The Global Expert in Solid State Switching Technology ABOUT US Crydom, a brand of Custom Sensors & Technologies (CST) and global expert in Solid State Relay Technology, has a distinguished record of providing high quality, world class Solid State Relay and Control Products for a variety of heating, lighting and motion control applications. Crydom products, coupled with unparalleled technical support, timely delivery and competitive pricing, provide Crydom’s clients with the innovative products and support necessary to succeed in today’s competitive and fast paced global markets. DIN RAIL MOUNTED AC & DC OUTPUT SOLID STATE RELAY TIMERS SeriesOne DR Single Channel AC & DC Output Multifunction Timers Crydom’s proprietary thermal management technology and proven Solid State Relay expertise are now combined with advanced uP based timing in the Crydom’s extensive selection of standard off-the-shelf products is constantly being updated and expanded through its continuous improvement and aggressive new product development programs. Utilizing state of the art designs, materials and technology, Crydom offers a wide range of AC and DC output SSRs and solid state contactors in industry standard Panel Mount, PCB Mount, DIN Rail and Plug-In packages, all meeting global safety and standards agency requirements such as CE, RoHS, UL, IEC, etc. Bolstered by four decades of Solid State Relay operations experience, new SeriesOne DR Timer line. Offering models with exceptional Solid State output ratings of either 6 amp AC or DC and 8 different precision timing functions with 18 variations the new SeriesOne DR Timer line is housed in a compact 11 mm wide DIN Rail mounted package designed for the direct control of a wide variety of resistive and inductive loads. Multifunction Solid State Relay Timing with Superior Output Ratings Ideal for use in control panels for direct control of contactors, solenoids, fully motors, heaters, lights, etc., the SeriesOne DR Timer series is available with custom-designed SSR products for nearly any application where unique either 6 amp/24 to 280 VAC output rating or 6 amp/1 to 60 VDC output rating, specifications and optimized performance are critical for success. both at 40°C ambient temperature…. ratings well in excess of most Solid State Crydom also specializes and encourages adapted and Relay Output Timers in the market today, therefore allowing direct control of Crydom’s modern purpose-built 100,000 square foot manufacturing many loads thus eliminating the need for interfacing power relays often facility houses all aspects of its ISO certified operation including Design required for use with lower power timers. and Development Engineering, Manufacturing Operations and Quality Assurance, Customer Service, Finance, Marketing and General Available timing functions include “A” & “At” delay on make, “B” single shot, Management, permitting close coordination of all aspects of Crydom’s “C” delay on break, “H” & “Ht” interval, “L” & “Li” repeat cycle, and “U” activities. Applications Engineering and Sales support are both performed multifunction that includes A, At, Ac, B, Bw, C, D, Di, H, and Ht functions. Basic in the field to provide Crydom’s Customers with the unparalleled technical timing function selection is user settable via screw slot rotary switches on the and commercial support. side of the SeriesOne DR Timers, while unit and fine timing adjustments are made on the front panel of the Timers. This arrangement provides easy Following rigid design guidelines and standards, Crydom products have access to Technicians for simple timing adjustments but significantly reduces set the bench mark for SSR performance and reliability world wide. In accidental changes to the basic function. addition to award winning designs, Crydom has acquired an impressive list of patents related to SSRs and Solid State Controls, while continuing to develop new circuit