SCI0100600 - Celduc Relais

S/CON/SCI0100600/D/19/12/14
Page 1/5 UK
IGBT BASED
DC SOLID-STATE RELAY
SCI0100600
 Latest high voltage IGBT technology generation.
 New innovative isolated driver ensuring fast power transistor turn on
and off therefore low power transient.
 Ultra low output leakage current
4.5-32VDC
 Low control current consumption
Control voltage range
 Triggered control input to avoid linear control risks
Max transient peak
voltage
600V
 Low conducted and radiated disturbances
Advised max. DC
Mains peak voltage
(Depends on
protection clamping
voltage)
Max. Load Current
(with heatsink)
100ADC
DC Mains
voltage range
(Depends on protection
clamping voltage)
Fig. 1
Load current range
0 to 100A
(with heatsink)
Control input
voltage range
In & case / Out
Insulation
Connections
4.5-32VDC
4kV
M3 round tabs
M5 round tabs
HIGH SIDE WIRING DIAGRAM
(Load connected to “-“)
Dimensions
(WxHxD)
Weight
44.5 x 58.2 x 27
100g
(mm)
LOW SIDE WIRING DIAGRAM
(Load connected to “+”)
Fig. 2
Please consult
us to select the
right
protective
components
C1, D1 & D2.
Please consult us
to select the right
protective
components C1,
D1 & D2.
The red paths
(C1/D1/D2) must
be as short as
possible !
Fig. 3
Proud to serve you
Data given at Tambient=25°C and subject to modification without previous notice
The red paths
(C1/D1/D2)
must be as
short as
possible !
INTERNAL DIAGRAM
®
celduc
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SCI0100600/D/19/12/14
s
Page 2/5 UK
CONTROL INPUT CHARACTERISTICS
INPUT CIRCUIT
CHARACTERISTIC
LABEL
VALUE
INFO.
Nom. Control voltage
Ucnom
12-24VDC
Nom. Control current
Control voltage range
Control current
consumption
Icnom
Uc
35mADC
4.5 – 32VDC
typical=4.3V
40
Ic
25 – 42mADC
See curve
30
Ic (mADC)
45
35
@25°C
25
20
Releasing control voltage
Ucoffmax
1VDC
Typical= 3.5V
Max. reverse control
voltage
-Ucmax
32VDC
-Icmax <100µA
Rin
Current
limitation
Input impedance
CONTROL CURRENT
vs. CONTROL VOLTAGE
Fig. 4
15
10
5
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32
See curve
Uc (VDC)
TIME CHARACT.
TIME CHARACTERISTICS
CHARACTERISTIC
LABEL
VALUE
Turn on time
ton
10µs
Turn on delay
tdon
600µs
Turn off time
toff
10µs
Turn off delay
Max. On-Off frequency
tdoff
100µs
F(on-off)
700Hz
POWER OUTPUT CHARACTERISTICS
CHARACTERISTIC
POWER CIRCUIT
Mains voltage range
LABEL
Ut
Ue
VALUE
INFO.
Min = VCEsat
(Max Advised = 350VDC)
Depends on protection
clamping voltage (D1)
Non-repetitive peak voltage
Utp
600V
Overvoltage protection
D1
Not integrated
A voltage clamping mean must be connected across the
terminals 1 & 2 (see fig 1 & 2)
Please consult us to select
the right protective
components
Off-state max reverse voltage drop
(internal diode)
-Ut
1.4V
@Ie=100A
Resistive
Motor
100A
Please contact us
Maximum nominal currents
Ie max
Max. non-repetitive non-switched
peak current
Iepeak
550A
Min. load current
Iemin
0mA
@Tj=25°C
Max. leakage current
See fig. 9
@Tc=100°C @Tj=175°C
@Utp (See
fig. 8)
Ielk max
1mA
@Utp @Tjmax
Voltage drop : Resistance
rt
6.4m
@Tj=125°C
Voltage drop : Voltage
vt
0.8V
@Tj=125°C
Max. on-state voltage drop
(Vcesat = vt + rt . Ie)
VCEsat
1.35V @Tj=25°C
1.45V @Tj=125°C
@Iemax
Typ. output capacitance
Cout
300pF
Junction/case thermal resistance
Rthjc
0.385K/W
Built-in heatsink thermal resistance
vertically mounted
Rthra
10K/W
