Datasheet - Spansion

S25FL040A
4-Megabit CMOS 3.0 Volt Flash Memory
with 50-MHz SPI (Serial Peripheral Interface) Bus
and Small Sector for Boot and Parameter Storage
S25FL040A Cover Sheet
Data Sheet
This product has been retired and is not recommended for designs. Please contact your Spansion
representative for alternates. Availability of this document is retained for reference and historical
purposes only.
Notice to Readers: This document states the current technical specifications regarding the Spansion
product(s) described herein. Spansion Inc. deems the products to have been in sufficient production volume
such that subsequent versions of this document are not expected to change. However, typographical or
specification corrections, or modifications to the valid combinations offered may occur.
Publication Number S25FL040A_00
Revision B
Amendment 4
Issue Date February 27, 2009
D at a
S hee t
Notice On Data Sheet Designations
Spansion Inc. issues data sheets with Advance Information or Preliminary designations to advise readers of
product information or intended specifications throughout the product life cycle, including development,
qualification, initial production, and full production. In all cases, however, readers are encouraged to verify
that they have the latest information before finalizing their design. The following descriptions of Spansion data
sheet designations are presented here to highlight their presence and definitions.
Advance Information
The Advance Information designation indicates that Spansion Inc. is developing one or more specific
products, but has not committed any design to production. Information presented in a document with this
designation is likely to change, and in some cases, development on the product may discontinue. Spansion
Inc. therefore places the following conditions upon Advance Information content:
“This document contains information on one or more products under development at Spansion Inc.
The information is intended to help you evaluate this product. Do not design in this product without
contacting the factory. Spansion Inc. reserves the right to change or discontinue work on this proposed
product without notice.”
Preliminary
The Preliminary designation indicates that the product development has progressed such that a commitment
to production has taken place. This designation covers several aspects of the product life cycle, including
product qualification, initial production, and the subsequent phases in the manufacturing process that occur
before full production is achieved. Changes to the technical specifications presented in a Preliminary
document should be expected while keeping these aspects of production under consideration. Spansion
places the following conditions upon Preliminary content:
“This document states the current technical specifications regarding the Spansion product(s)
described herein. The Preliminary status of this document indicates that product qualification has been
completed, and that initial production has begun. Due to the phases of the manufacturing process that
require maintaining efficiency and quality, this document may be revised by subsequent versions or
modifications due to changes in technical specifications.”
Combination
Some data sheets contain a combination of products with different designations (Advance Information,
Preliminary, or Full Production). This type of document distinguishes these products and their designations
wherever necessary, typically on the first page, the ordering information page, and pages with the DC
Characteristics table and the AC Erase and Program table (in the table notes). The disclaimer on the first
page refers the reader to the notice on this page.
Full Production (No Designation on Document)
When a product has been in production for a period of time such that no changes or only nominal changes
are expected, the Preliminary designation is removed from the data sheet. Nominal changes may include
those affecting the number of ordering part numbers available, such as the addition or deletion of a speed
option, temperature range, package type, or VIO range. Changes may also include those needed to clarify a
description or to correct a typographical error or incorrect specification. Spansion Inc. applies the following
conditions to documents in this category:
“This document states the current technical specifications regarding the Spansion product(s)
described herein. Spansion Inc. deems the products to have been in sufficient production volume such
that subsequent versions of this document are not expected to change. However, typographical or
specification corrections, or modifications to the valid combinations offered may occur.”
Questions regarding these document designations may be directed to your local sales office.
2
S25FL040A
S25FL040A_00_B4 February 27, 2009
S25FL040A
4-Megabit CMOS 3.0 Volt Flash Memory
with 50-MHz SPI (Serial Peripheral Interface) Bus
and Small Sector for Boot and Parameter Storage
Data Sheet
This product has been retired and is not recommended for designs. Please contact your Spansion representative for alternates.
Availability of this document is retained for reference and historical purposes only.
Distinctive Characteristics
„ Process Technology
Architectural Advantages
– Manufactured on 0.20 µm MirrorBit® process technology
„ Single power supply operation
– Full voltage range: 2.7 to 3.6 V read and program operations
„ Memory Architecture
– 4Mb uniform 64KB sector product: Backward compatible with
S25FL004A 4Mb device; same pin out, command set and uniform
sector size (64KB)
– 4Mb small sector product: Offer Top Boot & Bottom Boot devices;
Seven sectors of 64KB and One 64KB sector (Top or bottom)
broken into two sectors of 16KB each, two sectors of 4KB each, and
two sectors of 12KB each.
„ Program
„ Package Option
–
–
–
–
Industry Standard Pinouts
8-pin SO package (150 mils)
8-pin SO package (208 mils)
8-Contact WSON Package (5 x 6 mm)
Performance Characteristics
„ Speed
– 50 MHz clock rate (maximum)
„ Power Saving Standby Mode
– Page Program (up to 256 bytes) in 1.5 ms (typical)
– Program operations are on a page by page basis
– Standby Mode 20 µA (max)
– Deep Power Down Mode 1.5 µA (typical)
„ Erase
– 0.5 s typical sector erase time
– 3 s typical bulk erase time
Memory Protection Features
„ Memory Protection
„ Cycling Endurance
– W# pin works in conjunction with Status Register Bits to protect
specified memory areas
– Status Register Block Protection bits (BP2, BP1, BP0) in status
register configure parts of memory as read-only
– 100,000 cycles per sector typical
„ Data Retention
– 20 years typical
„ Device ID
– JEDEC standard two-byte electronic signature
– RES command one-byte electronic signature for backward
compatibility
Software Features
– SPI Bus Compatible Serial Interface
General Description
The S25FL040A is a 3.0 Volt (2.7 V to 3.6 V), single-power-supply Flash memory device with with erasable
sectors for boot code and parameter storage.
The device accepts data written to SI (Serial Input) and outputs data on SO (Serial Output). The devices are
designed to be programmed in-system with the standard system 3.0 volt VCC supply.
The memory can be programmed 1 to 256 bytes at a time, using the Page Program command. The device
supports Sector Erase and Bulk Erase commands.
Each device requires only a 3.0 volt power supply (2.7 V to 3.6 V) for both read and write functions. Internally
generated and regulated voltages are provided for the program operations. This device does not require a
VPP supply. The S25FL040A device in uniform 64KB sector configuration is compatible with the S25FL004A
device.
Publication Number S25FL040A_00
Revision B
Amendment 4
Issue Date February 27, 2009
This document states the current technical specifications regarding the Spansion product(s) described herein. Spansion Inc. deems the products to have been in sufficient production volume such that subsequent versions of this document are not expected to change. However, typographical or specification corrections, or modifications to the valid combinations offered may occur.
D at a
S hee t
Table of Contents
Distinctive Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4
1.
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.
Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.
Input/Output Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.
Logic Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.1
Valid Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.
Spansion SPI Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
7.
Device Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.1
Byte or Page Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2
Sector Erase / Bulk Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3
Monitoring Write Operations Using the Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.4
Active Power and Standby Power Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.5
Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.6
Data Protection Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.7
Hold Mode (HOLD#) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.
Sector Address Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
9.
Command Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.1
Read Data Bytes (READ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2
Read Data Bytes at Higher Speed (FAST_READ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.3
Read Identification (RDID) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.4
Read Identification (Read_ID) [RDID Alternate] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.5
Write Enable (WREN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.6
Write Disable (WRDI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.7
Read Status Register (RDSR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.8
Write Status Register (WRSR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.9
Page Program (PP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.10 Sector Erase (SE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.11 Bulk Erase (BE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.12 Deep Power Down (DP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.13 Release from Deep Power Down (RES) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.14 Command Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10.
Power-up and Power-down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
11.
Initial Delivery State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
12.
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
12
12
12
12
12
12
13
14
16
16
17
18
19
20
20
21
22
23
24
25
26
27
29
13.
Operating Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
14.
DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
15.
Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
16.
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
17.
Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17.1 SOA 008—Narrow 8-pin Plastic Small Outline 150 mils Body Width Package . . . . . . . . . . .