and technology-related inventions as part of extensive R&D programs. Versatile Control Control for the SeriesOne DR Timers, depending on model, is 12 to 24 VAC/DC for all models, with options of either 90 to 140 VAC or 180 to 240 VAC To learn more about Crydom SSR technology and products, or how an for AC outputs only. All Crydom SeriesOne DR Timers are UL listed and cUL alliance with Crydom can contribute to the success of your project, visit recognized, UL Motor Control rated, RoHS and China RoHS compliant, and CE www.crydom.com or contact your authorized Crydom Distributor or certified to the Low Voltage and EMC Directives. Crydom Customer Service Representative today. For more information, technical support or questions about adapted assemblies, contact your local Crydom Distributor, Regional Sales Office or www.crydom.com. www.crydom.com SeriesOne DR Timer DIN Rail Mounted AC & DC Output Solid State Relay Timers • • • • • • • • • • Single channel 6 Amps output power rating Compact Size (11 mm wide) 60 VDC & 280 VAC operating voltage ratings 12-24, 90-140 & 180-240 VAC/DC control input options available 8 Industry standard functions (A/At, B, C, D/Di, H/Ht, L/Li, Ac, Bw) IP20 Housing with unique integrated heat sink LED Input/Timer status indicator AC Output versions with Zero Voltage Turn-On for resistive loads and Random Turn-On for inductive loads UL Listed & cUL recognized UL & IEC General Use & Motor Control rated DRTx24x06x DRTx06D06 Operating Voltage Range [Vrms] 24-280 VAC (47-440 Hz) 1-60 VDC Maximum Load Current [Arms] 6 6 Minimum Load Current [Arms] 0.15 2.5 mA Output Specifications (A) 285/300 (B) 1 Cycle Surge Current (50/60 Hz) @ 25ºC [Apk] Maximum Surge Current (10ms) @ 25ºC [Adc] NA 60 (C) NA Maximum On-State Voltage Drop @ Rated Current [Vpk] ≤ 1.3 V ≤ 0.6 VDC Maximum On-State Resistance (RDS-ON) @ 25ºC [Ohms] NA 0.034 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.25 (D) Transient Overvoltage @ 25ºC[Vpk] 600 NA Maximum Operating Voltage NA 1-48 VDC Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] Maximum I²t for Fusing (50/60Hz) @ 25ºC [A² sec] Minimum Power Factor (with Maximum Load) UL 508 Resistive Load [A] (E) 500 NA 410/375 NA 0.5 NA 6 6 1/3 / 3.6 NA IEC 62314 LC-A [FLA] 6 NA IEC 62314 LC-B [Kw] 1.44 NA UL 508 Motor Controller [HP/FLA] (E) DRTx24D06x DRTx24A06x DRTx24B06 DRTx06D06 12-24 180-240 90-140 12-24 Minimum Turn-On Voltage [VAC/DC] 12 180 90 12 Must Turn-Off Voltage [VAC/DC] 1 20 10 1 Minimum Input Current (for On-State) [mA ± 10%] (F) 7.6/6.3 @ 12 VAC/DC 7.2/7.1 @ 180 VAC/DC 7.6/7.4 @ 90 VAC/DC 15.7/12.4 @ 12 VAC/DC Maximum Input Current [mA ± 10%] (F) 12.1/9.1 @ 24 VAC/DC 9.7/9.6 @ 240 VAC/DC 12.5/12.3 @ 140 VAC/DC 27.9/20.3 @24 VAC/DC Input Specifications (A) Control Voltage Range [VAC/DC] Maximum Turn-On Time Per function (G, H) Per function (G, H) Maximum Turn-Off Time DRTx24x06x General Specifications (A) 3750 Dielectric Strength, Input-Output to Baseplate (50/60Hz) [Vrms] Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output [pF] DRTx06D06 109 2500 10 Ambient Operating Temperature Range [ºC] -30 to 80 Ambient Storage Temperature Range [ºC] -40 to125 Status Indicator Display Green (J) Air Gap (Spacing) ratings (Amps) 6 A / 11 mm or 4.5 A / No Spacing Weight (typical) in either [oz] (gr) 1.76 (50) Housing Material Self-extinguishing Terminal Finish Sulfamate Nickel Humidity 5 to 85% General Notes (A) All parameters at 40ºC unless otherwise specified (B) Tj initial: 25ºC, tp: 8.3 ms (C) Output Voltage = 2.5 VDC (D) Output Voltage = 150 V, Control Voltage = 0 V, TJ = 125ºC (E) For UL listing the housing can not exceed 130ºC or the load terminals exceed 105ºC (F) Input current varible ± 10% per function (G) Timing accuracy ± 10% (H) See TABLE 1 and TABLE 2 (J) See TABLE 3 America Tel.: +1 (877) 502 5500 [email protected] To view available Installation Sheet scan the QR code with your smartphone or visit