CONNOR-WINFIELD STL-S3

Stratum 3 Timing Module
STL-S3
2111 Comprehensive Drive
Aurora, Illinois 60505
Phone: 630- 851- 4722
Fax: 630- 851- 5040
www.conwin.com
Features
Application
The Connor-Winfield Stratum 3 Simplified
Control Timing Module acts as a complete
system clock module for Stratum 3 timing
applications in accordance with GR-1244CORE, Issue 2, GR-253-CORE, Issue 3,
and ITU-T G.812, Option ΙΙΙ.
Connor-Winfield’s Stratum 3 Timing
module helps reduce the cost of your
design by minimizing your development
time and maximizing your control of the
system clock with our simplified design.
Bulletin
Page
Revision
Date
Issued By
TM055
1 of 24
P00
17 MAY 04
MBATTS
• 6 Input
References
• Hitless Switch
Over
• CMOS output up
to 77.76 MHz
• 8 kHz Output
• Fast Acquisition
Mode
• Manual/
Autonomous
Operation
• Master/Slave
Configuration
• Revertive/Nonrevertive Modes
General
Pin Diagram
Connor-Winfield's STL timing module provides Stratum
3 synchronization for a complete system clock solution in a
single module in accordance with GR-1244-CORE Issue 2, GR253-CORE Issue 3, and ITU-T G.812 Option III. The STL
provides a reliable network element clock reference to line cards
used in TDM, PDH, SONET, and SDH application environments.
Typical applications include digital cross connects, DSLAMs,
ADMs, multiservice platforms, switches and routers.
The STL meets 0.37 ppm Hold Over requirements over
0° - 70°C temperature range. The 3.3V power requirement will
draw a maximum of 1.3 A during an initial start-up period and
then drop to a typical current of 0.5A during normal operating
conditions. It accepts six input references and can supply up to
3 CMOS outputs (see Tables 1-4 for specific information).
Figure 1
Top View
Pin 1
Pin 17
Hold Over
Ref. 3 Indicator
Ref. 1 Indicator
Ref. 4 Indicator
Ref. 2 Indicator
Ref. 5 Indicator
Free Run Indicator
Ref. 6 Indicator
GND
Reset
Alarm
Output 3
CNTRL 1
CNTRL 3
CNTRL 2
SPI Enable
Lock
Pin 34
VCC
Ext. Ref. 5
Ext. Ref. 1
Ext. Ref. 3
GND
Ext. Ref. 6
Ext. Ref. 2
Ext. Ref. 4
GND
Slave Input
Output 2
SPI_IN
GND
SPI_CLK
Output 1
SPI_OUT
GND
Pin 18
Functional Block Diagram
Figure 2
Reference 1
SPI Port
SPI_CLK
SPI_IN
SPI_OUT
÷Nc
External Ref #4
÷Nd
External Ref #5
÷Ne
External Ref #6
Slave Input
X
÷Nf
X
Alarm
Lock
Hold Over
Free Run
Frequency
Control
External Ref #3
LOR
Detect
Refence
Primary Qualification
Loop
Loop
÷Nb
DSP
Status
Indicators
CNTRL 2
CNTRL 3
External Ref #2
Reference 4
Reference 6
Control
÷Na
Reference 3
Reference 5
CNTRL 1
External Ref #1
Reference 2
Reference
Indicators
Reset
SPI_ENBL
Output 1
DDS
÷R
Output 2
÷R
Output 3
÷W
÷Ng
OCXO
÷M
Absolute Maximum Rating
Table 1
Symbol
Parameter
Minimum
Maximum
Units
Notes
VCC
Power Supply Voltage
-0.5
Nominal
4.0
Volts
1.0
VI
Input Voltage
-0.5
5.5
Volts
1.0
Ts
Storage Temperature
-40
85
deg. C
1.0
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 2 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Recommended Operating Conditions
Table 2
Symbol
Parameter
Minimum
Nominal
Maximum
Units
Vcc
Power Supply Voltage
3.135
3.465
Volts
VIH
High level input voltage - CMOS
2.0
5.25
Volts
VIL
Low level input voltage - CMOS
0
0.8
tPULSE
Minimum pulse width, positve/negative
for external references
30
tTR
Input signal transistion time
tRST
Time for module to re-configure after a reset
(manual or POR)
tHLD
Time to hold reset pin high
Notes
2.0
Volts
ns
250
1.5
ns
sec.
0.3
100
ms
DC Characteristics
Table 3
Symbol
Parameter
Minimum
Nominal
Maximum
Units
Notes
VOH
High level output voltage,
IOH = -4.0mA, VCC = min.
2.4
3.3
3.6
Volts
3.0
VOL
Low level output voltage,
IOL = 8.0mA, V CC = max.
0.4
Volts
Specifications
Table 4
Parameter
Specifications
Frequency Range - Output 1
Output 2
Output 3
Supply Current
Notes
8 kHz - 77.76 MHz
6.0
8 kHz - 77.76 MHz
6.0
8 kHz - 77.76 MHz
6.0
0.5A typical @25°C, 1.3 A during warm-up (Maximum)
Timing Reference Inputs
8 kHz - 77.76 MHz
Slave Input
8 kHz
6.0
Jitter, Wander and Phase Transient Tolerances
GR-1244-CORE 4.2-4.4, GR-253-CORE 5.4.4.3.6
Wander Generation
GR-1244-CORE 5.3, GR-253-CORE 5.4.4.3.2
Wander Transfer
GR-1244-CORE 5.4
Jitter Generation
GR-1244-CORE 5.5, GR-253-CORE 5.6.2.3
Jitter Transfer
GR-1244-CORE 5.5, GR-253-CORE 5.6.2.1
Phase Transients
GR-1244-CORE 5.6, GR-253-CORE 5.4.4.3.3
Output 1,2 & 3 Free Run Accuracy
±4.6 ppm over temperature range
Hold Over Stability
±0.370 ppm
Inital Offset
±0.050 ppm
Temperature
±0.280 ppm
Drift
4.0
±0.040 ppm
Maximum Hold Over History
1049 seconds
Minimum Time for Hold Over
141 seconds after a reference rearrangement
Lock Time
100 sec.
