Vigilant® LED High Bay Fixture with Controls

Patent Pending
Vigilant® LED High Bay with DALI or Wireless Controls
for Indoor and Outdoor Industrial Applications
Take control of your lighting
The High Bay lighting control system combines Dialight’s industry leading LED
High Bay with a powerful yet simple to use High Bay Gateway.
On / Off Control
• Take advantage of the instant on/off capabilities of LED lighting with the
touch of a button
Dimming
Maximize your ROI by taking advantage of the easy to use dimming feature
• Adjust light output from 100% down to 10% in 10% increments
• Dimming events are faded for smooth transitions between light levels
Grouping
Fixtures can be combined into groups to allow quick control over different
areas in a facility
• Fixtures can be set to blink for easy identification
Scheduling
Dialight's comprehensive, energy efficient and fully customizable lighting
schedule allows you to get the most out of your lighting network, 24/7
• Easily control when fixtures turn on, off or dim
• Lighting events are set by daily profiles and can be scheduled in
one-minute intervals
Integrated Sensors
• The High Bay Gateway features an occupancy sensor that will override a
scheduled off state or dim state when someone triggers the sensor
• An ambient light sensor allows for daylight harvesting in areas where
skylights or windows contribute to illumination
Wireless IEEE 802.15.4 Standard
Frequency of operation
• 2.4GHz global digital communication standard
High Bay Gateway
• One High Bay Gateway can control up to 100 lights
• Touch screen interface for easy commissioning and control
• Can be controlled from any Tablet or PC on the network
Mesh network topology
• Extends network range by relaying network communications from light to light
• Increases reliability by self-healing wireless network routing
Communications Range
• Up to 100’ (30.48m) from the High Bay Gateway to the first fixture and
100’ (30.48m) from fixture to fixture
Secure encrypted communications
• 128-bit AES encryption
• Secure authentication and device joining
Wired DALI system
• Create a fixture network of up to 64 Lights
• DALI fixtures can be mounted up to 984’ (300m) apart and away
from the High Bay Gateway
• DALI communication wires can be wired without regard for polarity
Wi - Fi Connections
Directly connect to the High Bay Gateway from your Wi-Fi enabled device
Direct Wi-Fi connectivity to the High Bay Gateway gives users the freedom to fully
manage the lighting system while roaming about the lighting area
www.dialight.com
Mechanical Information
Fixture weight:
18 lbs (8.16kg)
Shipping weight:
24 lbs (10.8kg)
Mounting:
(1) 3/4” NPT - top
(2) 5/16”-18 x .75” UNC - side
Cabling:
10' (3.05m) STOOW Power Cord
Electrical specifications
Vigilant® LED High Bay
Operating Voltage:
110 – 277V AC:
100 – 277V AC:
Total System
Power Consumption:
See table
Operating Temp:
-40°F to +149°F (-40°C to +65°C)
Harmonics:
IEC 61000-3-2
Noise Requirements/
EMC:
Dimensions are in Inches [mm]
26,500lm models
18,000, 14,000 & 11,000lm models
FCC Title 47, Subpart B, Section 15, class A
device. RF Immunity; 10V/m, 80MHz-1GHz
Transient Protection:
Protection devices capable of handling up to
6kA. Tested for 6kV/2 ohm combination wave, as
per IEEE C62.41, line-line and line-ground
Power Factor:
> 0.9
THD:
15%
Certifications & Ratings
Construction
• UL 1598/A
• CSA 22 #250
• NEMA 4X
• IP 66
• Dark Sky Compliant
Housing:
Copper free powder coated aluminum
Finish:
Polyester powder coated gray RAL 7040
Lens:
Tempered glass
Photometric Information
CRI:
75
CCT:
5,000K (cool white)
4,000K (neutral white)
All values typical unless otherwise stated
Lumen values are typical (tolerance +/- 10%)
Mechanical Information
Fixture Weight:
7lbs (3.18kg)
Mounting:
Four (4) .25in (6.35mm) Flat surface wall
mounting screw holes
Cabling:
RJ45 10/100MB Ethernet port
