Integrated Cabinet Solutions For Business-Critical Continuity™ Aisle Containment Systems Flexible Containment Systems To Increase Efficiency Offerings Increase Energy Efficiency With Emerson Network Power Aisle Containment Systems Reduce energy consumption while supporting higher density IT and networking equipment — without compromising your Raised floor data center with perimeter precision cooling (Liebert DS or Liebert CW ) requirement for availability. Aisle Containment Systems from Emerson Network Power are designed to optimize the efficiency, design and operation of your data center infrastructure. A comprehensive selection makes it easy to support both standard and non-uniform hot/cold aisle applications. Ideally Suited For: H ot aisle/cold aisle applications Raised floor data centers with perimeter cooling N on-raised floor data centers using row-based precision cooling systems such as Liebert® CRV™ or Liebert XD™ Retrofit to existing racks, or DCF™ & DCM™ racks E merson Network Power SmartAisle™ Solutions with Liebert precision cooling and Liebert iCOM® controls Configurations to fit any site needs: Slab floor data center with Liebert CRV row-based precision cooling and Modular System M odular roof and door system for DCF & DCM racks Vertical system for non-uniform rows and rack heights R etractable roof Variable standard components interchangeable to create custom solutions Aisle Containment Systems from Emerson Network Power may be installed at any location in the data center, with options to fit most rack configurations. Shown with Vertical System. 2 Typical Data Center (top view) Problem: In the thermographic view of a typical data center, the problem with the traditional approach in high density data centers is highlighted by the numerous hot spots and wide variation in inlet temperatures to the IT equipment. Hot Spot IT Racks Perimiter Cooling Units Hot Aisle Cold Aisle Liebert Aisle Containment in Data Center (top view) Solution: Liebert® Precision Cooling systems with Liebert iCOM® control are enhanced by Aisle Containment from Emerson Network Power, enabling dynamic optimization of the cooling environment, and lower energy usage. Typical Data Center (end of row view) IT Racks Cold Aisle Hot Aisle Aisle Containment Systems Are Designed to: Optimize Cooling System Efficiency 30+% efficiency increase Continuous dynamic adaptation to load Less fan power per kW cooling Eliminate Hot/Cold Air Mixing Without aisle containment, hot and cold air mix in both the hot and cold aisles, making the cooling system less effective and less energy efficient. Data Center with Aisle Containment System / Liebert iCOM controls (end of row view) Uniform and predictable temperature to all IT equipment Integrate the cooling unit air flow delivery with the IT equipment requirements Increase Space Efficiency 30+% increase in IT equipment density Up to 12kW/rack with perimeter cooling Up to 30kW/rack with localized cooling Increase Capacity Aisle Containment combined with Liebert precision cooling with iCOM controls enables uniform temperature effective cooling, and consistently hot return air for more effective precision cooling system performance. 25+% increase in available cooling capacity Extend capacity of existing precision cooling system Allow Easy Retrofit In many cases, no requirement to replace existing raised floor cooling infrastructure Components fit through standard doorways Fits existing DCF™ and DCM™ racks Leverage Redundancy/ Availability Utilize existing cooling redundancy of raised floor air distribution and high availability cooling infrastructure Retrofit existing racks with Liebert Aisle Containment Provide Fast Return on Investment (ROI) Payback within a few months to less than 2 years Low initial investment 3 Compare the Costs of a Conventional Data Center Design Versus the SmartAisle™ Solution with Aisle Containment SmartAisle from Emerson Network Power is an intelligent, integrated infrastructure using row-based building blocks. Aisle Containment optimizes efficiency and lowers energy expenses in the SmartAisle solution. Conventional Precision Cooling AC Power Number of Racks: 27 Density: 5.9 per rack Total IT Load: 160 kW Cooling