Lock Accuracy
0.1 ppm
5.0
Environmental Characteristics
Shock
100G’s, 6mS, halfsine per MIL-STD-202F, Method 2138, Test Condition C
Vibration
0.06" D.A. or 10G peak 10 to 500 Hz, per MIL-STD-202F, Method 204D, Test Condition A
NOTES:
1.0: Stresses beyond those listed under Absolute Maximum Rating may cause damage
to the device. Operation beyond Recommended Conditons is not implied.
2.0:
Inputs are 3.3V CMOS,5V tolerant
3.0:
Logic is 3.3V CMOS
4.0:
5.0:
6.0:
Hold Over stability is the cumulative fractional frequency offset as described by
GR-1244-CORE, 5.2
After 100 seconds at stable temperature (±5° F)
Frequencies must be specified at the time of order.
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 3 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Pin Description
Table 5
Pin #
1
Connection
Description
Hold Over
Indicator = 1 when module is in Hold Over
2
Reference 3
Indicator = 1 when module is locking to or is locked to external reference 3
3
Reference 1
Indicator = 1 when module is locking to or is locked to external reference 1
4
Reference 4
Indicator = 1 when module is locking to or is locked to external reference 4
5
Reference 2
Indicator = 1 when module is locking to or is locked to external reference 2
6
Reference 5
Indicator = 1 when module is locking to or is locked to external reference 5
7
Free Run
Indicator = 1 when module is in Free Run
8
Reference 6
Indicator = 1 when module is locking to or is locked to external reference 6
9
GND
Ground
10
Reset
Reset Pin (↓)*
11
Alarm
Indicator = 1 when module is in an alarm condition
12
Output 3
8 kHz output derived from system clock
13
CNTRL 1
Mode control input for manual operation. (↓)
14
CNTRL 3
Mode control input for manual operation. (↓)
15
CNTRL 2
Mode control input for manual operation. (↓)
16
SPI Enable
Enable for SPI communication por t. (↑)
17
Lock
Indicator = 0 when module is locked to selected reference.
18
GND
Ground
19
SPI_OUT
Serial data output for SPI communication
20
Output 1
System clock output
21
SPI_SCLK
Input clock for SPI communication. (↓)
22
GND
Ground
23
SPI_IN
Serial data input for SPI communication
24
Output 2
8 kHz output derived from system clock
25
Slave Input
Input for synchronizing a module in slave configuration.
26
GND
Ground
27
External Reference 4
External reference input #4
28
External Reference 2
External reference input #2
29
External Reference 6
External reference input #6
30
GND
Ground
31
External Reference 3
External reference input #3
32
External Reference 1
External reference input #1
33
External Reference 5
External reference input #5
34
VCC
+3.3Vcc power supply required
(↑) = Internal pull-up
(↓) = Internal pull-down
Internal pull-up/pull-down resistors range from 50 kΩ to 100 kΩ
(↓)* = 10 kΩ pull-down resistor
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 4 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Functional Truth Table
Table 6
Reference#
Alarm
Lock
Hold Over
Free Run
Condition
1
0
1
0
0
Locking to selected reference but the phase error is > 20µs
1
0
0
0
0
Tracking selected reference and the phase error is ≤ 20µs
0
1
1
1
0
Auto Mode - There are no valid references so module has
entered Hold Over.
0
1
1
1
0
Manual Mode - Module is in Hold Over mode.
0
1
1
0
1
Auto Mode - There are no valid references and there is no
valid Hold Over history so module has entered
Free Run.
0
1
1
0
1
Manual Mode - Module is in Free Run mode.
0
0
0
0
0
Slave Mode - Module is locked to master module and phase
error is ≤ 20µs
0
0
1
0
0
Slave Mode - Module is locked to master module and phase
error is > 20µs
0
1
1
0
0
Slave Mode - Module is unable to track master module due to
Loss of Reference condition or the frequency
is out of range.
Control Inputs
Table 7
CNTRL3/CF3
CNTRL2/CF2
CNTRL1/CF1
Mode of Operation
0
0
0
Free Run
0
0
1
Locked to Ref #1
0
1
0
Locked to Ref #2
0
1
1
Hold Over
1
0
0
Locked to Ref #3
1
0
1
Locked to Ref #4
1
1
0
Locked to Ref #5
1
1
1
Locked to Ref #6
Module Restabilization Times
Table 8 - For a given off-time, the time required to meet daily aging, short term stability and TDEV requirements:
Off Time
Restabilization Time
< 1 Hour
< 1.5 Hours
< 6 Hour
< 8 Hours
< 24 Hour
< 36 Hours
1 to 16 Days
36 Hours + ¼ Off Time
> 16 Days
< 5 Days
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 5 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Operation Overview
The STL offers both manual and autonomous modes of operation, and the option of revertive or non-revertive reference switching
during autonomous mode. In manual mode, the user has control of the module using pins CNTRL 3:1 to determine whether the
module should lock to a specific reference, enter Free Run or enter Hold Over. In autonomous mode, the module determines the
proper operating behavior depending on the state of the external references, which are frequency qualified by the module. For
further details of autonomous operation, see the state diagram in Figure 3. The STL also offers master and slave modes and
incorporates reference qualification on all 6 external references and the Slave Input.
