Datasheet

UPD24D Series
• SIP SSR
• 2 Relays in one package with independent control input
• Ratings per channel of 15A @ 280 VAC
• PCB Mount Package or Panel Mount quick connect terminals (F option)
• SCR output for heavy industrial loads
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
• Low Leakage (snubberless) output
PRODUCT SELECTION
Control Voltage
3-15 VDC
15A
15A
UPD2415D
UPD2415D-10
UPD2415D
UPD2415D-10
24-280
15
150
600
115/120
1.4
1.2
66/60
0.1
500
0.5
24-280
15
150
600
115/120
1.4
1.2
66/60
0.1
500
0.5
UPD2415D
UPD2415D-10
3-15 VDC
3.0 VDC
1.0 VDC
36 mAdc
300 Ohm
1/2 Cycle
1/2 Cycle
3-15 VDC
3.0 VDC
1.0 VDC
36 mAdc
300 Ohm
0.02
1/2 Cycle
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description (Per Channel)
Operating Voltage (47-440Hz) [Vrms]
Maximum Load Current [Arms](3)
Minimum Load Current [mArms]
Transient Overvoltage [Vpk]
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case [°C/W]
Maximum I² t for fusing (50/60Hz, 1/2 cycle) [A² sec]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Minimum Power Factor (with Maximum Load)
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Must Turn On Voltage
Must Turn Off Voltage
Typical Input Current @ 12 VDC
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
2500 Vrms
109 Ohm
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
8 pF
-40 to 80°C
-40 to 125°C
1.44 oz. (40.8g)
GENERAL NOTES
1) All parameters at 25°C and per section unless otherwise specified.
2) Off-state dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Heat sinking required, see following pages for derating curves.
MECHANICAL SPECIFICATIONS
UPD2415D
UPD2415DF
3.08
3.08
1.55
2.80
1.05
0.15
0.15
ASSEMBLED
IN MEXICO
INPUT A
+
-
INPUT B
+
-
OUTPUT B
B2
B1
OUTPUT A
A2
A1
0.40
(3 PLC’S)
WIRING DIAGRAM
ASSEMBLED
IN MEXICO
-
SQ 0.032 ±.005
(8 PLACES)
B1
+B
0.22
0.20
(4 PLC’S)
A1
+A
-
1.12
0.47
SQ PIN .025±.005
.100 CENTERS
(4 PLACES)
0.50
A2
1.23
1.73
1.12
B2
.250 X .032 SQ
FASTON TERMINAL
(4 PLACES)
0.50
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
Rev. 112614
ANNEX - ENVIROMENTAL INFORMATION