S/CON/SCM0100200/F/19/12/14 Page 1/5 GB MOSFET BASED DC SOLID STATE RELAY SCM0100200 Latest MOSFET technology generation. Ultra low on-state resistance. New innovative isolated driver ensuring fast power transistor turn on and off therefore low power transient. Ultra low output leakage current Low control current consumption Max. output peak voltage Nom. load current with heatsink Low conducted and radiated disturbances Load voltage range Load current range Depends on protection clamping voltage (with heatsink) Fig. 1 0 to 100A Control input voltage range In & case / Out Insulation Connections 4.5-32VDC 4kV M3 round tabs M5 round tabs HIGH SIDE WIRING DIAGRAM (Load connected to “-“) 4.5-32VDC Control voltage range Triggered control input to avoid linear control risks 200VDC 100ADC Dimensions (WxHxD) Weight 44.5 x 58.2 x 27 100g (mm) LOW SIDE WIRING DIAGRAM (Load connected to “+”) Fig. 2 Please consult us to select the right protective components C1, D1 & D2. Please consult us to select the right protective components C1, D1 & D2. The red paths (C1/D1/D2) must be as short as possible ! The red paths (C1/D1/D2) must be as short as possible ! Fig. 3 Proud to serve you Data given at Tambient=40°C and subject to modification without previous notice INTERNAL DIAGRAM ® celduc r e l a i s celduc® r e l a i S/CON/SCM0100200/F/19/12/14 s Page 2/5 GB CONTROL INPUT CHARACTERISTICS INPUT CIRCUIT CHARACTERISTIC LABEL VALUE INFO. Control voltage range Uc 4.5 – 32VDC Current consumption Ic 25 – 42mADC for control voltage range Typical turn on voltage Ucontyp 4.3V Min. releasing voltage Ucoffmin 1VDC Typical releasing voltage Ucofftyp 3.5V Max. input voltage Ucmax 32VDC Max. reverse voltage -Ucmax 32VDC Max. reverse leakage current -Icmax 100µA Re Current limitation Input impedance See fig. 5 See fig. 5 POWER OUTPUT CHARACTERISTICS CHARACTERISTIC LABEL VALUE Mains voltage range Ue Depends on protection clamping voltage (D1) Non-repetitive peak voltage Utp 200V Overvoltage protection D1 Not integrated A voltage clamping mean must be connected across the terminals 1 & 2 (see fig 1 & 2) Reverse voltage (internal diode) -Ut 1,6V Max. repetitive avalanche current Iep 100A Max. single pulse avalanche energy Eep 750mJ @Ut=50V @Ie=Iep Max. repetitive pulse avalanche energy Eep 58mJ @Ie=56A POWER CIRCUIT Maximum nominal currents INFO. See Instruction sheet for selective the right protective components @Ie=-100A @Uc=0 Pulse width limited by Tj max Resistive Motor 100A Please consult us Ie See fig. 7 Values with heatsink Non-repetitive peak overload current Iepeak Min. load current Iemin 0mA Ielk 250µADC @Utp @Tjmax Max. on-state resistance RDSon 22m @Iemax @Tjmax Typ. output capacitance Cout 1.5nF Junction/case thermal resistance per power element Rthjc 0.4K/W Total = 2 power elements Built-in heatsink thermal resistance vertically mounted Rthra 8K/W @Tra=60°C Heatsink thermal time constant Tthra 10min @Tra=60°C Control inputs/power outputs insulation voltage Uimp 4kV Inputs/case insulation voltage Uimp 4kV Outputs/case insulation voltage Uimp 4kV Rio 1G Max. leakage current Isolation resistance Isolation capacitance Maximum junction temperature Storage ambient temperature