DataSheet

Solid State Relay Timer
DataSheet
SeriesOneDR Timer
• 6 Amp AC and DC rated output
• Compact size (11mm wide)
• Dual SCR or MOSFET output
• AC/DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) AC output
• Timer status LED indicator
• UL listed, HP rated
• 8 Industry standard fuctions (A/At, B, C, D/Di, H/Ht, L/Li, Ac and Bw)
PRODUCT SELECTION
Control Voltage
AC Output
DC Output
12-24 VAC/DC
90-140 VAC/DC
180-280 VAC/DC
DRTx24D06x
DRTx24B06x
DRTx24A06x
DRTx06D06
AVAILABLE OPTIONS
Operating Voltage
06: 60 VDC
24: 280 VAC
Series
DRT
A
24
Timing Function
A: A/At, Delay on Make
B: Single Shot
C: Delay on Break
H: H/Ht, Interval
L: L/Li, Repeat Cycle
U: Multifunction
(A/At, H/Ht, D/Di,
B, C, Ac & Bw)
Rated Load Current
06: 6 Amps
D
06
Control Voltage
D: 12-24 VAC/DC
AC
A: 180-240 VAC/DC Output
B: 90-140 VAC/DC
Only
R
Switching Type
(24 suffix only)
Blank: Zero Voltage Turn-On
R: Random Turn-On
Required for valid part number
For options only and not required for valid part number
* Not all part number combinations are available.
Contact Crydom Technical Support for information on
the availability of a specific part number.
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage
Transient Overvoltage [Vpk]
Rated Load Current (2)
Rated Load Current {UL508 Motor Controller} (2) [Arms]
Minimum Load Current
Maximum Off-State Leakage Current @ Rated Voltage
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum Surge Current (AC output 1 cycle. DC output 10ms)
Maximum I²t for Fusing [A² sec]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum On-State Resistance (RDS-ON) [Ohms]
HP rating UL 508/IEC60947[HP (KW)]: 240 VAC
IEC 62314 LC-A [FLA]
IEC 62314 LC-B [Kw]
Wire Size min/max (solid/stranded) [AWG/ IEC mm²] (4)
Output Terminal Screw Torque [in lb (Nm)]
Do not forget to visit us at: www.crydom.com
DRTx24
DRTx06
24-280 VAC (47-440Hz)
600
6 Arms
3.6 Arms
150 mArms
0.1 mArms
500
285/300 Apk (50/60Hz)
410/375 (50/60Hz)
1.3
1/3 (0.24)
6A
0.24
22/12 [0.33/3.31]
7.0 (0.8)
1-48 VDC
60 VDC
6A
2.5 mA
0.25 mA
60 A
0.3 VDC
0.034
22/12 [0.33/3.31]
7.0 (0.8)
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Solid State Relay Timer
DataSheet
INPUT SPECIFICATIONS (1)
Description
DRTxxxD06
DRTx24A06
DRTx24B06
Control Voltage Range
Must Turn-Off Voltage
Min Input Current @ Min Voltage (AC/DC) (for on-state)
Maximum Input Current @ Maximum Voltage
Nominal Input Impedance
Wire Size min-max (solid/stranded) [AWG/ IEC mm²] (4)
LED Status Indicator (Color)
Input Terminal Screw Torque [in lb (Nm)]
Maximum turn-on/off time
12-24 VAC/DC
1 VAC/DC
7.6/6.3 mA (5)
12.1/9.1 mA (6)
2K (7)
22-16 / 0.33-1.31
Yes (green)
4.4 (0.5)
See note (9)
180-280 VAC/DC
20 VAC/DC
7.2/7.1 mA
9.7/9.6 mA
25K
22-16 / 0.33-1.31
Yes (green)
4.4 (0.5)
See note (9)
90-140 VAC/DC
10 VAC/DC
7.6/7.4 mA
12.5/12.3 mA
12K
22-16 / 0.33-1.31
Yes (green)
4.4 (0.5)
See note (9)
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Housing Material
Terminal Finish
Humidity
RoHS Exemption #’s
3750 Vrms (8)
109 Ohm
10 pF
-30 to 80 °C
-40 to 125 °C
1.76 oz (50 g)
UL 94 V0 Self-extinguishing
Sulfamate Nickel
5 - 85% Non condensing
5(a), 7(a), 7(c)-I
WIRING DIAGRAM
(+ / )
Load
INPUT
CONTROL
+3/A1
Y1
+1/L1
Status
Indicator
AC Output
TIMER
4/A2
A2
( )
A1
AC/DC CONTROL
VOLTAGE
(Input)
Y1
2/T1
(– / )
( )
(10)
(+ / )
Load
INPUT
CONTROL
+3/A1
Y1
(+)
+1/L1
Status
Indicator
TIMER
4/A2
L1
DC Output
2/T1
(– / )
Do not forget to visit us at: www.crydom.com
(–)
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
AC/DC SUPPLY
(OUTPUT)
d
Load
Loa
T1
Solid State Relay Timer
DataSheet
TIMER SETTINGS & RANGES
