Catalogue 08 - Emerson Network Power

R
Energizing the plasma technology
Specially designed power supply for ;
PACVD / PECVD (Plasma Assisted / Enhanced Chemical Vapor Deposition)
Electro-deposition
Nano-oxide reduction by hydrogen glow discharge
High precision plasma metal removal from surfaces using reactive gases
Hydrogen Production
Anodizing
Pulse Power Supply
10 to 60 kVA
FEATURES
Option of voltage or current mode, as per the process requirement
Smooth sputtering mode, +200 V to +1100 V pulse
with variable duty and frequency
Pulse frequency setting and variable voltage option
Plasma current setting as per available working surface area
Core Competence in Power Electronics
R
Pulse Power Supply
SPECIFICATIONS
10 kVA
Rating
20 kVA
40 kVA
60 kVA
415 V AC (+10% to - 10%), Three Phase & N
Input Voltage
50 Hz (± 10%)
Input Frequency
Rectifier Type
Full Wave
Output Power
10 kW, 20 kW, 40 kW, 60 kW
0 - 1200 V (Adjustable through 10 turn POT with dial)
Output Voltage
1 kHz to 6 kHz Variable
Output Frequency
Duty Cycle
10 - 95%
Waveform
Duty cycle controlled chopped DC output
Standalone
Configuration
> 90% (At full load & nominal input voltage)
Efficiency
< 64 dBA @ 1 meter
Acoustic Noise Level
Ambient Temp
0 to 400 C
Storage Temp
-10 to 700 C
Up to 95% (Non Condensing)
Relative Humidity
< 1000 meter. Above Sea Level (Without derating)
Altitude
IP - 41
Enclosure Protection Grade
Cooling
Forced Air
Colour
Hawells Gray (RAL 7035)
Bottom
Cable Entry
800 X 800 X 1600
Dimension (W X D X H) in mm
275 kg
Weight
300 kg
350 kg
400 kg
IEC 62040 - 3
Testing Standards
100
DISPLAY & INDICATIONS
Metering
DC Voltage
w
Output Current
w
Output Frequency
w
LED Indications
Control Supply OK
w
Rectifier Over Voltage w
Mains ON
w
R
Air Outlet
Output OT
w
Input Single Phasing/
w
Phase reversal
Input Contactor
w
High Speed
w
Over Current
Over Temperature
w
Output Overload
w
Output Short Circuit
w
H
Protections
Rectifier Over Voltage
w
Arc Suppression
w
Alarms are provided for all important protections
¬
Potentiometer
Output Voltage
w
Switch
Auto / Manual for Output Voltage
w
Output Frequency
w
Duty Cycle
w
150
Air Inlet
Controls
W
Front View
D
Side View
120/37, Ramtekdi Industrial Area, Hadapsar, Pune 411 013. (INDIA)
Western Region
Southern Region
Eastern Region
Northern Region
• Mumbai • Nagpur • Aurangabad • Goa • Kolhapur • Nasik • Indore • Bhopal • Vadodara • Ahmedabad • Surat • Rajkot • Silvassa
• Hyderabad • Vizag • Vijayawada • Chennai • Madurai • Coimbatore • Bangalore • Mangalore • Cochin
• Kolkata • Patna• Bhubaneshwar • Jamshedpur • Raipur • Guwahati • Siliguri
• New Delhi • Chandigarh • Ludhiana • Gurgaon • Noida • Lucknow • Jaipur
DB Overseas Partners • Italy • France • UK • UAE • Sri Lanka • Nepal • Bangladesh • Saudi Arabia • Oman
R&D being continuous process, the specifications are subject to change without prior notice.
www.dbups.com
PPS/1.0/Jan 09/500
Tel +91 20 26808050 - 60 Fax 26808061 email [email protected]