Solid State Relay Timer DataSheet SeriesOneDR Timer • 6 Amp AC and DC rated output • Compact size (11mm wide) • Dual SCR or MOSFET output • AC/DC control • Zero-crossing (resistive loads) or random-fire (inductive loads) AC output • Timer status LED indicator • UL listed, HP rated • 8 Industry standard fuctions (A/At, B, C, D/Di, H/Ht, L/Li, Ac and Bw) PRODUCT SELECTION Control Voltage AC Output DC Output 12-24 VAC/DC 90-140 VAC/DC 180-280 VAC/DC DRTx24D06x DRTx24B06x DRTx24A06x DRTx06D06 AVAILABLE OPTIONS Operating Voltage 06: 60 VDC 24: 280 VAC Series DRT A 24 Timing Function A: A/At, Delay on Make B: Single Shot C: Delay on Break H: H/Ht, Interval L: L/Li, Repeat Cycle U: Multifunction (A/At, H/Ht, D/Di, B, C, Ac & Bw) Rated Load Current 06: 6 Amps D 06 Control Voltage D: 12-24 VAC/DC AC A: 180-240 VAC/DC Output B: 90-140 VAC/DC Only R Switching Type (24 suffix only) Blank: Zero Voltage Turn-On R: Random Turn-On Required for valid part number For options only and not required for valid part number * Not all part number combinations are available. Contact Crydom Technical Support for information on the availability of a specific part number. OUTPUT SPECIFICATIONS (1) Description Operating Voltage Transient Overvoltage [Vpk] Rated Load Current (2) Rated Load Current {UL508 Motor Controller} (2) [Arms] Minimum Load Current Maximum Off-State Leakage Current @ Rated Voltage Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3) Maximum Surge Current (AC output 1 cycle. DC output 10ms) Maximum I²t for Fusing [A² sec] Maximum On-State Voltage Drop @ Rated Current [Vpk] Maximum On-State Resistance (RDS-ON) [Ohms] HP rating UL 508/IEC60947[HP (KW)]: 240 VAC IEC 62314 LC-A [FLA] IEC 62314 LC-B [Kw] Wire Size min/max (solid/stranded) [AWG/ IEC mm²] (4) Output Terminal Screw Torque [in lb (Nm)] Do not forget to visit us at: www.crydom.com DRTx24 DRTx06 24-280 VAC (47-440Hz) 600 6 Arms 3.6 Arms 150 mArms 0.1 mArms 500 285/300 Apk (50/60Hz) 410/375 (50/60Hz) 1.3 1/3 (0.24) 6A 0.24 22/12 [0.33/3.31] 7.0 (0.8) 1-48 VDC 60 VDC 6A 2.5 mA 0.25 mA 60 A 0.3 VDC 0.034 22/12 [0.33/3.31] 7.0 (0.8) Copyright © 2013 Crydom Inc. Specifications subject to change without notice. Solid State Relay Timer DataSheet INPUT SPECIFICATIONS (1) Description DRTxxxD06 DRTx24A06 DRTx24B06 Control Voltage Range Must Turn-Off Voltage Min Input Current @ Min Voltage (AC/DC) (for on-state) Maximum Input Current @ Maximum Voltage Nominal Input Impedance Wire Size min-max (solid/stranded) [AWG/ IEC mm²] (4) LED Status Indicator (Color) Input Terminal Screw Torque [in lb (Nm)] Maximum turn-on/off time 12-24 VAC/DC 1 VAC/DC 7.6/6.3 mA (5) 12.1/9.1 mA (6) 2K (7) 22-16 / 0.33-1.31 Yes (green) 4.4 (0.5) See note (9) 180-280 VAC/DC 20 VAC/DC 7.2/7.1 mA 9.7/9.6 mA 25K 22-16 / 0.33-1.31 Yes (green) 4.4 (0.5) See note (9) 90-140 VAC/DC 10 VAC/DC 7.6/7.4 mA 12.5/12.3 mA 12K 22-16 / 0.33-1.31 Yes (green) 4.4 (0.5) See note (9) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Housing Material Terminal Finish Humidity RoHS Exemption #’s 3750 Vrms (8) 109 Ohm 10 pF -30 to 80 °C -40 to 125 °C 1.76 oz (50 g) UL 94 V0 Self-extinguishing Sulfamate Nickel 5 - 85% Non condensing 5(a), 7(a), 7(c)-I WIRING DIAGRAM (+ / ) Load INPUT CONTROL +3/A1 Y1 +1/L1 Status Indicator AC Output TIMER 4/A2 A2 ( ) A1 AC/DC CONTROL VOLTAGE (Input) Y1 2/T1 (– / ) ( ) (10) (+ / ) Load INPUT CONTROL +3/A1 Y1 (+) +1/L1 Status Indicator TIMER 4/A2 L1 DC Output 2/T1 (– / ) Do not forget to visit us at: www.crydom.com (–) Copyright © 2013 Crydom Inc. Specifications subject to change without notice. AC/DC SUPPLY (OUTPUT) d Load Loa T1 Solid State Relay Timer DataSheet TIMER SETTINGS & RANGES Timing Ranges (11) Timer Settings Identification Timing Range 1s 0.1 s to 1 s 10 s 1 s to 10 s 1 min 0.1 min to 1 min 10 min 1 min to 10 min 1h 0.1 h to 1 h 1 2 3 10 h 1 h to 10 h Fine Adjustment 100 h 10 h to 100 h Identification INPUT STATUS 5 6 7 4 8 9 10 5 6 7 10h100 h 10h100 h 10h100 h T off 5 6 7 10m1 h 1m T on 