Meeting Elevator Disconnect Requirements Has Never Been Easier The Cooper Bussmann® Quik-Spec™ Power Module™ Switches and Panels Offer the Superior All-In-One Solution • Easy-to-Specify No need to worry if you’re meeting Code requirements. The Cooper Bussmann® Quik-Spec™ Power Module™ Switch build-a-code assures you get all the right components, with the right ratings, properly assembled. See Data Sheet 1145* for more details. • Easy-to-Install The Quik-Spec Power Module Switch comes as a completely assembled unit for quick installation. This all-in-one solution reduces the labor and time needed to assemble individual components. • Provides Easy Selective Coordination To meet this Code and end-user requirement, the Quik-Spec Power Module Switch utilizes Cooper Bussmann® Low-Peak® Class J fuses that easily coordinate with any upstream Low-Peak fuse by simply using a 2:1 lineside-toloadside fuse ratio. • UL 98 Listed The Quik-Spec Power Module Switch meets prevailing ANSI/ASME, NEC® and NFPA 72 requirements in a UL 98 Listed (enclosed switch) and UL 50 Listed (enclosure) unit. • Quik-Spec™ Power Module™ Panel for Multi-Elevator Applications Featuring multiple switches in a single panel, the Quik-Spec Power Module Panel offers significant space savings. Like the switch, the Quik-Spec Power Module Panel is easy to specify and factory configured to meet prevailing ANSI/ASME, NEC® and NFPA 72 requirements for UL 98 Enclosed and Dead-Front Switches. To order, just call your Cooper Bussmann representative with all relevant electrical and circuit information, and we do the rest. See Data Sheet 1146* for more details. * Data Sheets online at www.cooperbussmann.com/datasheets/ulcsa. Now A vailab le With Quik-S hip Servic e • Switches ship within 3 business days • Panels ship within 10 business days • See back page for details Specify and Install the Quik-Spec™ Power Module™ with Confidence The Quik-Spec Power Module Switch and Panel are the best choices for design engineers and electrical contractors that need to meet these requirements, Codes and standards: • Elevator Shutdown – ANSI/ASME A17.1, 2.8.3.3.2 – NEC® 620.51(B) (Elevator Shutdown) – NEC® 240.12 (Orderly Shutdown) • Shunt Trip Voltage Monitoring – NFPA 72, 6.16.4.4 • Selective Coordination – NEC® 620.62 • Auxiliary Contact (Hydraulic Elevator) – NEC® 620.91(C) The Quik-Spec Power Module Switch (PS) for single elevator applications Both Quik-Spec Power Module Switches and Panels provide: • • • • • • • • • • Shunt trip capability Selective coordination Fire safety signal interface Shunt trip voltage monitoring Component protection via Cooper Bussmann® Low-Peak® Class J fuses UL 98 Listed for 200kA short-circuit current rating Lockable in the open position with three lock capability Optional key-test switch and optional pilot light for easy inspection No annual calibration or testing of overcurrent protection required Padlockable for service work safety and open door “override” for troubleshooting Quik-Spec Power Module Panel (PMP) for multiple elevator applications Note: Always follow established safety practices when working on a electrically live equipment. Quik-Spec Power Module Switch Catalog Numbering System Use the following build-a-code to specify the exact Quik-Spec Power Module Switch you need for your application. PS 1 T48 R1 Control Transformer* T20 = 208V T24 = 240V T48 = 480V T60 = 600V Prefix PS = Power Module Switch Amp Rating 3 = 30A 6 = 60A 1 = 100A 2 = 200A 4 = 400A K G B Neutral Lug (Optional) N6 = 30-60A N1 = 100A N2 = 200A N4 = 400A Key Test Switch (Optional) K = Key Fire Safety Interface Relay (3PDT, 10A, 12V) R1 = 120Vac Coil R2 = 24Vdc Coil N1 Pilot Light ON (Optional) G = Green R = Red W = White F1 Fire Alarm Voltage Monitoring Relay (Optional) To Monitor Shunt Trip Voltage F1 = Single-Pole F3 = Three-Pole** Auxiliary Contacts B = 2 NO/NC * 100VA with Primary and Secondary fusing (120V Secondary) ** For use only with R1 option Quik-Ship Program: Switch - 3 Days, Panel - 10 Days! Ship-direct service within three business days for Power Module Switches (PS_) and 10 business days for Power Module Panels (PMP_). * Three day PS_ shipment requires ordering from catalog numbers shown. ** 10 Day PMP_ shipment covers NEMA 1 enclosures with the ampacities shown and all requirements for relay type (AC or DC), accessory options and number of switches. To order PMP_, contact your Cooper Bussmann representative with all relevant electrical and circuit information, we do the rest. Power Module Switch* Cat Numbers Amps PS6T48R1KGBF3-X 60A PS1T48R1KGBF3-X 100A PS1T20R1KGBF3-X 100A PS2T48R1KGBF3-X 200A PS2T20R1KGBF3-X 200A © 2009 Cooper Bussmann St. Louis, MO 63178 636-394-2877 w w w. c o o p e r b u s s m a n n . c o m Reorder # 3136 0809-5M Printed in USA U Volts 480V 480V 208V 480V 208V Enclosure Options (TYPE 1 Standard No Suffix Designation Required) U = Type 3R Z = Type 12 Y = Type 4 Power Module Panel** Cat. Numbers Amps PMP-400-X 400A PMP-600-X 600A PMP-800-X 800A