by US
DOE's CALiPER program.
STATEMENT OF LIMITATION: This report must not be used by the client to claim product certification,
approval, or endorsement by NVLAP, NIST, or any agency of the federal
government.
AUTHORIZATION:
The testing performed was authorized by signed quote number 500337248.
STANDARDS USED:
The following American National Standards or Illuminating Engineering Society of
North America Test Guides were used in part or totally to test each specimen:
IESNA LM-79: 2008
Approved Method for Electrical and Photometric Measurements of Solid-State
Lighting Products
ANSI NEMA ANSLG C78.377: 2008 Specifications of the Chromaticity of Solid State Lighting Products
DESCRIPTION OF SAMPLE:
The client submitted one sample of model number SL3C4CLGH. The
sample was received by Intertek on October 24, 2011, in undamaged
condition, and one sample was tested as received. The sample designation
was D237040-1.
DATES OF TESTS:
October 28, 2011 through November 15, 2011.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are
limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss,
expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test
results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek
certification program. Measurement uncertainty budgets have been determined for applicable test methods and are available upon request.
SUMMARY
Model No.:
Description:
SL3C4CLGH
LED Roadway Luminaire
Criteria
Total Lumen Output
Total Power
Luminaire Efficacy
Power Factor
Current ATHD
Correlated Color Temperature (CCT)
Color Rendering Index (CRI) - Ra
Color Rendering Index (CRI) - R9
Duv
Chromaticity Coordinate (x)
Chromaticity Coordinate (y)
Chromaticity Coordinate (u’)
Chromaticity Coordinate (v’)
Backlight Rating:
Uplight Rating:
Glare Rating:
Result
4702 Lumens
60.30 W
77.98
0.937
14.69%
6081 K
71.9
-12.4
0.005
0.320
0.340
0.199
0.475
B1
U1
G1
EQUIPMENT LIST
Model Number
Control
Number
Last
Calibration
Date
Leeds & Northup Standard Resistor
Data Precision Digital Voltmeter
Fluke Multimeter
Fluke Temperature Meter
Kikusui DC Power Supply
Sorenson DC Power Supply
Manganin
3600
45
53 II
35-10L
DLM150-20E
Y089
V124
M133
T1318
E160
--
02/17/11
02/17/11
02/17/11
02/25/11
-----
NIST Spectral Flux Standard Source
RF1024
---
09/18/10
WT1600
W/ CDS 1100
CW1251
WT210
6440
445703
E462
N307
-E464
-T1425
06/22/11
w/use
-04/19/11
w/use
09/28/11
Equipment Used
Yokogawa Power Analyzer
ITS 3 Meter Sphere
Elgar AC Power Supply
Yokogawa Power Meter
LSI High Speed Mirror Goniometer
Cole Parmer Hygro Thermometer
Report No. 100547181CRT-002
page 2 of 9
Calibration
Due Date
02/17/12
02/17/12
02/17/12
02/25/12
----100 hours of
use
06/22/12
w/use
-04/19/12
w/use
09/28/12
Date: December 1, 2011
TEST METHODS
Seasoning in Sample Orientation – LED Products
No seasoning was performed in accordance with IESNA LM-79.
Photometric and Electrical measurements – Distribution Method
A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at
each angle of distribution for each sample.
Ambient temperature was measured equal to the height of the sample mounted on the Goniometer
equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was
allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements
including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer.
Some graphics were created with Photometrics Plus software.
Photometric and Electrical Measurements – Integrating Sphere Method
A Labsphere Model CDS 1100 CCD Array Spectroradiometer and Two Meter or Ten Foot Sphere was used to
measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL
unit.
Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client
provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize
for at least thirty minutes before measurements were made. Electrical measurements including voltage,
current, and power were measured using the Xitron or Yokogawa Power Analyzer.
The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of
Standards and Technology.
Estimated Total Operating Time
Model No.