Timing Ranges (11)
Timer Settings
Identification
Timing Range
1s
0.1 s to 1 s
10 s
1 s to 10 s
1 min
0.1 min to 1 min
10 min
1 min to 10 min
1h
0.1 h to 1 h
1 2 3
10 h
1 h to 10 h
Fine Adjustment
100 h
10 h to 100 h
Identification
INPUT
STATUS
5 6 7
4
8 9 10
5 6 7
10h100
h
10h100
h
10h100
h
T off
5 6 7
10m1
h
1m
T on
4
1s 10s
1s 10s
8 9 10
1 2 3
AcBw
Function
10m1
h
1m
L
Repeat Cycle
Range
Di
[A/At, H/Ht, D/Di,
B, C, Ac, Bw]
AH
BC
Multifunction
1s 10s
10m1
h
1m
U
Front View
4
Side View
8 9 10
1 2 3
Timing
Function
Fine Adjustment
A
C
Delay on Break
Range
4
10h100
h
B
Single Shot
8 9 10
1 2 3
Interval
1s 10s
10m1
h
1m
H
5 6 7
Delay on Make
Fine Adjustment
Flat side indicates selection
GENERAL NOTES
(1) All parameters at 25°C unless otherwise specified.
(2) See derating curves.
(3) Off-State dv/dt test method per EIA/NARM standard RD-443, paragraph 13.11.1
(4) For UL Listing, must use wire rated @ 75°C.
(5) For DC output model minimum current spec is 15.7/12.4ma (AC/DC).
(6) For DC output model maximum current spec is 27.9/20.3ma (AC/DC).
(7) For DC output mode, spec is 1K.
(8) For DC output model, spec is 2500V.
(9) Activation Time = 65ms / Deactivation Time = 100 ms.
(10) Inductive loads must be diode suppressed to prevent damage to output.
(11) Timing accuracy ± 10%. Additional functions and time ranges are also available,
please contact your local authorized Crydom Distributor, Representative or Crydom
Sales office and request information about our custom products.
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Solid State Relay Timer
DataSheet
MECHANICAL SPECIFICATIONS
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
2.87
[73.0]
0.44
[11.0]
2.02
[51.2]
3.44
[87.3]
4/A2
2/T1
DRTL06D06
3.27
[83.0]
4WB8
S OL I D S TAT E T I M E R
INPUT 12-24 VDC
General Use 60VDC/6Arms
@40°C Ambient Temperature
IND. CONT. EQ
+3/A1
+1/L1
Y1
INPUT
STATUS
1.76
[44.8]
2.59
[65.9]
3.45
[87.7]
THERMAL DERATE INFORMATION
Load Current (Amps)
6
5
4
3
2
1
0
0
10
20
30
40
50
60
70
80
Ambient Temperature (ºC)
Installed single unit, distance to adjacent components ≥ 11 mm
Multiple Units No Spacing
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Solid State Relay Timer
DataSheet
LED STATUS FUNCTION
LED Status by Function
Function
A/At
Delay On Make
H/Ht
Interval
D/Di
Repeat Cycle
Control Voltage
Y1
Timing
Output State
LED Status
Notes
At function is identical to the A function except when Y1 is connected to A1 timing is paused. When Y1 is
removed timing resumes until relay times out. To reset timer remove control power.
Off
Off
Off
Off
On
On
Off
Long Flashes
On
Timed Out
On
On
Off
Off
Off
Off
On
On
On
Long Flashes
On
Timed Out
Off
Short Flashes
Off
Off
Off
Off
A
C
C
At
T
L
On
On/Off
Long Flashes/Short Flashes
L/Li
Off
Off
Off
H
C
C
Ht
T
On
On
On/Off
Long Flashes/Short Flashes
L
B
Single Shot
C
Delay On Break
Ac
Delay On Make /
Delay On Break
Bw
Open
Off
Off
Off
On
Open
Off
Off
Short Flashes
On
Closed
On
On
Long Flashes
On
Closed
Timed Out
Off
Short Flashes
Off
Open
Off
Off
Off
On
Open
Off
Off
Short Flashes
On
Closed
Off
On
On
On
Open
On
On
Long Flashes
Short Flashes
On
Open
Timed Out
Off
Off
Open
Off
Off
Off
On
Open
Off
Off
Short Flashes
On
Closed
On
Off
Long Flashes
On
Closed
Timed Out
On
On
Long Flashes
Short Flashes
On
Open
On
On
On
Open
Timed Out
Off
Off
Open
Off
Off
Off
On
Open
Off
Off
Short Flashes
On
Closed
On
On
Long Flashes
On
Closed
Timed Out
Off
Short Flashes
t2
t3
T=t1+t2+t3
L
To select between on time (Di) first or off time (D) first Y1 is connected. Default is On time (Di) first, for Off
time (D) first connect Y1. Equal On/Off time.
