Product data sheet G3G250GN1701 - ebm

EC centrifugal fan
G3G250-GN17-01
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
[email protected]
www.ebmpapst.com
Nominal data
Type
G3G250-GN17-01
Motor
M3G084-FA
Phase
1~
Nominal voltage
VAC
230
Nominal voltage range
VAC
208 .. 240
Frequency
Hz
50/60
Type of data definition
ml
Speed
min-1
4800
Power input
W
1150
Current draw
A
5.7 @ 208 V
Min. ambient temperature
°C
-20
Max. ambient temperature
°C
60
Min. temp. of flow medium
°C
0
Max. temp. of flow medium
°C
60
ml = max. load · me = max. efficiency · rfa = running at free air · cs = customer specs · cu = customer unit
Subject to alterations
Item no.: 50133-5-9980 · Revision: 66688 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 1 of 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com
EC centrifugal fan
G3G250-GN17-01
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Technical features
Mass
13.2 kg
Size
250 mm
Surface of rotor
Coated in black
Material of protective cover
Polyflam RPP 374-ND CS1 (UL 97-V0)
Material of impeller
Aluminum sheet
Housing material
Die-cast aluminum
Number of blades
7
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"B"
Max. permissible ambient
motor temp. (transp./ storage)
+80 °C
Min. permissible ambient
motor temp. (transp./storage)
-40 °C
Mounting position
Any
Condensate discharge holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Technical features
- Tach output
- Over-temperature protected electronics / motor
- PFC, active
- Motor current limit
- Line undervoltage / phase failure detection
- PWM control input
- Control input 0-10 V
EMC interference immunity
Acc. to EN 61000-6-2 (industrial environment)
EMC interference emission
Acc. to EN 61000-6-4 (industrial environment)
EMC harmonics
Acc. to EN 61000-3-2/3
Leakage current
<= 3.5 mA
Electrical leads
With plug
Motor protection
Locked-rotor protection
Protection class
I
Approval
CCC; CSA C22.2 Nr.113; UL 507
Item no.: 50133-5-9980 · Revision: 66688 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 2 of 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com
G3G250-GN17-01
EC centrifugal fan
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Product drawing
1
3-pole strip to fit mating connector (not included in standard scope of delivery) tyco No. 350766-1, female connector tyco No.
926884-1
1.1
L
1.2
N
1.3
PE
2
5-pole strip to fit mating connector (not included in standard scope of delivery) Molex No. 39-01-4050, female connector Molex
No. 39-00-0059
2.1
+
2.2
Speed monitoring
2.3
0-10 VDC control input
2.4
PWM input
2.5
-
3
Pressure tap optionally available
Y
Detail Y
Z
View Z / plug assignment
Item no.: 50133-5-9980 · Revision: 66688 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 3 of 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com
G3G250-GN17-01
EC centrifugal fan
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Connection screen
No.
Pin
Signal
Function / assignment
ST1
1; 2; 3
L; N; PE
Power supply 230 VAC, 50 - 60 Hz, phase, neutral, protective earth
St2
1
UB
External voltage 16 - 45 VDC, residual ripple +/- 3.5%, SELV
ST2
2
DUE
Speed monitoring, 3 pulses per revolution, SELV
ST2
3
0 - 10 V
Control input 0 - 10 V, impedance 100k, SELV
ST2
4
PWM
Control input PWM, 1 - 6 kHz, SELV
ST2
5
GND
GND - Connection for control interface, SELV
Item no.: 50133-5-9980 · Revision: 66688 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 4 of 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com
EC centrifugal fan
G3G250-GN17-01
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Charts: Air flow 50 Hz
Druck psf [Pa]für Rho=1,2kg/m^3
3.500
0
200
qv[cfm]
600
400
800
1.000
14
3.400
13,5
3.300
13
3.200
12,5
3.100
3.000
12
4
2.900
11,5
2.800
11
2.700
2.600
10,5
2.500
10
2.400
9,5
2.300
9
2.200
8,5
3
2.000
8
sf [Pa]
p
1.900
7,5
1.800
7
1.700
1.600
6,5
1.500
6
1.400
5,5
1.300
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
5
1.200
1.100
4,5
2
1.000
4
900
3,5
800
3
700
600
2,5
500
2
400
1,5
300
1
Pa ]
spf [
200
100
0
p sf _E[IN H2O]
2.100
Measurement: LU-76445
0,5
1
0
200
400
600
800
1.000
qv[m^3/h]
1.200
1.400
1.600
1.800
0
2.000
Measured values
U
f
n
Pe
I
LpAin
qv
psf
V
Hz
min-1
W
A
dB(A)
m3/h
Pa
1
230
50
4890
1022
4.47
91
1655
0
2
230
50
4800
1150
5.00
89
1405
1000
3
230
50
4850
1117
4.87
81
1105
2000
4
230
50
5005
920
4.01
79
685
2900
Item no.: 50133-5-9980 · Revision: 66688 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 5 of 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com