RHD8544 (5/15)

Standard Products
Datasheet
RadHard-by-Design
RHD8544 Dual 16-Channel Analog Multiplexer
www.aeroflex.com/RHDseries
May 14, 2015
FEATURES

32 Channels provided by two independent 16-channel multiplexers

Single power supply operation at +3.3V to +5V
Radiation performance
- Total dose:
>1Mrad(Si), Dose rate = 50 - 300 rads(Si)/s
- ELDRS Immune
- SEL Immune:
>100 MeV-cm2/mg
- Neutron Displacement Damage:
>1014 neutrons/cm2


Full military temperature range

Low power consumption < 11.2mW

CMOS analog switching allows rail to rail operation and low switch impedance

Separate address buses A(0-3) & B(0-3) and enable EN(0-15) & EN(16-31)

Designed for aerospace and high reliability space applications
Packaging – Hermetic ceramic
- 56 leads, 0.800"Sq x 0.200"Ht quad flat pack
- Weight - 6 grams max


Aeroflex Plainview’s Radiation Hardness Assurance Plan is DLA Certified to MIL-PRF-38534, Appendix G.
GENERAL DESCRIPTION
Aeroflex’s RHD8544 is a radiation hardened, single supply, dual 16-Channel Multiplexer MCM (multi-chip
module). The RHD8544 design uses specific circuit topology and layout methods to mitigate total
ionization dose effects and single event latchup. These characteristics make the RHD8544 especially suited
for the harsh environment encountered in Deep Space missions. It is available in a 56 lead High
Temperature Co-Fired Ceramic (HTCC) Quad Flatpack (CQFP). It is guaranteed operational from -55°C to
+125°C. Available screened in accordance with MIL-PRF-38534 Class K, the RHD8544 is ideal for
demanding military and space applications.
ORGANIZATION AND APPLICATION
The RHD8544 consists of two independent 16-channel multiplexers arranged as shown in the block
diagram.
A Section
Sixteen (16) channels addressable by bus A(0-3), enabled by EN(0-15) and outputted on Output1( 0-15).
B Section
Sixteen (16) channels addressable by bus B(0-3), enabled by EN(16-31) and outputted on Output2(16-31).
SCD8544 Rev C
SECTION A
CH 0
16
•
•
•
MUX 1
CH 15
OUTPUT1 (0-15)
EN (0-15)
A0
A1
A2
A3
SECTION B
CH 16
16
•
•
•
MUX 2
CH 31
OUTPUT2 (16-31)
EN (16-31)
B0
B1
B2
B3
+VCC
GND
RHD8544: DUAL 16-CHANNEL ANALOG MUX BLOCK DIAGRAM
SCD8544 Rev C 5/14/15
2
Aeroflex Plainview
ABSOLUTE MAXIMUM RATINGS 1/
Parameter
Range
Units
Case Operating Temperature Range
-55 to +125
°C
Storage Temperature Range
-65 to +150
°C
+7.0
V
Digital Input Over Voltage
VEN0-15 (Pin 13), VEN16-31 (Pin 44), VA (Pins 14, 15, 16, 17), VB (Pins 40, 41, 42, 43)
< VCC +0.4
> GND -0.4
V
V
Analog Input Over Voltage
VIN (CH0-CH31)
< VCC +0.4
> GND -0.4
V
Supply Voltage
+VCC (Pin 18)
Notes:
1/ All measurements are made with respect to ground.
NOTICE: Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress rating
only; functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation Conditions" may
affect device reliability.
RECOMMENDED OPERATING CONDITIONS 1/
Symbol
Typical
Units
Power Supply Voltage
3.3 to 5.0
V
VIL
Low Level Input Voltage
30% VCC
V
VIH
High Level Input Voltage
70% VCC
V
+VCC
Parameter
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/
(Tc = -55°C to +125°C, +VCC = +5V - Unless otherwise specified)
Parameter
Supply Current
+VCC
Symbol
Conditions
Max
Units
+ICC
EN = 30% VCC
0
1.6
mA
+ISBY
EN = 70% VCC
0
400
A
+25°C
-5
5
nA
+125°C
-50
50
nA
+25°C
-5
5
nA
+125°C
-50
50
nA
+25°C
-5
5
nA
+125°C
-50
50
nA
+25°C
-5
5
nA
+125°C
-50
50
nA
+25°C
-5
5
nA
+125°C
-50
50
nA
+25°C
-5
5
nA
+125°C
-50
50
nA
IAL
VA = 30% VCC
Address Input Current
A(0-3), B(0-3)
IAH
IENL
VA = 70% VCC
VEN = 30% VCC
Enable Input Current
EN(0-15), EN(16-31)
IENH
VEN = 70%VCC
High Input
Leakage Current
(CH0-CH31)
IINLK5
VIN = +5V, VEN =70% VCC,
Output and all unused MUX inputs under test
= 0V
Low Input
Leakage Current
(CH0-CH31)
IINLK0
VIN = 0V, VEN =70% VCC
Output and all unused MUX inputs under test
= +5V
SCD8544 Rev C 5/14/15
Min
3
Aeroflex Plainview
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/ (continued)
(Tc = -55°C to +125°C, +VCC = +5V - Unless otherwise specified)
Parameter
Output Leakage Current
VOUT
(pins 12 & 45)
Switch ON Resistance
OUTPUTS
(pins 12 & 45)
Symbol
Conditions
VOUT = +5V, VEN = 70% VCC ,
All inputs grounded except channel being
tested 3/, 4/
IOUTLK
Min
Max
Units
+25°C
-5
5
nA
+125°C
-50
50
nA
-55°C
-
500