17.2 SOC 008—Wide 8-pin Plastic Small Outline 208 mils Body Width Package. . . . . . . . . . . . .
17.3 USON 8L (5 x 6 mm) No-Lead Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18.
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
S25FL040A
36
36
37
38
S25FL040A_00_B4 February 27, 2009
Data
She et
Figures
Figure 2.1
Figure 2.2
Figure 6.1
Figure 6.2
Figure 7.1
Figure 9.1
Figure 9.2
Figure 9.3
Figure 9.4
Figure 9.5
Figure 9.6
Figure 9.7
Figure 9.8
Figure 9.9
Figure 9.10
Figure 9.11
Figure 9.12
Figure 9.13
Figure 9.14
Figure 10.1
Figure 12.1
Figure 12.2
Figure 15.1
Figure 16.1
Figure 16.2
Figure 16.3
Figure 16.4
8-pin Plastic Small Outline Package (SO 150 mil, SO 208 mil) . . . . . . . . . . . . . . . . . . . . . . . . 8
8L USON (5 x 6 mm) Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Bus Master and Memory Devices on the SPI Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SPI Modes Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Hold Mode Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Read Data Bytes (READ) Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Read Data Bytes at Higher Speed (FAST_READ) Command Sequence . . . . . . . . . . . . . . . 17
Read Identification (RDID) Command Sequence and Data-Out Sequence . . . . . . . . . . . . . 18
READ_ID Command Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Write Enable (WREN) Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Write Disable (WRDI) Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Read Status Register (RDSR) Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Write Status Register (WRSR) Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Page Program (PP) Command Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Sector Erase (SE) Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Bulk Erase (BE) Command Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Deep Power Down (DP) Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Release from Deep Power Down (RES) Command Sequence . . . . . . . . . . . . . . . . . . . . . . . 27
Release from Deep Power Down and
Read Electronic Signature (RES) Command Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Power-Up Timing Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Maximum Negative Overshoot Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Maximum Positive Overshoot Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
AC Measurements I/O Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
SPI Mode 0 (0,0) Input Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
SPI Mode 0 (0,0) Output Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
HOLD# Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Write Protect Setup and Hold Timing during WRSR when SRWD=1 . . . . . . . . . . . . . . . . . . 35
February 27, 2009 S25FL040A_00_B4
S25FL040A
5
D at a
S hee t
Tables
Table 5.1
Table 7.1
Table 7.2
Table 7.3
Table 8.1
Table 8.2
Table 8.3
Table 8.4
Table 9.1
Table 9.2
Table 9.3
Table 9.4
Table 9.5
Table 10.1
Table 12.1
Table 13.1
Table 14.1
Table 15.1
Table 16.1
6
S25FL040A Valid Combinations Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
S25FL040A Protected Area Sizes (Top Boot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
S25FL040A Protected Area Sizes (Bottom Boot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
S25FL040A Protected Area Sizes (Uniform Sector) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
S25FL040A Device Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
S25FL040A Sector Address Table (Top Boot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
S25FL040A Sector Address Table (Bottom Boot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
S25FL040A Sector Address Table (Uniform Sectors) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
RDID Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
READ_ID Data-Out Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
S25FL040A Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Protection Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Command Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Power-Up Timing Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Operating Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
DC Characteristics (CMOS Compatible) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Test Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
She et
1. Block Diagram
SRAM
PS
X
D
E
C
Array - L
Array - R
Logic
RD
DATA PATH
February 27, 2009 S25FL040A_00_B4
S25FL040A
HOLD#
VCC
GND
SO
SI
SCK
CS#
IO
7
D at a
2.
S hee t
Connection Diagrams
Figure 2.1 8-pin Plastic Small Outline Package (SO 150 mil, SO 208 mil)
CS#
1
8
VCC
SO
2
7
HOLD#
W#
3
6
SCK
GND
4
5
SI
Figure 2.2 8L USON (5 x 6 mm) Package
8
CS#
1
8
VCC
SO
2
7
HOLD#
W#
3
6
SCK
GND
4
5
SI
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
She et
3. Input/Output Descriptions
Signal Name
SO (Signal Data Output)
I/O
Description
Output Transfers data serially out of the device on the falling edge of SCK.
SI (Serial Data Input)
Input
Transfers data serially into the device. Device latches commands, addresses, and
program data on SI on the rising edge of SCK.
SCK (Serial Clock)
Input
Provides serial interface timing. Latches commands, addresses, and data on SI on
rising edge of SCK. Triggers output on SO after the falling edge of SCK.
CS# (Chip Select)
Input
Places device in active power mode when driven low. Deselects device and places
SO at high impedance when high. After power-up, device requires a falling edge on
CS# before any command is written. Device is in standby mode when a program,
erase, or Write Status Register operation is not in progress.
HOLD# (Hold)
Input
Pauses any serial communication with the device without deselecting it. When driven
low, SO is at high impedance, and all input at SI and SCK are ignored. Requires that
CS# also be driven low.
W# (Write Protect)
Input
Protects the memory area specified by Status Register bits BP2:BP0. When driven
low, prevents any program or erase command from altering the data in the protected
memory area.
VCC
Input
Supply Voltage
GND
Input
Ground
4. Logic Symbol
VCC
SO
SI
SCK
CS#
W#
HOLD#
GND
February 27, 2009 S25FL040A_00_B4
S25FL040A
9
D at a
S hee t
5. Ordering Information
This product has been retired and is not recommended for designs. Please contact your Spansion
representative for alternates. Availability of this document is retained for reference and historical purposes
only.
The ordering part number is formed by a valid combination of the following:
S25FL
040
A
0L
M
A
I
00
1
PACKING TYPE (Note 1)
0
= Tray
1
= Tube
3 =13” Tape and Reel
MODEL NUMBER (Additional Ordering Options)
00 = 64 KBytes Uniform Sector
01 = Top Boot Sector
02 = Bottom Boot Sector
TEMPERATURE RANGE
I
=
Industrial (–40°C to + 85°C)
PACKAGE MATERIALS
A
= Standard
F
= Lead (Pb)-free
PACKAGE TYPE
V
= 8-Pin Plastic Small Outline Package (150 mil)
M
= 8-Pin Plastic Small Outline Package (208 mil)
N
= 8-contact WSON Package
SPEED
0L =
50 MHz
DEVICE TECHNOLOGY
A
= 0.20 µm MirrorBit® Process Technology
DENSITY
040 = 4 Mbit
DEVICE FAMILY
S25FL
SpansionTM Memory 3.0 Volt-only, Serial Peripheral Interface (SPI) Flash Memory
5.1
Valid Combinations
Table 5.1 lists the valid combinations configurations planned to be supported in volume for this device.
Table 5.1 S25FL040A Valid Combinations Table
S25FL040A Valid Combinations
Base Ordering
Part Number
Speed Option
S25FL040A
0L
Package &
Temperature
Model
Number
MAI, MFI,
VAI, VFI,
NAI, NFI
00, 01, 02
Packing Type
Package Marking
(Note 2)
0, 1, 3
(Note 1)
(Note 4) + (Note 3)
FL040A +
Notes
1. Contact your local sales office for availability.
2. Package marking omits leading “S25” and speed, package, and model number form.
3. A for standard package (non-Pb free); F for Pb-free package.
4. I for Uniform Sector product; T for Top Boot product; B for Bottom Boot product.
10
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
She et
6. Spansion SPI Modes
A microcontroller can use either of its two SPI modes to control Spansion SPI Flash memory devices:
„ CPOL = 0, CPHA = 0 (Mode 0)
„ CPOL = 1, CPHA = 1 (Mode 3)
Input data is latched in on the rising edge of SCK, and output data is available from the falling edge of SCK for
both modes.
When the bus master is in standby mode, SCK is as shown in Figure 6.2 for each of the two modes:
„ SCK remains at 0 for (CPOL = 0, CPHA = 0 Mode 0)
„ SCK remains at 1 for (CPOL = 1, CPHA = 1 Mode 3)
Figure 6.1 Bus Master and Memory Devices on the SPI Bus
SO
SPI Interface with
(CPOL, CPHA) =
(0, 0) or (1, 1)
SI
SCK
SCK SO SI
SCK SO SI
SCK SO SI
Bus Master
SPI Memory
Device
CS3
CS2
SPI Memory
Device
SPI Memory
Device
CS1
CS#
W#
HOLD#
CS#
W#
HOLD#
CS#
W#
HOLD#
Note
The Write Protect (W#) and Hold (HOLD#) signals should be driven high (logic level 1) or low (logic level 0) as appropriate.
Figure 6.2 SPI Modes Supported
CS#
CPOL CPHA
Mode 0
0
0
SCK
Mode 3
1
1
SCK
SI
MSB
SO
February 27, 2009 S25FL040A_00_B4
MSB
S25FL040A
11
D at a
S hee t
7. Device Operations
All Spansion SPI devices (S25FL-A) accept and output data in bytes (8 bits at a time).
7.1
Byte or Page Programming
Programming data requires two commands: Write Enable (WREN), which is one byte, and a Page Program
(PP) sequence, which consists of four bytes plus data. The Page Program sequence accepts from 1 byte up
to 256 consecutive bytes of data (which is the size of one page) to be programmed in one operation.
Programming means that bits can either be left at 0, or programmed from 1 to 0. Changing bits from 0 to 1
requires an erase operation. Before this can be applied, the bytes of the memory need to be first erased to all
1’s (FFh) before any programming.
7.2
Sector Erase / Bulk Erase
The Sector Erase (SE) and Bulk Erase (BE) commands set all the bits in a sector or the entire memory array
to 1. While bits can be individually programmed from a 1 to 0, erasing bits from 0 to 1 must be done on a
sector-wide (SE) or array-wide (BE) level.
7.3
Monitoring Write Operations Using the Status Register
The host system can determine when a Write Status Register, program, or erase operation is complete by
monitoring the Write in Progress (WIP) bit in the Status Register. The Read from Status Register command
provides the state of the WIP bit.
7.4
Active Power and Standby Power Modes
The device is enabled and in the Active Power mode when Chip Select (CS#) is Low. When CS# is high, the
device is disabled, but may still be in the Active Power mode until all program, erase, and Write Status
Register operations have completed. The device then goes into the Standby Power mode, and power
consumption drops to ISB. The Deep Power Down (DP) command provides additional data protection against
inadvertent signals. After writing the DP command, the device ignores any further program or erase
commands, and reduces its power consumption to IDP.
7.5
Status Register
The Status Register contains the status and control bits that can be read or set by specific commands
(Table 9.3, S25FL040A Status Register on page 21):
„ Write In Progress (WIP): Indicates whether the device is performing a Write Status Register, program or
erase operation.
„ Write Enable Latch (WEL): Indicates the status of the internal Write Enable Latch.
„ Block Protect (BP2, BP1, BP0): Non-volatile bits that define memory area to be software-protected
against program and erase commands.
