Telcom Protection Devices

Telcom Protection
Products
Section Contents
Page
Telpower® compact fused disconnect switches . . . . .388
Telpower miniature fused disconnect switches . . . . 389
Fused disconnect switches for TPA fuses
TP15914 4-Pole disconnect switch . . . . . . . . . . . . . . . .390
TP11590-4 4-Pole disconnect switch . . . . . . . . . . . . .391
TPA & TPA-B Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . .391
Fused disconnect switches for TPS fuses
15800 1-Pole fused disconnect switch . . . . . . . . . . . . .392
TPS Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392
Fused disconnect switches
TP158HC panel mount, rear access switch . . . . . . . . .393
15100 1-Pole switch for use with TPL fuses . . . . . . . .394
15200 1-Pole switch for use with TPL fuses . . . . . . . .394
TPHCS Telpower high-current switch . . . . . . . . . . . .395
TPL Telpower 70-600A: 170Vdc fuses . . . . . . . . . . . .396
TPN Telpower 1-600A: 170Vdc fuses . . . . . . . . . . . .397
70 Series Indicating fuses . . . . . . . . . . . . . . . . . . . .398
15087 Fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . .398
HLS, HLT & PCT fuse holders . . . . . . . . . . . . . . . . . .399
GMT Fast acting fuses . . . . . . . . . . . . . . . . . . . . . . . .399
GMT-A Fast acting fuse . . . . . . . . . . . . . . . . . . . . . . .399
Telpower specialty fuses
7 Type Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400
11 Type Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400
24 & WER Type non-indicating, visible link fuses . . . .400
74 Type Fast acting fuses . . . . . . . . . . . . . . . . . . . . . . .400
75 Type Cylindrical fuses with leads . . . . . . . . . . . . . . .401
76 Type Cylindrical fuses with leads . . . . . . . . . . . . . . .401
80 Type visual indicating fuses . . . . . . . . . . . . . . . . . . .401
81 Type Fast acting, non-indicating fuses . . . . . . . . . . .401
Filtered terminal blocks
F38 Series 2- to 8-Pole block . . . . . . . . . . . . . . . . . . . .402
Power feed through terminal blocks
387
Telcom
Protection
Products
Series C7021 2- to 6-Pole block . . . . . . . . . . . . . . . . . . 403
Series C7024 1- to 12-Pole block . . . . . . . . . . . . . . . . .404
Telcom Protection Products
Telpower® Compact Fused Disconnect Switches
Catalog Numbers
TPC & TPCDS
Specifications
Descriptions:
— TPC: Telpower®
compact currentlimiting fuses.
— TPCDS: Telpower
compact fused
disconnect switch
available in two
disconnect switch profiles in addition to a variety of
terminal styles. Recommended 0.75” center-to-center
product spacing.
Dimensions: See Data Sheet 5023.
Ratings:
Volts: — 80Vdc
Amps: — 3-125A (See Catalog Numbers table for details)
IR: — 100kA
Agency Information: CE, UL Recognized (investigated to
UL 1801) as a disconnect switch for the interruption of load
current by means of withdrawing the fuse pullout.
Recognized to US and Canadian requirements under the
component recognition program of Underwriters Laboratories
Inc. Files E219046 and E56412.
Flammability Ratings: Fuse UL 94V0, 170°C RTI,
Housing UL 94V0, 120°C RTI.
TPCS disconnect switch
Catalog
Amp
Numbers
Range
TPCDS-BBE-1
3-125
TPCDS-BBE-2
3-125
TPCDS-BBE-3
3-125
TPCDS-BBM-1
3-125
TPCDS-BBM-2
3-125
TPCDS-BBM-3
3-125
TPCDS-BSE-1
3-125
TPCDS-BSE-2
3-125
TPCDS-BSE-3
3-125
TPCDS-BSM-1
3-125
TPCDS-BSM-2
3-125
TPCDS-BSM-3
3-125
TPCDS-SSE-1
3-125
TPCDS-SSE-2
3-125
TPCDS-SSE-3
3-125
TPCDS-SSM-1
3-125
TPCDS-SSM-2
3-125
TPCDS-SSM-3
3-125
TPCDS-D-BC1*
3-125
TPCDS-D-BC2*
3-125
TPCDS-D-CC1*
3-125
TPCDS-D-SEC1* 3-125
TPCDS-D-SEC2* 3-125
TPCDS-D-SMC1* 3-125
TPCDS-D-SMC2* 3-125
*Not investigated to Canadian Requirements.
Features and Benefits
• Highest interrupting rating (100kA) available and
complete system coordination for dc circuit protection for
compact footprint providing a superior protection solution
for replacement of existing dc telecom circuit breakers
• AmpColor ID™ System makes fuse replacement easy
• Local and remote open fuse indication. Local alarm
indication provided by LED on TPC fuse
• Remote alarm terminal available in three positions
common to dc circuit protection devices
Typical Applications
• Telecommunications DC power circuit protection
• Replacement of DC telecom circuit breakers
• Applications where venting of arc or molten metals and
gases during opening would pose a problem to surrounding
devices
Data Sheet: 5023
388
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
TPC Current-Limiting Fuse
Catalog
Amp
Numbers
Rating
TPC-3
3
TPC-4
4
TPC-5
5
TPC-6
6
TPC-7
7
TPC-8
8
TPC-10
10
TPC-12
12
TPC-15
15
TPC-20
20
TPC-25
25
TPC-30
30
TPC-40
40
TPC-50
50
TPC-60
60
TPC-75
75
TPC-90
90
TPC-100
100
TPC-125
125
Telcom Protection Products
Telpower Miniature Fused Disconnect Switches
Catalog Numbers
TPM &
TPMDS
Specifications
Description:
— TPM:
Telpower
miniature currentlimiting fuses.
— TPMDS:
Telpower
miniature fused
disconnect switch.
Dimensions: See Data Sheet 5022.
Ratings:
Volts: — 80Vdc
Amps: — 3-30A
IR: — 20kA
Agency Information: CE, UL Recognized (investigated to
UL 1801) as a disconnect switch for the interruption of load
current by means of withdrawing the fuse pullout.
Recognized to US and Canadian requirements under the
component recognition program of Underwriters Laboratories
Inc. Files E219046 and E56412.
Flammability Ratings: Fuse UL 94V0, 170ºC RTI; Switch
UL 94V0, 140ºC RTI.
Typical Applications
• Telecommunications DC power circuit protection
• Applications with restricted space, or mounting in 1 U panels
Description
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Disconnect, English hardware
Disconnect, Metric hardware
Amp
Rating
3
4
5
6
7
8
10
12
15
20
25
30
3-30
3-30
TPM Alarm Schematic
NOTES:
1. The resistance, R, must be provided by the end-user to
limit the alarm output current to a maximum of 20mA. The
value, R, should be calculated using the system voltage
value.
