RHD8542 - Aeroflex Microelectronic Solutions

Standard Products
Datasheet
RadHard-by-Design
RHD8542 48-Channel Analog Multiplexer
Kelvin Measurement Configured
www.aeroflex.com/RHDseries
May 11, 2015
FEATURES

48 Kelvin measurement channels provided by six 16-channel multiplexers

Single power supply operation at +3.3V to +5V
Radiation performance
- Total dose:
>1Mrad(Si), Dose rate = 50 - 300 rads(Si)/s
- ELDRS Immune
- SEL Immune:
>100 MeV-cm2/mg
- Neutron Displacement Damage:
>1014 neutrons/cm2


Full military temperature range

Low power consumption < 33.6 mW

CMOS analog switching allows rail to rail operation and low switch impedance

One address bus (A0-3) and three enable lines afford flexible organization

Designed for aerospace and high reliability space applications

Packaging – Hermetic ceramic
- 96 leads, 1.320"Sq x 0.200"Ht quad flat pack
- Weight - 15 grams max

Aeroflex Plainview’s Radiation Hardness Assurance Plan is DLA Certified to MIL-PRF-38534, Appendix G.
GENERAL DESCRIPTION
Aeroflex’s RHD8542 is a radiation hardened, single supply, 48-Channel Multiplexer MCM (multi-chip
module). The RHD8542 design uses specific circuit topology and layout methods to mitigate total
ionization dose effects and single event latchup. These characteristics make the RHD8542 especially suited
for the harsh environment encountered in Deep Space missions. It is available in a 96 lead High
Temperature Co-Fired Ceramic (HTCC) Quad Flatpack (CQFP). It is guaranteed operational from -55°C to
+125°C. Available screened in accordance with MIL-PRF-38534 Class K, the RHD8542 is ideal for
demanding military and space applications.
ORGANIZATION AND APPLICATION
The RHD8542 consists of forty-eight (48) Kelvin measurement channels addressable by bus A0~A3 in three
16 channel blocks, each block enabled separately. Each block connects the addressed channel to two
outputs, "Output" and "Current". This technique enables selecting and reading a remote resistive sensor
without the MUX resistance being part of the measurement. For grounded sensors, this is done by passing
current to the sensor by means of the "Current" pin and reading the resultant voltage (proportional to the
sensor resistance) at the "Output" pin.
The device will not latch with SEU events to above 100MeV-cm2/mg. Total dose degradation is minimal to
above 1Mrad(Si). Displacement damage environments to neutron fluence equivalents in the mid 1014
neutrons per cm2 range are readily tolerated. There is no sensitivity to low-dose rate (ELDRS) effects. SEU
effects are application dependent.
SCD8542 Rev A
SCD8542 Rev A 5/11/15
2
Aeroflex Plainview
GND