When the module is locked to a valid reference, the appropriate external indicator will be asserted for that reference. When
internal phase error is less than 20µs, the Lock signal will be asserted. The STL takes up to 100 seconds to obtain complete phase
lock to a qualified reference. To assure that the STL will always lock to any valid frequency offset within 100 seconds, the module
goes into a Fast Acquisition mode immediately after switching to a new reference. If the module experiences a Lock alarm after it
has phase-locked to the selected reference, the module will re-enter the Fast Acquisition stage of filtering if the reference has not
been disqualified. Once locked, the filtering will return to the 0.1 Hz filter. The filtering during Fast Acquisition mode will not allow
frequency movement faster than 2.9 ppm per second on a frequency step of up to 9.2ppm. Fast Acquisition mode is further
described as fast start mode in GR-1244-CORE, Issue 3, section 3.6. The current PLL status can be accessed via SPI port in
register 0Eh.
A manual reset pin called Reset is provided on pin 10 of the STL device. This will reset the DSP, FPGA, and DDS causing a
disruption in all programmable devices and is the same type of reset, though not software controlled, described in Table 16. The STL
device will treat this reset as if it were following a power-up; all registers are reset to their default values. Resetting the unit by cycling
the power requires more time for restablization of the internal ovenized oscillator and is not recommended.
Hold Over mode provides a stable frequency that is guaranteed to be within ±0.370ppm over the entire temperature range for the
first 24 hours after entry into Hold Over. The module establishes a new Hold Over history within 141 seconds after a reference is
selected and continues to do a running average every 8 seconds for the next 1049 seconds. Long-term Hold Over values are based
on a 1049 second moving window average. Hold Over values are not updated when the reference is disqualified or during Fast
Acquisition mode. Hold Over values are buffered for at least 32 seconds to allow enough time to respond to the alarms and
frequency qualification status.
Free Run is a mode of operation in which the module is not locked to a reference and its output frequency is solely dependent on
the initial frequency setting of the internal oscillator. The output frequency in Free Run is guaranteed to be ±4.6ppm of the nominal
frequency.
Reference qualification continually monitors all 6 input references, as well as the Slave Input. The references are monitored for
both frequency accuracy and presence. Although loss of presence is detected almost immediately due to being continually
monitored, a delay of approximately 7 seconds may occur before an out-of-band frequency is detected. This delay is caused by the
fact that reference qualification is done one reference at a time, in a round robin fashion. Each reference takes just over one second
to qualify, and so cycle time is the cause of the delay.
The STL module provides three output frequencies. Output 1 is the primary synchronized output. It is phase locked to the input
reference during normal operation and is set to a fixed frequency when operating in Hold Over or Free Run. Output 2 and Output 3
are derived from Output 1.
The STL module provides a variety of alarm and status information to alert the user to multiple conditions that may affect the
overall performance of their system. Some of this information is brought out to external pins, while other information is accessible
through the SPI port on internal memory-mapped registers. Status information from reference qualification, including frequency
offsets, is contained in these registers; information regarding phase build out and valid Hold Over is also stored here. Additionally,
the current mode of operation and SPI status are available. Certain features of the STL are programmable by the user. For complete
details on memory-mapped registers, please see SPI Timing and Operation section. For SPI timing, see Figures 7-8.
In master mode, the module will experience an alarm condition (Alarm=1) when the module is in Hold Over or Free Run. In
manual mode, an alarm condition will occur if the user selects Hold Over, Free Run or a reference that is disqualified. If the
reference is disqualified after the module starts to track it, the module will enter holdover if a valid holdover history is available, or the
unit will enter Free Run (see figure 19). In autonomous mode, the module will experience an alarm condition when there are no
available references. This may be caused by all references being disqualified by LOR or an off-frequency condition or all references
may be set to unavailable in the priority table. In these cases, the module will enter holdover if there is a valid holdover history
available, or the module will enter Free Run. In slave mode, the module will experience an alarm condition if the module is not able
to lock to the master because the master frequency has exceeded the pull-in range of the slave, or due to an LOR of the master.
The Lock indicator will be de-asserted (Lock=1) when the internal phase error is greater than 20us from the final, locked value
(See figure 20). This alarm can occur when the unit is initially locking to a new reference, or it can occur after lock if the module
loses lock. This alarm will be de-asserted (Lock=1) during holdover and freerun modes.
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 6 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Phase build out operation can be inter nally enabled or disabled through the internal memory-mapped registers. It is initially
disabled. Internal circuitry monitors the input reference for greater than 3.4µs of change over any 0.1 second interval. When this
occurs, internal buffers are reset so that the phase change is ignored, allowing the phase shift between input and output. Any phase
shift smaller than 3.4µs over 0.1 seconds will be followed to re-establish the original input/output phase relationship, unless the rate
of change causes the reference to be disqualified. Refer to Reference Qualification section (pg. 10) for more details on
disqualification.
The STL meets the requirements for wander generation and wander transfer as required by GR-1244, sections 5.3 and 5.4. It
also complies with phase transient requirements during Reference Rearrangement, Entry into Hold Over, and 1µs transient. Input
jitter is attenuated at about 20 dB/decade to minimize the jitter noise passed on to other network elements or clocks. Figure 15
illustrates the STL's typical roll off of attenuated jitter.
