The 22,5mm pitch SSR solution ! ® All technical charateristics are subject to change without previous notice - PLAQCELPAC2UK - September 2014 Accessories for celpac SA • Transparent protective cover • For mounting on your heatsink or panel mount SA8 : Designed for most types of loads Integrated VDR protection SA9 : Typical applications : resistive loads AC-51 Reference Thyristor rating Switching voltage V peak (V) Control voltage I²t Removable protection flaps (for SA and SU ranges) Standard for SU range Ref : 1K523000 Dimensions mm SA842070 25A 12-275VAC 600V 3-32VDC 600A²s SA941460 12A 12-280VAC 600V 3-32VDC 128A²s SA942460 25A 12-280VAC 600V 3-32VDC 450A²s SA945460 50A 12-280VAC 600V 3-32VDC 1680A²s SA963460 35A 24-600VAC 1200V 3,5-32VDC 882A²s SA965460 50A 24-600VAC 1200V 3,5-32VDC 1680A²s Protection cover (standard for SA range) Ref : 1K522000 22,5 x 90 x 42 Solid State Relays & Contactors celpac ® The 22,5mm pitch SSR solution ! Marking labels to be mounted on protection flaps or cover. Ref : 1MZ09000 MADE IN FRANCE SAL/SAM • Transparent protective cover • "Ready to use" on 22,5 and 45mm heatsinks SA9 : Typical applications : resistive loads AC-51 Removable connectors (screw terminals, spring terminals) Reference Thyristor rating Max. switching current at 25°C Switching voltage V peak (V) 12-280VAC 600V 3-32VDC 128A²s 600V 3-32VDC 450A²s SAL941460 12A 12A SAL942460 25A 23A 12-280VAC SAxx1xx 24-600VAC SUxx1xx SAxx2xx 1200V SUxx2xx SALxx1xxx 26-600VAC SULxx1xxx SALxx2xxx 1200V SULxx2xxx SAL963460 35A 30A SAL965460 50A 32A SAM943460 35A 32A Nominal current 12-280VAC 12A 600V 25A 120 250A Itsm (10ms) min current - control current SAL/SAM with low input < 10mA I²t Dimensions mm 3-32VDC 35A 882A²s 882A²s 320 530 -40 24-600VAC /+80°C -401200V /+80°C -40 /+80°C 882A²s-40 /+80°C 6-32VDC temperature 32A SAM963360Storage35A -40/+125°C -40/+125°C 1200V 6-32VDC insulation SAM965360Input / Output 45A 50A 26-600VAC 4000VRMS 1200V 4000VRMS 6-32VDC 882A²s Ref : WF311100 (3K/W) 50A SAL962360 Operati24-60erature 23A 25A and Output / Baseplate 512 6-32VDC A large range of heatsinks 45 x 90 x 112 72 24-600VAC 24-600VAC SAL 22,5 x 90 x 112 SAxx7xxx SAxx5xxx S SUxx7xxx 3,5-32Uxx5xxx SALxx3xxx 1680A²s SALxx5xxx SALxx7xxx 3,5-32VDC SULxx3xxx SULxx5xxx SULxx7xxx SAxx3xxx 3,5-32VDC SUxx3xxx 15A SAL961360 I²t (A24typical) 15A 340 1200V Control voltage 1404 Ref : WF151200 (2,2K/W) Ref : WF112100 (1K/W) Smart Solid State Relays with optional modules SAM 22,5 x 90 x 112 -40/+125°C 882A²s -40/+125°C 45 x 90 x 112 4000VRMS 1680A²s 4000VRMS Our distributor 5, rue Ampère - BP 30004 - 42290 SORBIERS - FRANCE Sales department for France - Tel : +33 (0)4 77 53 90 20 Sales department for Asia - Tel : +33 (0)4 77 53 90 19 Sales department for Europe - Tel : +33 (0)4 77 53 90 21 Sales department for America - Tel : +33 (0)4 77 53 90 19 www.celduc.com Fax : +33 (0)4 77 53 85 51 [email protected] www.celduc-relais.com The 22,5mm pitch SSR solution ! Smart SSR with optional modules Our range of Solid State Relays & Contactors SU Performance & reliability : • Fixing screws compatible with all hockey puck style relays (celduc SO and SC range), • Maximum peak voltage up to 1600V (690VRMS), 600V and 1200V as standard, • Thyristor rating up to 75A, • Large input range : 3-32VDC with regulated current models, • AC input control available, • Input status yellow LED, • Over-voltage