Siemens Series Rating Chart Switchboards SB1, SB2, SB3 Panelboard S1 Max System Voltage Maximum SCCR 65kA 120/240 Vac 100kA (See Notes on Page 2) Line Side Max Fuse Load side Fuse Current Rating Circuit Breaker Amps LPJ, LPN-RK 600 15-70 QPH, BQH, BLH JJN (300V) 1200 15-125 KRP-C 6000 15-100 15-70 QP, BQ, BL 15-125 15-100 HQP, HBQ, HBL, QPH, 15-100 BQH, BLH QPF, BQF, BLF, QE, BE, 200 BLE, QEH, BLEH, BLHF, 15-30 JJN QPHF, BQHF (300V) QEH, BLEH, QE, QPHF, 15-60 BLHF, BLE, QPF, BLF QT 600 LPJ, LPN-RK JJN (300V) 600 1200 100kA 240 Vac 200kA © 2000 Cooper Bussmann, Inc. KRP-C 6000 LPN-RK JJN (300V) LPJ LPJ, LPN-RK JJN (300V) 200 400 600 600 1200 KRP-C 6000 QPH, BQH, BLH, HQP, HBQ, HBL ED4, HED4 ED4, ED6, HED4, HED6 FD6-A, FXD6-A JD6-A, JXD6-A, JXD2-A, SJD6-A LD6-A SLD6-A LXD6-A ED4, HED4 ED4, ED6, HED4, HED6 FD6-A, FXD6-A JD6-A, JXD6-A, JXD2-A, SJD6-A LD6-A Poles 1 (120V) 2 3 1 (120V) 2 3 3 1 (120V) 2 15-50 15-70 15-125 15-100 15-100 15-125 70-250 1 (120V),2 1 (120V) 2 3 1 (120V) 2,3 2,3 200-400 2,3 200-600 300-600 450-600 15-100 15-125 70-250 2,3 3 2,3 1 (120V) 2,3 2,3 200-400 2,3 200-600 2,3 SLD6-A 300-600 3 LXD6-A ED4, HED4 450-600 15-100 2,3 1 (120V) ED4, ED6, HED4, HED6 15-125 2,3 FD6-A, FXD6-A JD6-A, JXD6-A, JXD2-A, SJD6-A LD6-A SLD6-A LXD6-A SMD6 SND6 PD6, PXD6, SPD6 RD6, RXD6 QJH2, QJ2H, QJ2 QJ2 QJH2, QJ2H HFD6, HFXD6 HFD6, HFXD6 HFD6, HFXD6 MD6, MXD6, HMD6, HMXD6 ND6, NXD6, HND6, HNXD6 70-250 2,3 200-400 2,3 200-600 300-600 450-600 500-800 500-1200 1200-1600 1600-2000 125-200 125-225 125-225 70-250 70-250 70-250 2,3 3 2,3 3 3 3 3 2,3 2,3 2,3 2,3 2,3 2,3 500-800 2,3 500-1200 2,3 Page1 of 2 10/3/00 Siemens Series Rating Chart Switchboards SB1, SB2, SB3 Panelboards S2, SE, S3, S4, S5 Max System Voltage (See Notes Below) Maximum SCCR Line Side Fuse Max Fuse Current Rating 50kA LPJ 400 LPJ JJS, LPJ LPJ, LPS-RK 400 600 600 JJS, LPJ, LPS-RK 600 JJS 800 JJS, KRP-C 1200 KRP-C 6000 480 Vac 100kA 480/277V LPS-RK 100 JJS, LPJ 200 200kA Load side Circuit Breaker Amps 60-100 ED4 15-100 ED4 15-50 FD6-A, FXD6-A 70-250 HFD6, HFXD6 70-250 JD6-A, JXD6-A, HJD6-A, 200-400 HJXD6-A LD6-A, HLD6-A 200-600 LXD6-A, HLXD6-A 450-600 HFD6, HFXD6 70-250 JD6-A, JXD6-A, HJD6-A, 200-400 HJXD6-A LD6-A, HLD6-A 200-600 LXD6-A, HLXD6-A 450-600 HFD6, HFXD6 70-250 MD6, MXD6, HMD6, 500-800 HMXD6 ND6, NXD6, HND6, 500-1200 HNXD6 BQD, CQD 15-100 BQD*, CQD * 20-30 BQD, CQD 15-100 BQD*, CQD * 20-30 Poles 1 (277V) 2,3 1 (277V) 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 1 (277V) 2,3 1 (277V) 2,3 * BQD and CQD breakers are series rated from 15-100A for Series 7A, S2 and S3 panelboard applications only. NOTE (1): The data in these charts was compiled from information in Siemens SpeedFax 2000 Electrical Products publication, catalog reference number GNPC-01000. Cooper Bussmann assumes no responsibility for the accuracy or reliability of the information. The information contained in the tables may change without notice due to equipment design modifications. NOTE (2): The line-side fused switch may be in a separate enclosure or in the same enclosure as the loadside circuit breaker. A line-side fused switch may be integral or remote. NOTE (3): Max fuse current rating denotes the largest amperage fuse that may be used for that series rated combination. A lower amperage fuse may be substituted for the listed fuse. © 2000 Cooper Bussmann, Inc. Page2 of 2 10/3/00