www.crydom.com EMEA Tel.: +44 (0) 1202 606030 [email protected] Asia Pacific Tel.: +86 (0) 21 6065 7725 [email protected] Part Number Nomenclature Series DRT A Wiring Diagram (K) Operating Voltage 06: 60 VDC 24: 280 VAC 24 D Timing Function A: A/At, Delay on Make B: Single Shot C: Delay on Break H: H/Ht, Interval L: L/Li, Repeat Cycle U: Multifunction (A/At, H/Ht, D/Di, B, C, Ac & Bw) A2 Rated Load Current 06: 6 Amps 06 R Control Voltage D: 12-24 VAC/DC AC A: 180-240 VAC/DC Output B: 90-140 VAC/DC Only A1 AC/DC CONTROL VOLTAGE (Input) Y1 Switching Type (24 suffix only) Blank: Zero Voltage Turn-On R: Random Turn-On Required for valid part number For options only and not required for valid part number L1 Block Diagram (+ / ) Load d Load Loa AC/DC SUPPLY (Output) (+ / ) T1 (L) +1/L1 INPUT CONTROL +3/A1 Y1 Mechanical Dimensions Status Indicator Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] AC Output Only TIMER 2.87 [73.0] 4/A2 DC Output Only 0.44 [11.0] 2.02 [51.2] 2/T1 (– / ) Load (L) (– / ) TABLE 1. Timer Settings Identification 3.44 [87.3] INPUT STATUS Side View 5 6 7 4 Di 5 6 7 5 6 7 8 9 10 4 10h100 h 10h100 h 10h100 h T off 4 10m1 h 1m T on Fine Adjustment 1 2 3 1s 10s 8 9 10 4/A2 8 9 10 1 2 3 AcBw Function 1s 10s 10m1 h 1m L Repeat Cycle Range Front View AH BC Multifunction [A/At, H/Ht, D/Di, B, C, Ac, Bw] 10m1 h 1m U 1s 10s 1 2 3 Timing Function 3.27 [83.0] Fine Adjustment 4WB8 S OLI D S TATE TI MER INPUT 12-24 VDC General Use 60VDC/6Arms @40°C Ambient Temperature IND. CONT. EQ +3/A1 A Delay on Make Single Shot Range 5 6 7 4 10h100 h B 8 9 10 1 2 3 Interval Y1 1s 10s 10m1 h 1m H Fine Adjustment C Delay on Break (K) No grounding wire required. DC inductive loads must be diode suppressed (L) Load is allowed in either terminal L1 or terminal T1 Complete specifications of these & other Crydom products available at: www.crydom.com 2/T1 DRTL06D06 INPUT STATUS 1.76 [44.8] 2.59 [65.9] 3.45 [87.7] +1/L1 Derating Curves TABLE 2. Timing Ranges (G) Timing Range 1s 0.1 s to 1 s 10 s 1 s to 10 s 1 min 0.1 min to 1 min 10 min 1 min to 10 min 1h 0.1 h to 1 h 10 h 1 h to 10 h 100 h 10 h to 100 h DRTxxxx06x Single or Multi Unit (M) Multiple Units No Spacing 6 Load Current (Amps) Identification 5 4 3 2 1 0 0 10 20 30 40 50 60 70 80 Ambient Temperature (ºC) TABLE 3. LED Status by Function Function A/At Delay On Make H/Ht Interval Control Voltage Y1 Timing Repeat Cycle LED Status Notes At function is identical to the A function except when Y1 is connected to A1 timing is paused. When Y1 is removed timing resumes until relay times out. To reset timer remove control power. Off Off Off Off On On Off Long Flashes Timed Out On On Off Off Off Off On On On Long Flashes Timed Out Off Off Off A C At T On On/Off H C C Ht T L/Li Off Long Flashes/Short Flashes L On/Off C D A1Y1 T T T T Di T T Single Shot C Delay On Break Ac Delay On Make / Delay On Break Bw T T T T L Long Flashes/Short Flashes L C A1Y1 Toff Li Ton Toff Ton Toff Ton Off Open Off Off Off On Open Off Off Short Flashes On Closed On On Long Flashes Y1 switch can be momentary or maintained to A1. To reset timer after relay has timed out Y1 has to be opened. Closed Timed Out Off Open Off Off Off On Open Off Off Short Flashes On Closed Off On On On Open On On Long Flashes On Open Timed Out Off Short Flashes Off Open Off Off Off On Open Off Off Short Flashes On Closed On Off Long Flashes On Closed Timed Out On On On Open On On Long Flashes On Open Timed Out Off Short Flashes Off Open Off Off Off On Open Off Off Short Flashes On Closed On On Long Flashes On Closed Timed Out Off Short Flashes Ton Toff C B Y1 T L Short Flashes On Off Toff L L B t3 L C On t2 T=t1+t2+t3 To select between on time (Li) first or off time (L) first Y1 is connected A1. Default is On time (Li) first, for Off time (L) first connect Y1 to A1. Time delay is independent of each other. Off Repeat Cycle On t3 To select between on time (Di) first or off time (D) first Y1 is connected. Default is On time (Di) first, for Off time (D) first connect Y1. Equal On/Off time. Off Off t1 Y1 L Off t2 T=t1+t2+t3 L C On t1 Y1 Ht function is identical to the H function except when Y1 is connected to A1 timing is paused. When Y1 is removed timing resumes until relay times out. To reset timer remove control power. Short Flashes Off C L On On D/Di Output State Y1 switch to A1 must be momentary for timing to begin. If during timing Y1 is closed again the time delay is reset and will begin again once Y1 is removed. Once timed out timer is reset and ready for the next cycle. C To start Delay on Make (A) timing connect Y1 to A1 and maintain until LED is on Solid then to start Delay on Break (c) portion remove Y1 until relay times out. Removing Y1 During (A) portion or Connecting Y1 during (c) portion will reset time for that portion. Ac Y1 to A1 switch can be momentary or maintained. If maintained until relay has timed out removing it will start timing again. If momentary and timers has timed out reapplying Y1 will start timing again. Bw C Y1 T L C Y1 T T L C Y1 T T L (M) Minimum spacing between units is 11 mm America Tel.: +1 (877) 502 5500 [email protected] EMEA Tel.: +44 (0) 1202 606030 [email protected] Asia Pacific Tel.: +86 (0) 21 6065 7725 [email protected] AMERICA EUROPE, MIDDLE EAST & AFRICA United States & Canada Crydom Inc 2320 Paseo de las Americas, Suite 201 San Diego, CA 92154 Sales Support: Tel.: +1 (877) 502 5500 Fax: +1 (619) 210 1590 [email protected] Technical Support: Tel.: +1 (877) 702 7700 [email protected] United Kingdom Crydom SSR Ltd Arena Business Centre Holyrood, Close Poole, Dorset BH17 7FJ Sales Support Tel.: +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] Technical Support [email protected] Mexico American Countries CST Latinoamerica Alameda Rio Negro, 1030, 18º andar – Conjunto 1803 CEP: 06454-000 Barueri - São Paulo Brasil Tel.: +55 (11) 2505 7500 Fax: +55 (11) 2505 7507 Austria & Switzerland Italy Tel.: +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] Tel.: +39 (0) 2 665 99 260 Fax: +39 (0) 2 665 99 268 [email protected] Belgium Spain Tel.: +32 (0) 2 460 4413 Fax: +32 (0) 2 461 2614 [email protected] France China & Hong Kong Custom Sensors & Technologies Asia (Shanghai) Ltd. 13th floor Chang Feng International Tower 89 Yunling Road (East) Putuo District Shanghai, 200062 Sales Support Tel.: +86 (0) 21 6065 7725 Fax: +86 (0) 21 6065 7749 [email protected] Technical Support [email protected] Tel.: +34 902 876 217 Fax: +34 902 876 219 [email protected] Netherlands Tel.: +33 (0) 810 123 963 Fax: +33 (0) 810 057 605 [email protected] Tel.: +31 (0) 71 582 0068 Fax: +31 (0) 71 542 1648 [email protected] Germany Middle East, Africa & Other European Countries Tel.: +49 (0) 180 3000 506 Fax: +49 (0) 180 3205 227 [email protected] ASIA PACIFIC Southern & Central Automatismo Crouzet S.A. de C.V. Calzada Zavaleta 2505-C Col Sta Cruz Buenavista C.P. 72150 - Puebla Sales Support: Tel. : +52 (222) 409 7000 Fax : +52 (222) 409 7810 [email protected] South Korea Custom Sensors & Technologies 14F, Kbiz DMC Tower, 189, Seongam-ro, Mapo-gu, Seoul 121-904, South Korea Tel.: +82 2 2629 8312 Fax: +82 2 2629 8310 [email protected] India Tel. : +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] South East Asian & Pacific Countries Custom Sensors & Technologies 2F, No. 39, Ji-Hu Road Nei-Hu Dist. Taipei 114, Taiwan Tel.: +886 2 8751 6388 ext.131 Fax: +886 2 2657 8725 [email protected] [email protected] CST Sensors India Pvt Ltd 4th Floor, Trident Towers, No. 23, 100 Ft- Ashoka Pillar Road, 2nd Block, Jayanagar, Bangalore- 560011 Tel: +91 (80) 4113 2204 /05 Fax: +91 (80) 4113 2206 [email protected] CAT/CR/DRT/EN Distributed by : © 2012 Crydom Inc., All Rights Reserved. Specifications are subject to change without prior notice. Crydom and the Crydom logo are registered trademarks of Crydom Inc. 09/2012 Rev.060713