„ Status Register Write Disable (SRWD): Places the device in the Hardware Protected mode when this bit
is set to 1 and the W# input is driven low. In this mode, the non-volatile bits of the Status Register (SRWD,
BP2, BP1, BP0) become read-only bits.
12
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
7.6
She et
Data Protection Modes
Spansion SPI Flash memory devices provide the following data protection methods:
„ The Write Enable (WREN) command: Must be written prior to any command that modifies data. The
WREN command sets the Write Enable Latch (WEL) bit. The WEL bit resets (disables writes) on power-up
or after the device completes the following commands:
– Page Program (PP)
– Sector Erase (SE)
– Bulk Erase (BE)
– Write Disable (WRDI)
– Write Status Register (WRSR)
„ Software Protected Mode (SPM): The Block Protect (BP2, BP1, BP0) bits define the section of the
memory array that can be read but not programmed or erased. Table 7.1 and Table 7.2 show the sizes and
address ranges of protected areas that are defined by Status Register bits BP2:BP0.
„ Hardware Protected Mode (HPM): The Write Protect (W#) input and the Status Register Write Disable
(SRWD) bit together provide write protection.
„ Clock Pulse Count: The device verifies that all program, erase, and Write Status Register commands
consist of a clock pulse count that is a multiple of eight before executing them.
Table 7.1 S25FL040A Protected Area Sizes (Top Boot)
Status Register
Block Protect Bits
Memory Array
Protected
Address Range
Unprotected
Address Range
Unprotected
Sectors
(0) None
00000–7FFFF
SA12:SA0
None (0)
(1) SA12
00000–7BFFF
SA11:SA0
Upper 1/32 (16 KB)
(2) SA12:SA11
00000–77FFF
SA10:SA0
Upper 1/16 (32 KB)
(6) SA12:SA7
00000–6FFFF
SA6:SA0
Upper 1/8 (64 KB)
60000–7FFFF
(7) SA12:SA6
00000–5FFFF
SA5:SA0
Upper 1/4 (128 KB)
40000–7FFFF
(9) SA12:SA4
00000–3FFFF
SA3:SA0
Upper 1/2 (256 KB)
0
00000–7FFFF
(13) SA12:SA0
None
None
All (512 KB)
1
00000–7FFFF
(13) SA12:SA0
None
None
All (512 KB)
BP2
BP1
BP0
0
0
0
None
0
0
1
7C000–7FFFF
0
1
0
78000–7FFFF
0
1
1
70000–7FFFF
1
0
0
1
0
1
1
1
1
1
Protected
Sectors
Protected Portion of
Total Memory Area
Table 7.2 S25FL040A Protected Area Sizes (Bottom Boot)
Status Register
Block Protect Bits
Memory Array
Protected
Address Range
Protected
Sectors
Unprotected
Address Range
Unprotected
Sectors
Protected Portion of
Total Memory Area
BP2
BP1
BP0
0
0
0
None
(0)
00000–7FFFF
SA12:SA0
0
0
0
1
00000–03FFF
(1) SA0
04000–7FFFF
SA12:SA1
Lower 1/32 (16 KB)
0
1
0
00000–07FFF
(2) SA1:SA0
08000–7FFFF
SA12:SA2
Lower 1/16 (32 KB)
0
1
1
00000–0FFFF
(6) SA5:SA0
10000–7FFFF
SA12:SA4
Lower 1/8 (64 KB)
1
0
0
00000–1FFFF
(7) SA6:SA0
20000–7FFFF
SA12:SA5
Lower 1/4 (128 KB)
1
0
1
00000–3FFFF
(9) SA8:SA0
40000–7FFFF
SA12:SA7
Lower 1/2 (256 KB)
1
1
0
00000–7FFFF
(13) SA12:SA0
None
None
All (512 KB)
1
1
1
00000–7FFFF
(13) SA12:SA0
None
None
All (512 KB)
February 27, 2009 S25FL040A_00_B4
S25FL040A
13
D at a
S hee t
Table 7.3 S25FL040A Protected Area Sizes (Uniform Sector)
Status Register
Block Protect Bits
7.7
Memory Array
BP2
BP1
BP0
Protected
Address Range
Protected
Sectors
Unprotected
Address Range
Unprotected
Sectors
Protected Portion of
Total Memory Area
0
0
0
None
(0)
00000–7FFFF
SA7:SA0
0
0
0
1
70000–7FFFF
(1) SA7
00000–6FFFF
SA6:SA0
Upper 1/8 (64 KB)
0
1
0
60000–7FFFF
(2) SA7:SA6
00000–5FFFF
SA5:SA0
Lower 1/4 (128 KB)
0
1
1
40000–7FFFF
(4) SA7:SA4
00000–3FFFF
SA3:SA0
Lower 1/2 (256 KB)
1
0
0
00000–7FFFF
(8) SA7:SA0
None
None
All (512 KB)
1
0
1
00000–7FFFF
(8) SA7:SA0
None
None
All (512 KB)
1
1
0
00000–7FFFF
(8) SA7:SA0
None
None
All (512 KB)
1
1
1
00000–7FFFF
(8) SA7:SA0
None
None
All (512 KB)
Hold Mode (HOLD#)
The Hold input (HOLD#) stops any serial communication with the device, but does not terminate any Write
Status Register, program or erase operation that is currently in progress.
The Hold mode starts on the falling edge of HOLD# if SCK is also low (see Figure 7.1 on page 14, standard
use). If the falling edge of HOLD# does not occur while SCK is low, the Hold mode begins after the next falling
edge of SCK (non-standard use).
The Hold mode ends on the rising edge of HOLD# signal (standard use) if SCK is also low. If the rising edge
of HOLD# does not occur while SCK is low, the Hold mode ends on the next falling edge of CLK (nonstandard use) See Figure 7.1.
The SO output is high impedance, and the SI and SCK inputs are ignored (don’t care) for the duration of the
Hold mode.
CS# must remain low for the entire duration of the Hold mode to ensure that the device internal logic remains
unchanged. If CS# goes high while the device is in the Hold mode, the internal logic is reset. To prevent the
device from reverting to the Hold mode when device communication is resumed, HOLD# must be held high,
followed by driving CS# low.
Figure 7.1 Hold Mode Operation
SCK
HOLD#
Hold
Condition
(standard use)
14
S25FL040A
Hold
Condition
(non-standard use)
S25FL040A_00_B4 February 27, 2009
Data
She et
8. Sector Address Table
Table 8.1 shows the size of the memory array, sectors, and pages. The device uses pages to cache the
program data before the data is programmed into the memory array. Each page or byte can be individually
programmed (bits are changed from 1 to 0). The data is erased (bits are changed from 0 to 1) on a sector- or
device-wide basis using the SE or BE commands. Table 8.4 shows the starting and ending address for each
sector. The complete set of sectors comprises the memory array of the Flash device.
Table 8.1 S25FL040A Device Organization
Each Device has
Each Sector has
Each Page has
524,288
65,536 (64 KB sector)
16,384 (16 KB sector)
12,288 (12 KB sector)
4,096 (4 KB sector)
256
bytes
2,048
256 (64 KB sector)
64 (16 KB sector)
48 (12 KB sector)
16 (4 KB sector)
—
pages
12 (boot), 7 (uniform)
—
—
sectors
Table 8.2 S25FL040A Sector Address Table (Top Boot)
Sector
Size
SA12
16K Byte
7C000h
Address Range
7FFFFh
SA11
16K Byte
78000h
7BFFFh
SA10
4K Byte
77000h
77FFFh
SA9
4K Byte
76000h
76FFFh
SA8
12K Byte
73000h
75FFFh
SA7
12K Byte
70000h
72FFFh
SA6
64K Byte
60000h
6FFFFh
SA5
64K Byte
50000h
5FFFFh
SA4
64K Byte
40000h
4FFFFh
SA3
64K Byte
30000h
3FFFFh
SA2
64K Byte
20000h
2FFFFh
SA1
64K Byte
10000h
1FFFFh
SA0
64K Byte
00000h
0FFFFh
Table 8.3 S25FL040A Sector Address Table (Bottom Boot)
Sector
Size
SA12
64K Byte
70000h
7FFFFh
SA11
64K Byte
60000h
6FFFFh
SA10
64K Byte
50000h
5FFFFh
SA9
64K Byte
40000h
4FFFFh
SA8
64K Byte
30000h
3FFFFh
SA7
64K Byte
20000h
2FFFFh
SA6
64K Byte
10000h
1FFFFh
SA5
12K Byte
0D000h
0FFFFh
SA4
12K Byte
0A000h
0CFFFh
SA3
4K Byte
09000h
09FFFh
SA2
4K Byte
08000h
08FFFh
SA1
16K Byte
04000h
07FFFh
SA0
16K Byte
00000h
03FFFh
February 27, 2009 S25FL040A_00_B4
S25FL040A
Address Range
15
D at a
S hee t
Table 8.4 S25FL040A Sector Address Table (Uniform Sectors)
Sector
Address Range
SA7
070000h
07FFFFh
SA6
060000h
06FFFFh
SA5
050000h
05FFFFh
SA4
040000h
04FFFFh
SA3
030000h
03FFFFh
SA2
020000h
02FFFFh
SA1
010000h
01FFFFh
SA0
000000h
00FFFFh
9. Command Definitions
The host system must shift all commands, addresses, and data in and out of the device, beginning with the
most significant bit. On the first rising edge of SCK after CS# is driven low, the device accepts the one-byte
command on SI (all commands are one byte long), most significant bit first. Each successive bit is latched on
the rising edge of SCK. Table 9.5 on page 29 lists the complete set of commands.
