p072.

RA-C6SERIES
SURGE ABSORBER
φ7 max
●RA-C6 Series
Featuring fast response time and large surge
withstand capability of 2,000A, the RA-C6 is designed
for the protection of electronic components in
electronic circuit from impulse type breakdown
voltage.
Outside dimension
φ0.45"Dumet" wire leads
"Glicoat" -processed
15 max
25 max
Unit:mm
Application
Features
ANT
・Fast response time
・The device will fail open if the surge withstand
capability is exceeded.
・Inter-terminal capacity is extremely small, resulting
in little influence on electronic circuits.
・Dark ambience has no effect on response time.
・Taping type available
Receiver
Surge waveform
1.2/50μs
10kV
V−T Characteristics
(kv)
1.2/50μS
10kV
1.2/50μS
5kV 10/700μS
3kV
3
2kV/diV.
4
1μs/diV
RA-102M-C6
100/1000μS
3kV
Absorbed surge waveform
2
RA-152P-C6
1
RA-102P-C6
RA-601P-C6
Vf 010ns 100ns 1μs 10μs 100μs 1ms
Response time
10ms 100ms
1s
10s
100s
2kV/diV.
Transient sparkover voltage
5
(T)
●RA−C6 Series
Safety Agency:Standard
CSA
UL
UL
UL
C22.2
1414
497B
1449
NO.1
○
−
−
−
○
−
−
−
○
−
−
−
○
−
−
−
○
○
−
−
○
○
−
−
○
○
−
−
○
○
−
−
RA-800P/M-C6
RA-151P/M-C6
RA-201P/M-C6
RA-231P/M-C6
RA-311P/M-C6
RA-351P/M-C6
RA-391P/M-C6
RA-501P/M-C6
DC
spark-over
Voltage
(V)
80(64∼96)
150(120∼180)
200(160∼240)
230(184∼276)
310(264∼356)
350(280∼420)
390(312∼468)
500(400∼600)
Type
InsuIation
Capacitance
Resistance 1kHz-1.5V(pF)
(MΩ)
1000Min.
(DC50V)
Peak Surge Impulse
Current
life test
8/20μs
8/20μs
(A)
100A
1000Min.
(DC100V)
1.0Max.
−
○
−
−
RA601P/M-C6
600(480∼720)
1000Min.
(DC500V)
−
−
−
−
○
○
○
○
−
−
○
○
−
−
○
○
RA-102P/M-C6
RA-152P/M-C6
RA-272M-C6
RA-302M-C6
1000(800∼1200)
1500(1200∼1800)
2700(2160∼3240)
3000(2400∼3600)
1000Min
(DC500V)
72
1μs/diV
2000
300
Times
Withstand
Voltage
Test
−
AC1250V 3sec.
AC1500V 60sec.
RA-C6SERIES
SURGE ABSORBER
●Taping type(RA−○○○P−C6−Y)
Description
Outside dimention
15max
Lamp diameter
A
φ6.1max
Lead diameter
d
φ0.45±0.05
Product's height from board
L1
17max
Lamp pitch
P
12.7±1
Hole pitch
P0
12.7±0.3(Note)
P1
3.85±0.7
P2
6.35±1.3
F
5± 0.6
0.2
Hole position
Pitch between leads
Declining
Outside dimention
Dimension
L
RA
●Forming type(RA−○○○P−C6−F)
Symbol
Height
h
±2
Paper width
W
18±0.5
Hole position
W1
9±0.5
Lead clinch height
H0
16±0.5
Product height
H1
33.5max
Lead length
H
18.5max
Hole diameter
D0
φ4±0.2
t
0.7±0.2
Paper thickness
SURGE ABSORBERS
Note)Accumulative pitch error : 4 pitches 50.8 ±0.6mm,
20 pitches 254±1.5mm.
■See the following for specification of voltage markings
(Example)
Model ………………………………………RA−311M−C6
DC discharge spark-over voltage …………310V
Tolerance ……………………………………±15%→M
Calendar ……………………………………1995→5
Month manufactured ………………………January→A
Outside style
①・②×10③
①・②・③・・・Clamp voltage
④・・・・・・Tolerance±20%(Simbol 0)
⑤・・・・・・The last digit of calendar year Example)1995 → 5
⑥・・・・・・Month manufactured(See table below)
Month 1
Symbol A
2
B
3
D
4
E
5
F
6
G
7
H
8
J
9
K
10
L
11
M
12
N
Color shown by symbol : White
73