SL3C4CLGH
Report No. 100547181CRT-002
Total Hours
5
page 3 of 9
Date: December 1, 2011
TEST METHODS (cont’d)
BUG Ratings (Backlight, Uplight, Glare) – for Outdoor Fixtures Only
Zonal Lumens were calculated and grouped using the formula in IESNA TM-15-11 for each zone as defined in
the BUG addendum. The maximum lumen rating in each zone was compared against the BUG zonal
requirements of Energy Star.
RATING TABLE: BACKLIGHT
NOTE: MAX RATING IN ANY ZONE = RATING FOR LUMINAIRE
BH
BM
BL
B0
110
220
110
B1
500
1000
500
B2
1000
2500
1000
B3
2500
5000
2500
B4
5000
8500
5000
B5
>5000
>8500
>5000
RATING TABLE: UPLIGHT
NOTE: MAX RATING IN ANY ZONE = RATING FOR LUMINAIRE
UH
UL
U0
0
0
U1
10
10
U2
50
50
U3
500
500
U4
1000
1000
U5
>1000
>1000
GLARE RATINGS
NOTE: MAX RATING IN ANY ZONE = RATING FOR LUMINAIRE
FVH
BVH
FH
BH
FVH
BVH
FH
BH
G0
10
10
660
110
FOR ASYMMETRICAL LUMINAIRE TYPES (I, II, III, IV)
G1
G2
G3
G4
G5
100
225
500
750
>750
100
225
500
750
>750
1800
5000
7500
12000
>12000
500
1000
2500
5000
>5000
FOR QUADRILATERAL SYMMETRICAL LUMINAIRE TYPES (V, VSQUARE)
G0
G1
G2
G3
G4
G5
10
100
225
500
750
>750
10
100
225
500
750
>750
660
1800
5000
7500
12000
>12000
660
1800
5000
7500
12000
>12000
Report No. 100547181CRT-002
page 4 of 9
Date: December 1, 2011
RESULTS OF TESTS
Spectral Distribution over Visible Wavelengths
nm
mW/nm
nm
350
355
360
365
370
375
380
385
390
395
400
405
410
415
420
425
430
435
440
445
450
455
0.811
0.687
0.649
0.670
0.606
0.594
0.597
0.697
0.751
0.917
1.226
1.979
3.575
7.251
14.627
27.320
45.034
67.276
97.057
118.117
101.025
66.566
460
465
470
475
480
485
490
495
500
505
510
515
520
525
530
535
540
545
550
555
560
565
mW/nm
nm
SL3C4CLGH
44.412
570
31.513
575
22.976
580
17.803
585
15.461
590
15.068
595
16.523
600
20.417
605
26.576
610
33.669
615
41.084
620
47.859
625
53.960
630
58.290
635
61.655
640
63.641
645
64.931
650
65.526
655
65.758
660
65.503
665
64.797
670
64.174
675
mW/nm
nm
mW/nm
62.882
61.345
59.783
57.700
55.240
52.625
50.023
47.087
44.050
40.971
37.941
34.937
31.896
29.107
26.416
23.925
21.529
19.267
17.179
15.314
13.738
12.163
680
685
690
695
700
705
710
715
720
725
730
735
740
745
750
755
760
765
770
775
780
10.794
9.560
8.461
7.482
6.628
5.811
5.131
4.538
4.011
3.508
3.092
2.728
2.393
2.120
1.862
1.667
1.493
0.000
1.147
1.042
0.913
Dialight Corporation
Sample No. D237040-1
Model No. SL3C4CLGH
Spectral Data Over Visible Wavelengths
140.000
(mW/nm)
120.000
100.000
80.000
60.000
40.000
20.000
0.000
350
400
450
500
550
600
650
700
750
800
Nanometers
Report No. 100547181CRT-002
page 5 of 9
Date: December 1, 2011
RESULTS OF TESTS (cont’d)
Photometric and Electrical Measurements at 25°C – I ntegrating Sphere Method
Intertek
Sample No.
Correlated
Color
Temperature
(K)
CRI
-Ra
CRI
-R9
D237040-1
6081
71.9
-12.4
Intertek
Sample No.