Every command sequence begins with a one-byte command code. The command may be followed by
address, data, both, or nothing, depending on the command. CS# must be driven high after the last bit of the
command sequence has been written.
The Read Data Bytes (READ), Read Status Register (RDSR), Read Data Bytes at Higher Speed
(FAST_READ) and Read Identification (RDID) command sequences are followed by a data output sequence
on SO. CS# can be driven high after any bit of the sequence is output to terminate the operation.
The Page Program (PP), Sector Erase (SE), Bulk Erase (BE), Write Status Register (WRSR), Write Enable
(WREN), or Write Disable (WRDI) commands require that CS# be driven high at a byte boundary, otherwise
the command is not executed. Since a byte is composed of eight bits, CS# must therefore be driven high
when the number of clock pulses after CS# is driven low is an exact multiple of eight.
The device ignores any attempt to access the memory array during a Write Status Register, program, or
erase operation, and continues the operation uninterrupted.
9.1
Read Data Bytes (READ)
The Read Data Bytes (READ) command reads data from the memory array at the frequency (fSCK) presented
at the SCK input, with a maximum speed of 33 MHz. The host system must first select the device by driving
CS# low. The READ command is then written to SI, followed by a 3-byte address (A23-A0). Each bit is
latched on the rising edge of SCK. The memory array data, at that address, are output serially on SO at a
frequency fSCK, on the falling edge of SCK.
Figure 9.1 and Table 9.5 detail the READ command sequence. The first byte specified can be at any location.
The device automatically increments to the next higher address after each byte of data is output. The entire
memory array can therefore be read with a single READ command. When the highest address is reached, the
address counter reverts to 00000h, allowing the read sequence to continue indefinitely.
The READ command is terminated by driving CS# high at any time during data output. The device rejects any
READ command issued while it is executing a program, erase, or Write Status Register operation, and
continues the operation uninterrupted.
16
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
She et
Figure 9.1 Read Data Bytes (READ) Command Sequence
CS#
0
Mode 3
SCK
1
2 3
4
5
6
7
8
28 29 30 31 32 33 34 35 36 37 38 39
9 10
Mode 0
Command
24-Bit Address
3 2 1 0
23 22 21
SI
MSB
Data Out 1
Hi-Z
SO
Data Out 2
7 6 5 4 3 2
1 0 7
MSB
9.2
Read Data Bytes at Higher Speed (FAST_READ)
The FAST_READ command reads data from the memory array at the frequency (fSCK) presented at the SCK
input, with a maximum speed of 50 MHz. The host system must first select the device by driving CS# low. The
FAST_READ command is then written to SI, followed by a 3-byte address (A23-A0) and a dummy byte. Each
bit is latched on the rising edge of SCK. The memory array data, at that address, are output serially on SO at
a frequency fSCK, on the falling edge of SCK.
The FAST_READ command sequence is shown in Figure 9.2 and Table 9.5. The first byte specified can be
at any location. The device automatically increments to the next higher address after each byte of data is
output. The entire memory array can therefore be read with a single FAST_READ command. When the
highest address is reached, the address counter reverts to 00000h, allowing the read sequence to continue
indefinitely.
The FAST_READ command is terminated by driving CS# high at any time during data output. The device
rejects any FAST_READ command issued while it is executing a program, erase, or Write Status Register
operation, and continues the operation uninterrupted.
Figure 9.2 Read Data Bytes at Higher Speed (FAST_READ) Command Sequence
CS#
Mode 3
SCK
0
1
2
3
4
5
Command
7
8
9
10
28 29 30
31 32 33
24-Bit Address
23 22 21
SI
SO
6
34 35 36 37 38
39
40 41
42 43 44 45
46
47
Mode 0
3
2
Hi-Z
Dummy Byte
1
0
7
6
5
4
3
2
1
0
7
MSB
February 27, 2009 S25FL040A_00_B4
S25FL040A
6
5
4
3
DATA OUT 1
2
1
0
7
MSB
DATA OUT 2
17
D at a
9.3
S hee t
Read Identification (RDID)
The Read Identification (RDID) command outputs the one-byte manufacturer identification, followed by the
two-byte device identification, to the host system.
JEDEC assigns the manufacturer identification byte; for Spansion devices it is 01h. The device manufacturer
assigns the device identification: the first byte provides the memory type; the second byte indicates the
memory capacity. See Table 9.1 or Table 9.5 for device ID data.
The host system must first select the device by driving CS# low. The RDID command is then written to SI,
and each bit is latched on the rising edge of SCK. The 24-bit device identification data is output from the
memory array on SO at a frequency fSCK, on the falling edge of SCK.
The RDID command sequence is shown in Figure 9.3 and Table 9.5.
Driving CS# high after the device identification data has been read at least once terminates the READ_ID
command. Driving CS# high at any time during data output also terminates the RDID operation.
The device rejects any RDID command issued while it is executing a program, erase, or Write Status Register
operation, and continues the operation uninterrupted.
Figure 9.3 Read Identification (RDID) Command Sequence and Data-Out Sequence
CS#
SCK
Mode 3
0
1
2
3
4
5
6
7
8
9
10
11 12
13
14 15 16
17 18
28 29 30 31
Mode 0
Command
SI
Manufacturer Identification
SO
Hi-Z
Device Identification
15 14 13
3
2
1
0
MSB
Table 9.1 RDID Data
Device
Sector Type
S25FL040A
Top Boot
Memory Type
(2nd Byte)
02h
12h
01h
02h
25h
02h
26h
Uniform
Bottom Boot
18
S25FL040A
Device Identification
Manufacturer
Information
(1st Byte)
Memory Capacity
(3rd Byte)
S25FL040A_00_B4 February 27, 2009
Data
9.4
She et
Read Identification (Read_ID) [RDID Alternate]
The READ_ID instruction provides the S25FL040A manufacturer and device information. This command
should be used as default device identification when multiple versions of SPI Serial Flash devices are used in
a design.
The device information can be read from by writing the 8-bit command (90H) followed by address bits.
Following the READ_ID instruction, the manufacturer’s ID is located at address 00000H and the device ID
(Memory Capacity) is located at address 00001H. Once the device is in READ_ID mode, the manufacturer’s
and device ID output data toggles between address 00000H and 00001H until CE# is driven high.
Figure 9.4 READ_ID Command Timing Diagram
CS#
0
1
2
3
4
5
6
7
8
9
10
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
SCK
Instruction
SI
24-Bit Address
23 22 21
3
2
1
0
MSB
Manufacture Identification
Device Identification
High Impedance
7
SO
6
5
4
3
2
1
0
Table 9.2 READ_ID Data-Out Sequence
Data
Address
Uniform
Top Boot
Bottom Boot
Manufacturer Identification
00000h
01h
01h
01h
Device Identification (Memory Capacity)
00001h
12h
25h
26h
February 27, 2009 S25FL040A_00_B4
S25FL040A
19
D at a
9.5
S hee t
Write Enable (WREN)
The Write Enable (WREN) command (see Figure 9.5) sets the Write Enable Latch (WEL) bit to a 1, which
enables the device to accept a Write Status Register, program, or erase command. The WEL bit must be set
prior to every Page Program (PP), Erase (SE or BE) and Write Status Register (WRSR) command.
The host system must first drive CS# low, write the WREN command, and then drive CS# high.
Figure 9.5 Write Enable (WREN) Command Sequence
CS#
Mode 3
SCK
0 1
2 3
4 5 6 7
Mode 0
Command
SI
Hi-Z
SO
9.6
Write Disable (WRDI)
The Write Disable (WRDI) command (see Figure 9.6) resets the Write Enable Latch (WEL) bit to a 0, which
disables the device from accepting a Write Status Register, program, or erase command. The host system
must first drive CS# low, write the WRDI command, and then drive CS# high.
Any of following conditions resets the WEL bit:
„ Power-up
„ Write Disable (WRDI) command completion
„ Write Status Register (WRSR) command completion
„ Page Program (PP) command completion
„ Sector Erase (SE) command completion
„ Bulk Erase (BE) command completion
Figure 9.6 Write Disable (WRDI) Command Sequence
CS#
Mode 3
0 1 2 3 4 5 6 7
SCK Mode 0
Command
SI
Hi-Z
SO
20
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
9.7
She et
Read Status Register (RDSR)
The Read Status Register (RDSR) command outputs the state of the Status Register bits. Table 9.3 shows
the status register bits and their functions.
The RDSR command may be written at any time, even while a program, erase, or Write Status Register
operation is in progress. The host system should check the Write In Progress (WIP) bit before sending a new
command to the device if an operation is already in progress. Figure 9.7 shows the RDSR command
sequence, which also shows that it is possible to read the Status Register continuously until CS# is driven
high.
Table 9.3 S25FL040A Status Register
Bit
Status Register Bit
Bit Function
7
SRWD
Status Register Write Disable
6
—
—
Not used
5
—
—
Not used
4
BP2
3
BP1
2
BP0
1
WEL
Block Protect
Write Enable Latch
Description
1 = Protects when W# is low
0 = No protection, even when W# is low
000–111 = Protects upper half of address range in 5 sizes. See
Table 7.1.