+25°C
-
750

+125°C
-
1000

VIN = 0V, VEN = 30% VCC
IOUT = +1mA
RDSON
VIN = +2.5V, VIN = +5V, VEN = 30% VCC
IOUT = -1mA
2/, 3/, 5/, 6/
Notes:
1/ Measure inputs sequentially. Ground all unused inputs of the device under test. VA is the applied input voltage to the address lines A(0-3). VB is
the applied input voltage to the address lines B(0-3).
2/ VIN is the applied input voltage to the input channels (CH0-CH31).
3/ VEN 0-15 is the applied input voltage to the enable line EN (0-15). VEN 16-31 is the applied input voltage to the enable line EN (16-31)
4/ VOUT is the applied input voltage to the output lines OUTPUT1 (0-15), OUTPUT2 (16-31)
5/ Negative current is the current flowing out of each of the MUX pins. Positive current is the current flowing into each MUX pin.
6/ The RHD8544 cannot be operated with analog inputs below 0 volts.
SWITCHING CHARACTERISTICS
(Tc = -55°C to +125°C, +VCC = +5V - Unless otherwise specified)
Parameter
Symbol
tAHL
Conditions
VOUT High to Low Transition
Address to Output Delay
tALH
Enable to Output Delay
SCD8544 Rev C 5/14/15
VOUT Low to High Transition
tONEN
VEN = 30% VCC (Enabled)
tOFFEN
VEN = 70% VCC (Disabled)
4
Temp
Min
Max
Units
-55°C
10
150
ns
+25°C
10
150
ns
+125°C
10
200
ns
-55°C
10
150
ns
+25°C
10
150
ns
+125°C
10
200
ns
-55°C
10
150
ns
+25°C
10
150
ns
+125°C
10
200
ns
ALL
10
200
ns
Aeroflex Plainview
TRUTH TABLE (CH0–CH15)
A3
A2
A1
A0
EN (0-15)
"ON" CHANNEL, 1/ (OUTPUT 1)
X
X
X
X
H
NONE
L
L
L
L
L
CH0
L
L
L
H
L
CH1
L
L
H
L
L
CH2
L
L
H
H
L
CH3
L
H
L
L
L
CH4
L
H
L
H
L
CH5
L
H
H
L
L
CH6
L
H
H
H
L
CH7
H
L
L
L
L
CH8
H
L
L
H
L
CH9
H
L
H
L
L
CH10
H
L
H
H
L
CH11
H
H
L
L
L
CH12
H
H
L
H
L
CH13
H
H
H
L
L
CH14
H
H
H
H
L
CH15
1/ Between (CH0-CH15) and OUTPUT1 (0-15)
TRUTH TABLE (CH16–CH31)
B3
B2
B1
B0
EN (16-31)
"ON" CHANNEL, 2/ (OUTPUT 2)
X
X
X
X
H
NONE
L
L
L
L
L
CH16
L
L
L
H
L
CH17
L
L
H
L
L
CH18
L
L
H
H
L
CH19
L
H
L
L
L
CH20
L
H
L
H
L
CH21
L
H
H
L
L
CH22
L
H
H
H
L
CH23
H
L
L
L
L
CH24
H
L
L
H
L
CH25
H
L
H
L
L
CH26
H
L
H
H
L
CH27
H
H
L
L
L
CH28
H
H
L
H
L
CH29
H
H
H
L
L
CH30
H
H
H
H
L
CH31
2/ Between (CH16-CH31) and OUTPUT2 (16-31)
SCD8544 Rev C 5/14/15
5
Aeroflex Plainview
VIH
Address Lines
(A0 - A3)
50%
VIL
VIN(CH A0-3’)
Output
VOUT
50%
VIN(CH A0-3)
t AHL
VIH
Address Lines
(A0 - A3)
50%
VIL
VIN(CH A0-3’)
Output
VOUT
50%
VIN(CH A0-3)
t ALH
VIH
Enable Lines
EN
50%
VIL
VIN(HIGH)
Output
VOUT
SELECTED
CHANNEL
HI-Z
HI-Z
50%
VIN(LOW)
tONEN
tOFFEN
NOTE: f = 10KHz, Duty cycle = 50%.
RHD8544 SWITCHING DIAGRAMS
SCD8544 Rev C 5/14/15
6
Aeroflex Plainview
PIN NUMBERS & FUNCTIONS
RHD8544 – 56 Leads Ceramic QUAD Flat Pack
Pin #
Function
Pin #
Function
