Model 6120 Series

Model 6120
Position Sensor
7/8” Diameter
Non-Contacting Hall Effect
Single Turn
MODEL STYLES AVAILABLE
6121
1/8” Shaft, 1/4” Bushing
6124
6 mm Shaft, 3/8” Bushing
6126
1/8” Shaft, 3/8” Bushing
6127
1/4” Shaft, 3/8” Bushing
612x-XXXX
Custom models are available; Contact Customer Service for special features
ELECTRICAL1
Output Voltage
0.2 Vdc (4%) to 4.8 Vdc (96%) Typical (see Feature Codes table)
Output Overvoltage Limits
10 Vdc to -0.3 Vdc; output may be shorted to ground or supply without damage
Output Current
±8 mA Max.
Output Load
1 kΩ Min., 10 kΩ Typical
Operating Input Voltage Range
4.5 to 5.5 Vdc
Supply Voltage Absolute Limits
20 Vdc Max., -10 Vdc Min.
Independent Linearity2
±0.5% (0.25% Available)
Hysteresis
0.2% Max.
Resolution
0.088° for 360° travel, 0.011° for 45° travel
Supply Current
8.5 mA Typical, 12 mA Max.
Dielectric Strength
750 V rms
Insulation Resistance
1,000 MegΩ Min.
Electrostatic Discharge (ESD)
Passes 2 kV human body model and 15 kV air discharge
Bulk Current Injection (BCI)
Passes 2-500 MHz at 200 mA
Actual Electrical Travel
360° Typical (see Ordering Information)
Temperature Coefficient of Output Voltage
± 20 ppm/°C
MECHANICAL
Total Mechanical Travel
360° Continuous (320° with stop feature)
Bearing
Bearing Bronze Bushing
Weight
0.6 oz. Typical
Static Stop Strength
1
2
40 in. oz.
Panel Nut Tightening Torque
25 in. lb. Max.
Rotational Speed
500 RPM Max.
Specifications subject to change without notice.
Linearity is measured between 1% and 99% of input voltage.
BI Technologies Corporation
4200 Bonita Place, Fullerton, CA 92835 USA
Phone: 714 447 2345
February 19, 2015
Website: www.bitechnologies.com
Model 6120 page 1 of 3
RoHS 2
Pb compliant
Model 6120
ENVIRONMENTAL
Operating Temperature Range
-40°C to +125°C
Shock
Per MIL R-39023, 6 ms Saw-tooth 100 G’s
Vibration
Per MIL R-39023, 10 G’s, 100 to 500 Hz
Moisture Resistance, Powered
Per MIL 202G, Method 106G
Rotational Life
10 million shaft revolutions with up to 8 oz sideload
Storage Temperature Range
-55°C to +125°C
Ingress Protection Rating (IP Code)
IP50, IP66 available as option (feature code ES)
ORDERING INFORMATION
6127 V1 A360 L.5 XX
Model Series
Optional Feature Code
(see table)
Voltage Output Code (see table)
Linearity, Independent
Electrical Angle (35 to 360 degrees,
smaller angles are possible, consult factory)
FEATURE CODES
Voltage Output Codes
Optional Feature Codes
V0
≤ 3% to ≥ 96%
ST
Stop (320°)
V1
4% to 96%
FS
Flatted Shaft (slot standard)
V2
5% to 95%
LT
Linearity Data
V3
10% to 90%
SL
Shaft Lock 6127 only
V4
15% to 85%
CW
Reverse Direction
V5
20% to 80%
ES
Seal (IP66) 6124 or 6127 only
When multiple Optional Feature codes are used
the P/N shall be in the same sequence as listed
in this table (top to bottom).
When V0 is used the angle specified is the
theoretical angle over which the output
would vary if the output could actually reach
0% and 100% of Vcc.
BI Technologies Corporation
4200 Bonita Place, Fullerton, CA 92835 USA
Phone: 714 447 2345
February 19, 2015
Website: www.bitechnologies.com
Model 6120 page 2 of 3
Model 6120
OUTLINE DRAWING
BI Technologies Corporation
4200 Bonita Place, Fullerton, CA 92835 USA
Phone: 714 447 2345
February 19, 2015
Website: www.bitechnologies.com
Model 6120 page 3 of 3