1 = Device accepts Write Status Register, program, or erase
commands
0 = Ignores Write Status Register, program, or erase commands
0
WIP
Write in Progress
1 = Device Busy. A Write Status Register, program, or erase
operation is in progress
0 = Ready. Device is in standby mode and can accept commands.
Figure 9.7 Read Status Register (RDSR) Command Sequence
CS#
Mode 3
SCK
0 1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
Mode 0
Command
SI
SO
Hi-Z
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7
MSB
Status Register Out
MSB
Status Register Out
The following describes the status and control bits of the Status Register.
Write In Progress (WIP) bit: Indicates whether the device is busy performing a Write Status Register,
program, or erase operation. This bit is read-only, and is controlled internally by the device. If WIP is 1, one of
these operations is in progress; if WIP is 0, no such operation is in progress.
Write Enable Latch (WEL) bit: Determines whether the device will accept and execute a Write Status
Register, program, or erase command. When set to 1, the device accepts these commands; when set to 0,
the device rejects the commands. This bit is set to 1 by writing the WREN command, and set to 0 by the
WRDI command, and is also automatically reset to 0 after the completion of a Write Status Register, program,
or erase operation. WEL cannot be directly set by the WRSR command.
Block Protect (BP2, BP1, BP0) bits: Define the portion of the memory area that will be protected against
any changes to the stored data. The Write Status Register (WRSR) command controls these bits, which are
non-volatile. When one or more of these bits is set to 1, the corresponding memory area (see Table 7.1
February 27, 2009 S25FL040A_00_B4
S25FL040A
21
D at a
S hee t
on page 13) is protected against Page Program (PP) and Sector Erase (SE) commands. If the Hardware
Protected mode is enabled, BP2:BP0 cannot be changed. The Bulk Erase (BE) command is executed only if
all Block Protect (BP2, BP1, BP0) bits are 0.
Status Register Write Disable (SRWD) bit: Provides data protection when used together with the Write
Protect (W#) signal. When SRWD is set to 1 and W# is driven low, the device enters the Hardware Protected
mode. The non-volatile bits of the Status Register (SRWD, BP2, BP1, BP0) become read-only bits and the
device ignores any Write Status Register (WRSR) command.
9.8
Write Status Register (WRSR)
The Write Status Register (WRSR) command changes the bits in the Status Register. A Write Enable
(WREN) command, which itself sets the Write Enable Latch (WEL) in the Status Register, is required prior to
writing the WRSR command. Table 9.3 on page 21 shows the status register bits and their functions.
The host system must drive CS# low, write the WRSR command, and the appropriate data byte on SI
(Figure 9.8).
The WRSR command cannot change the state of the Write Enable Latch (bit 1). The WREN command must
be used for that purpose. Bit 0 is a status bit controlled internally by the Flash device. Bits 6 and 5 are always
read as 0 and have no user significance.
The WRSR command also controls the value of the Status Register Write Disable (SRWD) bit. The SRWD bit
and W# together place the device in the Hardware Protected Mode (HPM). The device ignores all WRSR
commands once it enters the Hardware Protected Mode (HPM). Table 9.4 shows that W# must be driven low
and the SRWD bit must be 1 for this to occur.
Figure 9.8 Write Status Register (WRSR) Command Sequence
CS#
Mode 3
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
SCK Mode 0
Command
Status Register In
7
SI
6
5
4
3
2
1
0
MSB
SO
Hi-Z
Table 9.4 Protection Modes
W#
Signal
SRWD
Bit
1
1
1
0
0
0
0
1
Protected Area
(See Note)
Unprotected Area
(See Note)
Status Register is writable (if the WREN
command has set the WEL bit). The values in
the SRWD, BP2, BP1 and BP0 bits can be
changed.
Protected against program
and erase commands
Ready to accept Page
Program and Sector Erase
commands
Status Register is Hardware write protected.
The values in the SRWD, BP2, BP1 and BP0
bits cannot be changed.
Protected against program
and erase commands
Ready to accept Page
Program and Sector Erase
commands
Mode
Write Protection of the Status Register
Software
Protected
(SPM)
Hardware
Protected
(HPM)
Note
As defined by the values in the Block Protect (BP2, BP1, BP0) bits of the Status Register, as shown in Table 7.1 on page 13.
Table 9.4 shows that neither W# or SRWD bit by themselves can enable HPM. The device can enter HPM
either by setting the SRWD bit after driving W# low, or by driving W# low after setting the SRWD bit.
However, the device disables HPM only when W# is driven high.
22
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
She et
Note that HPM only protects against changes to the status register. Since BP2:BP0 cannot be changed in
HPM, the size of the protected area of the memory array cannot be changed. Note that HPM provides no
protection to the memory array area outside that specified by BP2:BP0 (Software Protected Mode, or SPM).
If W# is permanently tied high, HPM can never be activated, and only the SPM (BP2:BP0 bits of the Status
Register) can be used.
9.9
Page Program (PP)
The Page Program (PP) command changes specified bytes in the memory array (from 1 to 0 only). A WREN
command is required prior to writing the PP command.
The host system must drive CS# low, and then write the PP command, three address bytes, and at least one
data byte on SI. CS# must be driven low for the entire duration of the PP sequence. The command sequence
is shown in Figure 9.9 and Table 9.5.
The device programs only the last 256 data bytes sent to the device. If the number of data bytes exceeds this
limit, the bytes sent before the last 256 bytes are discarded, and the device begins programming the last 256
bytes sent at the starting address of the specified page. This may result in data being programmed into
different addresses within the same page than expected. If fewer than 256 data bytes are sent to device, they
are correctly programmed at the requested addresses.
The host system must drive CS# high after the device has latched the 8th bit of the data byte, otherwise the
device does not execute the PP command. The PP operation begins as soon as CS# is driven high. The
device internally controls the timing of the operation, which requires a period of tPP. The Status Register may
be read to check the value of the Write In Progress (WIP) bit while the PP operation is in progress. The WIP
bit is 1 during the PP operation, and is 0 when the operation is completed. The device internally resets the
Write Enable Latch to 0 before the operation completes (the exact timing is not specified).
The device does not execute a Page Program (PP) command that specifies a page that is protected by the
Block Protect bits (BP2:BP0) (see Table 7.1 on page 13).
Figure 9.9 Page Program (PP) Command Sequence
CS#
0
Mode 3
5
4
3
6
8
7
28 29 30 31 32 33 34 35 36 37 38
9 10
39
Mode 0
24-Bit Address
3
23 22 21
2
1
0
MSB
6
5
4
3
2
1
0
2078
2079
2076
55
2077
51 52 53 54
2072
MSB
CS#
40 41 42 43 44 45 46 47 48 49 50
7
2075
SI
Data Byte 1
2074
Command
2073
SCK
2
1
SCK
Data Byte 2
SI
7
MSB
February 27, 2009 S25FL040A_00_B4
6
5
4
3
2
Data Byte 3
1
0
7
6
5
4
MSB
S25FL040A
3
2
Data Byte 256
1
0
7
6
5
4
3
2
1
0
MSB
23
D at a
9.10
S hee t
Sector Erase (SE)
The Sector Erase (SE) command sets all bits at all addresses within a specified sector to a logic 1. A WREN
command is required prior to writing the PP command.
The host system must drive CS# low, and then write the SE command plus three address bytes on SI. Any
address within the sector (see Table 7.1 on page 13) is a valid address for the SE command. CS# must be
driven low for the entire duration of the SE sequence. The command sequence is shown in Figure 9.10 and
Table 9.5.
The host system must drive CS# high after the device has latched the 8th bit of the SE command, otherwise
the device does not execute the command. The SE operation begins as soon as CS# is driven high. The
device internally controls the timing of the operation, which requires a period of tSE. The Status Register may
be read to check the value of the Write In Progress (WIP) bit while the SE operation is in progress. The WIP
bit is 1 during the SE operation, and is 0 when the operation is completed. The device internally resets the
Write Enable Latch to 0 before the operation completes (the exact timing is not specified).
The device does not execute an SE command that specifies a sector that is protected by the Block Protect
bits (BP2:BP0) (see Table 7.1 on page 13).
Figure 9.10 Sector Erase (SE) Command Sequence
CS#
Mode 3
SCK
0
1
2
3
4
5
6
7
8
9
10
28
29
30
31
1
0
Mode 0
Command
SI
24-bit Address
23
22
21
3
2
MSB
SO
24
Hi-Z
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
9.11
She et
Bulk Erase (BE)
The Bulk Erase (BE) command sets all the bits within the entire memory array to logic 1s. A WREN command
is required prior to writing the PP command.
The host system must drive CS# low, and then write the BE command on SI. CS# must be driven low for the
entire duration of the BE sequence. The command sequence is shown in Figure 9.11 and Table 9.5.
The host system must drive CS# high after the device has latched the 8th bit of the CE command, otherwise
the device does not execute the command. The BE operation begins as soon as CS# is driven high. The
device internally controls the timing of the operation, which requires a period of tBE. The Status Register may
be read to check the value of the Write In Progress (WIP) bit while the BE operation is in progress. The WIP
bit is 1 during the BE operation, and is 0 when the operation is completed. The device internally resets the
Write Enable Latch to 0 before the operation completes (the exact timing is not specified).
The device only executes a BE command if all Block Protect bits (BP2:BP0) are 0 (see Table 7.1
on page 13). Otherwise, the device ignores the command.