D237040-1
CIE 31’
Chromaticity
Coordinate
DUV
(x)
SL3C4CLGH
0.005
0.320
UP
CIE 76’
Chromaticity
Coordinate
(u’)
CIE 76’
Chromaticity
Coordinate
(v’)
0.340
0.199
0.475
Input
Current
(mA)
Input
Power
(Watts)
Input
Power
Factor
Current
ATHD
(%)
SL3C4CLGH
277.0
233.7
60.46
0.934
14.69
Input
Voltage
(Vac)
Base
Orientation
CIE 31’
Chromaticity
Coordinate
(y)
Photometric and Electrical Measurements – Distribution Method
Intertek
Sample No.
Base
Orientation
D237040-1
UP
Input Voltage Input Current Input Power Input Power
(Vac)
(mA)
(Watts)
Factor
Absolute
Luminous
Flux
(Lumens)
Lumen
Efficacy
(Lumens Per
Watt)
SL3C4CLGH
232.1
60.30
4702
77.98
277.0
0.937
Intensity (Candlepower) Summary at 25°C - Candelas
Angle
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
523
527
642
915
1075
1376
1478
1532
1701
1527
1321
1328
1080
1033
336
142
32
9
4
2
0
0
22.5
45
SL3C4CLGH
523
523
541
535
654
602
869
743
1161 1055
1387 1385
1498 1458
1491 1376
1415 1334
1366 1256
1472 1413
1466 1702
1390 1842
1468 1733
1017 1844
419
1146
73
310
40
42
9
17
3
6
0
1
0
0
Report No. 100547181CRT-002
67.5
90
523
527
564
648
863
1264
1299
1309
1306
1187
1091
1395
1732
1832
1602
1962
1224
186
29
6
2
1
523
523
536
544
566
796
1157
1240
1292
1471
1278
1251
1290
1475
1541
1250
1173
17
3
2
2
1
page 6 of 9
Date: December 1, 2011
RESULTS OF TESTS (cont’d)
Illumination Plots
Model No.: SL3C4CLGH
Mounting Height: 25 ft.
Illuminance - Cone of Light
Isoillumination Plot
Zonal Lumen Summary and Percentages at 25°C
Zone
0-30
0-40
0-60
60-90
0-90
90-180
0-180
Lumens
SL3C4CLGH
650.7
1243
2849
1849
4698
4.2
4702
% Luminaire
Lumens
SL3C4CLGH
51.7
186.5
412.5
591.9
724.4
881.6
1008
722.8
118.0
% Luminaire
13.8
26.4
60.6
39.3
99.9
0.1
100.0
Zonal Lumens and Percentages at 25°C
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
Report No. 100547181CRT-002
page 7 of 9
1.1
4.0
8.8
12.6
15.4
18.7
21.4
15.4
2.5
Date: December 1, 2011
RESULTS OF TESTS (cont’d)
BUG Rating (Backlight, Uplight, Glare)
Zone
Total
Lumens
Frontlight
Category
0-30
30-60
60-80
80-90
90-100
100-180
651
2198
1731
118
4
1
FL
FM
FH
FVH
Frontlight Backlight
Lumens Category
SL3C4CLGH
432
BL
1603
BM
1278
BH
80
BVH
Backlight
Lumens
Uplight
Category
Uplight
Lumens
219
595
453
38
----UL
UH
----4
1
Backlight Rating: B 1
Uplight Rating: U 1
Glare Rating: G 1
Report No. 100547181CRT-002
page 8 of 9
Date: December 1, 2011
Picture (not to scale)
CONCLUSION
The results tabulated in this report are representative of the actual test samples submitted for this report only.
The data is provided to the client for further evaluation. Compliance to the referenced specification
requirements was not determined in this report.
In Charge Of Tests:
Report Reviewed By:
Joseph Schledorn
Engineer
Lighting Division
Jeffery Davis
Senior Associate Engineer
Lighting Division
Attachment: None
Report No. 100547181CRT-002
page 9 of 9
Date: December 1, 2011