• If remote alarm functionality is not required, the END-USER
CIRCUITRY must still be supplied to provide a resistive path
to the return for the local alarm to properly function.
2. The fuse is polarized to maintain proper orientation with
the switch housing. The line and load terminals are identified
on the switch housing.
Data Sheet: 5022
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
389
Telcom
Protection
Products
Features and Benefits
• Smallest and most versatile fused disconnect switch
available allowing for assembly into 1 U (1.75”/44.5mm)
panel. Easy to connect; Load: 1⁄4” quick-connect or bolted
connection with 10-32 (M5) captive nut, Line: 1⁄4” quickconnect or screw connection with clearance hole for
#10 (M5) bolt.
• AmpColor ID™ System makes fuse replacement easy
• Switch design provides for easy panel mounting by single
captive 4-40 (M3) nut and panel notch integral to switch
footprint.
• Complete system coordination capability with local and
remote open fuse indication. Local alarm indication
provided by LED on TPM fuse (maximum alarm circuit
current: 20mA)
Catalog
Numbers
TPM-3
TPM-4
TPM-5
TPM-6
TPM-7
TPM-8
TPM-10
TPM-12
TPM-15
TPM-20
TPM-25
TPM-30
TPMDS-E
TPMDS-M
Telcom Protection Products
Fused Disconnect Switches for TPA Fuses
Dimensions mm/in
TP15914
Specifications
Description:
Modular 4-pole
disconnect switch
for TPA Series
fuses — 4-poles
per module up to
four modules
ganged together.
Features open fuse
indication and fuse presence indication along with fuse
orientation rejection feature.
Dimensions: See Dimensions illustrations.
Ratings:
Volts: — 145Vdc
Amps: — 50A per pole
Agency Information: CE, UL Recognized as a disconnect
switch for interruption of load current by means of
withdrawing the fuse carrier. UL Recognized as a component
for telecommunication power distribution equipment (UL
category QPQYZ), UL Recognized fuses for branch circuit
protection, CSA component acceptance for the system. UL
Recognized, Guide JFHR2, File E56412., CSA Certified,
Class 1422-30, File 53787.
Flammability Rating: UL 94V0, 140°C.
Features and Benefits
• Totally enclosed module directly connects to busbar for
reduced external wiring—per pole and easy installation
with front access load and line connection standard—
double lug load connections 8 AWG wire
• LED alarm signaling (LED current 30mA max)
• Remote alarm with alarm test probe point to allow on-site
checking of alarm circuitry
• Bi-polar LED provides capability for both –48Vdc and
+24Vdc applications
0.745
0.284
1.5
0.215
1.5
0.625
3.57
4.27
TOP
76.07
3.0
Accessories
• Spare fuse holders: Catalog Numbers 5TPH and TPSFH-A
Typical Applications
• Telecommunications DC power circuit protection
Catalog Numbers
Catalog
Numbers
TP15914
TP15914-1
Hardware
English
Metric
Data Sheet: 5011
390
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
Telcom Protection Products
Fused Disconnect Switches for TPA Fuses
TPA & TPA-B
TP15900-4
Specifications
Description: 4-pole
disconnect switch for
use with Telpower
fuses Type TPA &
TPA-B.
Dimensions: See Dimensions illustrations.
Ratings:
Volts: — 145Vdc (40A)
— 80Vdc (50A)
Amps: — 40A@145Vdc
— 50A@80Vdc
Agency Information: CE, UL Recognized File E97649 as
a disconnect switch for interruption of load current by means
of withdrawing the fuse carrier. UL Recognized as a
component for telecommunication power distribution
equipment (UL category QPQY2). UL Recognized fuses for
branch circuit protection. CSA Component Acceptance for
the system.
Flammability Rating: UL 94V0, 140°C.
Features and Benefits
• Ease of installation - connection directly to busbar,
reduces external wiring per pole. Rear accessibility for line
and load terminations
• LED alarm signaling (LED current 30mA max)
• Local and remote open-fuse indication along with fuse
orientation rejection feature and fuse presence indication
• Alarm test probe point, to allow on-site checking of alarm
circuitry
Typical Applications
• Telecommunications DC power circuit protection
Catalog Numbers
Catalog
Numbers
Description
TP15900-4 4-Pole common disconnect switch
TP15900-41 4-Pole common disconnect switch w/ Split Alarm, Split Line
Specifications
Description: DC power distribution
indicating fuses.
Dimensions: See Dimensions illustration.
Ratings:
Volts: — 170Vdc TPA
— 65Vdc TPA-B
Amps: — 3-50A TPA
— 20-30A TPA-B
IR: — 100kA TPA
— 20kA TPA-B
Agency Information: CE, UL Recognized, Guide JFHR2,
File E56412, CSA Certified, Class 1422-30, File 53787.
Features and Benefits
• Indication pin provides for local and remote indication when
used with Cooper Bussmann® TP15900-4 and TP15914
disconnect switches
• Patented “orange ring” fuse orientation features assures
correct fuse position
• The UL Recognized ratings and current-limiting capability
make this fuse ideal for cable protection on existing DC
power distribution systems
• A unique blue label is used on all Telpower fuses to
designate their DC capability
Typical Applications
• Telecommunications DC power circuit protection
Catalog Numbers (Amps)
Catalog
Numbers
TPA-3
TPA-5
TPA-10
TPA-15
TPA-20
TPA-25
Amp
Rating
3
5
10
15
20
25
Catalog
Numbers
TPA-30
TPA-40
TPA-50
TPA-B-20
TPA-B-25
TPA-B-30
Amp
Rating
30
40
50
20
25
30
Dimensions - mm (in)
Telcom
Protection
Products
Dimensions - mm (in)
Accessories
• Spare fuse holders: 5 position holder; 5TPH; 6 position
holder; TPSFH-AS
• Use with fused disconnect switches TP15900-4, TP15914
Accessories
• Spare fuse holders: Catalog Numbers 5TPH and
TPSFH-AS.
Data Sheet: 5001
Data Sheet: 5012
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
391
Telcom Protection Products
Fused Disconnect Switches for TPS Fuses
TPS
15800
Specifications
Description:
Fused disconnect
switch for use only
with the following
fuses; Main: Telpower®
TPS 3 to 70 Amp,
Alarm: Cooper Bussmann
GMT-A only (page 399).
Recommend GMT-X Cover
(page 399).
Dimensions: See Dimensions illustration.