C
D
A1Y1
T
T
T
T
T
Di
T
T
T
T
T
L
To select between on time (Li) first or off time (L) first Y1 is connected A1. Default is On time (Li) first, for Off
time (L) first connect Y1 to A1. Time delay is independent of each other.
L
A1Y1
C
Toff
Ton Toff Ton Toff
Li
Ton
Toff
Ton
Toff
L
L
Off
t1
Y1
C
Repeat Cycle
t3
Ht function is identical to the H function except when Y1 is connected to A1 timing is paused. When Y1 is
removed timing resumes until relay times out. To reset timer remove control power.
L
Off
t2
T=t1+t2+t3
L
C
On
t1
Y1
C
Y1 switch can be momentary or maintained to A1. To
reset timer after relay has timed out Y1 has to be
opened.
B
Y1 switch to A1 must be momentary for timing to
begin. If during timing Y1 is closed again the time
delay is reset and will begin again once Y1 is
removed. Once timed out timer is reset and ready for
the next cycle.
C
To start Delay on Make (A) timing connect Y1 to A1
and maintain until LED is on Solid then to start Delay
on Break (c) portion remove Y1 until relay times out.
Removing Y1 During (A) portion or Connecting Y1
during (c) portion will reset time for that portion.
Ac
Y1 to A1 switch can be momentary or maintained. If
maintained until relay has timed out removing it will
start timing again. If momentary and timers has
timed out reapplying Y1 will start timing again.
Bw
Y1
T
L
C
Y1
T
L
C
Y1
T
T
L
C
Y1
T
T
L
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
IEC 60068-2-6 : Vibration 0.35mm and 0.75mm Amplitutde over 10-55 Hz
IEC 60068-2-27 : Shock 15G/11ms
IEC 61000-4-2 : Electrostatic Discharge Level 3
IEC 61000-4-4 : Electrically Fast Transients Level 3
IEC 61000-4-5 : Electrical Surges Level 3
IND. CONT. EQ.
4WB8
E116949
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
093013
Solid State Relay Timer
DataSheet
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
• Disconnect all
power before
installing or
working with
this equipment.
• Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
• Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
• Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
• Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
• Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
• Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
• Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSI
ONE.
• Spenga tutta
l'alimentazion
e che fornisce
questa
apparecchiatu
ra prima del
lavorare a questa
apparecchiatu ra
存在电击、
爆炸或电弧
闪烁危险
•
在操作此设
备之前请先
关闭电源。
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
• Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima della
rotazione
sull'alimentazi one
L'omissione di
seguire queste
istruz ioni
provocherà la
morte o di
lesioni serie
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
• The product's side panels may be hot, allow
the product to cool before touching.
• Follow proper mounting instructions including
torque values.
• Do not allow liquids or foreign objects to enter
this product.
• Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
• Respecter les consignes de montage, et
notamment les couples de serrage.
• Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
• Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
• Beachten Sie die Montageanweisungen,
• Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Le non-respect de cette directive peut entraîner,
Failure to follow these instructions can result in des lésions corporelles graves ou des
serious injury, or equipment damage.
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
材料损坏和高温外壳的危险性
• Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
• Respetar las instrucciones de montaje, y en
particular los pares de apretado.
• No dejar que penetren líquidos o cuerpos
extraños en el producto.
• I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
• Seguire le istruzioni di montaggio corrette.
• Non far entrare liquidi o oggetti estranei in questo
apparecchio.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
• 产品的一侧面板可能很热,在其冷却前请
不要触碰。
• 遵照正确的安装说明,包括扭矩值。
• 请勿让液体及其他异物进入本产品。
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
Solid State Relay Timer
DataSheet
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr (VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
部件
名称
铅
汞
镉
有毒有害物质或元素
六价铬
多溴联苯
(Pb)
(Hg)
(Cd)
(Cr (VI))
半导体芯片
焊接点
50
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
(PBB)
多溴二苯醚
(PBDE)