1
CH0
29
CH31
2
CH1
30
CH30
3
CH2
31
CH29
4
CH3
32
CH28
5
CH4
33
CH27
6
CH5
34
CH26
7
GND
35
GND
8
GND
36
GND
9
CH6
37
CH25
10
CH7
38
CH24
11
CASE GND
39
NC
12
OUTPUT1 (0-15)
40
B3
13
EN (0-15)
41
B2
14
A0
42
B1
15
A1
43
B0
16
A2
44
EN (16-31)
17
A3
45
OUTPUT2 (16-31)
18
+VCC
46
GND
19
CH15
47
CH16
20
CH14
48
CH17
21
GND
49
GND
22
GND
50
GND
23
CH13
51
CH18
24
CH12
52
CH19
25
CH11
53
CH20
26
CH10
54
CH21
27
CH9
55
CH22
28
CH8
56
CH23
Notes:
1. It is recommended that all "NC" or "no connect pin", be grounded. This eliminates or minimizes any ESD or static buildup.
2. Package lid is internally connected to circuit ground (Pins 7, 8, 11, 21, 22, 35, 36, 46, 49, 50).
SCD8544 Rev C 5/14/15
7
Aeroflex Plainview
ORDERING INFORMATION
Model
DLA SMD #
Screening
Package
RHD8544-7
-
Commercial Flow, +25°C testing only
RHD8544-S
-
Military Temperature, -55°C to +125°C
Screened in accordance with the individual Test Methods
of MIL-STD-883 for Space Applications
RHD8544-201-1S
5962-1220901KXC
In accordance with DLA SMD
RHD8544-901-1S
5962H1220901KXC
In accordance with DLA Certified RHA Program Plan to RHA
Level "H", 1Mrads(Si)
QUAD
Flat Pack
Note: Outside ceramic tie bars
not shown for clarity. Contact
factory for details.
0.650 ±.005
(13 Spaces at .050)
Tol Non-Cum
4 Sides
Pin 1
Pin 7
.200
MAX
Pin 50
Pin 49
Pin 8
.0165
±.003
0.800 SQ
±.010
Pin 21
(.650)
Pin 36
Pin 35
Pin 22
.006
±.002
FLAT PACKAGE OUTLINE
EXPORT CONTROL:
This product is controlled for export under the U.S. Department of Commerce (DoC). A license may be required prior to the export
of this product from the United States.
www.aeroflex.com/HiRel
[email protected]
Datasheet Definitions:
Advanced
Preliminary
Datasheet
Product in Development
Shipping Non-Flight Prototypes
Shipping QML and Reduced HiRel
Aeroflex Plainview, Inc. reserves the right to make changes to any products and
services described herein at any time without notice. Consult Aeroflex or an authorized
sales representative to verify that the information in this data sheet is current before
using this product. Aeroflex does not assume any responsibility or liability arising out
of the application or use of any product or service described herein, except as expressly
agreed to in writing by Aeroflex; nor does the purchase, lease, or use of a product or
service from Aeroflex convey a license under any patent rights, copyrights, trademark
rights, or any other of the intellectual rights of Aeroflex or of third parties.
SCD8544 Rev C
5/14/15
8
Our passion for performance is defined by three attributes.
Solution-Minded
Performance-Driven
Customer-Focused