protection on input, • New generation of TMS² technology for thyristors for a longer life expectancy, • Quick and easy connections, • Designed according to European standards EN60947-4-3 (IEC9474-3) and EN60950 (VDE0805 reinforced insulation) - IEC62314-UL-cUL, • IP20 protection with removable flaps (SU range) or cover (SA range), • Other protection devices available as an option : RC snubber, VDR, self turn-on. Price-effective and compact solution : • The 22,5 mm pitch of our Solid State contactors reduces space to the minimum, • Reduced assembling time, easy cabling, • Reduced maintenance thanks to a very long life expectancy, • One single screw driver for input and output. Thyristor rating SU765070 50A Switching voltage V peak (V) Control voltage 24-510VAC 1200V 3,5-32VDC 1680A²s SU range 3-32VDC 600A²s SU842070 25A 12-275VAC SU842970 25A 12-275VAC 600V 180-240VAC 600A²s SU865070 50A 24-510VAC 1200V 3,5-32VDC 1680A²s SU865970 50A 24-510VAC 1200V 180-240VAC 1680A²s SU867070 75A 24-510VAC 1200V 3,5-32VDC 7200A²s SU942460 25A 12-280VAC 600V 3-32VDC 600A²s SU963460 35A 24-600VAC 1200V 3,5-32VDC 882A²s SU965460 50A 24-600VAC 1200V 3,5-32VDC 1680A²s SU967460 75A 24-600VAC 1200V 3,5-32VDC 7200A²s Input connections Inputs with pluggable connector ESUC module allows to make a diagnostic up to 5 heating elements in parallel. Dimensions mm Permanent load current monitoring, Current teaching function, Two alarm thresholds (+/-16%), Partial load break detection, Open load detection, Detection of short-circuited SSR. Current range Control Box ESUC0450 2-40A 8-30VDC Power supply ESUC0480 2-40A 24-45VDC 22,5 x 90 x 42 ECOM0010 - Temperature controller PID, current monitor and communication interface in one unit The ECOM is the most compact solution available on the market that puts together the latest measuring and control technology. Pluggable on a celduc® relais SSR type SU and SUL, it can answer the needs of cost reduction of electrical cabinets (smaller), PLC (less analogue and digital I/O's) and wiring (bus communication). SUx7 : designed for motors AC-53 and inductive loads. Also use in phase angle control systems. SUx8 : designed for most types of loads / Integrated VDR protection SUx9 : typical applications : resistive loads AC-51 Reference Thyristor rating Max. switching current at 25°C Switching voltage V peak (V) Control voltage I²t SUL765070 50A 32A 24-510VAC 1200V 3,5-32VDC 1680A²s SUL842070 25A 23A 12-275VAC 600V 3-32VDC 600A²s SUL842770 25A 23A 12-275VAC 600V 18-30VAC/DC 600A²s SUL842970 23A 12-275VAC 600V 160-240VAC 600A²s SUL865070Operati24-60erature 50A 32A 24-510VAC 1200V 3,5-32VDC 1680A²s SUL865770Storage temperature 50A 32A 24-510VAC 1200V 18-30VAC/DC 1680A²s 50A 32A Input / Output insulation SUL867070and Output / Baseplate 24-510VAC 1200V 160-240VAC 1680A²s 35A 24-510VAC 1200V 3,5-32VDC 7200A²s SUL942460 25A 23A 12-280VAC 600V 3-32VDC 600A²s SUL963460 35A 30A 24-600VAC 1200V 3,5-32VDC 882A²s SUL965460 50A 32A 24-600VAC 1200V 3,5-32VDC 1680A²s SUL967460 75A 35A 24-600VAC 1200V 3,5-32VDC 7200A²s SUM865070 50A 45A 24-510VAC 1200V 3,5-32VDC 1680A²s SUM867070 75A 45A 24-510VAC 1200V 3,5-32VDC 7200A²s SUH967460 75A 50A 24-600VAC 1200V 3,5-32VDC 7200A²s Itsm (10ms) min Product Ref. Temperature controller with thermocouple input, loop and heater break alarms, heating and cooling PID autotuning ... • Removable flaps for protection • "Ready to use" on 22,5 and 45mm heatsinks 75A Inputs with screws ESUC - Current monitoring module SUL/SUM/SUH SUL865970 Power connections I²t 600V 25A I²t (A24typical) Quick and easy connections : SA range Reference SU7 : designed for motors AC-53 and inductive loads. Also use in phase angle control systems. SU8 : designed for most types of loads / Integrated VDR protection SU9 : typical applications : resistive loads AC-51 Save room / Save costs / Add more functions ! Current monitoring and alarms up to 50A with current transformer (CT) RS485 communication with MODBUS RTU (others on request) Pluggable module on a 22,5mm pitch SSR Dimensions mm J, K, T, E thermocouples SUL 22,5 x 90 x 112 SUM Auxiliary output for cooling, alarm or 3 phase application control Main features The requirement for enhanced design, ease of installation, optimum life and the most competitive price is delivered by the new generation of celpac products. • Removable flaps for protection • For mounting on your heatsink or panel mount Two modules are available directly pluggable on our SU and SUL Box Module 22,5mm celduc relais SU and SUL ranges Power supply 24Vdc +/- 10% (galvanically isolated from RS485 and input) Sealing IP20 (Box and Terminal blocks) Quick set-up options Software LABSOFTVIEW®(in cooperation with Pixsys) Thermocouple input 1 selectable input TC : K, J, T, E Current Transformer Integrated C.T. with 50A - resolution 0,1A 1 auxiliary output (alarm...) Configurable, 24 Vdc - 50mA max. SUH 45 x 90 x 112 50 x 120 x 118 Serial communication RS485 Modbus RTU - Slave (9600... 115200 Baud) Control algorithms ON-OFF with hysteresis, P., P.I., P.I.D., P.D. time proportioned Tuning Manual or automatic Alarm mode Absolute / Threshold, band, High / Low deviation. Loop Break Alarm function Auto/Man function Output percentage command with automatic change in case of sensor failure Double P.I.D. Heating / Cooling P.I.D. The 22,5mm pitch SSR solution ! Smart SSR with optional modules Our range of Solid State Relays & Contactors SU Performance & reliability : • Fixing screws compatible with all hockey puck style relays (celduc SO and SC range), • Maximum peak voltage up to 1600V (690VRMS), 600V and 1200V as standard, • Thyristor rating up to 75A, • Large input range : 3-32VDC with regulated current models, • AC input control available, • Input status yellow LED, • Over-voltage protection on input, • New generation of TMS² technology for thyristors for a longer life expectancy, • Quick and easy connections, • Designed according to European standards EN60947-4-3 (IEC9474-3) and EN60950 (VDE0805 reinforced insulation) - IEC62314-UL-cUL, • IP20 protection with removable flaps (SU range) or cover (SA range), • Other protection devices available as an option : RC snubber, VDR, self turn-on. Price-effective and compact solution : • The 22,5 mm pitch of our Solid State contactors reduces space to the minimum, • Reduced assembling time, easy cabling, • Reduced maintenance thanks to a very long life expectancy, • One single screw driver for input and output. Thyristor rating SU765070 50A Switching voltage V peak (V) Control voltage 24-510VAC 1200V 3,5-32VDC 1680A²s SU range 3-32VDC 600A²s SU842070 25A 12-275VAC SU842970 25A 12-275VAC 600V 180-240VAC 600A²s SU865070 50A 24-510VAC 1200V 3,5-32VDC 1680A²s SU865970 50A 24-510VAC 1200V 180-240VAC 1680A²s SU867070 75A 24-510VAC 