Medium Voltage Fuses

Medium Voltage Fuses
Section Contents
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
E-Rated Fues
For transformers & feeders . . . . . . . . . . . . . . . . . . . . . . .75
CL-14 & bolt-in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
CL-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
For potential & small power transformers . . . . . . . . . . 78-79
British IEC fuses for motor circuit protection . . . 83
DIN IEC fuses for transformer protection . . . . . . 84
Potential transformer fuses . . . . . . . . . . . . . . . . . 85
British IEC fuses for oil-filled switchgear . . . . . . 86
Fast-acting fuses . . . . . . . . . . . . . . . . . . . . . . . . . 87
EEI-NEMA Type K & T and Type H & N fuses . . . 88
BBU Boric acid fuses . . . . . . . . . . . . . . . . . . . 89-90
Fuseclips for medium and high voltage fuses . . . 91
71
Medium
Voltage
Fuses
R-Rated fuses for motor circuit protection . . . 80-82
Medium Voltage Fuses
Medium Voltage Fuses
Worldwide Circuit Protection Solutions
Cooper Bussmann is a world-leading supplier of medium
voltage fuses. Each product is backed by an efficient
worldwide distribution network with unrivaled service and
technical support. Cooper Bussmann circuit protection
solutions comply with major international standards: ANSI,
BS, DIN, IEC and UL.
Fuse Types
Medium voltage fuses generally fit into two categories –
expulsion fuses and current limiting fuses. The definitions per
ANSI C37.40 are:
Expulsion Fuse: “A vented fuse in which the expulsion effect
of the gases produced by internal arcing, either alone or
aided by other mechanisms results in current interruption.”
Expulsion fuses will limit the duration of an overcurrent
event, but they will not limit the magnitude of fault current.
Cooper Bussmann offers two types of expulsion fuses:
replacement fuse links for fused cutouts and boric acid
fuses.
Current Limiting Fuse: “A fuse unit that, when in its currentresponsive element is melted by a current within the fuse’s
specified current-limiting range, abruptly introduces a high
resistance to reduce current magnitude and duration,
resulting in subsequent current interruption.” A current
limiting fuse will reduce the magnitude a fault current as well
as limit the duration of the overcurrent event when operating
in its current limiting range. Cooper Bussmann offers a broad
range of current limiting fuses for protection of feeders,
transformers and motor circuits designed to ANSI, BS, DIN
and IEC standards.
Medium Voltage Current Limiting Fuses
Current limiting fuses are classified into three categories:
1. Full Range – defined by ANSI C37.40 as “a fuse capable
of interrupting all currents from the maximum rated
interrupting current down to the minimum continuous current
that causes the melting of the fusible element(s), when the
fuse is applied at the maximum ambient temperature
specified by the manufacturer.” It is able to interrupt any
current that will melt its element.
72
2. General Purpose – defined by ANSI C37.40 as “a fuse
capable of interrupting all currents from the maximum rated
interrupting current down to the current that causes melting
of the fusible element(s) in one hour.” Not all currents fall
within this range. It is possible for the fuse to be exposed to
an overcurrent lower than the value given by the one hour
criteria. In that case, a different overcurrent protection device
would be required to interrupt the overcurrent.
3. Back-up – defined by ANSI C37.40 as “a fuse capable of
interrupting all currents from the maximum interrupting rating
current down to the minimum interrupting current.”
The minimum interrupting current is the lowest current that
the fuse will be able to clear properly. This creates a need to
place a low current interrupting device, such as motor
overloads, in series with the back-up rated fuse.
E- and R-Rated Fuses
In North America, current limiting fuses typically fall into the
category of E-Rated fuses and R-Rated fuses. Cooper
Bussmann also offers a wide range of current limiting fuses
designed to BS, DIN and IEC standards.
E-Rated fuses are used to protect feeder circuits, power
transformers and potential transformers. E-Rated fuses have
defined current response times specified by ANSI C37.46.
E-Rated fuses 100A and below must melt in 300sec at an
rms current within the range of 200% to 240% of the
continuous current rating. E-Rated fuses above 100A must
melt in 600sec at an rms current within the range of 240% to
264% of the continuous current rating of the fuse. Cooper
Bussmann offers a wide variety of full range and general
purpose E-Rated fuses from 2.4kV up to 38kV.
