EC centrifugal fan G3G200-GN18-01 backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating ebm-papst Landshut GmbH Hofmark-Aich-Str. 25 · D-84030 Landshut Phone +49 871 707-0 Fax +49 871 707-465 [email protected] www.ebmpapst.com Nominal data Type G3G200-GN18-01 Motor M3G084-DF Phase 1~ Nominal voltage VAC 230 Nominal voltage range VAC 208 .. 240 Frequency Hz 50/60 Type of data definition ml Speed min-1 5700 Power input W 750 Current draw A 3.6 @ 208 V Min. ambient temperature °C -20 Max. ambient temperature °C 60 Min. temp. of flow medium °C 0 Max. temp. of flow medium °C 60 ml = max. load · me = max. efficiency · rfa = running at free air · cs = customer specs · cu = customer unit Subject to alterations Item no.: 50131-5-9980 · Revision: 72552 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 1 of 5 ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com EC centrifugal fan G3G200-GN18-01 backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating Technical features Mass 9.2 kg Size 200 mm Surface of rotor Coated in black Material of protective cover Polyflam RPP 374-ND CS1 (UL 97-V0) Material of impeller Aluminium sheet Housing material Die-cast aluminium Number of blades 7 Direction of rotation Clockwise, seen on rotor Type of protection IP 20 Insulation class "B" Max. permissible ambient motor temp. (transp./ storage) +80 °C Min. permissible ambient motor temp. (transp./storage) -40 °C Mounting position Any Condensate discharge holes Rotor-side Operation mode S1 Motor bearing Ball bearing Technical features - Tach output - Over-temperature-protected electronics / motor - PFC, active - Motor current limit - Line undervoltage / phase failure detection - PWM control input - Control input 0-10 V EMC interference immunity Acc. to EN 61000-6-2 (industrial environment) EMC interference emission Acc. to EN 61000-6-4 (industrial environment) EMC harmonics Acc. to EN 61000-3-2/3 Leakage current <= 3.5 mA Electrical leads With plug Motor protection Locked-rotor protection Protection class I Approval CCC; CSA C22.2 Nr.113; UL 507 Item no.: 50131-5-9980 · Revision: 72552 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 2 of 5 ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com G3G200-GN18-01 EC centrifugal fan backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating Product drawing Y Detail Y Z View Z / plug assignment 1 3-pole strip to fit mating connector (not included in standard scope of delivery) Tyco No. 350766-1, female connector Tyco No. 926884-1 1.1 L 1.2 N 1.3 PE 2 5-pole strip to fit mating connector (not included in standard scope of delivery) Molex No. 39-01-4050, female connector Molex No. 39-00-0059 2.1 + 2.2 Speed monitoring 2.3 0-10 VDC 2.4 PWM input 2.5 - 3 Pressure tap optionally available Item no.: 50131-5-9980 · Revision: 72552 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 3 of 5 ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com G3G200-GN18-01 EC centrifugal fan backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating Connection screen No. Pin Signal Function / assignment ST1 1; 2; 3 L; N; PE Power supply 230 VAC, 50 - 60 Hz, phase, neutral, protective earth ST2 1 UB External voltage 16 - 45 VDC, residual ripple +/- 3.5%, SELV ST2 2 DUE Speed monitoring, 3 pulses per revolution, SELV ST2 3 0 - 10 V Control input 0 - 10 V, impedance 100k, SELV ST2 4 PWM Control input PWM, 1 - 6 kHz, SELV ST2 5 GND GND - Connection for control interface, SELV Item no.: 50131-5-9980 · Revision: 72552 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 4 of 5 ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com EC centrifugal fan G3G200-GN18-01 backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating Charts: Air flow 50 Hz Druck psf [Pa]für Rho=1,2kg/m^3 2.900 0 100 200 qv[cfm] 400 300 500 600 700 11,5 2.800 11 2.700 10,5 2.600 4 2.500 9,5 2.300 9 2.200 8,5 2.100 3 2.000 8 1.900 7,5 1.800 6,5 sf [Pa] p 1.600 1.500 6 7 1.400 5,5 1.300 5 1.200 1.100 2 900 4 11 3,5 800 3 6 16 600 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 4,5 12 1.000 700 p sf _E[IN H2O] 7 8 1.700 2,5 15 500 2 10 400 1,5 300 14 1 9 ] 0 100 200 300 400 500 600 700 qv[m^3/h] 5 800 0,5 1 ] 13 Pa spf [ ] [Pa spf a [P spf 100 Pa] spf [ 200 0 Measurement: LU-76333 10 2.400 900 1.000 1.100 1.200 0 1.300 Measured values U f n Pe I LpAin qv psf V Hz min-1 W A dB(A) m3/h Pa 1 230 50 5700 681 2.97 86 1020 0 2 230 50 5700 750 3.30 84 840 1000 3 230 50 5700 682 2.98 81 600 2000 4 230 50 5700 557 2.44 78 400 2475 5 230 50 4700 381 1.66 81 840 0 6 230 50 4700 413 1.80 79 690 677 7 230 50 4700 381 1.67 76 495 1352 8 230 50 4700 311 1.36 74 330 1678 9 230 50 3700 186 0.81 75 660 0 10 230 50 3700 201 0.88 73 545 420 11 230 50 3700 186 0.81 71 390 838 12 230 50 3700 152 0.67 69 260 1040 13 230 50 2800 80 0.35 69 500 0 14 230 50 2800 87 0.38 66 410 240 15 230 50 2800 81 0.35 64 295 480 16 230 50 2800 66 0.29 63 195 595 Item no.: 50131-5-9980 · Revision: 72552 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 5 of 5 ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0 · Fax +49 871 707-465 · [email protected] · www.ebmpapst.com