1200V 3,5-32VDC 7200A²s SU942460 25A 12-280VAC 600V 3-32VDC 600A²s SU963460 35A 24-600VAC 1200V 3,5-32VDC 882A²s SU965460 50A 24-600VAC 1200V 3,5-32VDC 1680A²s SU967460 75A 24-600VAC 1200V 3,5-32VDC 7200A²s Input connections Inputs with pluggable connector ESUC module allows to make a diagnostic up to 5 heating elements in parallel. Dimensions mm Permanent load current monitoring, Current teaching function, Two alarm thresholds (+/-16%), Partial load break detection, Open load detection, Detection of short-circuited SSR. Current range Control Box ESUC0450 2-40A 8-30VDC Power supply ESUC0480 2-40A 24-45VDC 22,5 x 90 x 42 ECOM0010 - Temperature controller PID, current monitor and communication interface in one unit The ECOM is the most compact solution available on the market that puts together the latest measuring and control technology. Pluggable on a celduc® relais SSR type SU and SUL, it can answer the needs of cost reduction of electrical cabinets (smaller), PLC (less analogue and digital I/O's) and wiring (bus communication). SUx7 : designed for motors AC-53 and inductive loads. Also use in phase angle control systems. SUx8 : designed for most types of loads / Integrated VDR protection SUx9 : typical applications : resistive loads AC-51 Reference Thyristor rating Max. switching current at 25°C Switching voltage V peak (V) Control voltage I²t SUL765070 50A 32A 24-510VAC 1200V 3,5-32VDC 1680A²s SUL842070 25A 23A 12-275VAC 600V 3-32VDC 600A²s SUL842770 25A 23A 12-275VAC 600V 18-30VAC/DC 600A²s SUL842970 23A 12-275VAC 600V 160-240VAC 600A²s SUL865070Operati24-60erature 50A 32A 24-510VAC 1200V 3,5-32VDC 1680A²s SUL865770Storage temperature 50A 32A 24-510VAC 1200V 18-30VAC/DC 1680A²s 50A 32A Input / Output insulation SUL867070and Output / Baseplate 24-510VAC 1200V 160-240VAC 1680A²s 35A 24-510VAC 1200V 3,5-32VDC 7200A²s SUL942460 25A 23A 12-280VAC 600V 3-32VDC 600A²s SUL963460 35A 30A 24-600VAC 1200V 3,5-32VDC 882A²s SUL965460 50A 32A 24-600VAC 1200V 3,5-32VDC 1680A²s SUL967460 75A 35A 24-600VAC 1200V 3,5-32VDC 7200A²s SUM865070 50A 45A 24-510VAC 1200V 3,5-32VDC 1680A²s SUM867070 75A 45A 24-510VAC 1200V 3,5-32VDC 7200A²s SUH967460 75A 50A 24-600VAC 1200V 3,5-32VDC 7200A²s Itsm (10ms) min Product Ref. Temperature controller with thermocouple input, loop and heater break alarms, heating and cooling PID autotuning ... • Removable flaps for protection • "Ready to use" on 22,5 and 45mm heatsinks 75A Inputs with screws ESUC - Current monitoring module SUL/SUM/SUH SUL865970 Power connections I²t 600V 25A I²t (A24typical) Quick and easy connections : SA range Reference SU7 : designed for motors AC-53 and inductive loads. Also use in phase angle control systems. SU8 : designed for most types of loads / Integrated VDR protection SU9 : typical applications : resistive loads AC-51 Save room / Save costs / Add more functions ! Current monitoring and alarms up to 50A with current transformer (CT) RS485 communication with MODBUS RTU (others on request) Pluggable module on a 22,5mm pitch SSR Dimensions mm J, K, T, E thermocouples SUL 22,5 x 90 x 112 SUM Auxiliary output for cooling, alarm or 3 phase application control Main features The requirement for enhanced design, ease of installation, optimum life and the most competitive price is delivered by the new generation of celpac products. • Removable flaps for protection • For mounting on your heatsink