UPD24D Series • SIP SSR • 2 Relays in one package with independent control input • Ratings per channel of 15A @ 280 VAC • PCB Mount Package or Panel Mount quick connect terminals (F option) • SCR output for heavy industrial loads • Zero-crossing (resistive loads) or random-fire (inductive loads) output • Low Leakage (snubberless) output PRODUCT SELECTION Control Voltage 3-15 VDC 15A 15A UPD2415D UPD2415D-10 UPD2415D UPD2415D-10 24-280 15 150 600 115/120 1.4 1.2 66/60 0.1 500 0.5 24-280 15 150 600 115/120 1.4 1.2 66/60 0.1 500 0.5 UPD2415D UPD2415D-10 3-15 VDC 3.0 VDC 1.0 VDC 36 mAdc 300 Ohm 1/2 Cycle 1/2 Cycle 3-15 VDC 3.0 VDC 1.0 VDC 36 mAdc 300 Ohm 0.02 1/2 Cycle AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description (Per Channel) Operating Voltage (47-440Hz) [Vrms] Maximum Load Current [Arms](3) Minimum Load Current [mArms] Transient Overvoltage [Vpk] Maximum 1 Cycle Surge Current (50/60Hz) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case [°C/W] Maximum I² t for fusing (50/60Hz, 1/2 cycle) [A² sec] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) Minimum Power Factor (with Maximum Load) INPUT SPECIFICATIONS (1) Description Control Voltage Range Must Turn On Voltage Must Turn Off Voltage Typical Input Current @ 12 VDC Nominal Input Impedance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) 2500 Vrms 109 Ohm Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) 8 pF -40 to 80°C -40 to 125°C 1.44 oz. (40.8g) GENERAL NOTES 1) All parameters at 25°C and per section unless otherwise specified. 2) Off-state dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 3) Heat sinking required, see following pages for derating curves. MECHANICAL SPECIFICATIONS UPD2415D UPD2415DF 3.08 3.08 1.55 2.80 1.05 0.15 0.15 ASSEMBLED IN MEXICO INPUT A + - INPUT B + - OUTPUT B B2 B1 OUTPUT A A2 A1 0.40 (3 PLC’S) WIRING DIAGRAM ASSEMBLED IN MEXICO - SQ 0.032 ±.005 (8 PLACES) B1 +B 0.22 0.20 (4 PLC’S) A1 +A - 1.12 0.47 SQ PIN .025±.005 .100 CENTERS (4 PLACES) 0.50 A2 1.23 1.73 1.12 B2 .250 X .032 SQ FASTON TERMINAL (4 PLACES) 0.50 THERMAL DERATE INFORMATION AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 Rev. 112614 ANNEX - ENVIROMENTAL INFORMATION