Figure 9.11 Bulk Erase (BE) Command Sequence
CS#
Mode 3
SCK
0
1
2
3
4
5
6
7
Mode 0
Command
SI
SO
February 27, 2009 S25FL040A_00_B4
Hi-Z
S25FL040A
25
D at a
9.12
S hee t
Deep Power Down (DP)
The Deep Power Down (DP) command provides the lowest power consumption mode of the device. It is
intended for periods when the device is not in active use, and ignores all commands except for the Release
from Deep Power Down (RES) command. The DP mode therefore provides the maximum data protection
against unintended write operations. The standard standby mode, which the device goes into automatically
when CS# is high (and all operations in progress are complete), should generally be used for the lowest
power consumption when the quickest return to device activity is required.
The host system must drive CS# low, and then write the DP command on SI. CS# must be driven low for the
entire duration of the DP sequence. The command sequence is shown in Figure 9.12 and Table 9.5.
The host system must drive CS# high after the device has latched the 8th bit of the DP command, otherwise
the device does not execute the command. After a delay of tDP, the device enters the DP mode and current
reduces from ISB to IDP (see Table 14.1 on page 32).
Once the device has entered the DP mode, all commands are ignored except the RES command (which
releases the device from the DP mode). The RES command also provides the Electronic Signature of the
device to be output on SO, if desired (see sections 9.13 and 9.13.1).
DP mode automatically terminates when power is removed, and the device always powers up in the standard
standby mode. The device rejects any DP command issued while it is executing a program, erase, or Write
Status Register operation, and continues the operation uninterrupted.
Figure 9.12 Deep Power Down (DP) Command Sequence
CS#
tDP
Mode 3
SCK
0
1
2
3
4
5
6
7
Mode 0
Command
SI
SO
Hi-Z
Standby Mode
26
S25FL040A
Deep Power-down Mode
S25FL040A_00_B4 February 27, 2009
Data
9.13
She et
Release from Deep Power Down (RES)
The device requires the Release from Deep Power Down (RES) command to exit the Deep Power Down
mode. When the device is in the Deep Power Down mode, all commands except RES are ignored.
The host system must drive CS# low and write the RES command to SI. CS# must be driven low for the entire
duration of the sequence. The command sequence is shown in Figure 9.13 and Table 9.5.
The host system must drive CS# high tRES(max) after the 8-bit RES command byte. The device transitions
from DP mode to the standby mode after a delay of tRES (see Table 16.1 on page 33). In the standby mode,
the device can execute any read or write command.
Figure 9.13 Release from Deep Power Down (RES) Command Sequence
CS#
Mode 3
SCK
0
1
2
3
4
5
6
7
Mode 0
Command
tRES
SI
SO
Hi-Z
Deep Power-down Mode
February 27, 2009 S25FL040A_00_B4
S25FL040A
Standby Mode
27
D at a
9.13.1
S hee t
Release from Deep Power Down and Read Electronic Signature (RES)
The device features an 8-bit Electronic Signature, which can be read using the RES command. See
Figure 9.14 and Table 9.5 for the command sequence and signature value. The Electronic Signature is not to
be confused with the identification data obtained using the RDID command. The device offers the Electronic
Signature so that it can be used with previous devices that offered it; however, the Electronic Signature
should not be used for new designs, which should read the RDID data instead.
After the host system drives CS# low, it must write the RES command followed by 3 dummy bytes to SI (each
bit is latched on SI during the rising edge of SCK). The Electronic Signature is then output on SO; each bit is
shifted out on the falling edge of SCK. The RES operation is terminated by driving CS# high after the
Electronic Signature is read at least once. Additional clock cycles on SCK with CS# low cause the device to
output the Electronic Signature repeatedly.
When CS# is driven high, the device transitions from DP mode to the standby mode after a delay of tRES, as
previously described. The RES command always provides access to the Electronic Signature of the device
and can be applied even if DP mode has not been entered.
Any RES command issued while an erase, program, or WRSR operation is in progress not executed, and the
operation continues uninterrupted.
Figure 9.14 Release from Deep Power Down and
Read Electronic Signature (RES) Command Sequence
CS#
0
1
2
3
4
5
6
7
8
9
10
28 29 30 31 32 33 34 35 36 37 38
SCK
SI
tRES
3 Dummy Bytes
Command
23 22 21
3
2
1
0
MSB
SO
Hi-Z
7
6
MSB
Deep Power-down Mode
28
S25FL040A
5
4
3
2
1
0
Electronic ID out
Standby Mode
S25FL040A_00_B4 February 27, 2009
Data
9.14
She et
Command Definitions
Table 9.5 Command Definitions
Operation
Command
READ
FAST_READ
Read
RDID
One-Byte
Command Code
Address
Bytes
Dummy
Byte
Read Data Bytes
03H (0000 0011)
3
0
1 to ∞
Read Data Bytes at Higher Speed
0BH (0000 1011)
3
1
1 to ∞
Description
Data Bytes
Read Identification (Note 1)
9FH (1001 1111)
0
0
1 to 3
Read Manufacture and
Device Identification (Note 1)
90H (1001 0000)
3
0
1 to ∞
WREN
Write Enable
06H (0000 0110)
0
0
0
WRDI
Write Disable
04H (0000 0100)
0
0
0
SE
Sector Erase
D8H (1101 1000)
3
0
0
BE
Bulk (Chip) Erase
C7H (1100 0111)
0
0
0
Program
PP
Page Program
02H (0000 0010)
3
0
1 to 256
Status
Register
RDSR
Read from Status Register
05H (0000 0101)
0
0
1 to ∞
WRSR
Write to Status Register
01H (0000 0001)
0
0
1
Deep Power Down
B9H (1011 1001)
0
0
0
Release from Deep Power Down
ABH (1010 1011)
0
0
0
Release from Deep Power Down and
Read Electronic Signature (Note 2)
ABH (1010 1011)
0
3
1 to ∞
READ_ID
Write
Control
Erase
DP
Power
Saving
RES
Notes
1. The S25FL040A has a manufacturer ID of 01h, and a device ID consisting of the memory type (02h) and the memory capacity (12h for
uniform sector, 25h for top boot, 26h for bottom boot).
2. The S25FL040A has an Electronic Signature ID of 12h.
February 27, 2009 S25FL040A_00_B4
S25FL040A
29
D at a
S hee t
10. Power-up and Power-down
During power-up and power-down, certain conditions must be observed. CS# must follow the voltage applied
on VCC, and must not be driven low to select the device until VCC reaches the allowable values as follows
(see Figure 10.1 and Table 10.1):
„ At power-up, VCC (min) plus a period of tPU
„ At power-down, VSS
A pull-up resistor on Chip Select (CS#) typically meets proper power-up and power-down requirements.
No Write Status Register, program, or erase command should be sent to the device until VCC rises to the VCC
min, plus a delay of tPU. At power-up, the device is in standby mode (not Deep Power Down mode) and the
WEL bit is reset (0).
Each device in the host system should have the VCC rail decoupled by a suitable capacitor close to the
package pins (this capacitor is generally of the order of 0.1 µF), as a precaution to stabilizing the VCC feed.
When VCC drops from the operating voltage to below the minimum VCC threshold at power-down, all
operations are disabled and the device does not respond to any commands. Note that data corruption may
result if a power-down occurs while a Write Register, program, or erase operation is in progress.
Figure 10.1 Power-Up Timing Diagram
Vcc
(max)
Vcc
(min)
Vcc
t PU
Full Device Access
Time
Table 10.1 Power-Up Timing Characteristics
Symbol
Parameter
Min
Max
Unit
VCC(min)
VCC (minimum)
2.7
V
tPU
VCC (min) to device operation
10
ms
11. Initial Delivery State
The device is delivered with all bits set to 1 (each byte contains FFh) upon initial factory shipment. The Status
Register contains 00h (all Status Register bits are 0).
30
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
She et
12. Absolute Maximum Ratings
Do not stress the device beyond the ratings listed in this section, or serious, permanent damage to the device
may result. These are stress ratings only and device operation at these or any other conditions beyond those
indicated in this section and in the Operating Ranges section of this document is not implied. Device
operation for extended periods at the limits listed in this section may affect device reliability.
Table 12.1 Absolute Maximum Ratings
Description
Rating
Ambient Storage Temperature
–65°C to +150°C
–0.5 V to VCC+0.5 V
Voltage with Respect to Ground: All Inputs and I/Os
Notes
1. Minimum DC voltage on input or I/O pins is –0.5 V. During voltage transitions, input at I/O pins may overshoot VSS to –2.0 V for periods of
up to 20 ns. See Figure 12.2. Maximum DC voltage on output and I/O pins is 3.6 V. During voltage transitions output pins may overshoot
to VCC + 2.0 V for periods up to 20 ns. See Figure 12.2.
2. No more than one output may be shorted to ground at a time. Duration of the short circuit should not be greater than one second.
3. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only;
functional operation of the device at these or any other conditions above those indicated in the operational sections of this data sheet is not
implied. Exposure of the device to absolute maximum rating conditions for extended periods may affect device reliability.
Figure 12.1 Maximum Negative Overshoot Waveform
20 ns
20 ns
+0.8 V
–0.5 V
–2 V
20 ns
Figure 12.2 Maximum Positive Overshoot Waveform
20 ns
V CC +2.0 V
V CC +0.5 V
2.0 V
20 ns
20 ns
13. Operating Ranges
Table 13.1 Operating Ranges
Description
Rating
Commerical
Ambient Operating Temperature (TA)
Industrial
Positive Power Supply
Voltage Range
0°C to +70°C
–40°C to +85°C
2.7 V to 3.6 V
Note
Operating ranges define those limits between which functionality of the device is guaranteed.