or panel mount Two modules are available directly pluggable on our SU and SUL Box Module 22,5mm celduc relais SU and SUL ranges Power supply 24Vdc +/- 10% (galvanically isolated from RS485 and input) Sealing IP20 (Box and Terminal blocks) Quick set-up options Software LABSOFTVIEW®(in cooperation with Pixsys) Thermocouple input 1 selectable input TC : K, J, T, E Current Transformer Integrated C.T. with 50A - resolution 0,1A 1 auxiliary output (alarm...) Configurable, 24 Vdc - 50mA max. SUH 45 x 90 x 112 50 x 120 x 118 Serial communication RS485 Modbus RTU - Slave (9600... 115200 Baud) Control algorithms ON-OFF with hysteresis, P., P.I., P.I.D., P.D. time proportioned Tuning Manual or automatic Alarm mode Absolute / Threshold, band, High / Low deviation. Loop Break Alarm function Auto/Man function Output percentage command with automatic change in case of sensor failure Double P.I.D. Heating / Cooling P.I.D. The 22,5mm pitch SSR solution ! ® All technical charateristics are subject to change without previous notice - PLAQCELPAC2UK - September 2014 Accessories for celpac SA • Transparent protective cover • For mounting on your heatsink or panel mount SA8 : Designed for most types of loads Integrated VDR protection SA9 : Typical applications : resistive loads AC-51 Reference Thyristor rating Switching voltage V peak (V) Control voltage I²t Removable protection flaps (for SA and SU ranges) Standard for SU range Ref : 1K523000 Dimensions mm SA842070 25A 12-275VAC 600V 3-32VDC 600A²s SA941460 12A 12-280VAC 600V 3-32VDC 128A²s SA942460 25A 12-280VAC 600V 3-32VDC 450A²s SA945460 50A 12-280VAC 600V 3-32VDC 1680A²s SA963460 35A 24-600VAC 1200V 3,5-32VDC 882A²s SA965460 50A 24-600VAC 1200V 3,5-32VDC 1680A²s Protection cover (standard for SA range) Ref : 1K522000 22,5 x 90 x 42 Solid State Relays & Contactors celpac ® The 22,5mm pitch SSR solution ! Marking labels to be mounted on protection flaps or cover. Ref : 1MZ09000 MADE IN FRANCE SAL/SAM • Transparent protective cover • "Ready to use" on 22,5 and 45mm heatsinks SA9 : Typical applications : resistive loads AC-51 Removable connectors (screw terminals, spring terminals) Reference Thyristor rating Max. switching current at 25°C Switching voltage V peak (V) 12-280VAC 600V 3-32VDC 128A²s 600V 3-32VDC 450A²s SAL941460 12A 12A SAL942460 25A 23A 12-280VAC SAxx1xx 24-600VAC SUxx1xx SAxx2xx 1200V SUxx2xx SALxx1xxx 26-600VAC SULxx1xxx SALxx2xxx 1200V SULxx2xxx SAL963460 35A 30A SAL965460 50A 32A SAM943460 35A 32A Nominal current 12-280VAC 12A 600V 25A 120 250A Itsm (10ms) min current - control current SAL/SAM with low input < 10mA I²t Dimensions mm 3-32VDC 35A 882A²s 882A²s 320 530 -40 24-600VAC /+80°C -401200V /+80°C -40 /+80°C 882A²s-40 /+80°C 6-32VDC temperature 32A SAM963360Storage35A -40/+125°C -40/+125°C 1200V 6-32VDC insulation SAM965360Input / Output 45A 50A 26-600VAC 4000VRMS 1200V 4000VRMS 6-32VDC 882A²s Ref : WF311100 (3K/W) 50A SAL962360 Operati24-60erature 23A 25A and Output / Baseplate 512 6-32VDC A large range of heatsinks 45 x 90 x 112 72 24-600VAC 24-600VAC SAL 22,5 x 90 x 112 SAxx7xxx SAxx5xxx S SUxx7xxx 3,5-32Uxx5xxx SALxx3xxx 1680A²s SALxx5xxx SALxx7xxx 3,5-32VDC SULxx3xxx SULxx5xxx SULxx7xxx SAxx3xxx 3,5-32VDC SUxx3xxx 15A SAL961360 I²t (A24typical) 15A 340 1200V Control voltage 1404 Ref : WF151200 (2,2K/W) Ref : WF112100 (1K/W) Smart Solid State Relays with optional modules SAM 