XKLD31006 - Celduc Relais

celduc®
r
e
l
a
i
S/INT/XKLD31006/A/13/01/09
s
PRELIMINARY
Page 1/5 UK
MOSFET BASED
DC SOLID STATE RELAY
XKLD31006
u For DIN RAIL mounting
u Latest MOSFET technology generation.
u Ultra low voltage drop.
u Built-in overvoltage protection
u Control display LED (green)
u Applications :
è Traffic lights
è Small motors, electromagnets, lights, heaters
è Measurement products
è …
Control
voltage range
10-30VDC
Max output
peak voltage
60V
(clamp=40V)
Nom. load current
without heatsink
10ADC
Application
voltages
Load current
range
Control input
voltage range
In & case / Out
Insulation
Connections
Dimensions
(WxHxD in mm)
Weight
12-24-36VDC
0 to 10A
10-30VDC
2.5kV
Terminal block with
screws
12.2 x 76.4 x 53
30g
Fig. 1
HIGH SIDE WIRING DIAGRAM
(Load connected to “-“)
LOW SIDE WIRING DIAGRAM
(Load connected to “+”)
Fig. 2
D2 selection : VRRM > Uep, IFav > Ie, trr<1µs
Red paths should be as short as possible!
Fig. 3
Proud to serve you
Data given at Tambient=25°C and subject to modification without previous notice
D2 selection : VRRM > Uep, IFav > Ie, trr<1µs
Red paths should be as short as possible!
INTERNAL DIAGRAM
celduc
®
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/INT/XKLD31006/A/13/01/09
s
PRELIMINARY
Page 2/5 UK
INPUT CIRCUIT
CONTROL INPUT CHARACTERISTICS
CHARACTERISTIC
LABEL
VALUE
INFO.
Nominal control voltage
Ucnom
12-24VDC
Nominal control current
Icnom
9-20mADC
Control voltage range
Uc
10 – 30VDC
Current consumption
Ic
7-26mADC
Ucoffmax
1VDC
-Ucmax
30VDC
Rin
1000Ω
Releasing voltage
Max. reverse voltage
Input impedance
See fig. 5
See fig. 5
POWER OUTPUT CHARACTERISTICS
CHARACTERISTIC
Mains Nominal voltage
Mains voltage range
VALUE
INFO.
Uenom
12-24-36VDC
Ue
10-40VDC
Uep
60V
Overvoltage protection
D1
Pulse = 600W 1.2/50µs
Permanent = 0.5W
Reverse voltage drop
(internal diode)
-Ue
0.82VDC
@Ie=10A
@Uc=0
Ie
10A
See fig. 7
for limits
Non-repetitive peak overload
current
Iepeak
100A @10ms
See fig. 8
Min. load current
Iemin
0.1mA
Ielk
0.1mADC
Non-repetitive peak voltage
Maximum nominal currents
POWER CIRCUIT
LABEL
Max. leakage current
Max. on-state resistance
RDSon
14mΩ @Tj=25°C
@Uep @Tjmax
22.4mΩ @Tj=125°C
@Iemax
Typ. output capacitance
Cout
360pF
@1MHz
@VDS=25V
@Uc=0
Junction/case thermal
resistance per power element
Rthjc
1K/W
Total = 1
power
elements
Relay/ambient thermal
resistance vertically mounted
Rthra
22K/W
@∆Tra=60°C
Relay thermal time constant
Tthra
2min
@∆Tra=60°C
Control inputs/power outputs
insulation voltage
Uimp
2.5kV
Inputs/case insulation voltage
Uimp
2.5kV
Outputs/case insulation voltage
Uimp
2.5kV
Isolation resistance
Rio
1GΩ
Isolation capacitance
Cio
<8pF
Maximum junction temperature
Storage ambient temperature
Operating ambient temperature
Max. case temperature
Tjmax
175°C
Tstg
-40->+100°C
Tamb
-25->+90°C
Tc
100°C
See fig. 7
celduc®
r
e
l
a
i
S/INT/XKLD31006/A/13/01/09
s
PRELIMINARY
Page 3/5 UK
TIME CHARACTERISTICS
TIME CHARACT.
Fig. 4
TIME DIAGRAMS
CHARACTERISTIC
LABEL
VALUE
Turn on time
ton
1µs
Turn on delay
tdon
10µs
Turn off time
toff
10µs
Turn off delay
tdoff
150µs
F(on-off)
1 to 700Hz depending on the circuit configuration :
please consult us
Max. On-Off frequency
INFO.
GENERAL INFORMATION
Green
MISC.
Display LED (control)
UL94V0
Housing
Mounting
DIN RAIL
Noise level
No audible noise
30g
Weight
E.M.C.
EMISSION
E.M.C.
IMMUNITY
GENERAL
STANDARDS
IEC60947-1
Standards
Protection level
IP00
Protection against direct touch
None
Yes
CE marking
Pending
UL, cULUS and VDE approvals
TYPE OF TEST
STANDARD
LEVEL
EFFECT
E.S.D. (Electrostatic discharges)
EN61000-4-2
Pending
?
Radiated electromagnetic fields
EN61000-4-3
Pending
?
Fast transients bursts
EN61000-4-4
Pending
No effect
Electric chocks
EN61000-4-5
Pending
?
Voltage drop
EN61000-4-11
-
Radiated and conducted
disturbances
NFEN55011
Pending
celduc®
r
e
l
a
i
S/INT/XKLD31006/A/13/01/09
s
PRELIMINARY
Page 4/5 UK
CHARACTERISTIC CURVES
Fig. 5
INPUT CHARACTERISTIC
Fig. 6
Ic
(mADC) 30
ON-STATE VOLTAGE DROP VS TEMPERATURE
RDSon
35
(mO)
30
25
25
20
20
@25°C
15
15
10
10
5
5
0
0
0
5
10
15
Fig. 7
20
-50
25
30
Uc (VDC)
0
50
100
150
Junction Temperature (°C)
LOAD CURRENT LIMIT VS TEMPERATURE
Permanent current
Ie (ADC)
40
Power dissipated
(W)
WF042000
35.9
WF032000
35
27.5
30
20.2
25
14
20
8.96
15
5.04
10
2.24
0.56
5
No heatsink
SKH Option
0
0
10
20
30
40
50
60
70
80
90
100
0
110
Ambient temperature (°C)
Fig. 8
CURRENT OVERLOAD CHARACTERISTIC (ITSM)
Not available
celduc®
r
e
l
a
i
S/INT/XKLD31006/A/13/01/09
s
PRELIMINARY
Page 5/5 UK
DIMENSIONS AND ACCESSORIES
DIMENSIONS
76,4±0,4
Fig. 9
±0,4
29
±0,2
12,2
53 ±0,4
Fig.
10
ACCESSORIES
celduc®
r
e
l
a
i
s
www.celduc.com
5, rue Ampère B.P. 30004