4 1s 10s 1s 10s 8 9 10 1 2 3 AcBw Function 10m1 h 1m L Repeat Cycle Range Di [A/At, H/Ht, D/Di, B, C, Ac, Bw] AH BC Multifunction 1s 10s 10m1 h 1m U Front View 4 Side View 8 9 10 1 2 3 Timing Function Fine Adjustment A C Delay on Break Range 4 10h100 h B Single Shot 8 9 10 1 2 3 Interval 1s 10s 10m1 h 1m H 5 6 7 Delay on Make Fine Adjustment Flat side indicates selection GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) See derating curves. (3) Off-State dv/dt test method per EIA/NARM standard RD-443, paragraph 13.11.1 (4) For UL Listing, must use wire rated @ 75°C. (5) For DC output model minimum current spec is 15.7/12.4ma (AC/DC). (6) For DC output model maximum current spec is 27.9/20.3ma (AC/DC). (7) For DC output mode, spec is 1K. (8) For DC output model, spec is 2500V. (9) Activation Time = 65ms / Deactivation Time = 100 ms. (10) Inductive loads must be diode suppressed to prevent damage to output. (11) Timing accuracy ± 10%. Additional functions and time ranges are also available, please contact your local authorized Crydom Distributor, Representative or Crydom Sales office and request information about our custom products. Do not forget to visit us at: www.crydom.com Copyright © 2013 Crydom Inc. Specifications subject to change without notice. Solid State Relay Timer DataSheet MECHANICAL SPECIFICATIONS Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] 2.87 [73.0] 0.44 [11.0] 2.02 [51.2] 3.44 [87.3] 4/A2 2/T1 DRTL06D06 3.27 [83.0] 4WB8 S OL I D S TAT E T I M E R INPUT 12-24 VDC General Use 60VDC/6Arms @40°C Ambient Temperature IND. CONT. EQ +3/A1 +1/L1 Y1 INPUT STATUS 1.76 [44.8] 2.59 [65.9] 3.45 [87.7] THERMAL DERATE INFORMATION Load Current (Amps) 6 5 4 3 2 1 0 0 10 20 30 40 50 60 70 80 Ambient Temperature (ºC) Installed single unit, distance to adjacent components ≥ 11 mm Multiple Units No Spacing Do not forget to visit us at: www.crydom.com Copyright © 2013 Crydom Inc. Specifications subject to change without notice. Solid State Relay Timer DataSheet LED STATUS FUNCTION LED Status by Function Function A/At Delay On Make H/Ht Interval D/Di Repeat Cycle Control Voltage Y1 Timing Output State LED Status Notes At function is identical to the A function except when Y1 is connected to A1 timing is paused. When Y1 is removed timing resumes until relay times out. To reset timer remove control power. Off Off Off Off On On Off Long Flashes On Timed Out On On Off Off Off Off On On On Long Flashes On Timed Out Off Short Flashes Off Off Off Off A C C At T L On On/Off Long Flashes/Short Flashes L/Li Off Off Off H C C Ht T On On On/Off Long Flashes/Short Flashes L B Single Shot C Delay On Break Ac Delay On Make / Delay On Break Bw Open Off Off Off On Open Off Off Short Flashes On Closed On On Long Flashes On Closed Timed Out Off Short Flashes Off Open Off Off Off On Open Off Off Short Flashes On Closed Off On On On Open On On Long Flashes Short Flashes On Open Timed Out Off Off Open Off Off Off On Open Off Off Short Flashes On Closed On Off Long Flashes On Closed Timed Out On On Long Flashes Short Flashes On Open On On On Open Timed Out Off Off Open Off Off Off On Open Off Off Short Flashes On Closed On On Long Flashes On Closed Timed Out Off Short Flashes t2 t3 T=t1+t2+t3 L To select between on time (Di) first or off time (D) first Y1 is connected. Default is On time (Di) first, for Off time (D) first connect Y1. Equal On/Off time. C D A1Y1 T T T T T Di T T T T T L To select between on time (Li) first or off time (L) first Y1 is connected A1. Default is On time (Li) first, for Off time (L) first connect Y1 to A1. Time delay is independent of each other. L A1Y1 C Toff Ton Toff Ton Toff Li Ton Toff Ton Toff L L Off t1 Y1 C Repeat Cycle t3 Ht function is identical to the H function except when Y1 is connected to A1 timing is paused. When Y1 is removed timing resumes until relay times out. To reset timer remove control power. L Off t2 T=t1+t2+t3 L C On t1 Y1 C Y1 switch can be momentary or maintained to A1. To reset