Cutler-Hammer Series Rating Chart Switchboards: PRL-C / PRL-i (See Notes on Page 3) Panelboards: PRL 5P, PRL 4, PRL 3A & Pow-R-Command Panelboards Max System Voltage Maximum SCCR 100kA 120/240 200kA 100kA Line Side Fuse LPN-RK Max Fuse Current Rating 200 JJN, LPJ 400 LPN-RK 100 JJN, LPJ 200 JJN, LPJ 400 LPN-RK 200 JJN, LPJ 400 JJN KRP-C 600 6000 KRP-C 6000 LPN-RK 100 240 200kA 65kA 480/277 100kA 200kA 480 100kA 200kA LPN-RK 200 JJN, LPJ 200 JJN, LPJ 400 JJS, LPJ JJS, LPJ LPS-RK LPJ 200 100 200 600 JJS 600 LPS-RK JJS, LPJ LPS-RK JJS, LPJ KRP-C KRP-C 100 400 100 200 1200 800 100 LPS-RK 100kA 600 JJS, LPJ 200kA © 2000 Cooper Bussmann, Inc. KRP-C LPS-RK JJS, LPJ 200 400 600 200 400 1200 400 600 Page1 of 3 Load Side Circuit Breaker GB, GHB BA, BAB, HQP, QBHW, QPHW BA, BAB, HQP, QBHW, QPHW, GB, GHB BA, BAB, HQP, QBHW, QPHW GB, GHB GHB GB, CA BAB_H, QBHW_H, HQP_H, QPHW_H CA, CAH, HCA EHD, FD FDB, ED, JDB, JD, DK, KDB, KD GHB BAB_H, QBHW_H, HQP_H, QPHW_H, CAH, HCA, GB GB, GHB BAB_H, HQP_H, QBHW_H, QPHW_H, CA, CAH, HCA GHB GB GHBS GHBS GHB EHD, FD, HFD, FDC GHB, EHD, FD, HFD, FDC, JD, HJD, JDC Amps ALL Poles 1,2 ALL 1,2 ALL 1,2 ALL 1,2 ALL ALL ALL 1,2 1,2,3 2,3 ALL 2,3 ALL ALL 2,3 1,2,3 ALL 2,3 ALL 1,2,3 ALL 2,3 ALL 2,3 ALL 2,3 ALL ALL ALL ALL ALL ALL 1,2,3 2,3 1,2 1,2 1,2,3 2,3 ALL 2,3 GHB ALL 1,2,3 EHD EHD, FD, HFD,FDC MC, HMC, NC, HNC MC, HMC FD, HFD FDC JD, HJD, JDC KD, HKD, KDC LC FD, HFD FDC JD, HJD, JDC LC LC KD, HKD, KDC, LC ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 10/3/00 Cutler-Hammer Series Rating Chart Panelboards: PRL 1A, PRL 2A, PRL 1A-LX, PRL 2A-LX Max System Voltage Maximum SCCR 100kA 120/240 200kA 100kA Line Side Fuse LPN-RK Max Fuse Current Rating 200 JJN, LPJ 400 LPN-RK 100 JJN, LPJ 200 JJN, LPJ 400 LPN-RK 200 JJN, LPJ 400 JJN KRP-C 600 6000 KRP-C 6000 LPN-RK 100 LPN-RK 200 JJN, LPJ 200 JJN, LPJ 400 JJS, LPJ JJS, LPJ LPS-RK LPJ 200 100 200 600 JJS 600 LPS-RK JJS, LPJ 100 400 240 200kA 65kA 480/277 100kA 200kA (See Notes Below & Page 3) Load Side Circuit Breaker GB, GHB BA, BAB, HQP, QBHW, QPHW BA, BAB, HQP, QBHW, QPHW, GB, GHB BA, BAB, HQP, QBHW, QPHW GB, GHB GHB GB, CA BAB_H, QBHW_H, HQP_H, QPHW_H CA, CAH, HCA EHD, FD FDB, ED, JDB, JD, DK, KDB, KD GHB BAB_H, QBHW_H, HQP_H, QPHW_H, CAH, HCA, GB GB, GHB BAB_H, HQP_H, QBHW_H, QPHW_H, CA, CAH, HCA GHB GB GHBS GHBS GHB EHD, FD, HFD, FDC GHB, EHD, FD, HFD, FDC, JD, HJD, JDC GHB Amps ALL Poles 1,2 ALL 1,2 ALL 1,2 ALL 1,2 ALL ALL ALL 1,2 1,2,3 2,3 ALL 2,3 ALL ALL 2,3 1,2,3 ALL 2,3 ALL 1,2,3 ALL 2,3 ALL 2,3 ALL 2,3 ALL ALL ALL ALL ALL ALL 1,2,3 2,3 1,2 1,2 1,2,3 2,3 ALL 2,3 ALL 1,2,3 Notes for above Table: 1) The HQP & QPHW are not listed for use in the PRL1A-LX Panel. 