SL4N4HLGH - LM79 Report

REPORT
3933 US ROUTE 11
FOR THE SCOPE OF
ACCREDITATION UNDER NVLAP LAB
CODE 100402-0.
CORTLAND, NEW YORK 13045
Project No. G100445508
Date: October 3, 2011
REPORT NO. 100445508CRT-006
TEST OF ONE LED ROADWAY LUMINAIRE
FIXTURE MODEL NO. SL4N4HLGH
RENDERED TO
DIALIGHT CORPORATION
1501 ROUTE 34 SOUTH
FARMINGDALE, NJ 07727
TEST:
Electrical and Photometric tests as required to the IESNA test standard.
LABORATORY NOTE: The laboratory that conducted the testing detailed in this report has been Qualified,
Verified, and Recognized for LM-79 Testing for ENERGY STAR for SSL by US
DOE's CALiPER program.
STATEMENT OF LIMITATION: This report must not be used by the client to claim product certification,
approval, or endorsement by NVLAP, NIST, or any agency of the federal
government.
AUTHORIZATION:
The testing performed was authorized by signed quote number 500314298.
STANDARDS USED:
The following American National Standards or Illuminating Engineering Society of
North America Test Guides were used in part or totally to test each specimen:
IESNA LM-79: 2008
Approved Method for Electrical and Photometric Measurements of Solid-State
Lighting Products
ANSI NEMA ANSLG C78.377: 2008 Specifications of the Chromaticity of Solid State Lighting Products
DESCRIPTION OF SAMPLE:
The client submitted one sample of model number SL4N4HLGH. The
sample was received by Intertek on August 26, 2011, in undamaged
condition, and one sample was tested as received. The sample designation
was D234589-1.
DATES OF TESTS:
September 16, 2011 through September 20, 2011.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are
limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss,
expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test
results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek
certification program. Measurement uncertainty budgets have been determined for applicable test methods and are available upon request.
SUMMARY
Model No.:
Description:
SL4N4HLGH
LED Roadway Luminaire
Criteria
Total Lumen Output
Total Power
Luminaire Efficacy
Power Factor
Current ATHD
Correlated Color Temperature (CCT)
Color Rendering Index (CRI) - Ra
Color Rendering Index (CRI) - R9
Duv
Chromaticity Coordinate (x)
Chromaticity Coordinate (y)
Chromaticity Coordinate (u’)
Chromaticity Coordinate (v’)
Backlight Rating:
Uplight Rating:
Glare Rating:
Result
8092 Lumens
120.5 W
67.15
0.950
14.90%
4580 K
77.6
1.1
0.002
0.359
0.367
0.215
0.494
B2
U1
G2
EQUIPMENT LIST
Model Number
Control
Number
Last
Calibration
Date
Leeds & Northup Standard Resistor
Data Precision Digital Voltmeter
Fluke Multimeter
Fluke Temperature Meter
Kikusui DC Power Supply
Sorenson DC Power Supply
Manganin
3600
45
53 II
35-10L
DLM150-20E
Y089
V124
M133
T1318
E160
--
02/17/11
02/17/11
02/17/11
02/25/11
-----
NIST Spectral Flux Standard Source
RF1024
---
09/18/10
WT1600
W/ CDS 1100
CW1251
WT210
6440
445703
E462
N307
-E464
-T1357
06/22/11
w/use
-04/19/11
w/use
10/12/10
Equipment Used
Yokogawa Power Analyzer
ITS 3 Meter Sphere
Elgar AC Power Supply
Yokogawa Power Meter
LSI High Speed Mirror Goniometer
Cole Parmer Hygro Thermometer
Report No. 100445508CRT-006
page 2 of 8
Calibration
Due Date
02/17/12
02/17/12
02/17/12
02/25/12
----100 hours of
use
06/22/12
w/use
-04/19/12
w/use
10/12/11
Date: October 3, 2011
TEST METHODS
Seasoning in Sample Orientation – LED Products
No seasoning was performed in accordance with IESNA LM-79.
Photometric and Electrical measurements – Distribution Method
A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at
each angle of distribution for each sample.
Ambient temperature was measured equal to the height of the sample mounted on the Goniometer
equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was
allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements
including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer.