Ratings:
Volts: — 60Vdc
Amps: — 3-70A
SCCR: — 100kA
Agency Information: CE, UL Recognized, Guide QPQY2,
File E97649.
Flammability Rating: UL 94V0, 150°C.
Features and Benefits
• Alarm output with wire wrap terminal or connection to 0.063”
thick common alarm bus
• Spare alarm and power fuse compartment
• Mounting hardware included
Typical Applications:
• Telecommunications DC power circuit protection
Features/Benefits
• The UL Recognized ratings and current-limiting capability
make this fuse ideal for cable protection on existing DC
power distribution systems
• A unique blue label is used on all Telpower fuses to
designate their DC capability
• Printed circuit board variations available
Typical Applications
• Telecommunications DC power circuit protection
• Applications requiring printed circuit board mounting
Catalog Numbers (Amps)
TPS-1
TPS-1L
TPS-2
TPS-2L
TPS-3
TPS-3L
TPS-5
TPS-5L
TPS-6
Catalog Numbers
Catalog
Numbers
15800-R-200
15800-F-200
Specifications
Description: DC
power distribution
non-indicating fuses
specifically designed to
meet the unique needs
of DC power distribution systems. For use with Cooper
Bussmann® fused disconnect switch 15800.
Dimensions: See Dimensions illustration.
Ratings:
Volts: — 170Vdc
Amps: — 1-70A.
IR: — 100kA
Agency Information: CE, UL Recognized, Guide JFHR2,
File E56412.
Access Panel Mounting
Rear
Front
Dimensions - in (mm)
TPS-6L
TPS-10
TPS-10L
TPS-15
TPS-15L
TPS-20
TPS-20L
TPS-25
TPS-25L
TPS-30
TPS-30L
TPS-35
TPS-35L
TPS-40
TPS-40L
TPS-40V
TPS-50
TPS-50L
TPS-50V
TPS-60
TPS-60L
TPS-70
TPS-70L
TPS-70LB
Dimensions - in (mm)
72 lb-in
Accessories
• Spare fuse holder: TPSFH-AS, see page 414.
Accessories
• Spare fuse holders: Catalog Numbers TPSFH-AS (TPS
fuses) and TPSFH-T (GMT fuses).
Data Sheet: 5002
392
Data Sheet: 5009
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
Telcom Protection Products
Fused Disconnect Switches
TP158HC
Specifications
Description: Panel mount, rear
access high amp version of
Cooper Bussmann® 15800 series
fused disconnect switch for use
only with the following fuses;
Main: Telpower TPL-B 70-250
Amps, Alarm: Cooper Bussmann
GMT-A.
Dimensions: See Data Sheet
5021.
Ratings:
Volts: — 80Vdc
Amps: — 70-250A
SCCR: — 100kA
Agency Information: UL Recognized (investigated to UL
1801) as a disconnect switch for the interruption of load
current by means of withdrawing the fuse pullout. Guide
QPQY2, File E97649.
Flammability Rating: UL 94V0, 150°C.
Application Notes
• The line connection uses a 1⁄4-20 bolt (metric – M6X1) that
threads into the line terminal. The line terminal is designed
with a float of ±0.02” (± 0.50mm) to allow for variation in the
distance between the TP158HC mounting flange and the
line busbar (see Dimensions). Equipment should be
designed to eliminate any relative movement between the
TP158HC mounting flange and the line busbar.
• The alarm circuit is not intended for precharging of
capacitive circuits. Alarm circuit current 1A maximum.
Easy Fuse Replacement
Features and Benefits
• Similar profile, mounting method, and backplane
configuration as 15800 Series. The TP158HC can be
installed into existing 15800 Series panels using the space
of two 15800 disconnects
• Innovative new fuse pullout design eliminates need for
tools to replace the Telpower type TPL-B fuse
• Alarm output with wire wrap terminal or connection to
0.063 inch (1.6mm) thick common alarm bus
• Hardware included: Load: washer, split lockwasher, and
5
⁄16 - 18 nut (metric-M8 x 1.25)
Typical Applications:
• Telecommunications DC power circuit protection
Catalog Numbers
Hardware
English
Metric
Telcom
Protection
Products
Catalog
Numbers
TP158HC
TP158HC-M
Accessories
• Spare fuse holders: TPSFH-LB (TPL-B fuses) and TPSFH-T
(GMT fuses).
Data Sheet: 5021
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
393
Telcom Protection Products
Fused Disconnect Switches
15100
15200
Specifications
Description: Fused
disconnect system for use with
Telpower fuses Type TPL.
Dimensions: See Dimensions
illustrations.
Ratings:
Volts: — 60Vdc
Amps: — 70-800A
SCCR: — 100kA
Agency Information: CE, UL Recognized, Guide QPQY2,
File E97649.
Specifications
Description: Fused disconnect
system for use with Telpower
fuses Type TPL.
Dimensions: See Dimensions
illustrations.
Ratings:
Volts: — 60Vdc
Amps: — 70-800A
SCCR: — 100kA
Agency Information: CE, UL Recognized, Guide QPQY2,
File E97649.
Features and Benefits
• Single-pole fusible disconnect switch for primary DC power
distribution
• Robust housing and terminal construction for demanding
applications
• Panel mounting
• Easily connected to line or load bus
Features and Benefits
• Fusible disconnect transfer switch for primary DC power
distribution
• Robust housing and terminal construction for demanding
applications
• Panel mounting
• Easily connected to line or load bus
Typical Applications
• Telecommunications DC power circuit protection
Typical Applications
• Telecommunications DC power circuit protection
Catalog Numbers
Catalog
Numbers
15100-401
15100-601
Catalog Number
For Use With
TPL Series Fuses
70-400A
300-800A
Catalog
Number
15200-602
For Use With
TPL Series Fuses
70-800A
Dimensions - in (mm)
Dimensions - in (mm)
6.75"
(171.45mm)
3"
1"
(76.2mm)
(25.4mm)
3"
4"
(76.2mm)
(101.6mm)
5.86"
(149.22mm)
8.69"
(220.66mm)
0.27" (6.75mm) Dia. Hole with 0.5" (12.7mm)
Dia. x 0.16" (3.97mm) Deep C'bore (4 Holes)
2"
0.88"
5.75"
(50.8mm)
(22.22mm)
(146.05mm)
#14 Thd.