timer after relay has timed out Y1 has to be opened. B Y1 switch to A1 must be momentary for timing to begin. If during timing Y1 is closed again the time delay is reset and will begin again once Y1 is removed. Once timed out timer is reset and ready for the next cycle. C To start Delay on Make (A) timing connect Y1 to A1 and maintain until LED is on Solid then to start Delay on Break (c) portion remove Y1 until relay times out. Removing Y1 During (A) portion or Connecting Y1 during (c) portion will reset time for that portion. Ac Y1 to A1 switch can be momentary or maintained. If maintained until relay has timed out removing it will start timing again. If momentary and timers has timed out reapplying Y1 will start timing again. Bw Y1 T L C Y1 T L C Y1 T T L C Y1 T T L AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 IEC 60068-2-6 : Vibration 0.35mm and 0.75mm Amplitutde over 10-55 Hz IEC 60068-2-27 : Shock 15G/11ms IEC 61000-4-2 : Electrostatic Discharge Level 3 IEC 61000-4-4 : Electrically Fast Transients Level 3 IEC 61000-4-5 : Electrical Surges Level 3 IND. CONT. EQ. 4WB8 E116949 Do not forget to visit us at: www.crydom.com Copyright © 2013 Crydom Inc. Specifications subject to change without notice. 093013 Solid State Relay Timer DataSheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. • Disconnect all power before installing or working with this equipment. • Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. • Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. • Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION • Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil • Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. • Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen • Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSI ONE. • Spenga tutta l'alimentazion e che fornisce questa apparecchiatu ra prima del lavorare a questa apparecchiatu ra 存在电击、 爆炸或电弧 闪烁危险 • 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 • Verificare tutti i collegamenti e sostituire tutte le coperture prima della rotazione sull'alimentazi one L'omissione di seguire queste istruz ioni provocherà la morte o di lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG • The product's side panels may be hot, allow the product to cool before touching. • Follow proper mounting instructions including torque values. • Do not allow liquids or foreign objects to enter this product. • Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher. • Respecter les consignes de montage, et notamment les couples de serrage. • Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. • Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren. • Beachten Sie die Montageanweisungen, • Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Le non-respect de cette directive peut entraîner, Failure to follow these instructions can result in des lésions corporelles graves ou des serious injury, or equipment damage. dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO 材料损坏和高温外壳的危险性 • Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo. • Respetar las instrucciones de montaje, y en particular los pares de apretado. • No dejar que penetren líquidos o cuerpos extraños en el producto. • I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. • Seguire le istruzioni di montaggio corrette. • Non far entrare liquidi o oggetti estranei in questo apparecchio. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright © 2013 Crydom Inc. Specifications subject to change without notice. • 产品的一侧面板可能很热,在其冷却前请 不要触碰。 • 遵照正确的安装说明,包括扭矩值。 • 请勿让液体及其他异物进入本产品。 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 Solid State Relay Timer DataSheet ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr (VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 部件 名称 铅 汞 镉 有毒有害物质或元素 六价铬 多溴联苯 (Pb) (Hg) (Cd) (Cr (VI)) 半导体芯片 焊接点 50 Do not forget to visit us at: www.crydom.com Copyright © 2013 Crydom Inc. Specifications subject to change without notice. (PBB) 多溴二苯醚 (PBDE)