Operating ambient temperature Max. case temperature 380A Cio <8pF Tjmax 175°C Tstg -40->+100°C Tamb -40->+90°C Tc 100°C See fig. 8 See fig. 7 celduc® r e l a i S/CON/SCM0100200/F/19/12/14 s Page 3/5 GB TIME CHARACTERISTICS TIME CHARACT. Fig. 4 TIME DIAGRAMS CHARACTERISTIC LABEL VALUE INFO. Turn on time ton 10µs (1.2µs typical) Turn on delay tdon 600µs (500µs typical) Turn off time toff 10µs (1µs typical) Turn off delay tdoff 100µs (60µs typical) F(on-off) 700Hz Max. On-Off frequency MISC. CONNECTIONS GENERAL INFORMATION Connections Power Control Philips™ NR2 Philips™ NR1 1.8 N.m 0.8 N.m Insulated crimp terminals (round tabs, eyelet type) M5 M3 Display Green LED (indicates relay has switched ON) Housing UL94V0 Screwdriver advised Min and max tightening torque Mounting 2 screws (M4x12mm) Noise level No audible noise Weight See mounting sheet 100g GENERAL STANDARDS Standards Protection level IP00 Protection against direct touch None CE marking Yes UL, cULUS Yes E.M.C. IMMUNITY TYPE OF TEST E.M.C. EMISSION IEC60947-1 STANDARD LEVEL EFFECT E.S.D. (Electrostatic discharges) EN61000-4-2 Pending ? Radiated electromagnetic fields EN61000-4-3 Pending ? Fast transients bursts EN61000-4-4 4kV coupling by clamp on the input side and direct for power side No effect Electric chocks EN61000-4-5 1kV direct coupling on the input side (pending for power side) ? Voltage drop EN61000-4-11 - Radiated and conducted disturbances NFEN55011 Pending celduc® r e l a i S/CON/SCM0100200/F/19/12/14 s Page 4/5 GB CHARACTERISTIC CURVES Fig. 5 INPUT CHARACTERISTIC Fig. 6 Ic (mADC) 45 ON RESISTANCE VS TEMPERATURE RDSon 25 (mOhms) 40 20 35 30 @25°C 15 25 20 10 15 5 10 5 0 0 0 2 4 6 8 -50 10 12 14 16 18 20 22 24 26 28 30 32 0 50 100 150 Junction Temperature (°C) Uc (VDC) Fig. 7 POWER DISSIPATED AND LOAD CURRENT LIMIT VS TEMPERATURE Permanent current Ie (ARMS) Power dissipated (W) Please refere to the installation notice for precautions about mounting the device on a heatsink. 110 266 1.3K/W 1.2K/W 1.1K/W 0.9K/W 0.75K/W 0.55K/W 0.3K/W 0.2K/W 0.1K/W 100 220 90 178 80 141 70 108 60 79.2 50 55 40 35.2 30 19.8 20 8.8 2.2 10 8K/W 4K/W 2.4K/W 2.2K/W 2.1K/W 1.95K/W 1.5K/W 0 0 0 10 20 30 40 50 60 70 80 90 100 110 Ambient temperature (°C) 8K/W = No Heatsink 4K/W = No reference 2.4K/W = WF152100 2.2K/W = WF262100 2.2K/W = WF151200 2.1K/W = WF210000 1.95K/W = WF191100 1.5K/W = WF141100 1.3K/W = WF129100 1.2K/W = WF121000 1.1K/W = WF131100 0.9K/W = WF092000 0.9K/W = WF115100 0.7K/W = WF070000 0.55K/W = WF050000 0.3K/W = WF031100 0.2K/W = WF020000 0.1K/W = No reference Fig. 8 CURRENT OVERLOAD CHARACTERISTIC Ie 400 (A) 380 360 340 320 300 280 260 240 220 200 180 160 140 120 100 80 60 40 20 0 Non repetitive on-state (no switching) max. peak current vs overload pulse duration 0,1 1 10 100 1000 Pulse duration (ms) celduc® r e l a i S/CON/SCM0100200/F/19/12/14 s Page 5/5 GB DIMENSIONS AND ACCESSORIES Fig. 9 DIMENSIONS 28 22.8±0,5 28 Ø4.7 M5 2- 4- 3+ 47.6 1+ 25.8 25.4 5.1 7.5 43.2 58.2 19.6 44.5 M3 TOLERANCES: ± 0.3 Fig. 10 ACCESSORIES PROTECTIVE COVER 1K470000 ® celduc r e l a i www.celduc.com s 5 Rue Ampère B.P. 30004 42290 SORBIERS - FRANCE E-Mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19