p126.

SUP-FH-ERSERIES
NOISE FILTERS
SUP-F□H-ER(Faston)
SUP-F□H-ER-2(Solder)
●IEC input connector
●Bleeder Resistor for shock protection
●Normal and Common Mode Attenuation
●Chassis Sealable
UL
CSA
VDE
SEMKO
Safety Approvals
: UL-1283
: C22.2, No.8-M1986
: VDE0565-3
: SS443 2901
File No .
E78644
LR60681
10529-4730-1002
8815052
SUP-F□H
MECHANICAL DIMENSIONS
All Dimentions in mm
SUP-FH-ER
Rated voltage
Safety
Standard
SUP-FH-ER-2
250VAC
Model
number
SUP-F3H-ER
SUP-F3H-ER-2
SUP-F6H-ER
SUP-F6H-ER-2
SUP-F10H-ER
SUP-F10H-ER-2
SUP-F15H-ER-2
SUP-F15H-ER-2
Rated
current
(A)
Test
voltage
3
Line to Line
1000Vrms
50/60Hz 60sec
6
10
15
Line to Ground
2000Vrms
50/60Hz 60sec
Insulation
resistance
Line to Ground
6000MΩmin
(at 500VDC)
126
Leakage
current
(max.)
Voltage
drop
(max.)
0.5mA
(at 250Vrms
60Hz)
Temperature
rise
(max.)
Operating
temp
range(℃)
30℃
−25 to+55
35℃
−25 to+50
1.0Vrms