Some graphics were created with Photometrics Plus software.
Photometric and Electrical Measurements – Integrating Sphere Method
A Labsphere Model CDS 1100 CCD Array Spectroradiometer and Two Meter or Ten Foot Sphere was used to
measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL
unit.
Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client
provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize
for at least thirty minutes before measurements were made. Electrical measurements including voltage,
current, and power were measured using the Xitron or Yokogawa Power Analyzer.
The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of
Standards and Technology.
Estimated Total Operating Time
Model No.
SL4N4HLGH
Report No. 100445508CRT-006
Total Hours
4
page 3 of 8
Date: October 3, 2011
TEST METHODS (cont’d)
BUG Ratings (Backlight, Uplight, Glare) – for Outdoor Fixtures Only
Zonal Lumens were calculated and grouped using the formula in IESNA TM-15-11 for each zone as defined in
the BUG addendum. The maximum lumen rating in each zone was compared against the BUG zonal
requirements of Energy Star.
RATING TABLE: BACKLIGHT
NOTE: MAX RATING IN ANY ZONE = RATING FOR LUMINAIRE
BH
BM
BL
B0
110
220
110
B1
500
1000
500
B2
1000
2500
1000
B3
2500
5000
2500
B4
5000
8500
5000
B5
>5000
>8500
>5000
RATING TABLE: UPLIGHT
NOTE: MAX RATING IN ANY ZONE = RATING FOR LUMINAIRE
UH
UL
U0
0
0
U1
10
10
U2
50
50
U3
500
500
U4
1000
1000
U5
>1000
>1000
GLARE RATINGS
NOTE: MAX RATING IN ANY ZONE = RATING FOR LUMINAIRE
FVH
BVH
FH
BH
FVH
BVH
FH
BH
G0
10
10
660
110
FOR ASYMMETRICAL LUMINAIRE TYPES (I, II, III, IV)
G1
G2
G3
G4
G5
100
225
500
750
>750
100
225
500
750
>750
1800
5000
7500
12000
>12000
500
1000
2500
5000
>5000
FOR QUADRILATERAL SYMMETRICAL LUMINAIRE TYPES (V, VSQUARE)
G0
G1
G2
G3
G4
G5
10
100
225
500
750
>750
10
100
225
500
750
>750
660
1800
5000
7500
12000
>12000
660
1800
5000
7500
12000
>12000
Report No. 100445508CRT-006
page 4 of 8
Date: October 3, 2011
RESULTS OF TESTS
Spectral Distribution over Visible Wavelengths
nm
mW/nm
nm
350
355
360
365
370
375
380
385
390
395
400
405
410
415
420
425
430
435
440
445
450
455
0.819
0.748
0.919
1.004
0.853
0.750
0.787
0.870
0.788
0.837
0.985
1.321
2.133
4.208
8.607
16.814
29.424
47.198
70.756
104.378
131.347
122.930
460
465
470
475
480
485
490
495
500
505
510
515
520
525
530
535
540
545
550
555
560
565
mW/nm
nm
SL4N4HLGH
93.269
570
70.510
575
56.370
580
45.106
585
37.089
590
32.753
595
31.075
600
32.292
605
37.165
610
44.636
615
54.167
620
63.488
625
73.065
630
81.041
635
88.419
640
93.417
645
97.543
650
100.901
655
103.115
660
104.722
665
106.093
670
106.402
675
mW/nm
nm
mW/nm
105.819
105.589
104.406
103.370
101.653
99.631
97.295
93.958
90.430
86.671
82.091
77.314
72.597
67.578
62.929
58.327
53.731
49.191
44.862
40.558
36.648
33.117
680
685
690
695
700
705
710
715
720
725
730
735
740
745
750
755
760
765
770
775
780
29.445
26.273
23.540
20.905
18.536
16.316
14.436
12.736
11.243
9.892
8.760
7.678
6.729
5.966
5.211
4.587
4.088
0.000
3.130
2.737
2.452
Dialight
Sample No. D234589-1
Model No. SL4N4HLGH
Spectral Data Over Visible Wavelengths
140.000
(mW/nm)
120.000
100.000
80.000
60.000
40.000
20.000
0.000
350
400
450
500
550
600
650
700
750
800
Nanometers
Report No. 100445508CRT-006
page 5 of 8
Date: October 3, 2011
RESULTS OF TESTS (cont’d)
Photometric Measurements at 25°C – Integrating Sphe re Method
Intertek
Sample
No.