Autonomous Mode
During autonomous mode, the unit makes the decision about which reference to track based on priority and qualification status.
The goal of the module is to lock onto the highest priority qualified reference. If the revertive option is selected, the module will
switch out of the current reference, even when that reference is still qualified, as soon as a higher priority qualified reference
becomes available. The module will also switch into the highest priority qualified reference when the current reference is disqualified.
If the non-revertive option is selected, the module will only switch into another reference when the current reference is disqualified.
If the current reference is disqualified, and there are no other qualified references to switch to, the module will enter the last valid
Hold Over value. As soon as a reference is qualified, the module will begin to track it. If no Hold Over value has been calculated,
then the unit will revert into Free Run until a reference is available. If multiple references are set to the same priority in the priority
table, the module will select the lowest reference number as the highest priority. For example, if Reference 5 and Reference 3 are
both set to priority 1, the module will consider Reference 3 to be of a higher priority than Reference 5 (assuming both are qualified
references).
Autonomous Mode State Diagram
Figure 3
*
ab
le
is a
va
il
s
ce i
ren
efe
dr
ble
availa
Valid
refe
ren
ce
li
Va
d reference is a
Vali d Fast Acquisit vailab
io
le
an
to phase-locn was
able
k
eference has bec
ive r
o
an
Act isqualified d anothe me
d eference is valid r
r
Fast Acquisition
Lock
Al
dis l re
f
Ho qua eren
av ld lifie ce
a i Ov d s a
la
ble er v and re
alu no
e
is
e
ar
es
c
d
n
re lifie
efe a
l r isqu
l
A d
Free Run
Hold Over
U ser re
t
sets Hold Over his
or y
*Note: During autonomous, revertive operation,
if a valid reference of a higher priority is
available, the module will switch from a
reference that is still qualified.
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 7 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Manual Mode
During manual operation, the mode of operation is determined by the user through either the external control pins CNTRL3:1 or
internal configuration bits CF3:1 (see Table 7). The default configuration is to have external control, but this can be changed to
internal control by setting the INT bit in the memory-mapped registers via the SPI port. During manual operation, the user can select
Free Run, Hold Over, or locked operation. Any of the six input references can be selected for the unit to track.
If the module is locked to a reference and that reference becomes disqualified, the module will automatically go into Hold Over. If
the module has been phase-locked to the current reference for at least 50 seconds and is in the final stage of the filter (as indicated
in register 0Eh), the Hold Over value will be derived from the data from the current reference. If the module has been phase-locked
to the current reference for less than 50 seconds, then the last valid Hold Over value will be used. If the control bits/pins remain in
the same selection that caused the unit to go into Hold Over, the unit will remain in Hold Over until the reference is re-qualified. At
that time, after a minimum 10s soak time, the unit will attempt to relock to the same reference.
If the external user control pins select a new reference that the module has not qualified, the module will switch into the last valid
Hold Over value. If the module has not yet established a valid Hold Over, the module will return to the pre-programmed Free Run
value. As soon as the module qualifies the selected reference, it will begin the locking process.
At no time during manual mode will the unit attempt to lock to a reference that is not selected by the external pins/internal bits.
The only mode that the unit will enter automatically is into Hold Over or Free Run, and that is due to a disqualification of the selected
reference.
Manual Mode State Diagram
Figure 4
di
is
act
ive
ref
ere
nc
e
aq
ua
lif
ects
User s
el
selects Hold Over
User
or
Lock
Run
Free
reference
fied
uali
aq
s
ect
sel
er
Us
ts
lec
se
er
Us
ied
re
fe
re
nc
e
ed
lifi
ua
q
s
cted ref. chang
Sele and
ed
cted ref. is va
Sele
lid
ref. has been acqu
ted
and
ired
lec
is selected
Se
Lock
Fast Acquisition
Us
o er
dis r ac sel
n o qu t i v e c
va ali e re ts F
l i d fi e
fe re
Ho d a ren e R
c
u
ld nd
Ov th e is n
er ere
his is
to
ry
er
Ov s
d
l
i
Ho nce
ts
e
r
c
e
e
f
l
se e re lified
er
a
iv
U s ac t i s q u
d
or
Free Run
Hold Over
Us
er
sel
e cts
Free R
un or resets H
U ser s
ve
old O
rh
ist
or
y
elects Hold Over
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 8 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Master/Slave Operation
During master operation, the master pays no attention to the Slave Input reference other than monitoring it for qualification
purposes. If the slave unit is removed, there is no behavioral change in the master.
During slave operation, the slave module locks to the Slave Input reference from the master, and continually qualifies it. If the
slave module determines that the master input has gone out of range, the slave continues to lock to the master until it reaches the
end of its pull-in/hold-in range, which is approximately ±125 ppm. If the slave determines that the Slave Input frequency from the
master has been removed, the slave will use its internal priority table (which should be configured the same as the master module)
and configuration registers to begin locking to the highest priority qualified reference (or to the selected input reference if the master
unit was in manual mode). As soon as the Slave Input from the master returns, (after a 10 sec. minimum soak time) the slave will
begin locking to it.
When the module is in slave mode, the external indicator pins (Reference 1-Reference 6, Free Run, Hold Over) will remain
low, regardless of the mode. If the module is locked to or is attempting to lock to the master, the alarm indicator will be low. The
LOCK alarm works normally as long as the module is tracking the master. If the master is lost (due to LOR or out of tracking range),
and the module enters another mode, the alarm and LOCK indicators will both remain high (=1). The internal PLL status register
(0Eh) must be read to determine the current mode of operation of the module.