Electrical specifications
Dimensions are in Inches [mm]
Sensors
Operating Voltage:
120 – 277V AC
Network Adapter:
RJ45 10/100MB Ethernet port
Operating Temp:
-40°C to +65°C
Construction
• Pyroelectric Infrared PIR Motion Sensor Detector
• Detecting distance up to 22ft (7m)
• Ambient light sensor
• Tuned for human eye spectral sensitivity
Housing:
Physical Dimensions
All values typical unless otherwise stated
Lumen values are typical (tolerance +/- 10%)
• 9.5in (241.3mm) Width
• 9.5in (241.3mm) Height
• 2in (50.8mm) Depth
Screen
• 7in (177.8mm) Diagonal
• 6in (152.4mm) Wide
• 3.5in (88.9mm) High
• User Input: Resistive Touch screen
• Resolution – 800 x 480 pixels
www.dialight.com
Aluminum, plastic available (consult factory)
Vigilant® LED High Bay - Ordering Information
Part number1,2
Lumens
HEGMC4PJ-SNG
HEGRC4PJ-SNG
HEGMC4KJ-SNG
HEGRC4KJ-SNG
HEGMC4GJ-SNG
HEGRC4GJ-SNG
26,500
26,500
18,000
18,000
14,000
14,000
HEGMC4PA-SNG
HEGRC4PA-SNG
HEGMC4KA-SNG
HEGRC4KA-SNG
HEGMC4GA-SNG
HEGRC4GA-SNG
26,500
26,500
18,000
18,000
14,000
14,000
WLC-004-MBAL
Lumens
Wet
Voltage
CCT1
Lens
per Watt
Location
Vigilant LED High Bay - Jennet 2.4GHz
217
122
110 - 277V AC 5,000 (Cool White)
IP66
Tempered glass
217
122
110 - 277V AC 5,000 (Cool White)
IP66
Tempered glass
149
121
100 – 277V AC 5,000 (Cool White)
IP66
Tempered glass
149
121
100 – 277V AC 5,000 (Cool White)
IP66
Tempered glass
117
120
100 – 277V AC 5,000 (Cool White)
IP66
Tempered glass
117
120
100 – 277V AC 5,000 (Cool White)
IP66
Tempered glass
Vigilant LED High Bay - DALI Protocol
217
122
110 - 277V AC 5,000 (Cool White)
IP66
Tempered glass
217
122
110 - 277V AC 5,000 (Cool White)
IP66
Tempered glass
149
121
100 – 277V AC 5,000 (Cool White)
IP66
Tempered glass
149
121
100 – 277V AC 5,000 (Cool White)
IP66
Tempered glass
117
120
100 – 277V AC 5,000 (Cool White)
IP66
Tempered glass
117
120
100 – 277V AC 5,000 (Cool White)
IP66
Tempered glass
High Bay Gateway - DALI & Jennet
10W typical, 20W max
120 – 277V AC
Wattage
Optics
Circular Wide
•
•
•
•
•
•
•
•
•
•
•
•
Part numbers in table above are in cool white (5,000K CCT). For models needing neutral white (4,000K CCT), replace the 5th character with a N. Example: HEGMC4PN-SNG
becomes HEGMN4PN-SNG. Deduct 8% from lumen values when specifying neutral.
For models needing Safety Bracket replace the 10th character with a S. Example: HEGMC4PN-SNG becomes HEGMC4PN-SSG
1
2
Part Number
Description
No Part Number
Pendant Mount
(Conduit supplied by installer)
HBXW2
Swivel Bracket and Cable Gland
HBXW3
Swivel Bracket
Swivel Bracket
Bracket to Fixture Hardware
HBXDUALBRCKT
Dual bracket
Junction Box
HBXCU
Ceiling Mount
Swivel Hanger Cover
3" Conduit Nipple
HBXCG
Cable Gland
Cable Gland (1/2”)
Reducer (3/4” to 1/2”)
HBXL
Loop
Hanger Loop (GE LOOPM353)
HBXH
Hook
Hanger Hook (GE HOOKM353)
HBXLENGC
HBXLENAC
HBXLENAD
HBXLENPC
HBXLENPD
Tempered Glass
Acrylic Lens, Clear
Acrylic Lens, Diffused
Polycarbonate Lens, Clear
Polycarbonate Lens, Diffused
22” Acrylic Reflector
(Must be ordered with High Bay,
not a retrofit option)
HBXREF22
HBXDC
Dust Cover
Kit Includes
Conduit supplied by installer
Swivel Bracket
Bracket to fixture hardware
Cable Gland (1/2”), Reducer (3/4” to 1/2”)
Lens, replacement clips, screws, gasket
Lens, replacement screws, gasket
Lens, replacement screws, gasket
Reflector, brackets, screws
Dust cover, clamp, spacer
HBXW3-SSL-316
Swivel Bracket
Stainless Steel Swivel Bracket
Stainless Steel Swivel Bracket and
Stainless Steel Mounting Hardware
HBXW3-SSL-304
Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document will always be available at:
www.dialight.com/Assets/Brochures_And_Catalogs/Illumination/MDEXVHBCONX001.pdf Warranty Statement: EXCEPT FOR THE WARRANTY EXPRESSLY PROVIDED FOR [HEREIN/ABOVE/BELOW], DIALIGHT DISCLAIMS
ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND NONINFRINGEMENT.
www.dialight.com
MDEXVHBCONX001_B