G3G200GN1801 1593541

EC centrifugal fan
G3G200-GN18-01
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
ebm-papst Landshut GmbH
Hofmark-Aich-Str. 25 · D-84030 Landshut
Phone +49 871 707-0
Fax +49 871 707-465
[email protected]
www.ebmpapst.com
Nominal data
Type
G3G200-GN18-01
Motor
M3G084-DF
Phase
1~
Nominal voltage
VAC
230
Nominal voltage range
VAC
208 .. 240
Frequency
Hz
50/60
Type of data definition
ml
Speed
min-1
5700
Power input
W
750
Current draw
A
3.6 @ 208 V
Min. ambient temperature
°C
-20
Max. ambient temperature
°C
60
Min. temp. of flow medium
°C
0
Max. temp. of flow medium
°C
60
ml = max. load · me = max. efficiency · rfa = running at free air · cs = customer specs · cu = customer unit
Subject to alterations
Item no.: 50131-5-9980 · Revision: 72552 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 1 of 5
ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com
EC centrifugal fan
G3G200-GN18-01
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Technical features
Mass
9.2 kg
Size
200 mm
Surface of rotor
Coated in black
Material of protective cover
Polyflam RPP 374-ND CS1 (UL 97-V0)
Material of impeller
Aluminium sheet
Housing material
Die-cast aluminium
Number of blades
7
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"B"
Max. permissible ambient
motor temp. (transp./ storage)
+80 °C
Min. permissible ambient
motor temp. (transp./storage)
-40 °C
Mounting position
Any
Condensate discharge holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Technical features
- Tach output
- Over-temperature-protected electronics / motor
- PFC, active
- Motor current limit
- Line undervoltage / phase failure detection
- PWM control input
- Control input 0-10 V
EMC interference immunity
Acc. to EN 61000-6-2 (industrial environment)
EMC interference emission
Acc. to EN 61000-6-4 (industrial environment)
EMC harmonics
Acc. to EN 61000-3-2/3
Leakage current
<= 3.5 mA
Electrical leads
With plug
Motor protection
Locked-rotor protection
Protection class
I
Approval
CCC; CSA C22.2 Nr.113; UL 507
Item no.: 50131-5-9980 · Revision: 72552 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 2 of 5
ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com
G3G200-GN18-01
EC centrifugal fan
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Product drawing
Y
Detail Y
Z
View Z / plug assignment
1
3-pole strip to fit mating connector (not included in standard scope of delivery) Tyco No. 350766-1, female connector Tyco No.
926884-1
1.1
L
1.2
N
1.3
PE
2
5-pole strip to fit mating connector (not included in standard scope of delivery) Molex No. 39-01-4050, female connector Molex
No. 39-00-0059
2.1
+
2.2
Speed monitoring
2.3
0-10 VDC
2.4
PWM input
2.5
-
3
Pressure tap optionally available
Item no.: 50131-5-9980 · Revision: 72552 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 3 of 5
ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com
G3G200-GN18-01
EC centrifugal fan
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Connection screen
No.
Pin
Signal
Function / assignment
ST1
1; 2; 3
L; N; PE
Power supply 230 VAC, 50 - 60 Hz, phase, neutral, protective earth
ST2
1
UB
External voltage 16 - 45 VDC, residual ripple +/- 3.5%, SELV
ST2
2
DUE
Speed monitoring, 3 pulses per revolution, SELV
ST2
3
0 - 10 V
Control input 0 - 10 V, impedance 100k, SELV
ST2
4
PWM
Control input PWM, 1 - 6 kHz, SELV
ST2
5
GND
GND - Connection for control interface, SELV
Item no.: 50131-5-9980 · Revision: 72552 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 4 of 5
ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com
EC centrifugal fan
G3G200-GN18-01
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Charts: Air flow 50 Hz
Druck psf [Pa]für Rho=1,2kg/m^3
2.900
0
100
200
qv[cfm]
400
300
500
600
700
11,5
2.800
11
2.700
10,5
2.600
4
2.500
9,5
2.300
9
2.200
8,5
2.100
3
2.000
8
1.900
7,5
1.800
6,5
sf [Pa]
p
1.600
1.500
6
7
1.400
5,5
1.300
5
1.200
1.100
2
900
4
11
3,5
800
3
6
16
600
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
4,5
12
1.000
700
p sf _E[IN H2O]
7
8
1.700
2,5
15
500
2
10
400
1,5
300
14
1
9
]
0
100
200
300
400
500
600
700
qv[m^3/h]
5
800
0,5
1
]
13
Pa
spf [
]
[Pa
spf
a
[P
spf
100
Pa]
spf [
200
0
Measurement: LU-76333
10
2.400
900
1.000
1.100
1.200
0
1.300
Measured values
U
f
n
Pe
I
LpAin
qv
psf
V
Hz
min-1
W
A
dB(A)
m3/h
Pa
1
230
50
5700
681
2.97
86
1020
0
2
230
50
5700
750
3.30
84
840
1000
3
230
50
5700
682
2.98
81
600
2000
4
230
50
5700
557
2.44
78
400
2475
5
230
50
4700
381
1.66
81
840
0
6
230
50
4700
413
1.80
79
690
677
7
230
50
4700
381
1.67
76
495
1352
8
230
50
4700
311
1.36
74
330
1678
9
230
50
3700
186
0.81
75
660
0
10
230
50
3700
201
0.88
73
545
420
11
230
50
3700
186
0.81
71
390
838
12
230
50
3700
152
0.67
69
260
1040
13
230
50
2800
80
0.35
69
500
0
14
230
50
2800
87
0.38
66
410
240
15
230
50
2800
81
0.35
64
295
480
16
230
50
2800
66
0.29
63
195
595
Item no.: 50131-5-9980 · Revision: 72552 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 5 of 5
ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com