SUP-FH-ERSERIES NOISE FILTERS SUP-F□H-ER(Faston) SUP-F□H-ER-2(Solder) ●IEC input connector ●Bleeder Resistor for shock protection ●Normal and Common Mode Attenuation ●Chassis Sealable UL CSA VDE SEMKO Safety Approvals : UL-1283 : C22.2, No.8-M1986 : VDE0565-3 : SS443 2901 File No . E78644 LR60681 10529-4730-1002 8815052 SUP-F□H MECHANICAL DIMENSIONS All Dimentions in mm SUP-FH-ER Rated voltage Safety Standard SUP-FH-ER-2 250VAC Model number SUP-F3H-ER SUP-F3H-ER-2 SUP-F6H-ER SUP-F6H-ER-2 SUP-F10H-ER SUP-F10H-ER-2 SUP-F15H-ER-2 SUP-F15H-ER-2 Rated current (A) Test voltage 3 Line to Line 1000Vrms 50/60Hz 60sec 6 10 15 Line to Ground 2000Vrms 50/60Hz 60sec Insulation resistance Line to Ground 6000MΩmin (at 500VDC) 126 Leakage current (max.) Voltage drop (max.) 0.5mA (at 250Vrms 60Hz) Temperature rise (max.) Operating temp range(℃) 30℃ −25 to+55 35℃ −25 to+50 1.0Vrms