1.88"
(47.62mm)
7.25"
(184.15mm)
3.63"
(92.07mm)
0.31" (7.93mm) #18 Tap x 0.5" (12.7mm) Deep (4 Holes)
2.75"
(69.85mm)
7.13"
(181.10mm)
5"
6.75"
(127.0mm) (171.45mm)
0.5"
11"
1.31"
(33.33mm)
(279.4mm)
2.63"
(66.67mm)
12"
5.25"
(304.8mm)
(133.35mm)
Data Sheet: 5003
394
Data Sheet: 5004
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
(12.7mm)
Telcom Protection Products
Telpower® High-current Switch
Catalog Numbers – Switches (Pullout and Base)
Amp
Rating
70-250
70-250
70-250
70-250
70-250
70-250
300-800
300-800
300-800
300-800
300-800
300-800
Catalog Numbers – Components
Catalog
Numbers
TPHCS250-P
TPHCS800-P
TPHCS-B-M
TPHCS-B-E
TPHCS-B-ML
TPHCS-B-EL
TPHCS-B-MAV
TPHCS-B-EAV
Description
Rating/Hardware/Option
Pullout only – 250A
Pullout only – 800A
Base only, Metric
Base only, English
Base only, Metric, LED
Base only, English, LED
Base only, Metric, Alarm
Base only, English, Alarm
Fuse
Series
TPL-B
TPL-C or TPH
—
—
—
—
—
—
Amp
Rating
70-250
300-800
800 Max
800 Max
800 Max
800 Max
800 Max
800 Max
Dimensions mm (in)
Ø 7.62
(0.300)
Type. 4
41.02
(1.615)
L
L
L
66.4
(2.62)
L
L
25.9
(1.02)
L
L
122.43
(4.820)
L
L
8.8
(0.34)
L
22.2
(0.88)
L L
12.7
(0.50)
L
17.3
(0.68)
L
L
L
L
L
100.5 REF
(3.96)
74.6
(2.94)
13.2
(0.52)
L
Threaded Insert, 4 Places
M8x1.25 (-M Series) 5/16-18 (-E Series)
Recommended Torque 15N • m (11 Ft-lb)
24.8 REF
(0.98)
L
L
L
L
L
L
L
Telcom
Protection
Products
L
105.2
(4.14)
139.7
(5.50)
L
See table for part
number format
L
Typical Applications
• Telecommunications DC power circuit protection
• Compact design is ideal for today’s high power,
high-density cabinets
Fuse
Series
TPL-B
TPL-B
TPL-B
TPL-B
TPL-B
TPL-B
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
L
Features and Benefits
• Innovative design eliminates need for tools to replace the
Telpower® Type TPL-B, TPL-C or TPH fuse
• Easy to install–captive fasteners allow for direct busbar
mounting (bolts not included). Standard 1⁄4” male quickconnect terminal for effortless remote alarm connection.
• Optional new electronic alarm eliminates need for parallel
indicating fuses while providing local and remote openfuse indications (maximum remote alarm current: 20mA);
Bipolar alarm: designed for both Central Office and Radio
applications, Local LED alarm indication for
ease-of-viewing.
• Fuse presence window allows for easy viewing of installed
fuse amp rating
Hardware/
Option
Metric
English
Metric, LED
English, LED
Metric, Alarm
English, Alarm
Metric
English
Metric, LED
English, LED
Metric, Alarm
English, Alarm
L
Specifications
Description: High
current switch for
use with Telpower
fuses Type TPL-B,
TPL-C and TPH.
Available as
complete switch or pullout.
TPHCS800-MAV (shown)
Base may be purchased
separately.
Dimensions: See Dimensions illustrations.
Construction:
Ratings:
Volts: — 80Vdc
Amps: — 70-800A
SCCR: — 100kA
Agency Information: UL Recognized (investigated to UL
1801) as a disconnect switch for the interruption of load
current by means of withdrawing the fuse carrier. UL
Recognized to meet the requirements for Canadian
Standards.
Catalog
Numbers
TPHCS250-M
TPHCS250-E
TPHCS250-ML
TPHCS250-EL
TPHCS250-MAV
TPHCS250-EAV
TPHCS800-M
TPHCS800-E
TPHCS800-ML
TPHCS800-EL
TPHCS800-MAV
TPHCS800-EAV
L
TPHCS
Tin-Plated
Copper
Terminals
L
L
61.47
(2.420)
L
L
39.2 REF
(1.54)
L
16.76
(0.660)
NOTES:
1. TPHCS250 and TPHCS800 pullouts and bases are the same with exception to the type of
fuse, TPL-B, TPL-C or TPH the pullout will carry.
2. Plastic rated UL 94V0, 140ºC RTI.
Data Sheet: 5020
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
395
Telcom Protection Products
Telpower® 70-600A: 170Vdc Fuses
Dimensions - in (mm)
TPL
Specifications
Description: DC power distribution
fuses for use with Telpower 15100,
15200, TP158HC and TPHCS
disconnect systems. For replacement of
Cooper Bussmann UBO fuses a TPL-TA
adapter kit is necessary.
Dimensions: See Dimensions
illustrations.
Ratings:
Volts: — 170Vdc
Amps: — 70-800A
IR: — 100kA
Agency Information: CE, UL Recognized Guide JFHR2,
File E56412 Bellcore.
Features and Benefits
• Current-limiting capability designed for DC power
distribution systems
• Recognized branch circuit protection
• Complete system coordination capability
• Energy savings with low watts loss, low operating
temperatures, and minimum I2t levels
2.66"
(67.5mm)
2.19"
(55.6mm)
1.91"
(48.4mm)
1.0"
1.16"
(25.4mm)
(29.4mm)
BUSS
0.75"
(19.1mm)
TPL–BL
0.33"
0.19"
(8.3mm)
(4.8mm)
TPL-BA, TPL-BD, TPL-BF, TPL-BH, TPL-BK, and TPL-BL
3.50"
(88.9mm)
2.44"
(61.9mm)
1.50"
1.25"
(38.1mm)
(31.8mm)
BUSS
1.00"
(25.4mm)
TPL–CZ
0.41"
(10.3mm)
TPL-CN, TPL-CR, TPL-CV, and TPL-CZ
Typical Applications
• Telecommunications power circuit protection
Catalog Numbers
Catalog
Numbers
Amp
Rating
TPL-BA
70
TPL-BB
80
TPL-BC
90
TPL-BD
100
TPL-BE
125
TPL-BF
150
TPL-BG
175
TPL-BH
200
TPL-BK
225
TPL-BL
250
TPL-CN
300
TPL-CO
350
TPL-CR
400
TPL-CU
450
TPL-CV
500
TPL-CZ
600
TPL-CZH
800
Accessories
• Spare fuse holders: TPSFH-LB (for TPL-B fuses)
TPSFH-LC (for TPL-C fuses)
Data Sheet: 5005
396
0.25"
(6.4mm)
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
Telcom Protection Products
Telpower® 1-600A, 170Vdc Fuses
TPN
Dimensions - in (mm)
Specifications
Description: Currentlimiting DC power
distribution fuses. The
TPN fuse series is
dimensionally similar to
Class R fuses making it
easy to use standard
Class R fuse blocks.
