S/CON/SCI0100600/D/19/12/14 Page 1/5 UK IGBT BASED DC SOLID-STATE RELAY SCI0100600 Latest high voltage IGBT technology generation. New innovative isolated driver ensuring fast power transistor turn on and off therefore low power transient. Ultra low output leakage current 4.5-32VDC Low control current consumption Control voltage range Triggered control input to avoid linear control risks Max transient peak voltage 600V Low conducted and radiated disturbances Advised max. DC Mains peak voltage (Depends on protection clamping voltage) Max. Load Current (with heatsink) 100ADC DC Mains voltage range (Depends on protection clamping voltage) Fig. 1 Load current range 0 to 100A (with heatsink) Control input voltage range In & case / Out Insulation Connections 4.5-32VDC 4kV M3 round tabs M5 round tabs HIGH SIDE WIRING DIAGRAM (Load connected to “-“) Dimensions (WxHxD) Weight 44.5 x 58.2 x 27 100g (mm) LOW SIDE WIRING DIAGRAM (Load connected to “+”) Fig. 2 Please consult us to select the right protective components C1, D1 & D2. Please consult us to select the right protective components C1, D1 & D2. The red paths (C1/D1/D2) must be as short as possible ! Fig. 3 Proud to serve you Data given at Tambient=25°C and subject to modification without previous notice The red paths (C1/D1/D2) must be as short as possible ! INTERNAL DIAGRAM ® celduc r e l a i s celduc® r e l a i S/CON/SCI0100600/D/19/12/14 s Page 2/5 UK CONTROL INPUT CHARACTERISTICS INPUT CIRCUIT CHARACTERISTIC LABEL VALUE INFO. Nom. Control voltage Ucnom 12-24VDC Nom. Control current Control voltage range Control current consumption Icnom Uc 35mADC 4.5 – 32VDC typical=4.3V 40 Ic 25 – 42mADC See curve 30 Ic (mADC) 45 35 @25°C 25 20 Releasing control voltage Ucoffmax 1VDC Typical= 3.5V Max. reverse control voltage -Ucmax 32VDC -Icmax <100µA Rin Current limitation Input impedance CONTROL CURRENT vs. CONTROL VOLTAGE Fig. 4 15 10 5 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 See curve Uc (VDC) TIME CHARACT. TIME CHARACTERISTICS CHARACTERISTIC LABEL VALUE Turn on time ton 10µs Turn on delay tdon 600µs Turn off time toff 10µs Turn off delay Max. On-Off frequency tdoff 100µs F(on-off) 700Hz POWER OUTPUT CHARACTERISTICS CHARACTERISTIC POWER CIRCUIT Mains voltage range LABEL Ut Ue VALUE INFO. Min = VCEsat (Max Advised = 350VDC) Depends on protection clamping voltage (D1) Non-repetitive peak voltage Utp 600V Overvoltage protection D1 Not integrated A voltage clamping mean must be connected across the terminals 1 & 2 (see fig 1 & 2) Please consult us to select the right protective components Off-state max reverse voltage drop (internal diode) -Ut 1.4V @Ie=100A Resistive Motor 100A Please contact us Maximum nominal currents Ie max Max. non-repetitive non-switched peak current Iepeak 550A Min. load current Iemin 0mA @Tj=25°C Max. leakage current See fig. 9 @Tc=100°C @Tj=175°C @Utp (See fig. 8) Ielk max 1mA @Utp @Tjmax Voltage drop : Resistance rt 6.4m @Tj=125°C Voltage drop : Voltage vt 0.8V @Tj=125°C Max. on-state voltage drop (Vcesat = vt + rt . Ie) VCEsat 1.35V @Tj=25°C 1.45V @Tj=125°C @Iemax Typ. output capacitance Cout 300pF Junction/case thermal resistance Rthjc 0.385K/W Built-in heatsink thermal resistance vertically mounted Rthra 10K/W @Tra=75°C Heatsink thermal