22,5 x 90 x 112 -40/+125°C 882A²s -40/+125°C 45 x 90 x 112 4000VRMS 1680A²s 4000VRMS Our distributor 5, rue Ampère - BP 30004 - 42290 SORBIERS - FRANCE Sales department for France - Tel : +33 (0)4 77 53 90 20 Sales department for Asia - Tel : +33 (0)4 77 53 90 19 Sales department for Europe - Tel : +33 (0)4 77 53 90 21 Sales department for America - Tel : +33 (0)4 77 53 90 19 www.celduc.com Fax : +33 (0)4 77 53 85 51 [email protected] www.celduc-relais.com The 22,5mm pitch SSR solution ! ® All technical charateristics are subject to change without previous notice - PLAQCELPAC2UK - September 2014 Accessories for celpac SA • Transparent protective cover • For mounting on your heatsink or panel mount SA8 : Designed for most types of loads Integrated VDR protection SA9 : Typical applications : resistive loads AC-51 Reference Thyristor rating Switching voltage V peak (V) Control voltage I²t Removable protection flaps (for SA and SU ranges) Standard for SU range Ref : 1K523000 Dimensions mm SA842070 25A 12-275VAC 600V 3-32VDC 600A²s SA941460 12A 12-280VAC 600V 3-32VDC 128A²s SA942460 25A 12-280VAC 600V 3-32VDC 450A²s SA945460 50A 12-280VAC 600V 3-32VDC 1680A²s SA963460 35A 24-600VAC 1200V 3,5-32VDC 882A²s SA965460 50A 24-600VAC 1200V 3,5-32VDC 1680A²s Protection cover (standard for SA range) Ref : 1K522000 22,5 x 90 x 42 Solid State Relays & Contactors celpac ® The 22,5mm pitch SSR solution ! Marking labels to be mounted on protection flaps or cover. Ref : 1MZ09000 MADE IN FRANCE SAL/SAM • Transparent protective cover • "Ready to use" on 22,5 and 45mm heatsinks SA9 : Typical applications : resistive loads AC-51 Removable connectors (screw terminals, spring terminals) Reference Thyristor rating Max. switching current at 25°C Switching voltage V peak (V) 12-280VAC 600V 3-32VDC 128A²s 600V 3-32VDC 450A²s SAL941460 12A 12A SAL942460 25A 23A 12-280VAC SAxx1xx 24-600VAC SUxx1xx SAxx2xx 1200V SUxx2xx SALxx1xxx 26-600VAC SULxx1xxx SALxx2xxx 1200V SULxx2xxx SAL963460 35A 30A SAL965460 50A 32A SAM943460 35A 32A Nominal current 12-280VAC 12A 600V 25A 120 250A Itsm (10ms) min current - control current SAL/SAM with low input < 10mA I²t Dimensions mm 3-32VDC 35A 882A²s 882A²s 320 530 -40 24-600VAC /+80°C -401200V /+80°C -40 /+80°C 882A²s-40 /+80°C 6-32VDC temperature 32A SAM963360Storage35A -40/+125°C -40/+125°C 1200V 6-32VDC insulation SAM965360Input / Output 45A 50A 26-600VAC 4000VRMS 1200V 4000VRMS 6-32VDC 882A²s Ref : WF311100 (3K/W) 50A SAL962360 Operati24-60erature 23A 25A and Output / Baseplate 512 6-32VDC A large range of heatsinks 45 x 90 x 112 72 24-600VAC 24-600VAC SAL 22,5 x 90 x 112 SAxx7xxx SAxx5xxx S SUxx7xxx 3,5-32Uxx5xxx SALxx3xxx 1680A²s SALxx5xxx SALxx7xxx 3,5-32VDC SULxx3xxx SULxx5xxx SULxx7xxx SAxx3xxx 3,5-32VDC SUxx3xxx 15A SAL961360 I²t (A24typical) 15A 340 1200V Control voltage 1404 Ref : WF151200 (2,2K/W) Ref : WF112100 (1K/W) Smart Solid State Relays with optional modules SAM 22,5 x 90 x 112 -40/+125°C 882A²s -40/+125°C 45 x 90 x 112 4000VRMS 1680A²s 4000VRMS Our distributor 5, rue Ampère - BP 30004 - 42290 SORBIERS - FRANCE Sales department for France - Tel : +33 (0)4 77 53 90 20 Sales department for Asia - Tel : +33 (0)4 77 53 90 19 Sales department for Europe - Tel : +33 (0)4 77 53 90 21 Sales department for America - Tel : +33 (0)4 77 53 90 19 www.celduc.com Fax : +33 (0)4 77 53 85 51 [email protected] www.celduc-relais.com