Dimensions: See Dimensions illustrations.
Ratings:
Volts: — 170Vdc
Amps: — 1-600A
IR: — 100kA
Agency Information: UL Recognized, Guide JFHR2, File
E56412.
Features/Benefits
• Current-limiting capability designed for DC power
distribution systems
• Recognized branch circuit protection
• Complete system coordination capability
• Energy savings with low watts loss, low operating
temperatures, and minimum I2t levels
Typical Applications
• Telecommunications power circuit protection
Catalog Numbers (Amps)
TPN-1
TPN-3
TPN-5
TPN-6
TPN-10
TPN-15
TPN-20
TPN-25
TPN-30
TPN-35
TPN-40
TPN-45
TPN-50
TPN-60
TPN-70
TPN-80
TPN-90
TPN-100
TPN-110
TPN-125
TPN-150
TPN-175
TPN-200
TPN-225
TPN-250
TPN-300
TPN-350
TPN-400
TPN-450
TPN-500
TPN-600
0.56"
(14.3mm)
2"
(50.8mm)
1A to 30A
0.81"
(20.6mm)
3"
(76.2mm)
35A to 60A
5.88"
(149.2mm)
1.00"
(25.4mm)
70A to 100A
7.13"
(181.0mm)
1.50"
(38.1mm)
110A to 200A
8.63"
(219.1mm)
2.00"
(50.8mm)
225A to 400A
10.38"
(263.5mm)
2.50"
(63.5mm)
450A to 600A
Accessories
• Spare fuse holders:TPSFH-N30 (for TPN 1-30) TPSFH-N60
(for TPN 35-60)
Recommended Class R Fuse Blocks
Poles
1
2
3
1
2
3
1
2
3
1
3
1
3
1
3
Catalog
Number
R25030-1CR
R25030-2CR
R25030-3CR
R25060-1CR
R25060-2CR
R25060-3CR
R25100-1CR
R25100-2CR
R25100-3CR
R25200-1CR
R25200-3CR
R25400-1CR
R25400-3CR
R25600-1CR
R25600-3CR
Telcom
Protection
Products
Amps
1-30
1-30
1-30
35-60
35-60
35-60
70-100
70-100
70-100
110-200
110-200
225-400
225-400
450-600
450-600
Data Sheet: 5006
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
397
Telcom Protection Products
Indicating Fuses and Holders
70 Series Fuses
15087 Fuse Holder
Specifications
Description: Indicating type fuse.
Ratings:
Volts: — 125Vac/300Vdc
Amps: — 1⁄10-10A
IR: — 1kA @ 300Vdc
Agency Information: CE, UL Recognized,
Guide JDYX2, File E19180 Bellcore.
Specifications
Description: Fuse holder
for 70 Series fuses.
Ratings:
Volts: — 300Vdc
Amps: — 12A
Agency Information: CE, UL
Recognized, Guide IZLT2, File
E14853.
Flammability Rating: UL 94V0.
Catalog Numbers
Catalog
Amp
Numbers
Rating
1
70P-1⁄10A*
⁄10
15
70R-15⁄100A*
⁄100
18
70E-18⁄100A*
⁄100
2
70X-2⁄10A
⁄10
1
70F-1⁄4A*
⁄4
1
1
70K- ⁄4A*
⁄4
1
1
70G- ⁄2A*
⁄2
3
3
70H- ⁄4A*
⁄4
70I-1A
1
1
1
70A-1 ⁄3A*
1 ⁄3
70B-2A*
2
70C-3A*
3
70J-31⁄2A
31⁄2
70D-5A*
5
70L-6A
6
70M-8A
8
70N-10A
10
GKB-10A
10
72A Plastic CaseDummy
72B Blister PackDummy
Color
Code
Gray/Wh
Red/Wh
Yellow
Black
Violet
Violet/Wh
Red
Brown
Pink
White
Orange
Blue
Black/Wh
Grn/Blk
Grn/Wh
Brown/Wh
Violet/Yel
Violet/Yel
—
—
Lucent
Comcode
Ref. No.
100203413
101384550
100203363
—
100203371
100203405
100203389
100203397
—
100203322
100203330
100203348
—
100203355
—
—
—
—
100203421
103757977
Code/
List No.
KS23751-L10
KS23751-L11
KS23751-L5
—
KS23751-L6
KS23751-L9
KS23751-L7
KS23751-L8
—
KS23751-L1
KS23751-L2
KS23751-L3
—
KS23751-L4
—
—
—
—
—
—
*Product designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1,
December 1988.
Data Sheet: 5007
398
Features and Benefits
• Panel mount fuse holder for 70 Type fuses supplied with
two screws
• Remote alarm capability
Typical Applications
• Telecommunications DC power circuit protection
Catalog Number — 15087
Accessories
Description: Optional color code eyelets used with fuse
holder to indicate fuse amp rating.
Eyelet Catalog Numbers
Catalog
Numbers
1A1706-01
1A1706-02
1A1706-03
1A1706-04
1A1706-05
1A1706-06
1A1706-07
1A1706-08
1A1706-09
1A1706-10
1A1706-11
1A1706-12
1A1706-13
1A1706-14
1A1706-15
1A1706-16
1A1706-17
Amp
Indication
18
⁄100
2
⁄10
1
⁄4
1
⁄4
1
⁄2
3
⁄4
1
1
1 ⁄3
2
3
5
6
8
10
1
⁄10
31⁄2
15
⁄100
Color
Code
Yellow
Black
Violet
Violet/White
Red
Brown
Pink
White
Orange
Blue
Green/Black
Green/White
Brown/White
Violet/Yellow
Gray/White
Black/White
Red/White
Data Sheet: 5007
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
Telcom Protection Products
Indicating Fuses and Holders
HLS, HLT, PCT
GMT
Specifications
Description: Fuse
holders for GMT Type
indicating fuses.
Poles: 01 to 25.
Ratings:
Volts: — 60Vdc/125Vac
Agency Information:
CE, UL Recognized,
Guide IZLT2, File
E14853, 15A (60Vdc).
Flammability Rating:
UL 94V0.
Specifications
Description: Fast-acting fuses for use in HLT, HLS, and
PCT fuse holders.
Ratings:
Volts: — 60Vdc/125Vac
Amps: — 18⁄100-15A
IR: — 450A@60Vdc
— 300A@125Vac
Agency Information: CE, UL Recognized, Guide JFHR2,
File E56412.
