SUP-BR-E/SUP-CG-ESERIES NOISE FILTERS SUP-B□R-E SUP-C□G-E UL Safety Approvals : UL-1283 File No . E78644 ●P.C.B. mounting with wire leads ●High Attenuation in MF and HF bands ●Case material rated UL94-VO ●Compact size SUP-B□R-E SUP-C□G-E Rated voltage Safety Standard 250VAC Model number Rated current (A) SUP-B2R-E 2 SUP-B4R-E 4 SUP-B6R-E 6 SUP-C3G-E 3 SUP-C6G-E 6 Test voltage Insulation resistance Line to Line 1000 Vrms 50/60Hz 60sec Line to Line 1000 MΩmin Line to Ground 1500 Vrms 50/60Hz 60sec Line to Ground 1000 MΩmin (at 500VDC) 110 Leakage current (max.) Voltage drop (max.) Temperature rise (max.) Operating temp range (℃) 1.0mA (at 250Vrms 60Hz) 1.0Vrms 20 ℃ −20 to+65 0.6Vrms 30 ℃ −20 to+55 SUP-BR-E/SUP-CG-ESERIES NOISE FILTERS MECHANICAL DIMENSIONS All Dimentions in mm SUP-B□R-E SUP-C□G-E Unit : mm DIMENSIONS Outside Dimension (mm) A B H 37.0 29.0 23.0 29.0 22.0 23.5 NOISE FILTERS Model Number SUP-B2R-E SUP-B4R-E SUP-B6R-E SUP-C3G-E SUP-C6G-E 111