2) PRL1A & PRL1A-LX are for use at 240V maximum. 3) Branch breakers for maximum 120/240V systems include: BAB, HQP, QBHW & QPHW. 4) Branch breakers for maximum 240V systems include: BAB_H, HQP_H, QBHW_H & QPHW_H. 5) PRL2A & PRL2A-LX, branch breakers include: GHB, GHBS & GB. 6) PRL1A-LX & PRL2A-LX Main & Sub-feed breakers include: ED, FD, HFD, FDC. 7) PRL1A & PRL2A Main & Sub-feed breakers include: CA, CAH, HCA, ED, FD, HFD, FDC, JD, HJD, JDC, KD, HKD & KDC. © 2000 Cooper Bussmann, Inc. Page2 of 3 10/3/00 Cutler-Hammer Series Rating Chart (See Comments Below) Triple Series Rating - Switchboards: PRL-C & PRL-i Panelboard Types: PRL 5P, PRL 4, PRL 3A, PRL 2A, PRL 2A-LX, PRL 1A, PRL 1A-LX & Pow-R-Command Panels Max System Voltage Maximum SCCR Line Side Fuse 120/240 100kA KRP-C (Max Fuse Size - 6000A) Tenant Main Type DK, KDB, KD JD, JDB FD FD, FDB EHD DK, KDB, KD 240 100kA KRP-C (Max Fuse Size - 6000A) JD, JDB FD FD, FDB EHD Branch Type Circuit Breaker GB, GHB GB, GHB GB, GHB HQP BA, BAB BA, BAB, HQP GHB GB, EHD CA, CAH, HCA FD, FDB JD, JDB GHB GB GHB GB BAB_H, QBHW_H, HQP_H, QPHW_H BAB_H, HQP_H Amps ALL ALL ALL 15-70 ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL Poles 1,2 1,2 1,2 1,2 1,2 1,2 1,2,3 2,3 2,3 2,3 2,3 1,2,3 2,3 1,2,3 2,3 ALL 2,3 ALL 2,3 NOTE (1): The data in these charts was compiled from information in Cutler-Hammer, Series Rating Information Manual, catalog reference number 1C96944H01 Rev. E, pages 18-24, and Cutler-Hammer Consulting Application Catalog 12th Edition, pages F1-11 - F1-12. Cooper Bussmann assumes no responsibility for the accuracy or reliability of the information. The information contained in the tables may change without notice due to equipment design modifications. NOTE (2): The line-side fused switch may be in a separate enclosure or in the same enclosure as the load-side circuit breaker. A line-side fused switch may be integral or remote. NOTE (3): Max fuse current rating denotes the largest amperage fuse that may be used for that series rated combination. A lower amperage fuse may be substituted for the listed fuse. © 2000 Cooper Bussmann, Inc. Page3 of 3 10/3/00