Flammability Rating: UL 94V0.
Features and Benefits
• Local and remote indication capability
• Color coded for easy amp rating identification
Features and Benefits
• Multiple configurations provide
application flexibility
• Compact size saves space
Typical Applications
• Telecommunications DC power circuit protection
GMT - A (Alarm)
GMT - Dummy
Typical Applications
• Telecommunications DC power circuit protection
Catalog Numbers
Catalog Numbers
PCT
HLS
HLT
Catalog Numbers
Catalog
Numbers
GMT-18⁄100A
GMT-1⁄4A
GMT-3⁄8A
GMT-1⁄2A
GMT-65⁄100A
GMT-3⁄4A
GMT-1A
GMT-1-1⁄3A
GMT-1-1⁄2A
GMT-2A
GMT-3A
Poles
1
See Build-A-Code
See Build-A-Code
Multiple Fuseholders with bus bars
Ordering Information— Catalog No.
Color
Code
Yellow
Violet
White/Gray
Red
Black
Brown
Gray
White
White/Yellow
Orange
Blue
Catalog
Numbers
GMT-3-1⁄2A
GMT-4A
GMT-5A
GMT-7-1⁄2A
GMT-10A
GMT-12A
GMT-15A
GMT-Dummy
GMT-X
GMT-Y
Color
Code
White/Blue
White/Brown
Green
Black/White
Red/White
Yellow/Green
Red/Blue
Gray Body
Clear Cover
Clear Cover
Some GMT sizes may be sold in bulk pack only.
Body Style HLT
HLS (No flanges)
Termination Location
No. of Poles 01 thru 25
(Min. of 2 poles required for bus bars)
L
R
(Left only)
(Right only)
Accessories
• Spare fuse holder: Catalog Number TPSFH-T
B
Type of bus bars used***
B1*, B2, B3,
B4, B5, SL** (Short Leads .135")
ML** (Medium Leads .250")
(Both ends)
Bus Bar Position
B1
(Angle Bar Only)*
B4
(Angle & “L” Bars)
B2
(“L” Bar Only)
B3
(“U” Bar Only)
P2
(Outside—
Both Sides)
P3
(Outside—
Right Only)
P4
(Outside—
Left Only)
Catalog Numbers
B5
(“L” & “U” Bars)
*Angle Bar mounts on common or center terminals only.
**SL Version is not available with bus bars.
†Minimum of 4 Poles Required.
***.38 max. leads if not specified.
Data Sheet: 5010
P1†
(Inside—
Both Sides)
Specifications
Description: Fast-acting fuse designed specifically for use
in the Telpower® series 15800 fused disconnect switch
(page 392).
Agency Information: The GMT-A has the same ratings
and agency approvals as the standard GMT fuses as shown
above.
Catalog Number
GMT-A
Color Code
Yellow
Data Sheet: 5008
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
399
Telcom
Protection
Products
GMT-A
** Not available with bus bars
Telcom Protection Products
Telpower Specialty Fuses
7 Type
11 Type
Specifications
Description: Fiber tube, threaded ends. Typically used on
wall type main distribution frames and central battery
substations.
Dimensions: See Catalog Numbers table and Dimensions
illustration.
Ratings:
Amps: — 7A
Agency Information: CE
Specifications
Description: Fiber tube, threaded ends, identical to 7 Type
except for vent slots in fiber tube.
Dimensions: See Dimensions illustration.
Ratings:
Amps: — 7A
Agency Information: CE
Catalog Numbers
Catalog
Numbers
7A-7
7T-7
Amp
Rating
7
7
Lucent Comcode
Ref. No.
100863737
100202753
Dimension
A Length (in)
4.562
4.828
Catalog Number
Catalog
Number
11C-7
Amp
Rating
7
Lucent Comcode
Ref. No.
100863745
Dimensions - in
4.625"
4.062"
Dimensions - in
A
4.093"
24 and WER Type
74 Type
Specifications
Description: Flat, non-indicating visible
link element mounted on 1 inch centers
using either No. 6 or No. 10 screws.
Dimensions: See Dimensions illustration.
Ratings:
Volts: — 32Vdc ( ⁄ , 1, 3 1⁄2, 8, 10A)
— 60Vdc (1⁄2, 3⁄4, 1 1⁄2, 2, 3, 4, 5A)
Amps: — 1⁄4-10A
Agency Information: CE, UL Recognized File E56412.
Specifications
Description: Fast-acting 0.281” x 1.25” cylindrical fuse
designed to comply with Lucent specification KS23753. High
current companion to 70 Type Fuse.
Dimensions: See Dimensions illustration.
Ratings:
Volts: — 60Vdc
Amps: — 1 1⁄4-20A
Agency Information: CE, UL Recognized File E19180.
1
4
Catalog Numbers
Catalog
Amp
Numbers
Rating
1
WER-1⁄4
⁄4
1
24E-1⁄2*
⁄2
3
24D-3⁄4*
⁄4
WER-1
1
24G-1-1⁄3*
1 1⁄3
24C-2*
2
24B-3*
3
WER-3-1⁄2
3 1⁄2
24B-4*
4
24F-5*
5
WER-8
8
WER-10
10
64A-Dummy —
DC
Volts
32
60
60
32
60
60
60
32
60
60
32
32
—
Color
Code
—
Red
Black
—
White
Orange
Blue
—
Yellow
Green
—
—
—
Lucent Comcode
Ref. No.
—
100202894
100202886
—
100202910
100202878
100202852
—
100202860
100202902
—
—
100203280
A Length
Inches
—
0.20
0.15
—
0.20
0.20
0.15
—
0.15
0.15
—
—
—
Catalog Numbers
Catalog
Amp
Lucent Comcode
Numbers
Rating
Ref. No.
List No.
102630290
KS23753-L1
74A-1-1⁄4
1 1⁄4
Code/
74G-2
2
103064952
KS23753-L7
74B-3
3
102630308
KS23753-L2
74H-4
4
103264669
KS23753-L8
74C-5
5
102630316
KS23753-L3
74J-7-1⁄2
7 1⁄2
103228425
KS23753-L9
74D-10
10
102630324
KS23753-L4
74E-15
15
102630332
KS23753-L5
74F-20
20
102630340
KS23753-L6
Dimensions - in (mm)
*Designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, Dec. 1988.
1.25"
Dimensions - in
(31.75mm)
A 0.375"
400
0.281"
(7.14mm)
1.406"
0.938"
A
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
Telcom Protection Products
Telpower Specialty Fuses
75 Type
76 Type
Specifications
Description: Cylindrical with leads,
designed to provide protection against
currents resulting from the application of foreign voltages.