The goal of the slave is to maintain a zero-phase error with the Slave Input from the master. In order to accomplish this, the BW
during slave mode is increased so that the slave can respond very quickly to any change in the master's frequency to minimize the
phase difference between master and slave.
Master/Slave State Diagram
Figure 5
Master Mode
Slave mode is selected
Master mode is selected
Slave Mode
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 9 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Reference Qualification
Reference qualification requires that a reference be both present and within the required frequency limits for a minimum of 10
seconds. Any time a reference is disqualified due to a loss of signal or frequency offset, the 10 second window will start over. The
active reference can also be disqualified if there is a phase-time movement on the input that is greater than the allowable movement
for jitter tolerance and frequency hold-in range. If active reference is disqualified due to a faster than allowed phase-time change
(phase hit), the module will immediately go into Hold Over (or Free Run if Hold Over is not valid) for a minimum of 2ms, after which
the module will act as though the reference was disqualified due to a LOR or off-frequency condition.
Reference Frequency Qualification Test
Figure 6
Reference
is not
qualified
Reference
may or may
not be
qualified
Reference
may or may
not be
qualified
Reference is qualified
(3ppm minimum)
Frequency
Rejection
Limit
Frequency
Qualification
Limit
Nominal
(3ppm minimum)
Frequency
Qualification
Limit
Reference
is not
qualified
Frequency
Rejection
Limit
SPI Timing and Operation
The SPI port is set up for 8 bit communication. All address bytes are 8 bits in length, reads return 8 bits and writes require 8 bits.
The MSB of each address byte is the read/write bit. The lower 7 bits are the lowest 7 bits of the specified address. For example, a
read from address 01h would require the byte 1000 0001b to be sent to the module, MSB first.
Table 9
A7
A6
A5
A4
A3
A2
A1
A0
R/W
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit0
Format for Address Byte
R/W: Read=1/Write=0
Bit 6 - Bit 0: Address Information
Send A7 First
Table 10
D7
D6
D5
D4
D3
D2
D1
D0
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Format for Data Byte
Bit 7 - Bit 0: Data Information
Receive/Send D7 First
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 10 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
SPI Timing Diagrams
Figure 7
Write Cycle
tclk
tpw
tpause-w
SPI_SCLK
ts
SPI_IN
th
A7 A6 A5 A4 A3 A2 A1 A0
D7 D6 D5 D4 D3 D2 D1 D0
SPI_OUT
SPI Enable
tec
tce
Figure 8
Read Cycle
tclk
tpw
tpause-r
SPI_SCLK
SPI_IN
A7 A6 A5 A4 A3 A2 A1 A0
SPI_OUT
D7 D6 D5 D4 D3 D2 D1 D0
SPI Enable
*See tables 9 & 10 for specific Bit information.
Parameter
Description
Min
tCLK
SPI CLK rising edge to SPI CLK rising edge
100 ns
tS
Setup time, Valid data to SPI CLK rising edge
10 ns
th
Hold time, Valid data following SPI CLK rising edge
1 ns
tpause-w
Minimum time between address and data byte, Write only
1s
tpause-r
Minimum time between address and data byte, Read only
1 ms
tec
Setup time, SPI Enable to first SPI CLK rising edge
(tCLK /2)
tce
Hold time, SPI Enable following last SPI CLK rising edge
(tCLK /2)
tpw
Pulse width, SPI CLK
(tCLK /2) - 10 ns
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 11 of 24
Max
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
SPI Memory Mapped Registers
The internal memory-mapped registers are accessible through the SPI port on the STL module. Some registers are read-only,
while others are are accessible for a read or a write operation. The registers contain status information, alarm information,
configuration tables, and ID registers. To access the registers, please see the read and write timing diagrams in Figures 7-8.
Table 11 - Register Map
Addrs
Description
00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
10h
11h
12h
13h
14h
15h
16h
17h
18h
19h
1Ah
1Bh
1Ch
Priority Selection Table
Reserved
Reference Measurement
Slave Reference Measurement
Reserved
Qualification Status for References and Slave Input
Phase-Locked Loop Status
Reserved
Reference Qualification Limits
Configuration
Reserved
Bandwidth Selection
SPI Status
Identification
Reserved
Table 12 - Priority Selection Table
Read/Write
Addrs
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Description
00h
P23
P22
P21
P20
P13
P12
P11
P10
Priority register for References 1 and 2
01h
P43
P42
P41
P40
P33
P32
P31
P30
Priority register for References 3 and 4
02h
P63
P62
P61
P60
P53
P52
P13,P12,P11,P10 - Priority for Reference 1(Default - 0110)
P23,P22,P21,P20 - Priority for Reference 2(Default - 0101)
P33,P32,P31,P30 - Priority for Reference 3(Default - 0100)
P43,P42,P41,P40 - Priority for Reference 4(Default - 0011)
P53,P52,P51,P50 - Priority for Reference 5(Default - 0010)
P63,P62,P61,P60 - Priority for Reference 6(Default - 0001)
P51
P50
Priority register for References 5 and 6
The Priority Selection Table registers contain default information on the priority of the references, but these registers can be
overwritten by the user. The lowest priority is 0000 and the highest priority is 0110. If a reference is given priority 0000, then that
reference will be evaluated for frequency and presence, but will be considered an unavailable reference in autonomous mode.
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 12 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
If multiple references are assigned the same priority, and the module is in autonomous, revertive mode, the module will select the
lowest reference number as the highest priority.
All priorities with a binary number greater than 0110 will be treated as though their priority was 0110. No 4-bit binary
combinations will be considered invalid.
