EasyPoint TM N40P107 Single Module (without IC, with push button) 1 General Description EasyPoint™ N40P107 is a miniature joystick module concept based on contact-less, magnetic movement detection. The two-dimensional linear encoder IC AS5013 is mounted on the bottom side of the application’s PCB, and monitors the movement of the magnet incorporated into the knob and provides directly the x and y coordinates via I²C output. An integrated mechanical push button built in the module provides a “select” function. Figure 1. N40P107-xxxxx-H 2 Key Features Small form factor Lateral Direct Push magnet movement radius up to ±1mm knob force feedback button output SMD mounting 3 Applications The EasyPoint™ N40P107 in combination with the AS5013 is ideal for small form factor navigation user interfaces in battery driven portable devices, such as - Mobile phones (especially for gaming), Remote Controls, Gaming Consoles, Analog joysticks(360 degree), MP3 players, PDAs, PND, MID and GPS 4 Benefits High reliability due to magnetic contact-less sensing Easy to use and fast integration Figure 2. Typical Application Diagram N40P107 EPTM module footprint Main Board (PCB) AS5013 (IC) www.ams.com Revision 1.6 1-8 EasyPoint TM N40P107 Datasheet - E l e c t r i c a l C h a r a c t e r i s t i c s 5 Electrical Characteristics 5.1 Mechanical Specifications Table 1. Mechanical Specifications Parameter Note Number of operating shafts Single shaft Shaft material LPC Housing material LPC & PA46 Shell material Stainless Steel or Copper alloy Travel (XY operation) ±1.00mm (±10%) Travel (Z push operation) 0.22mm (±0.05mm) Directional operating force (XY direction) 0.35N (±0.10N) or 0.55N (±0.15N) Push operating force (Z direction) 1.80N (±15%) Vibration 10-500-10Hz 15 minutes, 12 cycles, 3 axes (total 36 cycles) Operating life – XY direction Each direction > 1 million cycles Operating life – Push Z direction > 1 million cycles Shaft strength (XYZ direction) > 5.0kgf Over force 1.5kgf > 100k cycles 5.2 Electrical Specifications Table 2. Electrical Specifications Parameter Min Contact resistance Max Unit Note 500 mΩ Norm: EIA-364-23 Dielectric withstanding voltage 100 Vac Norm: EIA-364-20 Insulation resistance 100 MΩ Norm: EIA-364-21, 100Vdc ms Rate: 2 times/sec. Bouncing (On/Off) 5 5.3 Environmental Specifications Table 3. Environmental Specifications www.ams.com Parameter Note Operating temperature range -20 ~ +70ºC Storage temperature range -40 ~ +85ºC Humidity non-condensing 5 ~ 85% RH Degrees of protection IP 5X Revision 1.6 2-8 EasyPoint TM N40P107 Datasheet - E l e c t r i c a l C h a r a c t e r i s t i c s 5.4 Recommended Reflow Temperature Profile Figure 3. Reflow Temperature Profile 250 ~ 260°C 60 sec. MAX. 217ºC 170ºC 140ºC 60 ~ 120 sec. 10 sec. MAX. Pre-Heating Soldering Time Notes: 1. Do not wash the module! Do not use flux cleaner or solder paste remover! 2. Maximum 3 passes through reflow oven. www.ams.com Revision 1.6 3-8 EasyPoint TM N40P107 Datasheet - A p p l i c a t i o n U s i n g A S 5 0 1 3 2 D L i n e a r E n c o d e r 6 Application Using AS5013 2D Linear Encoder Figure 4. Application Diagram For further information, please refer to the ams AS5013 encoder application note AN5013-20: http://www.ams.com/eng%29/Products/Position-Sensors/EasyPoint-Joystick-Position-Sensor/AS5013/Technical-Documents/EasyPointAS5013-Downloads www.ams.com Revision 1.6 4-8 EasyPoint TM N40P107 Datasheet - P a c k a g e D r a w i n g s a n d M a r k i n g s 7 Package Drawings and Markings Figure 5. N40P107 Dimensions (mm ±0.15) 2012 DC RoHS Figure 6. Recommended PCB Layout (mm ±0.05) & Circuit Diagram 2012.08.07 DCC發行 www.ams.com Revision 1.6 5-8 EasyPoint TM N40P107 Datasheet - P a c k a g e D r a w i n g s a n d M a r k i n g s Figure 7. Recommended on Casing Design Speedtech 2012.08.07 DCC發行 AS5013 Figure 8. Recommended Stencil Design for 4 GND-Pads www.ams.com Revision 1.6 6-8 EasyPoint TM N40P107 Datasheet - R e v i s i o n H i s t o r y Revision History Revision Date 1.0 25 May, 2011 1.1 21 Jun, 2011 1.2 19 Oct, 2011 Added logos to Package Drawings and Markings on page 5 1.3 05 Jan, 2012 Changed logos in Package Drawings and Markings on page 5 1.4 17 Jan, 2012 1.5 19 Jun 2012 1.6 Owner Description Initial release abi rph Minor changes on text and format Added note to Recommended Reflow Temperature Profile on page 3 Updated Key Features on page 1 and Figure 4 19 Aug, 2013 Updated Figure 5 23 Apr, 2014 Updated link under Figure 4 Note: Typos may not be explicitly mentioned under revision history. www.ams.com Revision 1.6 7-8 EasyPoint TM N40P107 Datasheet - C o p y r i g h t s & D i s c l a i m e r Copyrights & Disclaimer Copyright ams AG, Tobelbader Strasse 30, 8141 Unterpremstaetten, Austria-Europe. Trademarks Registered. All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. Devices sold by ams AG are covered by the warranty and patent indemnification provisions appearing in its Term of Sale. ams AG makes no warranty, express, statutory, implied, or by description regarding the information set forth herein. ams AG reserves the right to change specifications and prices at any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with ams AG for current information. This product is intended for use in commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment are specifically not recommended without additional processing by ams AG for each application. This product is provided by ams AG “AS IS” and any express or implied warranties, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose are disclaimed. ams AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise or flow out of ams AG rendering of technical or other services. Contact Information: Headquarters ams AG Tobelbaderstrasse 30 8141 Unterpremstaetten Austria, Europe Tel: +43 (0) 3136 500 0 Website: www.ams.com www.ams.com Revision 1.6 8-8