SUP-JGSERIES NOISE FILTERS SUP-J□G SUP-J□G-E SUP-J□G-E1 ●Compact size ●IEC input connector ●UL544, Medical and Dental Equipment, rating ●Faston and Solder output terminals SUP-J□G UL UL CSA VDE SEMKO NEMKO DEMKO FIMKO SEV Safety Approvals : UL-1283 : UL-544 * : C22.2, No.8-M1986 : VDE0565-3 : IEC939 1988 : NEK-NE60320-1, IEC9301 : IEC939 1988 : IEC939 1988 : IEC939 1988 File No . E78644 E78644 LR60681/LR102240 10529-4730-1002 9508094, 9116194 P95101263 302917 181256-01 Nr. 95.5 51431 SUP-J□G-E,SUP-J□G-E1 Rated voltage 250VAC Safety Standard Model number Rated current (A) SUP-J3G-0*1 SUP-J3G-2*1 SUP-J3G-E SUP-J3G-E-2 SUP-J3G-E1-0*1 SUP-J3G-E1-2*1 SUP-J6G-0*1 SUP-J6G-2*1 SUP-J6G-E SUP-J6G-E-2 SUP-J6G-E1-0*1 SUP-J6G-E1-2*1 SUP-J10G-0*1 SUP-J10G-2*1 SUP-J10G-E*3 SUP-J10G-E-2*3 SUP-J10G-E1-0*1 SUP-J10G-E1-2*1 SUP-J15G-0*2 SUP-J15G-2*2 SUP-J15G-E SUP-J15G-E-2 SUP-J15G-E1-0*2 SUP-J15G-E1-2*2 *1 Test voltage Insulation resistance Leakage current (max.) Voltage drop (max.) Temperature rise (max.) Operating temp range(℃) 20℃ −25 to+55 45℃ −25 to+40 10μA 3 0.5mA 70μA 10μA 6 10 Line to Line 1000 Vrms 50/60Hz 60sec Line to Ground 2000 Vrms 50/60Hz 60sec Line to Line 3000 MΩmin 0.5mA Line to Ground 6000 MΩmin 70μA (at 500VDC) 0.5mA 0.6Vrms 10μA 70μA 10μA 15 0.5mA 70μA *3 *2 112 SUP-JGSERIES NOISE FILTERS MECHANICAL DIMENSIONS All Dimentions in mm #250 SUP-J□G-0 SUP-J□G-E SUP-J□G-E1-0 NOISE FILTERS SUP-J□G-2 SUP-J□G-E-2 SUP-J□G-E1-2 113