DISCONTINUED PRODUCT Infrastructure Management & Monitoring For Business-Critical Continuity™ Liebert® iCOM-DO™ User Manual DISCONTINUED PRODUCT TABLE OF CONTENTS 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.1 Retrofit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.1.1 System Wiring—All Liebert iCOM Controllers . . . . . . . . . . . . 2 3.0 CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3.1 DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3.2 Diagnostic LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3.3 Piezoelectric Horn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4.0 OUTPUTS - STATUS AND ALARMS . . . . . . . . . . . . . . . . . 5 FIGURES Figure 1 Figure 2 Typical system configuration . . . . . . . . . . . . . . . . . . . . . . . 1 ELV wiring for Liebert iCOM-DO . . . . . . . . . . . . . . . . . . . 3 TABLES Figure 3 Figure 4 Typical system configuration . . . . . . . . . . . . . . . . . . . . . . . 1 ELV wiring for Liebert iCOM-DO . . . . . . . . . . . . . . . . . . . 3 i DISCONTINUED PRODUCT ii DISCONTINUED PRODUCT Introduction 1.0 INTRODUCTION The Liebert iCOM Discrete Output interface card provides discrete outputs for Liebert Precision Cooling units equipped with a Liebert iCOM control. Operating status is monitored and critical alarms are communicated via contact closure. Any alarm monitor, I/O panel, autodialer or monitoring system can be used to monitor your Liebert unit. The Liebert iCOM-DO card is available as a factory-installed option or in a kit for field-retrofit to Liebert Precision Cooling units equipped with the Liebert iCOM control. Figure 1 Typical system configuration Liebert iCOM-DO Interface Card Dry-Contact Discrete Outputs to: • BMS Interface • Alarm Panel • Autodialer , etc. 2-Wire Connection Per Alarm Liebert Precision Cooling Unit Table 1 Specifications Electrical Requirements Voltage 24VAC or 24VDC, ±20% 50/60 Hz, Single Phase Power 10W maximum Environmental Conditions, °C (F) Operating 5 to 55 (41 to 131) Temp. Storage Temp. -20 to 70 (-4 to 158) Humidity: 10% to 95% RH (non-condensing) Dimensions, mm (inches) Card Only 178 x 102 x 38 (7.0 x 4.0 x 1.5) Shipping 248 x 178 x 64 (9.75 x 7.0 x 2.5) Weight, kg (lb) Net 0.1 (0.2) Shipping 0.6 (1.3) Precision Cooling units with Liebert iCOM control and Compatibility software version # PA1.04.022 STD or newer 16 Form-C Contact Closures (SPDT Relays, energize to alarm) Discrete Rating: 1A @ 30VDC; 0.46A @ 65 VDC; 0.46 A @ 150VAC Outputs 16-24 AWG (1.5mm2 - 0.25mm2)wiring 1 DISCONTINUED PRODUCT Installation 2.0 INSTALLATION As a retrofit kit, the Liebert iCOM-DO is secured to a metal mounting plate. The mounting plate is then attached to a flat metal surface in the extra low voltage (ELV) section of the Liebert unit. If the Liebert iCOM-DO was ordered as a factory-installed option, proceed to 3.0 - Configuration. 2.1 Retrofit Installation Position the Liebert iCOM-DO in the low voltage/control cavity of the Liebert Precision Cooling unit. Use three #8 x 3/8" sheet metal screws to attach the mounting plate to the Liebert Precision Cooling unit. 2.1.1 System Wiring—All Liebert iCOM Controllers Two wiring harnesses are included with the retrofit kit, one for the power connection and one for CAN communication. Refer to Figure 2 for details on routing the wiring. Power Connection The harness supplied with the Liebert iCOM-DO interface card (P/N 159084G1) is equipped with three connectors, one at either end of the harness and one in the middle. The harness taps power from the 24VAC input to the control board of the Liebert Precision Cooling unit. To connect this power to the Liebert iCOM-DO: 1. Locate the connector containing the two red wires plugged into P43 on the control board and unplug it. Reconnect it to the connector in the middle of the supplied harness. 2. Plug one end of this harness into P43 on the control board and the other end into TB100 of the Liebert iCOM-DO. NOTICE Risk of improper wiring. Can cause equipment damage. Do not tap power from the auxiliary 24VAC Terminals T5/G5 on the Liebert iCOM. Powering from this source might damage the controller and interface card. Communication Connection The second wiring harness provided (P/N 197975G1) has a connector fitted at either end and is the communications connection between the unit microprocessor and the Liebert iCOM-DO. 2 DISCONTINUED PRODUCT Installation To put it in the system: 1. Connect the RJ-type connector to the Liebert iCOM control board at either the P66 or P67 connection if unit is equipped with a small display. If unit is equipped with a large display, connect the RJ-type connector to the CAN connector on the back of the large display. 