VCC
A0
A1
A2
A3
EN 16-31
CH 31
•
•
•
CH 16
EN 0-15
CH 15
•
•
•
CH 0
16
16
16
CH 47
•
•
•
CH 32
EN 32-47
CURRENT 16-31
OUTPUT 16-31
OUTPUT 0-15
16
16
RHD8542 48 – CHANNEL ANALOG MUX BLOCK DIAGRAM
MUX 5
MUX 3
MUX 1
16
MUX 6
MUX 4
MUX 2
CURRENT 32-47
OUTPUT 32-47
CURRENT 0-15
ABSOLUTE MAXIMUM RATINGS 1/
Parameter
Range
Units
Case Operating Temperature Range
-55 to +125
°C
Storage Temperature Range
-65 to +150
°C
Supply Voltage
+VCC (Pin 44)
+3.0 to +7.0
V
Digital Input Overvoltage
VEN (Pins 5, 91, 92), VA (Pins 1, 3, 93, 95)
< VCC +0.4
> GND -0.4
V
V
Analog Input Over Voltage
VIN (CH0-CH47)
< VCC +0.4
> GND -0.4
V
Notes:
1/ All measurements are made with respect to ground.
NOTICE: Stresses above those listed under ’Absolute Maximum Ratings’ may cause permanent damage to the device. These are stress rating only;
functional operation beyond the ’Operation Conditions’ is not recommended and extended exposure beyond the ’Operation Conditions’ may affect
device reliability.
RECOMMENDED OPERATING CONDITIONS 1/
Symbol
Typical
Units
Power Supply Voltage
3.3 to 5.0
V
VENL, VAL
Logic Low Level
30% VCC
V
VENH, VAH
Logic High Level
70% VCC
V
+VCC
Parameter
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/
(Tc = -55°C to +125°C, +VCC = +5V - Unless otherwise specified)
Parameter
Supply Current
+VCC
Symbol
Conditions
Units
+ICC
EN = 30% VCC
0
4.8
mA
EN = 70% VCC
0
1.2
mA
IAL(0-3)A
VA = 30% VCC
+25°C
-30
30
nA
+125°C
-300
300
nA
+25°C
-30
30
nA
+125°C
-300
300
nA
+25°C
-10
10
nA
+125°C
-100
100
nA
+25°C
-10
10
nA
+125°C
-100
100
nA
IAH(0-3)A
SCD8542 Rev A 5/11/15
Max
+ISBY
Address Input Current
A(0-3)
Enable Input Current
EN
Min
VA = 70% VCC
IENL(0-15)
IENL(16-31)
IENL(32-47)
VEN(0-15) = 30% VCC
IENH(0-15)
IENH(16-31)
IENH(32-47)
VEN(0-15) = 70% VCC
3
Aeroflex Plainview
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/ (continued)
(Tc = -55°C to +125°C, +VCC = +5V - Unless otherwise specified)
Parameter
Symbol
Conditions
High Input
Leakage Current
(CH0-CH47)
IINLK5
VIN = +5V, VEN =70% VCC,
Output and all unused MUX inputs under test = 0V
Low Input
Leakage Current
(CH0-CH47)
IINLK0
VIN = 0V, VEN =70% VCC,
Output and all unused MUX inputs under test =
+5V
IOUTLK
VOUT = +5V, VEN = 70% VCC,
All inputs grounded except channel being tested.
3/, 4/
Output Leakage Current
VOUT
(pins 25, 68 & 70)
CURRENTS
(pins 26, 67 & 69)
Switch ON Resistance
OUTPUTS
(pins 25, 68 & 70)
CURRENTS
(pins 26, 67 & 69)
VIN = 0V, VIN = +2.5V, VIN = +5V
VEN = 30% VCC
IOUT = -1mA
2/, 3/, 5/, 6/
RDS(ON)
Min
Max
Units
+25°C
-10
10
nA
+125°C
-100
100
nA
+25°C
-10
10
nA
+125°C
-100
100
nA
+25°C
-5
5
nA
+125°C
-50
50
nA
-55°C
-
500