units: 4 x 20 ton Precision Cooling systems Units Power: 2 x 100 kVA room-level UPS systems and power distribution Racks and Integrated Cabinets Cold Aisle Hot Aisle Cold Aisle Hot Aisle Conventional Data Center Design SmartAisle Design Cost Savings "% Advantage SmartAisle" Room Costs $515,000 $459,000 $56,000 11% Infrastructure Costs $415,000 $391,000 $24,000 6% Total Capital Expense $930,000 $850,000 $80,000 9% Energy Consumption $63,500 $46,500 $17,000 27% 5 Year OpEx $318,000 $233,000 $85,000 27% 5 Year TCO $1,248,000 $1,083,000 $165,000 13% Aisle Case 2: SmartAisle SmartAisle 4 Number of Racks: 16 Density: 10kW per rack Total IT Load: 160 kW Cooling units: 6 row-based precision cooling units Cold Aisle Containment Power: 2 Row-based UPS systems Modular Power Busway Measurable Energy Efficiency 75˚F Liebert® Precision Cooling with Liebert iCOM® control and Aisle Containment 89˚F 8 89 ˚F 70˚FF 70˚F 70˚FF 70˚F Precision Precision CoolingCooling 54˚F 89˚F 8 89 ˚F 100% Fan Speed 100% Fan Speed 54˚F IT Racks IT Racks IT Racks IT Racks 75˚F 97º F 97º F 62º F CMF 67% Precision Cooling Traditional Operation 54˚F 85º F 54˚F With Cold Aisle Containment 62º F 85˚F 94˚F 80˚F 80˚F Requires less fan power per kW of cooling Leverages variable fan speed control Precision Precision CoolingCooling 62˚F 94˚F IT Racks IT Racks IT Racks IT Racks 62˚F 90% Fan Speed 90% Fan Speed 85˚F 62˚F O perates with digital scroll technology for variable capacity control Provides continuous dynamic adaptation to cooling load Allows you to easily take advantage of free cooling designs 62˚F Savings - Direct Expansion System With Cold Aisle Containment With Liebert iCOM and Containment 69.7% 50.9% 50.4% 9.3% 9.3% 9.3% 92˚F 92˚F Compressor Condensor 62˚F Evaporator Fan 97˚F 67% Fan Speed 67% Fan Speed Traditional Approach 66.9% 21% 33% Traditional Approach With Cold Aisle Containment With Liebert iCOM and Containment Chiller* 71.3% 64.9% 60% Pumps* 10.0% 5.4% 5.2% Air Handler Fan 18.7% 14.3% 7.2% Total 100% 84.6% 72.4% 15% 28% Savings 97˚F 85˚F 85˚F Savings - Chilled Water System Precision Precision CoolingCooling 7.2% 78.7% 62˚F IT Racks IT Racks 18.5% 100% IT Racks IT Racks 21.0% Total 62˚F 62˚F Savings * Estimated savings based on dedicated data center chiller 5 Enhanced Performance and Management of Dynamic IT Spaces structure Infra Managem ent Remote Monitoring Alarm notification Remote Control Capacity planning Asset management Expert services Surge Protection Power Today’s successful businesses depend on adaptable technologies to help them respond quickly to market demands. Your data center must be built on a support infrastructure designed to match the power and cooling needs of rapidly changing IT initiatives such as virtualization and consolidation. Each IT change, move or addition will affect the entire support infrastructure—you need products and support that ensure your IT systems will operate reliably in these environments. Cooling Heat UPS PDU Pow er & C oo ling Infrastru e ctur Emerson Network Power leads the industry in infrastructure support, with a comprehensive offering that provides efficient operation without compromising availability. These solutions are backed by the industry’s largest service organization, ensuring continued support by factorytrained experts. IT Racks and Accessories DCF™ & DCM™ IT Rack Industry leading 83% perforation for high density IT equipment Dozens of simple tool-less accessories Significant zero-U mounting space Roof designed for optional high density cooling Liebert® and Knurr Rack PDUs B asic, controlled or adaptive designs Local and remote monitoring Additional in-rack sensors available Available in low and high density 2-year no-hassle replacement warranty 6 Aisle Containment from Emerson Network Power Flexible design independent from rack width Sliding or vertical doors Modular, vertical or retractable overhead containment Integrated adaptive control reduces fan energy cost Liebert MB™ Modular Busway Tool-less mounting to Knurr racks Plug-n-play bus plug / rack PDU connections Replaces multiple power cables Available in dual bus design Power and UPS Liebert® FDC™/ Liebert FPC™ Rack-size power conditioning and distribution