February 27, 2009 S25FL040A_00_B4
S25FL040A
31
D at a
S hee t
14. DC Characteristics
This section summarizes the DC Characteristics of the device. Designers should check that the operating
conditions in their circuit match the measurement conditions specified in the Test Specifications in Table 15.1
on page 32, when relying on the quoted parameters.
Table 14.1 DC Characteristics (CMOS Compatible)
Parameter
VCC
Description
Test Conditions (See Note)
Supply Voltage
Min
Typ.
Max
Unit
2.7
3
3.6
V
9
mA
13
mA
SCK = 0.1 VCC/0.9VCC 33 MHz
ICC1
Active Read Current
SCK = 0.1 VCC/0.9VCC
VCC = 3.0V,
50 MHz
ICC2
Active Page Program Current CS# = VCC
22
mA
ICC3
Active WRSR Current
CS# = VCC
13.5
24
mA
ICC4
Active Sector Erase Current
CS# = VCC
24
mA
ICC5
Active Bulk Erase Current
CS# = VCC
24
mA
ISB
Standby Current
VCC = 3.0 V
CS# = VCC
20
50
µA
IDP
Deep Power Down Current
VCC = 3.0 V
CS# = VCC
1.5
5
µA
ILI
Input Leakage Current
VIN = GND to VCC
1
µA
ILO
Output Leakage Current
VIN = GND to VCC
1
µA
VIL
Input Low Voltage
–0.3
0.3 VCC
V
VIH
Input High Voltage
0.7 VCC
VCC + 0.5
V
VOL
Output Low Voltage
IOL = 1.6 mA, VCC = VCC min
0.4
V
VOH
Output High Voltage
IOH = –0.1 mA
VCC – 0.2
V
Note
Typical values are at TA = 25°C and 3.0 V.
15. Test Conditions
Figure 15.1 AC Measurements I/O Waveform
0.8 VCC
0.7 VCC
0.5 VCC
0.3 VCC
Input Levels
0.2 VCC
Input and Output
Table 15.1 Test Specifications
Symbol
Parameter
CL
Load Capacitance
Min
Max
30
Input Rise and Fall Times
32
Unit
pF
5
ns
Input Pulse Voltage
0.2 VCC to 0.8 VCC
V
Input Timing Reference Voltage
0.3 VCC to 0.7 VCC
V
Output Timing Reference Voltage
0.5 VCC
V
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
She et
16. AC Characteristics
Table 16.1 AC Characteristics
Symbol
(Notes)
Typ
(Notes)
Max
(Notes)
Unit
D.C.
33
MHz
D.C.
50
MHz
Parameter
Min
FSCK
SCK Clock Frequency READ command
FSCK
SCK Clock Frequency for:
FAST_READ, PP, SE, BE, DP, RES, WREN, WRDI, RDSR, WRSR
tCRT
Clock Rise Time (Slew Rate)
0.1
V/ns
tCFT
Clock Fall Time (Slew Rate)
0.1
V/ns
tWH
SCK High Time
9
ns
tWL
SCK Low Time
9
ns
tCS
CS# High Time
100
ns
tCSS (3)
CS# Setup Time
5
ns
tCSH (3)
CS# HOLD Time
5
ns
tHD (3)
HOLD# Setup Time (relative to SCK)
5
ns
tCD (3)
HOLD# Hold Time (relative to SCK)
5
ns
tHC
HOLD# Setup Time (relative to SCK)
5
ns
tCH
HOLD# Hold Time (relative to SCK)
5
ns
Output Valid
tV
9
tHO
Output Hold Time
0
tHD:DAT
Data in Hold Time
5
tSU:DAT
Data in Setup Time
5
10
ns
ns
ns
ns
tR
Input Rise Time
5
ns
tF
Input Fall Time
5
ns
tLZ (3)
HOLD# to Output Low Z
10
ns
tHZ (3)
HOLD# to Output High Z
10
ns
tDIS (3)
Output Disable Time
10
ns
tWPS (3)
Write Protect Setup Time
15
tWPH (3)
Write Protect Hold Time
15
tW
Write Status Register Time
ns
ns
67
150
ms
μs
tDP
CS# High to Deep Power Down Mode
3
tRES
Release DP Mode
30
μs
tPP
Page Programming Time
1.5 (1)
3 (2)
ms
tSE
Sector Erase Time
0.5 (1)
3 (2)
sec
tBE
Bulk Erase Time
3 (1)
24 (2)
sec
Notes
1. Typical program and erase times assume the following conditions: 25°C, VCC = 3.0V; 10,000 cycles; checkerboard data pattern
2. Under worst-case conditions of 90°C; VCC = 2.7V; 100,000 cycles
3. Not 100% tested
Figure 16.1 SPI Mode 0 (0,0) Input Timing
tCS
CS#
tCSH
tCSH
tCSS
tCSS
SCK
tSU:DAT tHD:DAT
tCRT
SI
MSB IN
SO
tCFT
LSB IN
Hi-Z
February 27, 2009 S25FL040A_00_B4
S25FL040A
33
D at a
S hee t
Figure 16.2 SPI Mode 0 (0,0) Output Timing
CS#
tWH
SCK
tV
tHO
tWL
tV
tDIS
tHO
SO
LSB OUT
Figure 16.3 HOLD# Timing
CS#
tCH
tHC
tHD
SCK
tCD
tHZ
tLZ
SO
SI
HOLD#
34
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
She et
Figure 16.4 Write Protect Setup and Hold Timing during WRSR when SRWD=1
W#
tWPS
tWPH
CS#
SCK
SI
SO
Hi-Z
February 27, 2009 S25FL040A_00_B4
S25FL040A
35
D at a
S hee t
17. Physical Dimensions
17.1
SOA 008—Narrow 8-pin Plastic Small Outline 150 mils Body Width Package
3
4
0.20 C
D
A
A-B
H
D
5
SEE
DETAIL B
WITH
PLATING
b1
9
3
c
4
c1
E
E1
E1/2
(b)
BASE
METAL
E/2
7
SECTION A-A
e
0.33 C
b
B
0.25 M C
5
A-B
q2
D
GAUGE
PLANE
A
0.10 C
A2
A
0.07 R MIN.
H
0.10 C
SEATING PLANE
A1
C
C
SEATING
PLANE
A
q1
L
q
L2
L1
DETAIL B
NOTES:
1.
PACKAGE
SOC 008 (inches)
SOC 008 (mm)
JEDEC
SYMBOL
MIN
MAX
MIN
MAX
A
0.069
0.085
1.753
2.159
A1
0.002
0.0098
0.051
0.249
A2
0.067
0.075
1.70
1.91
b
0.014
0.019
0.356
0.483
b1
0.013
0.018
0.330
0.457
c
0.0075
0.0095
0.191
0.241
c1
0.006
0.008
0.152
0.203
D
0.208 BSC
5.283 BSC
E
0.315 BSC
8.001 BSC
E1
0.208 BSC
5.283 BSC
e
L
.050 BSC
0.020
0.030
1.27 BSC
0.508
.055 REF
1.40 REF
L2
.010 BSC
0.25 BSC
N
8
0˚
8˚
0˚
8˚
θ1
5˚
15˚
5˚
15˚
0˚
DIMENSION D DOES NOT INCLUDE MOLD FLASH,
PROTRUSIONS OR GATE BURRS. MOLD FLASH,
PROTRUSIONS OR GATE BURRS SHALL NOT EXCEED 0.15 mm
PER END. DIMENSION E1 DOES NOT INCLUDE INTERLEAD
FLASH OR PROTRUSION INTERLEAD FLASH OR PROTRUSION
SHALL NOT EXCEED 0.25 mm PER SIDE. D AND E1
DIMENSIONS ARE DETERMINED AT DATUM H.
.
4.
THE PACKAGE TOP MAY BE SMALLER THAN THE PACKAGE
BOTTOM. DIMENSIONS D AND E1 ARE DETERMINED AT THE
OUTMOST EXTREMES OF THE PLASTIC BODY EXCLUSIVE OF
MOLD FLASH, TIE BAR BURRS, GATE BURRS AND INTERLEAD
FLASH. BUT INCLUDING ANY MISMATCH BETWEEN THE TOP
AND BOTTOM OF THE PLASTIC BODY.
5.
DATUMS A AND B TO BE DETERMINED AT DATUM H.
6.
"N" IS THE MAXIMUM NUMBER OF TERMINAL POSITIONS FOR
THE SPECIFIED PACKAGE LENGTH.
7.
THE DIMENSIONS APPLY TO THE FLAT SECTION OF THE LEAD
BETWEEN 0.10 TO 0.25 mm FROM THE LEAD TIP.
8.
DIMENSION "b" DOES NOT INCLUDE DAMBAR PROTRUSION.
ALLOWABLE DAMBAR PROTRUSION SHALL BE 0.10 mm TOTAL
IN EXCESS OF THE "b" DIMENSION AT MAXIMUM MATERIAL
CONDITION. THE DAMBAR CANNOT BE LOCATED ON THE
LOWER RADIUS OF THE LEAD FOOT.
9.
THIS CHAMFER FEATURE IS OPTIONAL. IF IT IS NOT PRESENT,
THEN A PIN 1 IDENTIFIER MUST BE LOCATED WITHIN THE INDEX
AREA INDICATED.