+25°C
-
750

+125°C
-
1000

Notes:
1/ Measure inputs sequentially. Ground all unused inputs of the device under test. VA is the applied input voltage to the address lines A(0-3).
2/ VIN is the applied input voltage to the input channels (CH0-CH47).
3/ VEN is the applied input voltage to the enable lines EN (0-15), EN (16-31) and EN (32-47).
4/ VOUT is the applied input voltage to the output lines OUTPUT(0-15), OUTPUT(16-31) and OUTPUT(32-47), CURRENT(16-31) and
CURRENT(32-47).
5/ Negative current is the current flowing out of each of the MUX pins. Positive current is the current flowing into each MUX pin.
6/ The RHD8542 cannot be operated with analog inputs below 0 volts.
SWITCHING CHARACTERISTICS
(Tc = -55°C to +125°C, +VCC = +5V - Unless otherwise specified)
Parameter
Symbol
tAHL
Conditions
VOUT High to Low Transition
Address to Output Delay
tALH
Enable to Output Delay
tONEN
tOFFEN
SCD8542 Rev A 5/11/15
VOUT Low to High Transition
VEN = 30% VCC (Enabled)
VEN = 70% VCC (Disabled)
4
Temp
Min
Max
Units
-55°C
10
150
ns
+25°C
10
150
ns
+125°C
10
200
ns
-55°C
10
150
ns
+25°C
10
150
ns
+125°C
10
200
ns
-55°C
10
150
ns
+25°C
10
150
ns
+125°C
10
200
ns
ALL
10
200
ns
Aeroflex Plainview
TRUTH TABLE (CH0 – CH15)
TRUTH TABLE (CH16 – CH31)
A3
A2
A1
A0
EN(0-15)
"ON" CHANNEL 1/
A3
A2
A1
A0
EN(16-31)
"ON" CHANNEL 2/
X
X
X
X
H
NONE
X
X
X
X
H
NONE
L
L
L
L
L
CH0
L
L
L
L
L
CH16
L
L
L
H
L
CH1
L
L
L
H
L
CH17
L
L
H
L
L
CH2
L
L
H
L
L
CH18
L
L
H
H
L
CH3
L
L
H
H
L
CH19
L
H
L
L
L
CH4
L
H
L
L
L
CH20
L
H
L
H
L
CH5
L
H
L
H
L
CH21
L
H
H
L
L
CH6
L
H
H
L
L
CH22
L
H
H
H
L
CH7
L
H
H
H
L
CH23
H
L
L
L
L
CH8
H
L
L
L
L
CH24
H
L
L
H
L
CH9
H
L
L
H
L
CH25
H
L
H
L
L
CH10
H
L
H
L
L
CH26
H
L
H
H
L
CH11
H
L
H
H
L
CH27
H
H
L
L
L
CH12
H
H
L
L
L
CH28
H
H
L
H
L
CH13
H
H
L
H
L
CH29
H
H
H
L
L
CH14
H
H
H
L
L
CH30
H
H
H
H
L
CH15
H
H
H
H
L
CH31
1/ Between (CH0-CH15) and OUTPUT(0-15)
2/ Between (CH16-CH31) and OUTPUT2(16-31)
TRUTH TABLE (CH32 – CH47)
A3
A2
A1
A0
EN(32-47)
"ON" CHANNEL 3/
X
X
X
X
H
NONE
L
L
L
L
L
CH32
L
L
L
H
L
CH33
L
L
H
L
L
CH34
L
L
H
H
L
CH35
L
H
L
L
L
CH36
L
H
L
H
L
CH37
L
H
H
L
L
CH38
L
H
H
H
L
CH39
H
L
L
L
L
CH40
H
L
L
H
L
CH41
H
L
H
L
L
CH42
H
L
H
H
L
CH43
H
H
L
L
L
CH44
H
H
L
H
L
CH45
H
H
H
L
L
CH46
H
H
H
H
L
CH47
3/ Between (CH32-CH47) and OUTPUT(32-47)
SCD8542 Rev A 5/11/15
5
Aeroflex Plainview
Address Lines
(A0 - A3)
4.0V
50%
0.8V
3.86V MIN
50%
MUX Output
0V
t AHL
Definition of t AHL
Address Lines
(A0 - A3)
4.0V
50%
0.8V
3.86V MIN
MUX Output
50%
0V
t ALH
Definition of t ALH
4.0V
EN Lines
50%
0.8V
~1V to 4.16V
MUX Output
50%
0V
tONEN
tOFFEN
Definition of tONEN and tOFFEN
NOTE: f = 10KHz, Duty cycle = 50%.
RHD8542 SWITCHING DIAGRAMS
SCD8542 Rev A 5/11/15
6
Aeroflex Plainview
PIN NUMBERS & FUNCTIONS
RHD8542 – 96 Leads Ceramic QUAD Flat Pack
Pin #
Function
Pin #
Function
Pin #
Function
1
A2
33
CH11
