CELDUC SCM040600

celduc®
r
e
l
a
i
S/CON/SCM040600/A/16/03/05
s
PRELIMINARY DATA
Page 1/5 GB
MOSFET BASED
DC SOLID STATE RELAY
SCM040600
X Latest MOSFET technology generation.
X Ultra low on-state resistance.
X New innovative isolated driver ensuring fast power transistor
turn on and off therefore low power transient.
X Ultra low output leakage current
X Low control current consumption
Control voltage
range
Max. output peak
voltage
Nom. load current
with heatsink
X Triggered control input to avoid linear control risks
X Low conducted and radiated disturbances
Load voltage
range
Load current
range
Depends on protection
clamping voltage
(with heatsink)
Fig. 1
0 to 40A
Control input
voltage range
In & case / Out
Insulation
Connections
4.5-32VDC
4kV
M3 round tabs
M5 round tabs
HIGH SIDE WIRING DIAGRAM
(Load connected to “-“)
4.5-32VDC
600VDC
40ADC
Dimensions
(WxHxD)
Weight
44.5 x 58.2 x 27
100g
(mm)
LOW SIDE WIRING DIAGRAM
(Load connected to “+”)
Fig. 2
See Instruction
sheet for
selective the
right
protective
components
See Instruction
sheet for selective
the right
protective
components
(Red paths as
short as possible)
Fig. 3
Proud to serve you
Data given at Tambient=40°C and subject to modification without previous notice
(Red paths as
short as
possible)
INTERNAL DIAGRAM
celduc
®
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SCM040600/A/16/03/05
s
Page 2/5 GB
CONTROL INPUT CHARACTERISTICS
INPUT CIRCUIT
CHARACTERISTIC
LABEL
VALUE
INFO.
Control voltage range
Uc
4.5 – 32VDC
Current consumption
Ic
25 – 42mADC for control voltage range
Typical turn on voltage
Ucontyp
4.3V
Min. releasing voltage
Ucoffmin
1VDC
Typical releasing voltage
Ucofftyp
3.5V
Max. input voltage
Ucmax
32VDC
Max. reverse voltage
-Ucmax
32VDC
Max. reverse leakage current
-Icmax
100µA
Re
Current limitation
Input impedance
See fig. 5
See fig. 5
POWER OUTPUT CHARACTERISTICS
CHARACTERISTIC
LABEL
VALUE
Mains voltage range
Ue
Depends on protection clamping voltage (D1)
Non-repetitive peak voltage
Utp
600V
Overvoltage protection
D1
Not integrated
A voltage clamping mean must be connected across the
terminals 1 & 2 (see fig 1 & 2)
Reverse voltage (internal diode)
-Ut
1,2V
Max. repetitive avalanche
current
Iep
20A
Max. single pulse avalanche
energy
Eep
1800mJ
@Ut=50V
@Ie=10A
Max. repetitive pulse avalanche
energy
Eep
1mJ
@Ie=20A
POWER CIRCUIT
Maximum nominal currents
Ie
INFO.
See Instruction
sheet for selective
the right
protective
components
@Ie=-47A
@Uc=0
Pulse width
limited by Tj
max
Resistive
Motor
40A
Please consult us
See fig. 7
Values with
heatsink
Non-repetitive peak overload
current
Iepeak
Min. load current
Iemin
0mA
Ielk
250µADC
@Utp @Tjmax
Max. on-state resistance
RDSon
140mΩ
@Iemax @Tjmax
Typ. output capacitance
Cout
2.2nF
Junction/case thermal
resistance per power element
Rthjc
0.4K/W
Total = 1
power
elements
Built-in heatsink thermal
resistance vertically mounted
Rthra
8K/W
@∆Tra=60°C
Heatsink thermal time constant
Tthra
10min
@∆Tra=60°C
Control inputs/power outputs
insulation voltage
Uimp
4kV
Inputs/case insulation voltage
Uimp
4kV
Outputs/case insulation voltage
Uimp
4kV
Rio
1GΩ
Max. leakage current
Isolation resistance
Isolation capacitance
Maximum junction temperature
Storage ambient temperature
Operating ambient temperature
Max. case temperature
140A
Cio
<8pF
Tjmax
150°C
Tstg
-40->+100°C
Tamb
-40->+90°C
Tc
100°C
See fig. 8
See fig. 7
celduc®
r
e
l
a
i
S/CON/SCM040600/A/16/03/05
s
Page 3/5 GB
TIME CHARACTERISTICS
TIME CHARACT.