Application for data sets and telephones.
Dimensions: See Dimensions illustration.
Ratings:
Volts: — 135Vac/220Vdc ([email protected])
Amps: — 0.007-0.230A
Agency Information: CE
Specifications
Description: Cylindrical with leads,
designed to provide protection against
currents resulting from the application
of foreign voltages. Application for data
sets and telephones.
Dimensions: See Dimensions illustration.
Ratings:
Volts: — 135Vac/440Vdc
Amps: — 0.012-0.412A
Agency Information: CE
Catalog Numbers
Catalog
Numbers
Amp
Rating
Lucent Comcode
Ref. No.
Code/
List No.
75C
0.007
103260816
Catalog Numbers
KS23825-L3
Catalog
Numbers
Amp
Rating
Lucent Comcode Code/
Ref. No.
List No.
75F
0.063
104172861
KS23825-L6
76D
0.012
103798245
KS23825-L10
75B
0.115
102732112
KS23825-L2
76B
0.191
102965688
KS23825-L8
75D
0.129
104013180
KS23825-L4
76A
0.231
102810181
KS23825-L7
75A
0.200
102660008
KS23825-L1
76C
0.412
103656625
KS23825-L9
75E
0.230
104015292
KS23825-L5
0.620"
(8.26mm)
(15.75mm)
0.830"
(21.08mm)
— —A
— —A
Dimensions - in (mm)
0.325"
0.445"
(11.30mm)
Dimensions - in (mm)
0.320"
(8.13mm)
0.190"
1.125"
(4.83mm)
(28.58mm)
0.800"
(20.32mm)
81 Type
Specifications
Description: A fuse designed for high reliability applications
where high ambient temperatures, low circuit voltages, low
power dissipation and low contact resistance are prime
considerations. The 80 Type is a visual indicating fuse with
remote electrical alarm capability. UL Recognized, Guide
JDYX2, File E19180.
Dimensions: See Dimensions illustrations.
Ratings:
Volts: — 160Vdc
Amps: — 1⁄2-5A
Agency Information: CE, UL Recognized File E19180.
Specifications
Description: Cylindrical, fast-acting, non-indicating high
current companion to the 80 Type.
Dimensions: See Dimensions illustration.
Ratings:
Volts: — 65Vdc
Amps: — 7 1⁄2-12A
Agency Information: CE, UL Recognized, Guide JDYX2,
File E19180.
81B-7-1⁄2
Catalog Numbers
Catalog Amp
Numbers Rating
Color
Code
Lucent Comcode Code/
Ref. No.
List No.
80G-1⁄2
1
Red
103839916
80M-1-1⁄3
11⁄3
White
408078657
KS23824-L8
80B-2
2
Orange
103752150
KS23824-L2
80C-3
3
Blue
103752168
KS23824-L3
80D-5
5
Green
103800637
KS23824-L4
⁄2
Catalog Numbers
Catalog Amp
Color
Numbers Rating Code
7 1⁄2
Lucent Comcode
Ref. No.
Code/
List No.
Gray
103828141
KS23824-L12
81A-10
10
Yellow
103752176
KS23824-L11
81C-12
12
Lt Blue
104391842
KS23824-L13
KS23824-L6
Dimensions - in (mm)
2.685"
(68.20mm)
0.280"
(7.11mm)
Dimensions - in (mm)
2.685"
(68.20mm)
0.280"
(7.11mm)
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
401
Telcom
Protection
Products
80 Type
Telcom Protection Products
Filtered Terminal Blocks
Insertion Loss for 2,500 pF Pi Schematic
F38 Series
Typical Insertion Loss* (dB) in 50 Ω Circuit
Specifications
Description: Terminal blocks for
filtering line power in
telecommunications applications.
Ratings:
Volts: — 240Vac/300Vdc
Amps: — 30A
Center Spacing: 0.437" or 7⁄16" (11.1mm).
Wire Range: # 10-22 AWG Cu.
Screw Size: # 8-32 (# 6-32 available, consult factory).
Torque Rating: 15 lb-in.
Operating Temperature: –55°C to +105°C.
Capacitance: 1,000 pF to 5,000 pF in either C or Pi
Schematic.
Dielectric Withstanding: 1000Vac/1700Vdc.
DC Resistance: 0.01 Ω max.
Agency Information: UL/CSA, CE Certified.
Flammability Rating: UL 94V0.
30MHz: 42 dB
50MHz: 45 dB
100MHz: 50 dB
300MHz: 68 dB
1000MHz: 70 dB
* For other capacitance insertion loss, consult factory.
Features and Benefits
• Rugged integrated construction of filtering elements around
a solid brass pin provides excellent EMI/RFI filtering with
high insertion loss for EMI/RFI filtering of AC and DC power
and control lines
• 2 to 8 terminals standard (up to 16-poles available) with
options for straight lead, male or female quick-connect
Typical Applications
• Cost-effective EMI solution for industrial interconnection
filtering
Dimensions - in
Poles*
2
3
4
5
6
7
8
Front Mount
A
1.67
2.10
2.54
2.98
3.41
3.85
4.29
Rear Mount
A
1.88
2.32
2.76
3.19
3.63
4.07
4.51
B
1.31
1.75
2.19
2.63
3.06
3.50
3.94
C
0.93
1.37
1.81
2.25
2.68
3.12
3.56
D
0.44
0.88
1.31
1.75
2.19
2.62
3.06
1” = 25.4mm.
* Note: Available up to 16-poles. Consult factory.
Front Panel Mount
(Code 0)
Rear Panel Mount
(Code 1)
Catalog Number Build-A-Code
Series Terminal Style
Mounting
# of Poles
F38
_
_
0 = Straight lead
1 = 0.187" Quick
connect (male)
2 = 0.187" Quick
connect (female)
3 = 0.250" Quick
connect (male)
4 = 0.250" Quick
connect (female)
0 = Front panel mount
02 to 08*
with mount ends
1 = Rear panel mount
with #4-40 threaded inserts
__
Screw Options
Filter Options
Capacitance
__
_
_
Blank = #8-32, steel, zinc-plated
philslot BHMS (standard)
04 = #8-32, Brass, nickel-plated
philslot BHMS
92 = #8-32, Steel, zinc-plated
slotted BHMS
94 = #8-32, Brass, nickel-plated
slotted BHMS
C = C Filter
P = Pi Filter
1.0 = 1,000 pF +100%-0%
2.5 = 2,500 pF +100%-0%
5.0 = 5,000 pF +100%-0%
* Note: Standard is 02-08 poles. Available up to 16-poles. Consult Cooper Bussmann for availability.