65
CH33
2
NC
34
NC
66
CH32
3
A3
35
CH12
67
Output I(32-47)
4
NC
36
NC
68
Output V(32-47)
5
EN 0-15
37
CH13
69
Output I(16-31)
6
NC
38
NC
70
Output V(16-31)
7
CH0
39
CH14
71
GND
8
NC
40
NC
72
GND
9
CH1
41
CH15
73
CH31
10
NC
42
NC
74
CH30
11
CH2
43
NC
75
CH29
12
NC
44
+VCC
76
CH28
13
CH3
45
NC
77
CH27
14
NC
46
NC
78
CH26
15
CH4
47
NC
79
CH25
16
NC
48
NC
80
CH24
17
CH5
49
NC
81
CH23
18
NC
50
CASE GND
82
CH22
19
CH6
51
CH47
83
CH21
20
NC
52
CH46
84
CH20
21
CH7
53
CH45
85
CH19
22
NC
54
CH44
86
CH18
23
GND
55
CH43
87
CH17
24
GND
56
CH42
88
CH16
25
Output V(0-15)
57
CH41
89
GND
26
Output I(0-15)
58
CH40
90
GND
27
CH8
59
CH39
91
EN 32-47
28
NC
60
CH38
92
EN 16-31
29
CH9
61
CH37
93
A0
30
NC
62
CH36
94
NC
31
CH10
63
CH35
95
A1
32
NC
64
CH34
96
NC
NOTE: It is recommended that all "NC" or "no connect" pins be grounded. This eliminates or minimizes any ESD or
static buildup.
SCD8542 Rev A 5/11/15
7
Aeroflex Plainview
ORDERING INFORMATION
Model Number
DLA SMD #
Screening
Package
RHD8542-7
-
Commercial Flow, +25°C testing only
RHD8542-S
-
Military Temperature, -55°C to +125°C
Screened in accordance with the individual Test Methods
of MIL-STD-883 for Space Applications
RHD8542-201-1S
5962-1221001KXC
In accordance with DLA SMD
RHD8542-901-1S
5962H1221001KXC
QUAD
Flat Pack
In accordance with DLA Certified RHA Program Plan to RHA
Level "H", 1Mrads(Si)
1.150 ±.005
(23 Spaces at .050)
Tol Non-Cum
4 Sides
Note: Outside ceramic tie bars
not shown for clarity. Contact
factory for details.
Pin 1
Pin 12
.200
MAX
Pin 85
Pin 84
Pin 13
.0165
±.003
1.320 SQ
MAX
Pin 36
(.400)
Pin 61
Pin 60
Pin 37
.006
±.001
FLAT PACKAGE OUTLINE
EXPORT CONTROL:
This product is controlled for export under the U.S. Department of Commerce (DoC). A license may be required prior to the export
of this product from the United States.
www.aeroflex.com/HiRel
[email protected]
Datasheet Definitions:
Advanced
Preliminary
Datasheet
Product in Development
Shipping Non-Flight Prototypes
Shipping QML and Reduced HiRel
Aeroflex Plainview, Inc. reserves the right to make changes to any products and
services described herein at any time without notice. Consult Aeroflex or an authorized
sales representative to verify that the information in this data sheet is current before
using this product. Aeroflex does not assume any responsibility or liability arising out
of the application or use of any product or service described herein, except as expressly
agreed to in writing by Aeroflex; nor does the purchase, lease, or use of a product or
service from Aeroflex convey a license under any patent rights, copyrights, trademark
rights, or any other of the intellectual rights of Aeroflex or of third parties.
SCD8542 Rev A 5/11/15
8
Our passion for performance is defined by three attributes.
Solution-Minded
Performance-Driven
Customer-Focused