S/CON/SCI0251700/C/19/12/14 Page 1/5 UK IGBT BASED DC SOLID-STATE RELAY SCI0251700 Latest high voltage IGBT technology generation. New innovative isolated driver ensuring fast power transistor turn on and off therefore low power transient. Ultra low output leakage current Max transient peak voltage Advised max. DC Mains peak voltage Max. Load Current (with heatsink) Triggered control input to avoid linear control risks Low conducted and radiated disturbances DC Mains voltage range 820VDC Max Advised (Depends on protection clamping voltage) Fig. 1 Load current range 0 to 25A (with heatsink) 4.5-32VDC Control voltage range Low control current consumption Control input voltage range In & case / Out Insulation Connections 4.5-32VDC 4kV M3 round tabs M5 round tabs HIGH SIDE WIRING DIAGRAM (Load connected to “-“) 1700V 820VDC 25ADC Dimensions (WxHxD) Weight 44.5 x 58.2 x 27 100g (mm) LOW SIDE WIRING DIAGRAM (Load connected to “+”) Fig. 2 Please consult us to select the right protective components C1, D1 & D2. Please consult us to select the right protective components C1, D1 & D2. The red paths (C1/D1/D2) must be as short as possible ! The red paths (C1/D1/D2) must be as short as possible ! Fig. 3 Proud to serve you Data given at Tambient=25°C and subject to modification without previous notice INTERNAL DIAGRAM ® celduc r e l a i s celduc® r e l a i S/CON/SCI0251700/C/19/12/14 s Page 2/5 UK CONTROL INPUT CHARACTERISTICS INPUT CIRCUIT CHARACTERISTIC LABEL VALUE INFO. Nom. Control voltage Ucnom 12-24VDC Nom. Control current Control voltage range Control current consumption Icnom Uc 35mADC 4.5 – 32VDC typical=4.3V 40 Ic 25 – 42mADC See curve 30 CONTROL CURRENT vs. CONTROL VOLTAGE Fig. 4 Ic (mADC) 45 35 @25°C 25 20 Releasing control voltage Ucoffmax 1VDC Typical= 3.5V Max. reverse control voltage -Ucmax 32VDC -Icmax <100µA Rin Current limitation 15 10 5 0 Input impedance 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 See curve Uc (VDC) TIME CHARACT. TIME CHARACTERISTICS CHARACTERISTIC LABEL VALUE Turn on time ton 10µs Turn on delay tdon 600µs Turn off time toff 50µs Turn off delay Max. On-Off frequency tdoff 100µs F(on-off) 200Hz POWER OUTPUT CHARACTERISTICS CHARACTERISTIC POWER CIRCUIT Mains voltage range LABEL Ut Ue VALUE INFO. Min = VCEsat Max (Advised) = 820VDC Depends on protection clamping voltage (D1) Non-repetitive peak voltage Utp 1700V Overvoltage protection D1 Not integrated A voltage clamping mean must be connected across the terminals 1 & 2 (see fig 1 & 2) Please consult us to select the right protective components Off-state max reverse voltage drop (internal diode) -Ut 3.3V @Ie=16A Resistive Motor 50A Please contact us Maximum nominal currents Ie max Max. non-repetitive peak current Iepeak 40A / 1ms Min. load current Iemin 5mA Max. leakage current Ielk max 1.5mA @Utp @Tjmax Max. on-state voltage VCEsat 3.3V @Ie=16A Typ. output capacitance Cout 90pF @Utp Junction/case thermal resistance Rthjc 1.25K/W Built-in heatsink thermal resistance vertically mounted Rthra 10K/W @Tra=75°C Heatsink thermal time constant Tthra 10 minutes @Tra=60°C Control inputs/power outputs insulation voltage Uimp 4kV