Table 13 - Reference Measurement and Qualification Status
Read only
Addrs
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Description
04h
F17
F16
F15
F14
F13
F12
F11
F10
Reference 1 Frequency offset from Free Run
05h
F27
F26
F25
F24
F23
F22
F21
F20
Reference 2 Frequency offset from Free Run
06h
F37
F36
F35
F34
F33
F32
F31
F30
Reference 3 Frequency offset from Free Run
07h
F47
F46
F45
F44
F43
F42
F41
F40
Reference 4 Frequency offset from Free Run
08h
F57
F56
F55
F54
F53
F52
F51
F50
Reference 5 Frequency offset from Free Run
09h
F67
F66
F65
F64
F63
F62
F61
F60
Reference 6 Frequency offset from Free Run
0Ah
FS7
FS6
FS5
FS4
FS3
FS2
FS1
FS0
Slave Input frequency offset from Free Run
0Ch
R41
R40
R31
R30
R21
R20
R11
R10
Status indicators for References 1-4
0Dh
X
X
RS1
RS0
R61
R60
R51
R50
Status indicators for References 5-6
Fx7,Fx6,Fx5,Fx4,Fx3,Fx2,Fx1,Fx0 - Frequency offset of Reference x (Default - 1111 1111)
R#1,R#0 - Describes status of Reference #, see Table 20 (Default - 00)
X - Reserved for future use (Default - 0)
The Reference Measurement and Qualification Status registers hold the information regarding the specified reference’s frequency
offset from nominal (accurate to within 1.5 ppm of actual frequency) and status information regarding presence and qualification
status. The Frequency Offset registers have a resolution of 0.5 ppm, and are in 2s complement form. A maximum frequency offset of
+63.5 ppm or -64 ppm can be shown in these registers. If a reference is determined to have a frequency offset past these limits, the
register will only show the maximum. The Status Indicator registers show qualification status of each reference.
Table 14 - Phase-Locked Loop Status
Read only
Addrs
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
0Eh
HA
R2
R1
R0
S3
S2
S1
HA = 1 when Holdover history is available (Default - 0)
R2,R1,R0 - Describes reference in use, see Table 21 (Default - 000)
S3,S2,S1,S0 - Describes state of PLL, see Table 22 (Default - 1001)
Bit0
Description
S0
Reference used in PLL and PLL Status
Bit HA=1 when holdover history for the current reference is available. It will remain high when switched directly from the current
reference into holdover mode. Changing references, switching into free run, or setting the HOR bit in register 13h will clear the HA
bit. However, the valid holdover history will remain in the module’s memory until it is either overwritten by history from a new
reference, or until it is cleared by HOR.
When the module detects a 3.4 µ second phase-time change in 0.1s, it is unable to determine whether this is an actual
phase hit or a 34 ppm (or higher) frequency step. If phase build out is triggered due to a 34 ppm (or higher) frequency step, the
module will go into continuous phase build out. As the phase of the new frequency varies with the phase of the internal reference
from 0 degrees to 359 degrees and then back to 0, the phase build out bit in the pll status register (0Eh) will blink. The frequency of
this blinking will depend on the actual size of the frequency step
To prevent the module from going into a continuous phase build out state, do not attempt a 34 ppm (or greater) frequency
step unless phase build out is disabled.
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 13 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Table 15 - Reference Qualification Limits
Read/Write
Addrs
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Description
10h
RJ7
RJ6
RJ5
RJ4
RJ3
RJ2
RJ1
RJ0
Frequency rejection limit
11h
FQ7
FQ6
FQ5
FQ4
FQ3
FQ2
FQ1
FQ0
Frequency qualification limit
RJ7,RJ6,RJ5,RJ4,RJ3,RJ2,RJ1,RJ0 - Limit beyond which references always rejected (Default - 0001 1111 (+/-15.5 ppm))
FQ7,FQ6,FQ5,FQ4,FQ3,FQ2,FQ1,FQ0 - Limit below which references always qualified (Default - 0001 1001 (+/-12.5 ppm))
The Reference Qualification Limits registers hold the information used to determine the always reject and always qualify regions
for the references. For proper module operation, the minimum space between these numbers should be 3 ppm. The LSB of each of
these registers is 0.5 ppm, and the MSB is 64 ppm, so the max number is 127.5 ppm. The format is 2s complement, positive
numbers. Note that the qualification and rejection ranges are symmetrical so that +15.5 ppm in register 10h gives a frequency
rejection limit at + or - 15.5 ppm. See Figure 6 for further details.
Table 16 - Configuration
Read/Write
Addrs
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Description
12h
INT
X
X
SLV
X
CF3
CF2
CF1
Mode configuration register
13h
X
X
DPB
FRV
RST
HOR
REV
AUT
Feature configuration register
INT - When set to 1, INT selects internal user configuration data over the exter nal CNFG pins. (Default - 0)
SLV - When set to 1, the module is in slave mode. (Default - 0)
CF3,CF2,CF1 - Internal configuration pins, see Table 7 (Default - 000)
DPB - When set to 1, Phase Build Out is disabled. (Default - 1)
FRV - When set to 1, will choose priority of reference based on frequency offset rather than priority table. (Default - 0)
RST - Will internally reset the module when set to 1. (Default - 0)
HOR - Will reset Hold Over history when set to 1. Holdover history defaults to Free Run value when reset. (Default - 0)
REV - Selects revertive reference switching when set to 1. Revertive switching only occurs while in autonomous mode.
