SO9
SO7
SO8
SOR
SOD
Charges résistives
Resistive loads
Asynchrones
Random
Universel
Most of loads
Connectique ressort
Spring terminals
Diagnostic
Diagnostic
Tension de sortie / Output voltage :
SOx4xxxx : 600Vpeak (typical RMS voltage 24-48-100-110-127-200-220-230-240 and 280VAC )
SOx5xxxx : 800Vpeak (only on request for 380 /400 VRMS)
SOx6xxxx : 1200Vpeak (typical RMS voltage 380 - 400 -440 -480VRMS )
SOx8 xxxx: 1600Vpeak (typical RMS voltage 600 -690 VRMS )
Courant de sortie / Output current :
SOxx1xxx : 12A
SOxx2xxx : 25A
SOxx3xxx: 35A
SOxx4xxx: 40A (only on request)
SOxx5xxx : 50A
SOxx7xxx : 75A
SOxx8xxx : 95A
SOxx9xxx : 125A

Proud to serve you
All technical caracteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
celduc
r
e
l
a
i
s
okpac
S/MON/options/B/01/03/2005
page 2 / 2F/GB
Commande / Control :
SOxxx0xx : 3-32VDC or 3,5-32VDC with current regulator and high immunity optocoupler
SOxxx1xx : 4-30VDC or 5-30VDC with input resistance and high immunity optocoupler
SOxxx4xx : 3-32VDC or 3,5-32VDC with current regulator and standard optocoupler
SOxxx5xx : 7-30VDC or 8-30VDC with input resistance and standard optocoupler
SOxxx9xx : 20-265VAC/DC control
Options / Options :
SOxxxx0x : No option
SOxxxx1x : only RC snubber on output
SOxxxx2x : only VDR on output
SOxxxx3x : Transil on thyristors gate (autoprotection ) : only on request
SOxxxx4x : LED on input + Transil on thyristors gate (autoprotection ) : only on request
SOxxxx5x : RC snubber + VDR on output
SOxxxx6x : LED on input
SOxxxx7x : LED on input + VDR on output
SOxxxx8x : LED on input + RC on output
SOxxxx9x : LED on input + RC and VDR on output
Autres / Others :
SOxxxxx0 : standard model
SOxxxxx4 : 4Kvolts isolation (VDE) only for 12 and 25A
Volets /Flaps
1K453000 = Référence d'un volet sans le montage
Flap reference without mounting
1LK00500 = 1 volet (côté puissance) + 1 montage celduc
1 flap (on output) + 1 celduc mounting
1LK00600 = 2 volets (puissance & commande) + montages celduc
2 flaps (input & output) + 2 celduc mounting
Interface thermique/ Thermal pad :
FASTONS /FASTON terminals
Standard : 5TH21000 ou
Précollé sur la semelle du relais
Standard model : 5TH21000 or
With adhesive on the SSRs base
1L587000

celduc
r
e
l
a
i
www.celduc.com
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19