MEN 0-30A

CLASS "MISC" MIDGET FUSES
TIME-DELAY
Catalog No. MEQ (.1 - 30A)
500 Volts AC or Less
Time-Delay
0.1
0.125
0.15
0.2
0.25
0.3
0.4
0.5
Amps
.1 - 30
AMPERE RATINGS
MEQ 500V
0.6
2.25
5.6
0.8
2.5
6
1
3
6.25
1.125
3.2
7
1.25
3.5
8
1.5
4
9
1.6
4.5
10
2
5
12
DIMENSIONS
Ferrule (in)
13/32
15
20
25
30
—
—
—
—
Length (in)
1-1/2
Catalog No. MEN (.1 - 30A)
250 Volts AC or Less
Time-Delay
0.1
0.15
0.2
0.25
0.3
0.4
0.5
0.6
Amps
.5 - 30
AMPERE RATINGS
MEN 250V
0.8
2
4.5
1
2.25
5
1.125
2.5
5.6
1.25
2.8
6
1.4
3
6.25
1.5
3.2
7
1.6
3.5
8
1.8
4
9
DIMENSIONS
Ferrule (in)
13/32
10
12
15
20
25
30
—
—
Length (in)
1-1/2
MEQ SPECIFICATIONS
Time-Delay
MEN SPECIFICATIONS
Time-Delay
Voltage Rating: MEQ - 500VAC
Ampere Rating: .1 - 30 Amps
Interrupting Rating: 10K RMS Amps
Agency Approvals:
(.1 - 30) UL Listed to 198G, File E162443
(.1 - 30) CSA Cert. C22.2 Part 59.2,
LR700489
Voltage Rating: MEN - 250VAC
Ampere Rating: .5 - 30 Amps
Interrupting Rating: 10K RMS Amps
@ 125V
Agency Approvals:
UL Listed to 198G, File E162443
CSA Cert. C22.2 Part 59.2, LR700489
BENEFITS:
• Compact dimensions.
• Fiber tube construction.
• Time-delay allows harmless inductive surges to pass without needless
fuse opening.
BENEFITS:
• Compact dimensions.
• Fiber tube construction.
• Dual-element construction allows
harmless inductive surges to pass
without opening.
APPLICATIONS:
• Supplemental protection of transformers, solenoids, and other high
inrush circuits.
• For motor applications, refer to EDCC.
APPLICATIONS:
• Supplemental protection of small
motors, transformers, solenoids, and
other high inrush power electronic
circuits.
RECOMMENDED FUSEBLOCKS:
Refer to page 142 in this catalog.
RECOMMENDED FUSEBLOCKS:
Refer to page 142 in this catalog.
EDISON
CROSS REFERENCE
BUSS
GOULD
LF
MEQ
FNQ
FLQ
ATQ
0.1
0.15
0.2
0.3
0.4
0.5
0.6
0.8
Amps
.1 - 30
AMPERE RATINGS
1
2.25
5.6
1.125
2.5
6
1.25
2.8
6.25
1.4
3
7
1.5
3.2
8
1.6
3.5
9
1.8
4
10
2
5
12
DIMENSIONS
Ferrule (in)
13/32
15
20
25
30
—
—
—
—
Length (in)
1-1/2
NOTE: 12-30 amp is dual-tube construction.
EDISON
CROSS REFERENCE
BUSS
GOULD
LF
MEN
FNM
FLM
TRM
Catalog No. MID (.1 - 30A)
.1 - .8A 250 Volts AC or Less
1 - 15A 125 Volts AC or Less
20 - 30A 32 Volts AC or Less
Pin Indicating - Time-Delay
MID SPECIFICATIONS
Pin Indicating — Time-Delay
Voltage Rating: .1 - .8 Amps; 250VAC
1 - 15 Amps; 125VAC
20 - 30 Amps; 32VAC
Ampere Rating: .1 - 30 Amps
Interrupting Rating:10K RMS Amps
@ 125V
Agency Approvals:
UL Listed to 198G, File E162443
CSA Cert. C22.2 Part 59.2, LR700489
BENEFITS:
• Compact dimensions.
• Silver-plated pin indicates when fuse
is opened. Provides positive electrical signal activation.
APPLICATIONS:
• Supplemental protection for high
inrush power electronic circuits.
RECOMMENDED FUSEBLOCKS:
Refer to page 142 in this catalog.
EDISON
MID
CROSS REFERENCE
BUSS
GOULD
FNA
GFN
LF
FLA
33
CLASS "MISC" MIDGET FUSES
TIME-DELAY
AVERAGE TIME/CURRENT CURVE
1/2A
AMPERE
RATING
100
80
100
80
60
60
50
40
40
30
30
20
AMPERE
RATING
1A
7-1/2
Cat. No. MEN (Amp)
5
3
1
1/2
Cat. No. MEQ (Amp)
20
10
8
10
6
5
4
TIME IN SECONDS
8
6
TIME IN SECONDS
4
3
2
1
3
2
1
.8
.6
.5
.4
.3
.8
.2
.6
.4
.1
.08
.3
.06
.05
.04
.2
.03
.02
.1
300
200
40
50
60
80
100
30
20
400
500
600
800
1,000
.04
4
5
6
8
10
3
2
.01
.06
1
.08
RMS SYMMETRICAL CURRENT IN AMPERES
.03
20A
15A
10A
5A
AMPERE
RATING
100
80
200
80
100
3A
1A
RMS SYMMETRICAL CURRENT IN AMPERES
60
40
30
20
8
10
6
4
3
2
.8
1
.6
.4
.01
2A
Cat. No. MID (Amp)
.02
60
50
1/2A
40
30
20
10
8
TIME IN SECONDS
6
5
4
3
2
1
.8
.6
.5
.4
.3
.2
.1
.08
.06
.05
.04
.03
300
200
40
50
60
80
100
30
20
4
5
6
8
10
3
400
500
600
800
1,000
34
2
.01
1
.02
RMS SYMMETRICAL CURRENT IN AMPERES