(Default - 0)
AUT - Select pin for autonomous mode. When set to 1, enables autonomous selection of modes. (Default - 0)
X - Reserved for future use. (Default - 0)
The Configuration registers are read/write registers that hold all of the configuration options for the device. If INT is set high, the
external pins CNTRL3:1 are ignored, and full user control is maintained through these two registers. Bits CF3:1 mimic pins
CNTRL3:1 operation, and SLV bit in the mode configuration register controls whether the unit acts as a master or slave module. For
complete master/slave operation, see Figure 5. The feature configuration register turns on and off optional features of the device
such as phase build out, revertive switching, and autonomous operation. Bits are also provided to judge priority of references
(applicable during autonomous mode only) based on their frequency offset (see registers 04h-09h) or on the priority table (see
registers 00h-02h). The module also allows a reset of Hold Over history (HOR), as well as a complete module reset (RST).
The RST bit is used to initiate a complete software reset. The proper procedure to reset the device is to write a 1 to RST and then
wait for the device to re-boot. This will reset the DSP, as well as the FPGA and DDS. Due to the complete reset, the output
frequencies will be temporarily disrupted while the programmable chips reinitialize and then the Free Run value will be reestablished.
All previous histories will be cleared. The registers will initialize as though following a power-up. Please note that there will be an
increase in current as the device reinitializes, but the current increase will stay below the stated datasheet maximum.
For optimal performance during master/slave operation, the slave unit should be configured the same as the master unit. This will
allow proper selection of input reference for the slave module in the event the signal from the master module is lost.
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 14 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Table 17 - Bandwidth Selection
Read/Write
Addrs
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Description
16h
FB3
FB2
FB1
FB0
X
X
X
X
Primary PLL Bandwidth selection
X
Slave mode Bandwidth selection
17h
SF3
SF2
SF1
SF0
X
X
X
FB3,FB2,FB1,FB0 - Selected bandwidth. See Table 23 (Default - 0011)
SF3,SF2,SF1,SF0 - Slave bandwidth. (Default - 0101, 20 Hz)
X - Reserved for future use. (Default - 0)
The bandwidth may be changed at any time during operation, even when the device is locked. However, the module may
experience a phase hit as the filters change bandwidth and so it is recommended to only change bandwidth upon initialization, or
when in Free Run or Hold Over modes.
If the bandwidth is changed to an undefined selection, no change in operation will occur. The initial bandwidth will remain in effect
until a valid new bandwidth is selected.
Slave mode bandwidth selection will take effect only when the unit is configured to be in slave mode. If the Slave Input reference
is lost (LOR), and the unit uses its configuration data to determine which reference to lock to, this bandwidth remains the same. The
purpose of the slave mode of operation is to lock to the master; if the master is lost, then the next best reference is used.
Table 18 - SPI Status
Read only
Addrs
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Description
18h
ER7
ER6
ER5
ER4
ER3
ER2
ER1
ER0
Error status
ER7,ER6,ER5,ER4,ER3,ER2,ER1 - SPI Error Status. See Table 24 (Default - 0000 0000)
The SPI Status register holds the state of the last SPI communication. An overrun error occurs when too many bytes of
information have been sent too quickly and the module was not able to process the address information before the clock started for
the data byte. Both reads and writes are invalid if this error follows their communication sequence. If an address error shows up in
this register, then the address that was sent to the module was invalid. No read or write will occur in this case. If an invalid address is
sent to the module, the module will still expect to see the SPI Enable line active and the SPI CLK line pulsed 8 times before the next
read/write cycle. All communication cycles are expected to be 2 bytes wide, whether there is an error or not. If an invalid data error is
displayed in the SPI Status register, it means that either a write was attempted on a read-only address, or an invalid data word was
written to an address. In either case, no data will be written into memory.
Table 19 - Identification
Read only
Addrs
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Description
19h
CI7
CI6
CI5
CI4
CI3
CI2
CI1
CI0
Customer Identification
1Ah
SI7
SI6
SI5
SI4
SI3
SI2
SI1
SI0
Software Model/Version Identification
1Bh
HI7
HI6
HI5
CI7, CI6, CI5, CI4, CI3, CI2, CI1, CI0
SI7, SI6, SI5, SI4, SI3, SI2, SI1, SI0
HI7, HI6, HI5, HI4, HI3, HI2, HI1, HI0
HI4
HI3
HI2
HI1
HI0
Customer Identification
Software Model/Version Identification
Hardware Model/Version Identification
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Hardware Model/Version Identification
Page 15 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Table 20 - Reference Status Table
R#1
R#0
Description
0
0
Reference is not present.
0
1
Reference is present but frequency is disqualified.
1
0
Reference is qualified but is unavailable.*
1
1
Reference is present and frequency is qualified.
* Reference is unavailable in autonomous mode when priority
register =0000 for that reference and FRV bit (register 13h) =0
Table 21 - Active Reference Table
R2
R1
R0
Description
0
0
0
No reference. Module is in Free Run or Hold Over
0
0
1
Tracking reference 1
0
1
0
Tracking reference 2
0
1
1
Tracking reference 3
1
0
0
Tracking reference 4
1
0
1
Tracking reference 5
1
1
0
Tracking reference 6
1
1
1
Module is locked to Slave input.