2. Connect the MTA-style connector of the wire harness to TB102 of the Liebert iCOM-DO interface card. Figure 2 ELV wiring for Liebert iCOM-DO Connect 24VAC power from P45 on the fuse board to P43 on the unit control board Liebert iCOM control Connect CAN Bus to P66 or P67 on the back of Liebert iCOM control Fuse Board Liebert Precision Cooling unit control board Route 24VAC power from P43 on the cooling unit control board to TB100 on the Liebert iCOM-DO board Liebert iCOM-DO board Route CAN Bus communications from P999 on the Liebert iCOM-DO board to P66 or P67 on the back of the Liebert iCOM control 3 DISCONTINUED PRODUCT Configuration 3.0 CONFIGURATION The Liebert iCOM-DO can function with either Liebert SiteLink® or Liebert IntelliSlot® monitoring cards. The Liebert iCOM-DO outputs can be configured only from the large Liebert iCOM display. The small Liebert iCOM display cannot be used to configure the Liebert iCOM-DO outputs. Refer to the Liebert iCOM manual, SL-18835, for details. The document is available at Liebert’s Web site: www.liebert.com 3.1 DIP Switch Settings The Liebert iCOM currently supports one connected Liebert iCOM-DO. The Liebert iCOM-DO is configured at the factory with all switches in the OFF position (default is OFF). No DIP switch changes are necessary. The Liebert iCom control uses the default address and will automatically detect the Liebert iCOM-DO when it is connected. Refer to the Liebert iCOM manual for details. 3.2 Diagnostic LEDs LEDs are provided on the interface card to provide information for diagnostic purposes. The following table summarizes their indications: Table 2 Diagnostic LED indications LED Identifier 3.3 Description DS1 CAN Receive Active DS2 CAN Transmit Active DS3 +12V Isolated Power On DS4 24VAC or 24VDC Power Supply On DS5 +5V Logic Power On Piezoelectric Horn The jumper, P5, located adjacent to the piezoelectric buzzer, is used to enable or disable operation of the audible alarm. The card ships with the buzzer disabled. With the jumper connecting the two pins of P5, the audible alarm is enabled. The buzzer will be activated whenever there is an alarm for TB1-TB15. NOTE The buzzer should be enabled only for use during troubleshooting. 4 DISCONTINUED PRODUCT Outputs - Status and Alarms 4.0 OUTPUTS - STATUS AND ALARMS A three-position screw terminal block is provided for each Form-C contact closure output. The wiring connection is uniform for all 16 outputs: Position 1: Common Position 2: Normally Closed Position 3: Normally Open Position 1 is the left-most connection, and is marked by a triangular symbol on the circuit board. The outputs are not supervised (except as noted below); thus, the N.O. contact would be closed only upon an active/alarm condition. Refer to Table 3 for the standard mapping of status and alarms. The output terminal block (TB) for each alarm output is configurable. For details, refer to the Liebert iCOM manual, SL-18835, available at Liebert’s Web site: www.liebert.com NOTE The top of the screw terminals cannot be used to obtain contact when using a meter to verify the status of a contact closure. The meter must contact the terminal block in the openings where the wires are inserted. Table 3 Standard mapping of status and alarms Terminal Block Description Liebert iCOM TB1 Cooling Status ✔ TB2 Heating Status ✔ TB3 Humidifying Status ✔ TB4 Dehumidifying Status ✔ TB5 High Temperature ✔ TB6 High Humidity ✔ TB7 Low Temperature ✔ TB8 Low Humidity ✔ TB9a High Head Pressure C1 ✔ TB9b High Head Pressure C2 ✔ TB10 Loss of Airflow ✔ TB11 Change Filters ✔ TB12 Water Detected/Customer Alarm 1 ✔ TB13 Customer Alarm 2 ✔ TB14 GLYCOOL Status ✔ TB15 Unit On ✔ 5 DISCONTINUED PRODUCT Outputs - Status and Alarms 6 DISCONTINUED PRODUCT DISCONTINUED PRODUCT Ensuring The High Availability Of Mission-Critical Data And Applications. Technical Support / Service Locations Web Site www.liebert.com Monitoring 800-222-5877 [email protected] Outside the US: 614-841-6755 Single-Phase UPS 800-222-5877 [email protected] Outside the US: 614-841-6755 Three-Phase UPS 800-543-2378 [email protected] Environmental Systems 800-543-2778 Outside the United States 614-888-0246 United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy +39 049 9719 111 Fax: +39 049 5841 257 Asia 29/F, The Orient Square Building F. Ortigas Jr. Road, Ortigas Center Pasig City 1605 Philippines +63 2 687 6615 Fax: +63 2 730 9572 While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2010 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert is the registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-28096_REV1_07-10 Emerson Network Power. The global leader in enabling Business-Critical Continuity™. EmersonNetworkPower.com AC Power Systems Outside Plant Connectivity Power Switching & Control DC Power Systems Precision Cooling Embedded Computing Racks & Integrated Cabinets Embedded Power Services Infrastructure Management & Monitoring Surge Protection Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2010 Emerson Electric Co. DISCONTINUED PRODUCT