Correlated
Color
Temperature
(K)
CRI
-Ra
CRI
-R9
D234589-1
4580
77.6
1.1
Duv
0.002
CIE 31’
Current Chromaticity
ATHD
Coordinate
(%)
(x)
SL4N4HLGH
14.90
0.359
CIE 31’
Chromaticity
Coordinate
(y)
CIE 76’
Chromaticity
Coordinate
(u’)
CIE 76’
Chromaticity
Coordinate
(v’)
0.367
0.215
0.494
Photometric and Electrical Measurements – Distribution Method
Intertek
Sample No.
Base
Orientation
D234589-1
LINEAR
Input Voltage Input Current Input Power Input Power
(Vac)
(mA)
(Watts)
Factor
Absolute
Luminous
Flux
(Lumens)
Lumen
Efficacy
(Lumens Per
Watt)
SL4N4HLGH
457.9
120.5
8092
67.15
277.0
0.950
Intensity (Candlepower) Summary at 25°C - Candelas
Angle
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
1304
1512
1492
2254
2866
2897
2885
2626
2568
2692
2510
2468
2732
2081
1211
334
27
7
0
0
0
22.5
45
SL4N4HLGH
1304 1304
1530 1499
1549 1513
2025 1799
2666 2074
2842 2401
2607 2688
2597 2496
2564 2473
2773 2398
2811 2316
2735 2802
2863 2932
2088 2741
1256 2766
1092 2094
758
609
269
195
38
88
0
8
0
1
Report No. 100445508CRT-006
67.5
90
1304
1426
1464
1594
1700
1859
1957
2095
2206
2162
2009
2491
2943
3052
2823
2747
2136
200
24
6
2
1304
1318
1228
1127
1141
1511
1787
1760
1931
1848
1770
1825
2135
2191
1982
1786
1569
25
2
2
1
page 6 of 8
Date: October 3, 2011
RESULTS OF TESTS (cont’d)
Illumination Plots
Model No.: SL4N4HLGH
Mounting Height: 25 ft.
Illuminance - Cone of Light
Isoillumination Plot
Zonal Lumen Summary and Percentages at 25°C
Zone
0-30
0-40
0-60
60-90
0-90
90-180
0-180
Lumens
SL4N4HLGH
1209
2227
5003
3084
8087
5.5
8092
% Luminaire
Lumens
SL4N4HLGH
117.2
367.0
725.0
1018
1262
1514
1619
1204
260.2
% Luminaire
14.9
27.5
61.8
38.1
99.9
0.1
100.0
Zonal Lumens and Percentages at 25°C
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
Report No. 100445508CRT-006
page 7 of 8
1.4
4.5
9.0
12.6
15.6
18.7
20.0
14.9
3.2
Date: October 3, 2011
RESULTS OF TESTS (cont’d)
BUG Rating (Backlight, Uplight, Glare)
Zone
Total
Lumens
Frontlight
Category
0-30
30-60
60-80
80-90
90-100
100-180
1209
3793
2823
260
5
0
FL
FM
FH
FVH
Frontlight Backlight
Lumens Category
SL4N4HLGH
871
BL
2812
BM
2107
BH
181
BVH
Backlight
Lumens
Uplight
Category
Uplight
Lumens
338
981
716
79
----UL
UH
----5
0
Backlight Rating: B 2
Uplight Rating: U 1
Glare Rating: G 2
Picture (not to scale)
CONCLUSION
The results tabulated in this report are representative of the actual test samples submitted for this report only.
The data is provided to the client for further evaluation. Compliance to the referenced specification
requirements was not determined in this report.
In Charge Of Tests:
Report Reviewed By:
Joseph Schledorn
Engineer
Lighting Division
Jeffery Davis
Senior Associate Engineer
Lighting Division
Attachment: None
Report No. 100445508CRT-006
page 8 of 8
Date: October 3, 2011