(Valid only in Slave mode)
Table 22 - Primary PLL State
S3
S2
S1
S0
Description
0
0
0
0
Loss of Lock
0
0
0
1
Acquisition Filter
0
0
1
0
Future Use
0
0
1
1
Future Use
0
1
0
0
Future Use
0
1
0
1
Future Use
0
1
1
0
Final Filter
0
1
1
1
Phase Build-Out
1
0
0
0
Hold Over
1
0
0
1
Free Run
Table 23 - Bandwidth Selecton
FB3
FB2
FB1
FB0
Description
0
0
1
1
0.1 Hz BW (S3 compatible)
Table 24 - SPI Status
ER7
ER6
ER5
0
0
0
ER4
0
ER3
0
ER2
0
ER1
0
0
SPI
0
0
0
0
0
0
1
0
SPI overrun error
0
0
0
0
0
0
1
1
SPI address error
0
0
0
0
0
1
0
0
SPI invalid data
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
ER0
SPI Status
Page 16 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Wander Generation TDEV
Figure 9
100
GR-1244-CORE, Fig. 5-4, GR-253-CORE, Fig 5-8,
Wander Generation TDEV
Wander Generation TDEV
TDEV (ns)
10
1
0.1
0.1
1
10
100
1000
10000
Integration Time (sec)
Wander Generation MTIE
Figure 10
1000
GR-1244-CORE, Fig 5-5, Wander Generation-MTIE
GR-253-CORE, Fig 5-17, MTIE for SONET clock
Wander Generation MTIE
MTIE (ns)
100
10
1
0.1
1
10
100
1000
10000
Observation Time (sec)
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 17 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Wander Transfer TDEV
Figure 11
10000
GR-1244-CORE, Fig 5-6, Stratum 3 Wander Transfer
Stratum 3 Calibrated Wander Transfer TDEV
1000
TDEV (ns)
100
10
1
0.1
0.01
0.1
1
10
100
1000
Integration Time (sec)
MTIE During Reference Rearrangement
Figure 12
10000
GR-1244-CORE, Fig. 5-7, Stratum 3/4E, Phase Transient during rearrangement
GR-253-CORE, Fig 5-19, MTIE for Phase Transients from SONET Clocks, Objective
and GR-1244-CORE, Fig. 5-7,Stratum 2/3E, Phase Transient during Rearrangment
Stratum 3 Reference Switch MTIE
MTIE (ns)
1000
100
10
1
0.001
0.01
0.1
1
Observation Time (sec)
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
10
Page 18 of 24
100
Rev: P00
1000
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Entry into Hold Over MTIE
Figure 13
1000
GR-1244-CORE, Fig 5-8, Phase Transient
Entry into Hold Over MTIE
MTIE (ns)
100
10
1
0.01
0.1
1
10
100
1000
Observation Time (sec)
1µ
µ s Phase Transient MTIE
Figure 14
10000
GR-1244-CORE, Fig 5-9, MTIE mask for I/O Phase Transient
GR-253-CORE, Fig 5-19, MTIE for Phase Transients from SONET Clocks, Requirement
1us Phase Transient MTIE
MTIE (ns)
1000
100
10
1
0.001
0.01
0.1
1
10
Observation Time (sec)
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
100
Page 19 of 24
1000
Rev: P00
10000
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Jitter Attenuation
Figure 15
10
0
-3
Slave Mode
Jitter attenuation (-dB)
-10
-20
-30
-40
Master Mode
-50
-60
-70
0.001
0.01
0.1
1
INPUT Jitter frequency (Hz)
10
100
*See Table 17 and Table 23 for Bandwidth selections
Hold Over Stability over Temperature
Figure 16 180
160
140
PPB
120
100
80
60
40
20
0
-20
70
60
50
40
30
20
10
0
Temperature (°C)
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 20 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Typical Current Consumption Over Temperature
Figure 17 0.700
0.600
Currnet (Amps)
0.500
0.400
0.300
0.200
0.100
0.000
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
Temperature (°C)
Typical Phase Build Out MTIE
Figure 18
(Disabled by default for Stratum 3 compliance)
100.0E-9
MTIE (ns)
10.0E-9
1.0E-9
100.0E-12
1.0E-3
10.0E-3
100.0E-3
1.0E+0
Observation Window (Tau)
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
10.0E+0
Page 21 of 24
Rev: P00
100.0E+0
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Mode and Alarm Timing Diagram
Figure 19
State Change on Control Input Pins
(CNTRL1-3)
Operational Mode Indicators
(Ref1-Ref6, Hold Over or Free Run)
Alarm Indicator
(See Operation Overview for
details on Alarm Operation)
2 ms < ∆t < 4 ms
LOCK Timing Diagram
Figure 20
Internal 8kHz
(Derived from Sync_Out)
External 8kHz
(Derived from Active Reference)
Internal Phase
Error Signal
≤20
µs
>20
µs
>20
µs
>20
µs
tdelay
≥ 2ms
Lock Indicator
tdelay
0ms ≤ tdelay ≤ 2ms
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 22 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
Package Dimensions
Figure 21
.110 [2.80mm]
1.820 [46.23mm]
SQUARE
MAX.
1.600 [40.64mm]
.160 ±0.008 [4.06mm]
PIN 1
.700 [17.78]
MAX.
.075 [1.90]
MIN.
.100 [2.54mm]
.110 [2.81mm]
.020 [.51mm]
*Please consult the factory for alternate pin connector lengths.
Footprint and Keepout Dimensions
Figure 22
Preliminary Data Sheet #: TM055
© Copyright 2004 The Connor-Winfield Corp.
Page 23 of 24
Rev: P00
Date: 5/17/04
All Rights Reserved Specifications subject to change without notice
2111 Comprehensive Drive
Aurora, Illinois 60505
Phone: 630- 851- 4722
Fax: 630- 851- 5040
www.conwin.com
Revision #
Revision Date
Notes
P00
05/17/04
Preliminary informational release