EasyPoint N40P107

EasyPoint
TM
N40P107
Single Module (without IC, with push button)
1 General Description
EasyPoint™ N40P107 is a miniature joystick module concept based
on contact-less, magnetic movement detection. The two-dimensional
linear encoder IC AS5013 is mounted on the bottom side of the
application’s PCB, and monitors the movement of the magnet
incorporated into the knob and provides directly the x and y
coordinates via I²C output. An integrated mechanical push button
built in the module provides a “select” function.
Figure 1. N40P107-xxxxx-H
2 Key Features
Small
form factor
Lateral
Direct
Push
magnet movement radius up to ±1mm
knob force feedback
button output
SMD mounting
3 Applications
The EasyPoint™ N40P107 in combination with the AS5013 is ideal
for small form factor navigation user interfaces in battery driven
portable devices, such as - Mobile phones (especially for gaming),
Remote Controls, Gaming Consoles, Analog joysticks(360 degree),
MP3 players, PDAs, PND, MID and GPS
4 Benefits
High reliability due to magnetic contact-less sensing
Easy to use and fast integration
Figure 2. Typical Application Diagram
N40P107
EPTM module footprint
Main Board (PCB)
AS5013 (IC)
www.ams.com
Revision 1.6
1-8
EasyPoint
TM
N40P107
Datasheet - E l e c t r i c a l C h a r a c t e r i s t i c s
5 Electrical Characteristics
5.1 Mechanical Specifications
Table 1. Mechanical Specifications
Parameter
Note
Number of operating shafts
Single shaft
Shaft material
LPC
Housing material
LPC & PA46
Shell material
Stainless Steel or Copper alloy
Travel (XY operation)
±1.00mm (±10%)
Travel (Z push operation)
0.22mm (±0.05mm)
Directional operating force (XY direction)
0.35N (±0.10N) or 0.55N (±0.15N)
Push operating force (Z direction)
1.80N (±15%)
Vibration
10-500-10Hz 15 minutes, 12 cycles, 3 axes (total 36 cycles)
Operating life – XY direction
Each direction > 1 million cycles
Operating life – Push Z direction
> 1 million cycles
Shaft strength (XYZ direction)
> 5.0kgf
Over force
1.5kgf > 100k cycles
5.2 Electrical Specifications
Table 2. Electrical Specifications
Parameter
Min
Contact resistance
Max
Unit
Note
500
mΩ
Norm: EIA-364-23
Dielectric withstanding voltage
100
Vac
Norm: EIA-364-20
Insulation resistance
100
MΩ
Norm: EIA-364-21, 100Vdc
ms
Rate: 2 times/sec.
Bouncing (On/Off)
5
5.3 Environmental Specifications
Table 3. Environmental Specifications
www.ams.com
Parameter
Note
Operating temperature range
-20 ~ +70ºC
Storage temperature range
-40 ~ +85ºC
Humidity non-condensing
5 ~ 85% RH
Degrees of protection
IP 5X
Revision 1.6
2-8
EasyPoint
TM
N40P107
Datasheet - E l e c t r i c a l C h a r a c t e r i s t i c s
5.4 Recommended Reflow Temperature Profile
Figure 3. Reflow Temperature Profile
250 ~ 260°C
60 sec. MAX.
217ºC
170ºC
140ºC
60 ~ 120 sec.
10 sec. MAX.
Pre-Heating
Soldering Time
Notes:
1. Do not wash the module! Do not use flux cleaner or solder paste remover!
2. Maximum 3 passes through reflow oven.
www.ams.com
Revision 1.6
3-8
EasyPoint
TM
N40P107
Datasheet - A p p l i c a t i o n U s i n g A S 5 0 1 3 2 D L i n e a r E n c o d e r
6 Application Using AS5013 2D Linear Encoder
Figure 4. Application Diagram
For further information, please refer to the ams AS5013 encoder application note AN5013-20:
http://www.ams.com/eng%29/Products/Position-Sensors/EasyPoint-Joystick-Position-Sensor/AS5013/Technical-Documents/EasyPointAS5013-Downloads
www.ams.com
Revision 1.6
4-8
EasyPoint
TM
N40P107
Datasheet - P a c k a g e D r a w i n g s a n d M a r k i n g s
7 Package Drawings and Markings
Figure 5. N40P107 Dimensions (mm ±0.15)
2012
DC
RoHS
Figure 6. Recommended PCB Layout (mm ±0.05) & Circuit Diagram
2012.08.07
DCC發行
www.ams.com
Revision 1.6
5-8
EasyPoint
TM
N40P107
Datasheet - P a c k a g e D r a w i n g s a n d M a r k i n g s
Figure 7. Recommended on Casing Design
Speedtech
2012.08.07
DCC發行
AS5013
Figure 8. Recommended Stencil Design for 4 GND-Pads
www.ams.com
Revision 1.6
6-8
EasyPoint
TM
N40P107
Datasheet - R e v i s i o n H i s t o r y
Revision History
Revision
Date
1.0
25 May, 2011
1.1
21 Jun, 2011
1.2
19 Oct, 2011
Added logos to Package Drawings and Markings on page 5
1.3
05 Jan, 2012
Changed logos in Package Drawings and Markings on page 5
1.4
17 Jan, 2012
1.5
19 Jun 2012
1.6
Owner
Description
Initial release
abi
rph
Minor changes on text and format
Added note to Recommended Reflow Temperature Profile on page 3
Updated Key Features on page 1 and Figure 4
19 Aug, 2013
Updated Figure 5
23 Apr, 2014
Updated link under Figure 4
Note: Typos may not be explicitly mentioned under revision history.
www.ams.com
Revision 1.6
7-8
EasyPoint
TM
N40P107
Datasheet - C o p y r i g h t s & D i s c l a i m e r
Copyrights & Disclaimer
Copyright ams AG, Tobelbader Strasse 30, 8141 Unterpremstaetten, Austria-Europe. Trademarks Registered. All rights reserved. The material
herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner.
Devices sold by ams AG are covered by the warranty and patent indemnification provisions appearing in its Term of Sale. ams AG makes no
warranty, express, statutory, implied, or by description regarding the information set forth herein. ams AG reserves the right to change
specifications and prices at any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with
ams AG for current information. This product is intended for use in commercial applications. Applications requiring extended temperature range,
unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment are
specifically not recommended without additional processing by ams AG for each application. This product is provided by ams AG “AS IS” and
any express or implied warranties, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose are
disclaimed.
ams AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of
profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out
of the furnishing, performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise or flow out of
ams AG rendering of technical or other services.
Contact Information:
Headquarters
ams AG
Tobelbaderstrasse 30
8141 Unterpremstaetten
Austria, Europe
Tel: +43 (0) 3136 500 0
Website: www.ams.com
www.ams.com
Revision 1.6
8-8