Inputs/case insulation voltage Uimp 4kV Outputs/case insulation voltage Uimp 4kV Rio 1G Isolation resistance Isolation capacitance Maximum junction temperature Storage ambient temperature Operating ambient temperature Max. case temperature Cio <8pF Tjmax 175°C Tstg -40->+100°C Tamb -40->+90°C Tc 100°C See fig. 9 @Tc=25°C See fig. 9 celduc® r e l a i S/CON/SCI0251700/C/19/12/14 s Page 3/5 UK OUTPUT SWITCH CHARACTERISTIC CURVES Fig. 5 VOLTAGE DROP VS LOAD CURRENT Ic (A) 100 REVERSE VOLTAGE DROP VS REVERSE CURRENT Fig. 6 If (A) 280 80 240 200 60 160 120 40 Tj = 25°c Vf @25° 80 Vf @175° Tj = 175°c 20 40 0 0 0 0,5 1,5 2 2,5 Vcesat (V) 0 3 POWER ELEMENT TRANSIENT THERMAL IMPEDANCE vs. PULSE DURATION Fig. 7 1 1 0,5 Fig. 8 1 1,5 2 2,5 3 3,5 Vf (V) 4 ON-STATE PEAK OVERLOAD CURRENT vs. PULSE DURATION Zth (K/W) Ie (Apk) 1000 0,1 100 Single pulse D=1% D=2% 0,01 10 Repetitive D=50% (Tc = 100°C, Tjmax = 125°C) D=5% No repetitive D=1% (Tc = 100°C, Tjmax = 175°C) D=10% D=20% D=50% 1 0,0001 0,001 0,00001 0,0001 0,001 Fig. 9 0,01 0,1 t (sec) 0,001 0,01 0,1 t (sec) 1 POWER DISSIPATED AND LOAD CURRENT LIMIT VS TEMPERATURE Permanent current Ie (ARMS) Power dissipated Pd (W) Please refer to the installation notice for precautions about mounting the device on a heatsink. 30 87 1.3K/W 1.2K/W 1.1K/W 0.9K/W 0.75K/W 0.55K/W 0.3K/W 0.2K/W 0.1K/W 25 72.5 20 58 15 43.5 10 29 14.5 5 8K/W 4K/W 2.4K/W 2.2K/W 2.1K/W 1.95K/W 1.5K/W 0 0 0 10 20 30 40 50 60 10K/W = No Heatsink / 1LD12020 4K/W = 150x150x3mm aluminium sheet 2.1K/W = WF210000 1.2K/W = WF121000 1.1K/W = WF131100 0.55K/W = WF050000 0.3K/W = WF031100 0.2K/W = No reference 70 80 90 100 110 Ambient temperature (°C) 2.2K/W = WF262100 / WF151200 0.9K/W = WF115100 0.75K/W = WF070000 0.1K/W = No reference 1 celduc® r e l a i S/CON/SCI0251700/C/19/12/14 s Page 4/5 UK MISC. CONNECTIONS GENERAL INFORMATION Connections Power Control Philips™ NR2 Philips™ NR1 1.8 N.m 0.8 N.m Insulated crimp terminals (round tabs, eyelet type) M5 M3 Display Green LED (indicates relay has switched ON) Housing UL94V0 Screwdriver advised Min and max tightening torque Mounting 2 screws (M4x12mm) Noise level No audible noise Weight See mounting sheet 100g GENERAL STANDARDS Standards Protection level IP00 Protection against direct touch None CE marking Yes UL, cULUS Yes E.M.C. IMMUNITY TYPE OF TEST E.M.C. EMISSION IEC60947-1 STANDARD LEVEL EFFECT E.S.D. (Electrostatic discharges) EN61000-4-2 Pending ? Radiated electromagnetic fields EN61000-4-3 Pending ? Fast transients bursts EN61000-4-4 Pending No effect Electric chocks EN61000-4-5 Pending ? Voltage drop EN61000-4-11 - Radiated and conducted disturbances NFEN55011 Pending celduc® r e l a i S/CON/SCI0251700/C/19/12/14 s Page 5/5 UK DIMENSIONS AND ACCESSORIES Fig. 10 DIMENSIONS (mm) 28 22.8±0,5 28 Ø4.7 M5 2- 4- 3+ 47.6 1+ 25.8 25.4 5.1 7.5 43.2 58.2 19.6 44.5 M3 TOLERANCES: ± 0.3 ACCESSORIES PROTECTIVE COVER 1K470000 Please consult our website for other accessory references (Heatsinks, mounting adaptors, thermal grease…) celduc® r e l a i s www.celduc.com 5 Rue Ampère B.P. 30004 42290 SORBIERS - FRANCE E-Mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19