Fig. 4
TIME DIAGRAMS
CHARACTERISTIC
LABEL
VALUE
Turn on time
ton
10µs (1.2µs typical)
Turn on delay
tdon
600µs (500µs typical)
Turn off time
toff
10µs (1µs typical)
tdoff
100µs (60µs typical)
F(on-off)
700Hz
Turn off delay
Max. On-Off frequency
INFO.
MISC.
CONNECTIONS
GENERAL INFORMATION
Connections
Power
Control
Philips™ NR2
Philips™ NR1
1.8 N.m
0.8 N.m
Insulated crimp terminals
(round tabs, eyelet type)
M5
M3
Display
Green LED
(indicates relay has switched ON)
Screwdriver advised
Min and max tightening torque
Housing
UL94V0
Mounting
2 screws (M4x12mm)
Noise level
No audible noise
Weight
See mounting
sheet
100g
E.M.C.
EMISSION
E.M.C.
IMMUNITY
GENERAL
STANDARDS
Standards
IEC60947-1
Protection level
IP00
Protection against direct touch
None
CE marking
Yes
UL, cULUS and VDE approvals
Pending
TYPE OF TEST
STANDARD
LEVEL
EFFECT
E.S.D. (Electrostatic discharges)
EN61000-4-2
Pending
?
Radiated electromagnetic fields
EN61000-4-3
Pending
?
Fast transients bursts
EN61000-4-4
4kV coupling by clamp on the input side and direct for power side
No effect
Electric chocks
EN61000-4-5
1kV direct coupling on the input side (pending for power side)
?
Voltage drop
EN61000-4-11
-
Radiated and conducted
disturbances
NFEN55011
Pending
celduc®
r
e
l
a
i
S/CON/SCM040600/A/16/03/05
s
Page 4/5 GB
CHARACTERISTIC CURVES
Fig. 5
INPUT CHARACTERISTIC
Fig. 6
Ic (mADC)
45
ON RESISTANCE VS TEMPERATURE
RDSon
200
(mOhms)
40
180
35
160
30
140
@25°C
120
25
100
20
80
15
60
10
40
5
20
0
0
0
2
4
6
8
-50
10 12 14 16 18 20 22 24 26 28 30 32
0
50
Fig. 7
100
150
Junction Temperature (°C)
Uc (VDC)
POWER DISSIPATED AND LOAD CURRENT LIMIT VS TEMPERATURE
Permanent current
Ie (ARMS)
Power dissipated
(W)
Please refere to the installation notice for
precautions about mounting the device on a heatsink.
45
284
1.3K/W
1.2K/W
1.1K/W
0.9K/W
0.75K/W
0.55K/W
0.3K/W
0.2K/W
0.1K/W
40
224
35
172
30
126
25
87.5
20
56
15
31.5
10
14
3.5
5
8K/W
4K/W
2.4K/W
2.2K/W
2.1K/W
1.95K/W
1.5K/W
0
0
0
10
20
8K/W = No Heatsink
2.1K/W = WF210000
1.1K/W = WF131100
0.3K/W = WF031100
30
40
4K/W = No reference
1.95K/W = WF191100
0.9K/W = WF092000
0.2K/W = WF020000
Fig. 8
50
60
70
2.4K/W = WF152100
1.5K/W = WF141100
0.9K/W = WF115100
0.1K/W = No reference
80
90
100
110
Ambient temperature (°C)
2.2K/W = WF262100
1.3K/W = WF129100
0.7K/W = WF070000
2.2K/W = WF151200
1.2K/W = WF121000
0.55K/W = WF050000
CURRENT OVERLOAD CHARACTERISTIC
Ie 150
(A) 140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
Non repetitive peak overload
switching current vs overvoltage
protection clamping voltage (D1)
Single pulse
F(on-off)=50Hz
F(on-off)=100Hz
F(on-off)=700Hz
Ie 140
(A)
120
Non repetitive
on-state (no switching)
max. peak current
vs
overload pulse duration
100
80
60
40
20
0
0
100
200
300
400
500
600
Utpk (V)
0.1
1
10
100
1000
Pulse duration (ms)
celduc®
r
e
l
a
i
S/CON/SCM040600/A/16/03/05
s
Page 5/5 GB
DIMENSIONS AND ACCESSORIES
Fig. 9
DIMENSIONS
28
±0,5
22.8
28
Ø4.7
M5
2-
4-
3+
47.6
1+
25.4
25.8
44.5
5.1
7.5
43.2
58.2
19.6
M3
TOLERANCES: ± 0.3
Fig.
10
ACCESSORIES
PROTECTIVE COVER 1K470000
celduc®
r
e
l
a
i
s
www.celduc.com
Rue Ampère B.P. 4
42290 SORBIERS - France
Phone : 33 (0) 4 77 53 90 21 Fax : 33 (0) 4 77 53 85 51 Email : [email protected]