@Tra=75°C
Heatsink thermal time constant
Tthra
10 minutes
@Tra=60°C
Control inputs / power outputs / case
insulation voltage
Uimp
4kV
Isolation resistance / capacitance
Rio / Cio
1G<8pF
Maximum junction temperature
Tjmax
Storage ambient temperature
Operating ambient temperature
Max. case temperature
Steady state = 125°C
@Utp
Transient = 175°C
Tstg
-40->+100°C
Tamb
-40->+90°C
Tc
100°C
See fig. 9
celduc®
r
e
l
a
i
S/CON/SCI0100600/D/19/12/14
s
Page 3/5 UK
OUTPUT SWITCH CHARACTERISTIC CURVES
Fig. 5
VOLTAGE DROP VS LOAD CURRENT
REVERSE VOLTAGE DROP
VS REVERSE CURRENT
Fig. 6
140
Ie (A)
-Ie (A)
200
120
100
150
80
100
Tj = 25°C
60
Tj=125°C
Tj = 125°C
40
Tj = 175°C
50
20
-Ut (V)
VCEsat (V)
0
0
0
Fig. 7
0,18
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
2
0
POWER ELEMENT TRANSIENT THERMAL IMPEDANCE
vs. PULSE DURATION
0,5
1
1,5
2
ON-STATE PEAK OVERLOAD CURRENT vs. PULSE
DURATION
Fig. 8
700
Zthjc (K/W)
Ie (Apk)
0,16
600
Non-repetitive D=1% (Tc=100°C, Tjm ax=175°C)
0,14
500
0,12
0,1
D=50%
0,08
D=20%
400
300
D=10%
0,06
200
D=5%
0,04
D=2%
0,02
D=1%
100
Repetitive D=50%(Tc=100°C, Tjm ax=125°C)
0
0,0001
Single pulse
0
0,0001
0,001
0,01
Fig. 9
0,1
t (s)
0,001
0,1 Pulse 1
Duration (s)
0,01
1
POWER DISSIPATED AND LOAD CURRENT LIMIT VS TEMPERATURE
Permanent current
Ie (ARMS)
Power dissipated
Pd (W)
Please refer to the installation notice for precautions about
mounting the device on a heatsink.
165
110
2.2K/W
2.1K/W
1.2K/W
1.1K/W
0.9K/W
0.75K/W
0.55K/W
0.3K/W
0.2K/W
0.1K/W
100
144
90
123
80
105
70
87
60
70.9
50
55.9
40
42.2
30
29.7
20
18.5
10
8.64
8K/W
0
0
4K/W
10
0
20
30
40
50
60
10K/W = No Heatsink / 1LD12020
4K/W = 150x150x3mm aluminium sheet
2.1K/W = WF210000
1.2K/W = WF121000
1.1K/W = WF131100
0.55K/W = WF050000
0.3K/W = WF031100
0.2K/W = No reference
70
80
90
100
110
Ambient temperature (°C)
2.2K/W = WF262100 / WF151200
0.9K/W = WF115100
0.75K/W = WF070000
0.1K/W = No reference
celduc®
r
e
l
a
i
S/CON/SCI0100600/D/19/12/14
s
Page 4/5 UK
MISC.
CONNECTIONS
GENERAL INFORMATION
Connections
Screwdriver advised
Min and max tightening torque
Insulated crimp terminals (round
tabs, eyelet type)
Power
Control
Philips™ NR2
Philips™ NR1
1.8 N.m
0.8 N.m
M5
M3
Display
Green LED
(indicates the power element is controlled)
Housing
UL94V0
Mounting
2 screws (M4x12mm)
Noise level
No audible noise
Weight
See mounting
sheet
100g
GENERAL
STANDARDS
Standards
Protection level
IP00
Protection against direct touch
None
CE marking
Yes
UL, cULUS
Yes
E.M.C.
IMMUNITY
TYPE OF TEST
E.M.C.
EMISSION
IEC60947-1
STANDARD
LEVEL
EFFECT
E.S.D. (Electrostatic discharges)
EN61000-4-2
Pending
?
Radiated electromagnetic fields
EN61000-4-3
Pending
?
Fast transients bursts
EN61000-4-4
Pending
?
Electric chocks
EN61000-4-5
Pending
?
Voltage drop
EN61000-4-11
-
Radiated and conducted
disturbances
NFEN55011
Pending
celduc®
r
e
l
a
i
S/CON/SCI0100600/D/19/12/14
s
Page 5/5 UK
DIMENSIONS AND ACCESSORIES
Fig.
10
DIMENSIONS (mm)
28
22.8±0,5
28
Ø4.7
M5
2-
4-
3+
47.6
1+
25.8
25.4
5.1
7.5
43.2
58.2
19.6
44.5
M3
TOLERANCES: ± 0.3
ACCESSORIES
PROTECTIVE COVER
1K470000
Please consult our website for other accessory references
(Heatsinks, mounting adaptors, thermal grease…)
celduc®
r
e
l
a
i
s
www.celduc.com
5 Rue Ampère B.P. 30004
42290 SORBIERS - FRANCE
E-Mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19