time constant Tthra 10 minutes @Tra=60°C Control inputs / power outputs / case insulation voltage Uimp 4kV Isolation resistance / capacitance Rio / Cio 1G<8pF Maximum junction temperature Tjmax Storage ambient temperature Operating ambient temperature Max. case temperature Steady state = 125°C @Utp Transient = 175°C Tstg -40->+100°C Tamb -40->+90°C Tc 100°C See fig. 9 celduc® r e l a i S/CON/SCI0100600/D/19/12/14 s Page 3/5 UK OUTPUT SWITCH CHARACTERISTIC CURVES Fig. 5 VOLTAGE DROP VS LOAD CURRENT REVERSE VOLTAGE DROP VS REVERSE CURRENT Fig. 6 140 Ie (A) -Ie (A) 200 120 100 150 80 100 Tj = 25°C 60 Tj=125°C Tj = 125°C 40 Tj = 175°C 50 20 -Ut (V) VCEsat (V) 0 0 0 Fig. 7 0,18 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 0 POWER ELEMENT TRANSIENT THERMAL IMPEDANCE vs. PULSE DURATION 0,5 1 1,5 2 ON-STATE PEAK OVERLOAD CURRENT vs. PULSE DURATION Fig. 8 700 Zthjc (K/W) Ie (Apk) 0,16 600 Non-repetitive D=1% (Tc=100°C, Tjm ax=175°C) 0,14 500 0,12 0,1 D=50% 0,08 D=20% 400 300 D=10% 0,06 200 D=5% 0,04 D=2% 0,02 D=1% 100 Repetitive D=50%(Tc=100°C, Tjm ax=125°C) 0 0,0001 Single pulse 0 0,0001 0,001 0,01 Fig. 9 0,1 t (s) 0,001 0,1 Pulse 1 Duration (s) 0,01 1 POWER DISSIPATED AND LOAD CURRENT LIMIT VS TEMPERATURE Permanent current Ie (ARMS) Power dissipated Pd (W) Please refer to the installation notice for precautions about mounting the device on a heatsink. 165 110 2.2K/W 2.1K/W 1.2K/W 1.1K/W 0.9K/W 0.75K/W 0.55K/W 0.3K/W 0.2K/W 0.1K/W 100 144 90 123 80 105 70 87 60 70.9 50 55.9 40 42.2 30 29.7 20 18.5 10 8.64 8K/W 0 0 4K/W 10 0 20 30 40 50 60 10K/W = No Heatsink / 1LD12020 4K/W = 150x150x3mm aluminium sheet 2.1K/W = WF210000 1.2K/W = WF121000 1.1K/W = WF131100 0.55K/W = WF050000 0.3K/W = WF031100 0.2K/W = No reference 70 80 90 100 110 Ambient temperature (°C) 2.2K/W = WF262100 / WF151200 0.9K/W = WF115100 0.75K/W = WF070000 0.1K/W = No reference celduc® r e l a i S/CON/SCI0100600/D/19/12/14 s Page 4/5 UK MISC. CONNECTIONS GENERAL INFORMATION Connections Screwdriver advised Min and max tightening torque Insulated crimp terminals (round tabs, eyelet type) Power Control Philips™ NR2 Philips™ NR1 1.8 N.m 0.8 N.m M5 M3 Display Green LED (indicates the power element is controlled) Housing UL94V0 Mounting 2 screws (M4x12mm) Noise level No audible noise Weight See mounting sheet 100g GENERAL STANDARDS Standards Protection level IP00 Protection against direct touch None CE marking Yes UL, cULUS Yes E.M.C. IMMUNITY TYPE OF TEST E.M.C. EMISSION IEC60947-1 STANDARD LEVEL EFFECT E.S.D. (Electrostatic discharges) EN61000-4-2 Pending ? Radiated electromagnetic fields EN61000-4-3 Pending ? Fast transients bursts EN61000-4-4 Pending ? Electric chocks EN61000-4-5 Pending ? Voltage drop EN61000-4-11 - Radiated and conducted disturbances NFEN55011 Pending celduc® r e l a i S/CON/SCI0100600/D/19/12/14 s Page 5/5 UK DIMENSIONS AND ACCESSORIES Fig. 10 DIMENSIONS (mm) 28 22.8±0,5 28 Ø4.7 M5 2- 4- 3+ 47.6 1+ 25.8 25.4 5.1 7.5 43.2 58.2 19.6 44.5 M3 TOLERANCES: ± 0.3 ACCESSORIES PROTECTIVE COVER 1K470000 Please consult our website for other accessory references (Heatsinks, mounting adaptors, thermal grease…) celduc® r e l a i s www.celduc.com 5 Rue Ampère B.P. 30004 42290 SORBIERS - FRANCE E-Mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19