R
Harnessing Solar Power for greener earth and better tomorrow
Solar Grid Connect Inverter
INTRODUCTION
DB Power Electronics has pioneered the Photovoltaic
Inverter Systems since 1992 with Bi-directional grid
connect technology and custom built product solutions for
critical applications.
Bhaskar GCI 030
30 to 250 kW
Three Phase output
Ranging from a smallest power pack to large solar farms,
the generated photovoltaic power fed to the grid to
manage the grid parity situations. From the remotest
location to the largest building integrated photovoltaic
systems (BIPVs), DB power holds the market presence with
one of the largest installation base across the country.
These installations are catering needs of the customers for
more than a decade. In-house, State-of-the-art design
capability and indigenous technology are the core
competence of DB Power in the field of solar photo voltaic .
FEATURES
DSP based modular design
State-of-the-Art Technology
High Efficiency & High Reliability
User friendly display and Monitoring
Robust Design - 20 years design life
Compliance to International Standards
Core Competence in Power Electronics
HIGHLIGHTS
DSP based modular design
Fully digital control,
to have more scalability and easy upgradability.
GCIMON
II
and SNMP Agent
Robust Design
20 years design life. Tropicalised design.
GCIMON II
Simple & Easy Installation
Advanced
communication and
Remote monitoring
solution.
Enclosure with Integrated PV Array combiner unit,
AC/DC switchgear for protection & isolation,
built in output isolation transformer.
Display & Monitoring System
User friendly OLED display.
Sophisticated local & remote monitoring system (GCIMON).
Modem and Ethernet connectivity
for remote monitoring.
Compliance to International standards
Safety and EMC standards complying to IEC 62040, UL 1741,
EN 61000-6-2, EN 61000-6-4, IEEE 519, IEEE 929 - 2000, IEEE 1547 - 2003.
Safety to the user is provided by shrouding high potential points inside the system.
Grid islanding protection.
Bhaskar GCI
SPECIFICATIONS
Solar Grid Connect Inverter
30 to 250 kW Three Phase output
Bhaskar GCI 030
MODEL
Rating
30 kW
125 kW
250 kW
400 V to 700 VDC
Inverter Input range
MPPT
Controller Type
415 V AC (L-L), 3 Phase & N
Nominal Output Voltage
+ 10 % to - 20 %
Grid Tracking range
50 Hz
Frequency
± 3 Hz
Grid Tracking range
Power Capacity
30 kW
125 kW
250 kW
Output Current Limit
43.3 A
180 A
360 A
> 0.98
Line Power Factor
Sine wave
Waveform
<5%
Current THD
IGBT based current controlled PWM inverter
Inverter
Continuous
Duty
Peak efficiency
Renewable Input Capacity
Acoustic Noise Level
Up to 92 %
Up to 93 %
Up to 95 %
30 kW
125 kW
250 kW
< 65 dBA @ 1 meter
< 70 dBA @ 1 meter
< 70 dBA @ 1 meter
Service Temperature
0 to 40 0 C
Storage Temperature
- 10 to 55 0 C
Upto 95 % (Non condensing)
Relative Humidity
< 1000 meter, above sea level (without derating)
Altitude
IP 30 (IP 54 optional)
Enclosure Protection
Cooling
Forced Air
Colour
Havells Gray (RAL 7035)
Bottom
Cable Entry
Dimensions (in mm)
W x D x H + Plinth
Weight in kg (Approx.)
800 x 700 x 1400 + 150
1400 x 900 x 1800 + 150
2000 x 900 x 1800 +150
375
800
1500
Bhaskar GCI
LCD DISPLAY, PROTECTIONS & PFCs
LCD Display
ID
Sys. Sr. No.
Client
Software Versions
Array Voltage
Array Current
Array power kW
Array Load (%)
Array kWH - Daily
Solar radition
Array cell temp
Inverter Heat Sink Temp.
DC Voltage
Output Load (%)
Grid Frequency
Grid Current
Grid Voltage
Grid Power kW
Grid Power kVA
Grid kW Hour daily
Grid kW Hour total
Display Faults
Array fail
AC / DC Earth fault
No sync
Inverter Over Current
Inverter Over Temp.
DC Over Voltage
Fast DC Over Voltage
DC under voltage
Local emergency stop
Wrong phase
Mains abnormal
Indications
OK (GCI running)
Alarm
Warning
Controls
ON
RESET
SOFT KEY - 1
OFF
UP
SOFT KEY - 2
Ack
DOWN
Emergency Stop
Protections
Array Surge Voltage
Grid Surge Voltage
DC Over Voltage
Output Under Voltage
Output Over Voltage
Output Overload
Output Short Circuit
Inverter Over temperature
Grid Islanding
*Alarms are provided for all important protections
PFC
GCI ON
Fault
Optional
Features
Remote monitoring through GCIMON
Modem Connectivity
Overload
MODBUS (RS232)
Ethernet (SNMP, HTTP, GCIMON)
SINGLE LINE DIAGRAM
PV
Modules
Combiner
(optional)
Grid Connect Inverter
IP 30
(NEMA 3R optional)
Bi-directional
Inverter
To Grid
Isolation
Transformer
Contactor
Circuit
Breaker
Control
& Monitoring
GCIMON
(RS232 Link)
GCIMON
MODBUS
SNMP
MODEM
(Ethernet) (BMS Software)(MIB Browser) Connectivity
Bhaskar GCI is Three phase output, Grid connect inverter system. Solar Photovoltaic Panels are used to convert Solar energy into
electrical energy. These Solar PV panels produce DC power, which become input for the inverter. The inverter converts it into
conventional AC power. This AC power feed to the supply grid.
APPLICATION REFERENCE
More than 1500 PCUs (ranging from 1 to 6 kW and
n
10 to 30 kW) are working in the field, for over a decade
In 1994, 15 kW Grid Interactive PCU, supplied to TEDA,
n
for feeding power to the Wind grid.
Lonavala :100 kW
Leh : 36 kW
Ladakh : 36 kW
Thailand : 400 kW
CREDA : 2kW, 200 Nos
Lonavala :100 kW
Sagar Islands : 40 kW
120/37, Ramtekdi Industrial Area, Hadapsar, Pune 411 013. (INDIA)
ISO 9001 : 2000
Western Region
Southern Region
Eastern Region
Northern Region
• Mumbai • Nagpur • Aurangabad • Goa • Kolhapur • Nasik • Indore • Bhopal • Vadodara • Ahmedabad • Surat • Rajkot
• Hyderabad • Vizag • Vijayawada • Chennai • Madurai • Coimbatore • Bangalore • Mangalore • Cochin
• Kolkata • Patna• Bhubaneshwar • Jamshedpur • Raipur • Guwahati • Siliguri
• New Delhi • Chandigarh • Ludhiana • Gurgaon • Noida • Lucknow • Jaipur
DB Overseas Partners • Italy • France • UK • UAE • Sri Lanka • Nepal • Bangladesh • Saudi Arabia
R&D being continuous process, the specifications are subject to change without prior notice.
www.dbups.com
MK-IND-CAT-GCI-RO-1009 [email protected]
SÜD
T +91 20 26808050 - 60 F 26808061 E [email protected]