Model 6120 Position Sensor 7/8” Diameter Non-Contacting Hall Effect Single Turn MODEL STYLES AVAILABLE 6121 1/8” Shaft, 1/4” Bushing 6124 6 mm Shaft, 3/8” Bushing 6126 1/8” Shaft, 3/8” Bushing 6127 1/4” Shaft, 3/8” Bushing 612x-XXXX Custom models are available; Contact Customer Service for special features ELECTRICAL1 Output Voltage 0.2 Vdc (4%) to 4.8 Vdc (96%) Typical (see Feature Codes table) Output Overvoltage Limits 10 Vdc to -0.3 Vdc; output may be shorted to ground or supply without damage Output Current ±8 mA Max. Output Load 1 kΩ Min., 10 kΩ Typical Operating Input Voltage Range 4.5 to 5.5 Vdc Supply Voltage Absolute Limits 20 Vdc Max., -10 Vdc Min. Independent Linearity2 ±0.5% (0.25% Available) Hysteresis 0.2% Max. Resolution 0.088° for 360° travel, 0.011° for 45° travel Supply Current 8.5 mA Typical, 12 mA Max. Dielectric Strength 750 V rms Insulation Resistance 1,000 MegΩ Min. Electrostatic Discharge (ESD) Passes 2 kV human body model and 15 kV air discharge Bulk Current Injection (BCI) Passes 2-500 MHz at 200 mA Actual Electrical Travel 360° Typical (see Ordering Information) Temperature Coefficient of Output Voltage ± 20 ppm/°C MECHANICAL Total Mechanical Travel 360° Continuous (320° with stop feature) Bearing Bearing Bronze Bushing Weight 0.6 oz. Typical Static Stop Strength 1 2 40 in. oz. Panel Nut Tightening Torque 25 in. lb. Max. Rotational Speed 500 RPM Max. Specifications subject to change without notice. Linearity is measured between 1% and 99% of input voltage. BI Technologies Corporation 4200 Bonita Place, Fullerton, CA 92835 USA Phone: 714 447 2345 February 19, 2015 Website: www.bitechnologies.com Model 6120 page 1 of 3 RoHS 2 Pb compliant Model 6120 ENVIRONMENTAL Operating Temperature Range -40°C to +125°C Shock Per MIL R-39023, 6 ms Saw-tooth 100 G’s Vibration Per MIL R-39023, 10 G’s, 100 to 500 Hz Moisture Resistance, Powered Per MIL 202G, Method 106G Rotational Life 10 million shaft revolutions with up to 8 oz sideload Storage Temperature Range -55°C to +125°C Ingress Protection Rating (IP Code) IP50, IP66 available as option (feature code ES) ORDERING INFORMATION 6127 V1 A360 L.5 XX Model Series Optional Feature Code (see table) Voltage Output Code (see table) Linearity, Independent Electrical Angle (35 to 360 degrees, smaller angles are possible, consult factory) FEATURE CODES Voltage Output Codes Optional Feature Codes V0 ≤ 3% to ≥ 96% ST Stop (320°) V1 4% to 96% FS Flatted Shaft (slot standard) V2 5% to 95% LT Linearity Data V3 10% to 90% SL Shaft Lock 6127 only V4 15% to 85% CW Reverse Direction V5 20% to 80% ES Seal (IP66) 6124 or 6127 only When multiple Optional Feature codes are used the P/N shall be in the same sequence as listed in this table (top to bottom). When V0 is used the angle specified is the theoretical angle over which the output would vary if the output could actually reach 0% and 100% of Vcc. BI Technologies Corporation 4200 Bonita Place, Fullerton, CA 92835 USA Phone: 714 447 2345 February 19, 2015 Website: www.bitechnologies.com Model 6120 page 2 of 3 Model 6120 OUTLINE DRAWING BI Technologies Corporation 4200 Bonita Place, Fullerton, CA 92835 USA Phone: 714 447 2345 February 19, 2015 Website: www.bitechnologies.com Model 6120 page 3 of 3