8
θ
θ2
DIMENSIONING AND TOLERANCING PER ASME Y14.5M - 1994.
3.
0.762
L1
ALL DIMENSIONS ARE IN BOTH INCHES AND MILLMETERS.
2.
0˚
10. LEAD COPLANARITY SHALL BE WITHIN 0.10 mm AS MEASURED
FROM THE SEATING PLANE.
3432 \ 16-038.03 \ 10.28.04
36
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
17.2
She et
SOC 008—Wide 8-pin Plastic Small Outline 208 mils Body Width Package
3
4
0.20 C
D
A
A-B
H
D
5
SEE
DETAIL B
WITH
PLATING
b1
9
3
c
4
c1
E
E1
E1/2
(b)
BASE
METAL
E/2
7
SECTION A-A
e
0.33 C
b
B
0.25 M C
5
A-B
q2
D
GAUGE
PLANE
A
0.10 C
A2
A
0.07 R MIN.
H
0.10 C
SEATING PLANE
A1
C
C
SEATING
PLANE
A
q1
L
q
L2
L1
DETAIL B
NOTES:
1.
PACKAGE
SOC 008 (inches)
SOC 008 (mm)
JEDEC
SYMBOL
MIN
MAX
MIN
MAX
A
0.069
0.085
1.753
2.159
A1
0.002
0.0098
0.051
0.249
A2
0.067
0.075
1.70
1.91
b
0.014
0.019
0.356
0.483
b1
0.013
0.018
0.330
0.457
c
0.0075
0.0095
0.191
0.241
c1
0.006
0.008
0.152
0.203
D
0.208 BSC
5.283 BSC
E
0.315 BSC
8.001 BSC
E1
0.208 BSC
5.283 BSC
e
L
.050 BSC
0.020
0.030
1.27 BSC
0.508
.055 REF
1.40 REF
L2
.010 BSC
0.25 BSC
N
8
DIMENSION D DOES NOT INCLUDE MOLD FLASH,
PROTRUSIONS OR GATE BURRS. MOLD FLASH,
PROTRUSIONS OR GATE BURRS SHALL NOT EXCEED 0.15 mm
PER END. DIMENSION E1 DOES NOT INCLUDE INTERLEAD
FLASH OR PROTRUSION INTERLEAD FLASH OR PROTRUSION
SHALL NOT EXCEED 0.25 mm PER SIDE. D AND E1
DIMENSIONS ARE DETERMINED AT DATUM H.
.
4.
THE PACKAGE TOP MAY BE SMALLER THAN THE PACKAGE
BOTTOM. DIMENSIONS D AND E1 ARE DETERMINED AT THE
OUTMOST EXTREMES OF THE PLASTIC BODY EXCLUSIVE OF
MOLD FLASH, TIE BAR BURRS, GATE BURRS AND INTERLEAD
FLASH. BUT INCLUDING ANY MISMATCH BETWEEN THE TOP
AND BOTTOM OF THE PLASTIC BODY.
5.
DATUMS A AND B TO BE DETERMINED AT DATUM H.
6.
"N" IS THE MAXIMUM NUMBER OF TERMINAL POSITIONS FOR
THE SPECIFIED PACKAGE LENGTH.
7.
THE DIMENSIONS APPLY TO THE FLAT SECTION OF THE LEAD
BETWEEN 0.10 TO 0.25 mm FROM THE LEAD TIP.
8.
DIMENSION "b" DOES NOT INCLUDE DAMBAR PROTRUSION.
ALLOWABLE DAMBAR PROTRUSION SHALL BE 0.10 mm TOTAL
IN EXCESS OF THE "b" DIMENSION AT MAXIMUM MATERIAL
CONDITION. THE DAMBAR CANNOT BE LOCATED ON THE
LOWER RADIUS OF THE LEAD FOOT.
9.
THIS CHAMFER FEATURE IS OPTIONAL. IF IT IS NOT PRESENT,
THEN A PIN 1 IDENTIFIER MUST BE LOCATED WITHIN THE INDEX
AREA INDICATED.
8
θ
0˚
8˚
0˚
8˚
θ1
5˚
15˚
5˚
15˚
θ2
DIMENSIONING AND TOLERANCING PER ASME Y14.5M - 1994.
3.
0.762
L1
0˚
ALL DIMENSIONS ARE IN BOTH INCHES AND MILLMETERS.
2.
0˚
10. LEAD COPLANARITY SHALL BE WITHIN 0.10 mm AS MEASURED
FROM THE SEATING PLANE.
3432 \ 16-038.03 \ 10.28.04
February 27, 2009 S25FL040A_00_B4
S25FL040A
37
D at a
17.3
S hee t
USON 8L (5 x 6 mm) No-Lead Package
QUAD FLAT NO LEAD PACKAGES (UNE) - PLASTIC
1. DIMENSIONING AND TOLERANCING CONFORMS TO
ASME Y14.5M-1994.
DIMENSIONS
SYMBOL
MIN
NOM
NOTES:
MAX
NOTE
e
1.27 BSC
N
8
3
ND
4
5
2. ALL DIMENSIONS ARE IN MILLIMETERS, 0 IS IN DEGREES.
3. N IS THE TOTAL NUMBER OF TERMINALS.
4. DIMENSION b APPLIES TO METALLIZED TERMINAL AND IS
MEASURED BETWEEN 0.15 AND 0.30 mm FROM TERMINAL TIP.
IF THE TERMINAL HAS THE OPTIONAL RADIUS ON THE OTHER
END OF THE TERMINAL, THE DIMENSION b SHOULD NOT BE
MEASURED IN THAT RADIUS AREA.
L
0.55
0.60
0.65
b
0.35
0.40
0.45
D2
3.90
4.00
4.10
5.
ND REFERS TOT HE NUMBER OF TERMINALS ON D SIDE.
E2
3.30
3.40
3.50
6.
MAXIMUM PACKAGE WARPAGE IS 0.05 mm.
4
D
5.00 BSC
7.
MAXIMUM ALLOWABLE BURRS IS 0.076 mm IN ALL DIRECTIONS.
E
6.00 BSC
8.
PIN #1 ID ON TOP WILL BE LASER MARKED.
9.
BILATERAL COPLANARITY ZONE APPLIES TO THE EXPOSED
HEAT SINK SLUG AS WELL AS THE TERMINALS.
A
0.45
0.50
0.55
A1
0.00
0.02
0.05
K
θ
0.20 MAX.
0
---
12
2
3448\ 16-038.28 \ 04.15.05
38
S25FL040A
S25FL040A_00_B4 February 27, 2009
Data
She et
18. Revision History
Section
Description
Revision A (January 26, 2006)
Global
Initial release.
Revision A4 (June 29, 2006)
DC Characteristics
Added typical specification and changed maximum specification for ICC2.
Revision B0 (August 31, 2006)
Global
Rewrote entire document for better flow and clarity. No specifications were changed.
Revision B1 (March 14, 2007)
Global
Changed document status from Preliminary to Full Production.
RDID table
Changed structure of table.
Absolute Maximum Ratings
Added overshoot and undershoot information.
AC Characteristics
Changed maximum specification for FSCK.
Revision B2 (July 2, 2007)
Device Operations
Added a sentence to Byte or Page Programming
Revision B3 (September 29, 2008)
AC Characteristics
Changed max specification of tV (Output Valid) in Table 16.1
Revision B4 (February 27, 2009)
Global
February 27, 2009 S25FL040A_00_B4
Added obsolescence information to Cover Sheet, Distinctive Characteristics, and Ordering
Information sections of data sheet.
S25FL040A
39
D at a
S hee t
Colophon
The products described in this document are designed, developed and manufactured as contemplated for general use, including without
limitation, ordinary industrial use, general office use, personal use, and household use, but are not designed, developed and manufactured as
contemplated (1) for any use that includes fatal risks or dangers that, unless extremely high safety is secured, could have a serious effect to the
public, and could lead directly to death, personal injury, severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility,
aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control in weapon system), or (2) for
any use where chance of failure is intolerable (i.e., submersible repeater and artificial satellite). Please note that Spansion will not be liable to
you and/or any third party for any claims or damages arising in connection with above-mentioned uses of the products. Any semiconductor
devices have an inherent chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design
measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal
operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under
the Foreign Exchange and Foreign Trade Law of Japan, the US Export Administration Regulations or the applicable laws of any other country,
the prior authorization by the respective government entity will be required for export of those products.
Trademarks and Notice
The contents of this document are subject to change without notice. This document may contain information on a Spansion product under
development by Spansion. Spansion reserves the right to change or discontinue work on any product without notice. The information in this
document is provided as is without warranty or guarantee of any kind as to its accuracy, completeness, operability, fitness for particular purpose,
merchantability, non-infringement of third-party rights, or any other warranty, express, implied, or statutory. Spansion assumes no liability for any
damages of any kind arising out of the use of the information in this document.
Copyright © 2006-2009 Spansion Inc. All rights reserved. Spansion®, the Spansion Logo, MirrorBit®, MirrorBit® Eclipse™, ORNAND™,
ORNAND2™, HD-SIM™, EcoRAM™ and combinations thereof, are trademarks of Spansion LLC in the US and other countries. Other names
used are for informational purposes only and may be trademarks of their respective owners.
40
S25FL040A
S25FL040A_00_B4 February 27, 2009