okpac S/MON/options/B/01/03/2005 page 1 / 2F/GB Références et options relais okpac okpac references, and options SO9 SO7 SO8 SOR SOD Charges résistives Resistive loads Asynchrones Random Universel Most of loads Connectique ressort Spring terminals Diagnostic Diagnostic Tension de sortie / Output voltage : SOx4xxxx : 600Vpeak (typical RMS voltage 24-48-100-110-127-200-220-230-240 and 280VAC ) SOx5xxxx : 800Vpeak (only on request for 380 /400 VRMS) SOx6xxxx : 1200Vpeak (typical RMS voltage 380 - 400 -440 -480VRMS ) SOx8 xxxx: 1600Vpeak (typical RMS voltage 600 -690 VRMS ) Courant de sortie / Output current : SOxx1xxx : 12A SOxx2xxx : 25A SOxx3xxx: 35A SOxx4xxx: 40A (only on request) SOxx5xxx : 50A SOxx7xxx : 75A SOxx8xxx : 95A SOxx9xxx : 125A Proud to serve you All technical caracteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis. celduc r e l a i s okpac S/MON/options/B/01/03/2005 page 2 / 2F/GB Commande / Control : SOxxx0xx : 3-32VDC or 3,5-32VDC with current regulator and high immunity optocoupler SOxxx1xx : 4-30VDC or 5-30VDC with input resistance and high immunity optocoupler SOxxx4xx : 3-32VDC or 3,5-32VDC with current regulator and standard optocoupler SOxxx5xx : 7-30VDC or 8-30VDC with input resistance and standard optocoupler SOxxx9xx : 20-265VAC/DC control Options / Options : SOxxxx0x : No option SOxxxx1x : only RC snubber on output SOxxxx2x : only VDR on output SOxxxx3x : Transil on thyristors gate (autoprotection ) : only on request SOxxxx4x : LED on input + Transil on thyristors gate (autoprotection ) : only on request SOxxxx5x : RC snubber + VDR on output SOxxxx6x : LED on input SOxxxx7x : LED on input + VDR on output SOxxxx8x : LED on input + RC on output SOxxxx9x : LED on input + RC and VDR on output Autres / Others : SOxxxxx0 : standard model SOxxxxx4 : 4Kvolts isolation (VDE) only for 12 and 25A Volets /Flaps 1K453000 = Référence d'un volet sans le montage Flap reference without mounting 1LK00500 = 1 volet (côté puissance) + 1 montage celduc 1 flap (on output) + 1 celduc mounting 1LK00600 = 2 volets (puissance & commande) + montages celduc 2 flaps (input & output) + 2 celduc mounting Interface thermique/ Thermal pad : FASTONS /FASTON terminals Standard : 5TH21000 ou Précollé sur la semelle du relais Standard model : 5TH21000 or With adhesive on the SSRs base 1L587000 celduc r e l a i www.celduc.com s Rue Ampère B.P. 4 42290 SORBIERS - FRANCE E-Mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19