Requires only front and back service access Offers top or bottom cable entry Liebert APM™ UPS Liebert NX™ UPS Scalable capacity growth without increasing footprint: 15-90kW Scalable capacity growth without increasing footprint: 40-200kVA Operates with up to 94% energy efficiency Parallel configurations for capacity or redundancy Row-based installation O perates with up to 97% energy efficiency Row-based installation Precision Cooling Liebert CRV™ Row-Based Cooling 20kW to 40kW precision cooling with horizontal airflow design for both non-raised and raised floors Digital scroll compressor and variable speed fans for highly efficient operation Air, water, glycol and chilled water designs Liebert iCOM® for intelligent control, communications and monitoring Liebert XD™ Row-based Cooling High heat density cooling system that requires little to no data center footprint Additional energy savings with pumped refrigerant technology Intelligent fan control in each module and Liebert iCOM for intelligent control, communications and monitoring Liebert DS™ Perimeter Cooling Industry standard in floor mount precision cooling. Available in single units from 28kW to 105kW Flexibility of design with air, water, glycol and GLYCOOL cooling Liebert iCOM for intelligent control, communications and monitoring Digital scroll technology for variable capacity control Widest variety of air supply configurations Liebert CW™ Perimeter Cooling C hilled Water cooling Available in single units from 26kW to 181kW Optional EC Plug Fans maximize energy efficient operation Liebert iCOM for intelligent control, communications and monitoring Widest variety of air supply configurations Infrastructure Management Liebert Nform™ Liebert SiteScan™ Web Software solution providing Software solution providing centralized monitoring of a wide range of data center infrastructure equipment centralized monitoring of a wide range of data center infrastructure equipment Leverages existing network Leverages existing network communications Triggers event actions or notifications communications Triggers event actions or notifications 7 Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity™ from grid to chip for telecommunication networks, data centers, health care and industrial facilities. Emerson Network Power provides innovative solutions and expertise in areas including AC and DC power and precision cooling systems, embedded computing and power, integrated racks and enclosures, power switching and controls, infrastructure management, and connectivity. All solutions are supported globally by local Emerson Network Power service technicians. Liebert AC power, precision cooling and monitoring products and services from Emerson Network Power deliver Efficiency Without Compromise™ by helping customers optimize their data center infrastructure to reduce costs and deliver high availability. Emerson Network Power Liebert Corporation World Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 United States Of America 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX [email protected] Emerson Network Power Caribbean and Latin America Office – United States of America +1-954-984-3452 Phone [email protected] Emerson Network Power European Headquarters Office – Italy +39 049 9719 111 Phone +39 049 5841 257 FAX [email protected] Emerson Network Power Asia Pacific Office – Phillipines +63 2 687 6615 +63 2 730 9572 FAX [email protected] liebert.com 24 x 7 Tech Support 800 222 5877 Phone 614 841 6755 (outside U.S.) While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2012 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names and logos referred to herein are trade names, trademarks or registered trademarks of their respective owners. ® Liebert is a registered trademark of the Liebert Corporation. SL-11421 (R09/12) Printed in USA Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2012 Emerson Electric Co. Emerson Network Power. The global leader in enabling Business-Critical Continuity™. AC Power Connectivity DC Power Embedded Computing Embedded Power Industrial Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls EmersonNetworkPower.com Precision Cooling Racks & Integrated Cabinets Services