Special electrical/mechanical configurations are available upon request.
402
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
.
Telcom Protection Products
Power Feed Through Terminal Blocks
Dimensions - in (mm)
Series C7021
Catalog
Numbers
C7021-01-X
C7021-02-X
C7021-03-X
C7021-04-X
C7021-05-X
C7021-06-X
C7021-01N-X
C7021-02N-X
C7021-03N-X
C7021-04N-X
C7021-05N-X
C7021-06N-X
Specifications
Description: Power
feed through terminal
block with two rows
1
⁄4-20 studs capable of
accommodating the
industry standard
two-hole compression
lugs on both studs in
parallel.
Ratings:
Volts: — 300V
Amps: — 115/175A* per pole
Center Spacing: 0.690" (17.5mm).
Wire Range: AWG #2/0-8.
Poles: 2- to 6-poles.
Bolt Hole Spacing: 0.625" or 5⁄8” (15.88mm).
Stud: Standard 1⁄4-20 stud (tin-plated brass) or optional M6
stud.
Mounting: #6 thread cutting screws (not included) or
optional mounting ears.
Torque Rating: 36 lb-in.
Operating Temperature: 130°C.
Agency Information: UL/CSA; CE Certified.
A
B
17.5
34.9
52.3
69.8
87.2
(0.69)
(1.37)
(2.06)
(2.75)
(3.44)
17.5
34.9
52.3
69.8
87.2
(0.69)
(0.69)
(2.06)
(2.75)
(3.44)
C
-
D
54.4
70.9
89.3
106.8
124.2
36.1 (1.42)
53.5 (2.11)
71.0 (2.80)
88.4 (3.48)
105.9 (4.17)
(2.14)
(2.83)
(3.52)
(4.20)
(4.89)
E
67.3 (2.65)
84.8 (3.34)
102.2 (4.02)
119.7 (4.71)
134.1 (5.40)
-
-
31.8
49.2
66.7
84.2
101.7
(1.25)
(1.94)
(2.63)
(3.31)
(4.00)
31.8
49.2
66.7
84.2
101.7
(1.25)
(1.94)
(2.63)
(3.31)
(4.00)
D
C
9.6
28.0 (0.38)
(1.10)
15.8
(0.62)
5.4
(0.21)
15.8
(0.62)
55.7
(2.19)
12.5
(0.49)
Ø 9.0 TYP
(0.35)
7.9
(0.31)
1/4-20 UNC-2A
Thread TYP
A
ø12.2 TYP
(0.48)
B
17.5 TYP
(0.69)
*175 achieved using both studs in parallel, 115A using a single stud per line.
15.0 TYP
(0.59)
Typical Applications
• Applications requiring up to 175A utilizing a 2-hole
compression lug on 5⁄8" centers
• Input/output block for telecommunications power panels
• Use to eliminate busbars
24.0
(0.94)
12.7
(0.50)
33.0
(1.30)
14.5 TYP
(0.57)
Blind Hole for #6
Thread Cutting
Screw
14.5 TYP
(0.57)
Panel Cutouts
E
14.2
( ø.56)
A
1.6
(R.06)
Telcom
Protection
Products
30.0
(1.18)
Catalog Number Build-A-Code
Series
Poles
Mount Ends
Studs
C7021 –
Hardware
–
01
02
03
04
05
06
=
=
=
=
=
=
1-Pole
2-Pole
3-Pole
4-Pole
5-Pole
6-Pole
(2 studs)
(4 studs)
(6 studs)
(8 studs)
(10 studs)
(12 studs)
Blank = Mount ends
N = No mount ends
Blank = Standard
M6 = M6 Studs
Blank = No hardware
0 = Bulk pack, one set
1 = Bulk pack, two sets
2 = Assembled, bottom
3 = Assembled, top
4 = Assembled, both sets
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
403
Telcom Protection Products
Power Feed Through Terminal Blocks
Series C7024
Specifications
Description: A
power feed through
terminal block with
two rows of 1⁄4-28
studs capable of
accommodating the industry standard two-hole compression
lugs on 3⁄4" centers.
Dimensions: See Dimensions illustration.
Ratings:
Volts: — 600V
Amps: — 115A per pole
Center Spacing: 0.75" (19.1mm).
Wire Range: #2-8 AWG.
Poles: 1 to 12.
Bolt Hole Spacing: 0.75" (19.1mm).
Stud: Standard 1⁄4-28 stud (tin-plated bronze).
Torque Rating: 36 lb-in.
Operating Temperature: 130°C.
Agency Information: UL/C-UL, CSA; CE Certified.
Flammability Rating: UL 94V0.
Typical Applications
• Applications requiring up to 115A utilizing a 2-hole
compression lug on 3⁄4" centers
• Ideal as an input/output block for telecommunications power
panels
• Use to eliminate busbars
Dimensions - mm (in)
Ø17.780 TYP
[0.700]
MIN. AT STUD PAD
13.2TYP
[0.52]
0.5 TYP
[0.02 ]
Catalog Numbers
Catalog
Number
C7024-01
C7024-02
C7024-03
C7024-04
C7024-05
C7024-06
C7024-07
C7024-08
C7024-09
C7024-10
C7024-11
C7024-12
Poles
01
02
03
04
05
06
07
08
09
10
11
12
“A” Dimension- mm (in)
±0.4 (±0.02)
“B” Dimension- mm (in)
21.6 (0.85)
40.6 (1.60)
19.05 ±0.08 (0.750 ±0.003)
59.7 (2.35)
38.10 (1.500)
78.7 (3.10)
57.15 ±0.26 (2.250 ±0.010)
97.8 (3.85)
76.2 (3.00)
116.8 (4.60)
95.25 ±0.26 (3.750 ±0.010)
135.9 (5.35)
114.30 ±0.38 (5.250 ±0/015)
154.9 (6.10)
133.35 ±0.38 (5.25 ±0.015)
174.0 (6.85)
152.40 ±0.38 (6.00 ±0.015)
193.0 (7.60)
171.45 ±0.38 (6.750 ±0.015)
212.1 (8.35)
190.50 ±0.38 (7.500 ±0.015)
231.1 (9.10)
209.55 ±0.38 (8.250 ±0.015)
B
A
16.53TYP
[0.651]
28.0
[1.10]
17.8TYP
[0.70]
2.70TYP
[ 0.106 ]
3.16TYP
[0.124]
Ø14.4
[0.57]
19.06 ±0.08
[ 0.750 0.003]
40.6
[1.60]
Catalog Number Build-A-Code
Series
Poles
C7024 –
01-12
404