R-Rated fuses are back-up fuses that provide short-circuit
protection for motor circuits. They are applied with MV motor
starters which provide the overload protection for the circuit.
R-Rated fuses also have defined current response times
specified by ANSI C37.46. R-Rated fuses will melt in a range
of 15 – 35sec at a current equal to 100 times the “R” rating.
Cooper Bussmann offers 2.4kV, 5.08kV, 7.2kV and 8.3kV
R-Rated fuses for motor circuit protection.
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
Medium Voltage Fuses
E-rated Fuses for Transformers and Feeders
5.5kV Catalog Numbers
MV055 and
MV155
Catalog
Numbers
MV055 Features and Benefits
• Standard clip center distance of 12 inches with 2 and 3 inch
barrel diameters for retrofitting in existing hardware
• Open fuse indicator for ease in troubleshooting
• Full range rating with 50,000 Interrupting Rating
• Double pulsed at 90% of minimum I2t to establish
manufacturing reliability
•
•
•
•
MV055 Typical Applications
5.0kV Transformer Primary Protection
5.0kV Feeder Circuit Protection
5.0kV Voltage Switches
5.0kV Metal-enclosed Switchgear
MV155 Features and Benefits
• Standard clip center distance of 15 and 18 inches with 2 and
3 inch barrel diameters for retrofitting in existing hardware
• Open fuse indicator for ease in troubleshooting
• Full range rating with 50,000 Interrupting Rating
• Double pulsed at 90% of minimum I2t to establish
manufacturing reliability
•
•
•
•
MV155 Typical Applications
15.0kV Transformer Primary Protection
15.0kV Feeder Circuit Protection
15.0kV Voltage Switches
15.0kV Metal-enclosed Switchgear
Min
Melt
I2t
MV055F1CAX5E
5
180
MV055F1CAX7E
7
850
MV055F1CAX10E
10
850
MV055F1CAX15E
15
2,070
MV055F1CAX20E
20
2,370
MV055F1CAX25E
25
4,650
MV055F1CAX30E
30
9,490
MV055F1CAX40E
40
9,490
MV055F1CAX50E
50
13,600
MV055F1CAX65E
65
30,700
MV055F1DAX10E
10
850
MV055F1DAX15E
15
2,070
MV055F1DAX20E
20
2,370
MV055F1DAX25E
25
4,650
MV055F1DAX30E
30
9,490
MV055F1DAX40E
40
9,490
MV055F1DAX50E
50
13,600
MV055F1DAX65E
65
30,700
MV055F1DAX80E
80
54,600
MV055F1DAX100E
100
116,200
MV055F1DAX125E
125
167,400
MV055F1DAX150E
150
218,700
MV055F1DAX175E
175
227,900
MV055F1DAX200E
200
297,600
MV055F2DAX250E
250
669,600
MV055F2DAX300E
300
874,800
MV055F2DAX350E
350
911,600
MV055F2DAX400E
400
1,190,400
MV055F2DAX450E
450
1,555,000
1” = 25.4mm
Recommended Fuse Clips - see page 91
Max
Clear
I2t
2,400
8,000
8,000
11,000
23,000
31,000
45,000
45,000
90,000
181,000
8,000
12,000
23,000
31,000
45,000
45,000
90,000
181,000
270,000
580,000
600,000
786,000
1,100,000
1,520,000
2,400,000
3,149,000
4,376,000
6,071,000
9,796,000
Dimensions (in)*
Clip
Length Dia. Center Barrels
15.75
2
12
1
12
1
2
15.75
3
Medium
Voltage
Fuses
Specifications
Description: E-rated
medium, voltage currentlimiting fuses: for
transformer and feeder protection.
Dimensions: See Catalog Numbers table.
Construction: Silver ribbon element surrounded by silica
filler housed in a fiberglass tube and plated endcaps. An
epoxy paint protects the fuse tube from the surrounding
environment.
Ratings:
Volts: — 5.5kV (5-450A)
— 15.5kV (5-200A)
Amps: — 5-450A (5.5kV)
— 5-200A (15.5kV)
IR: — 50kA Sym. Max
Agency Information: Meets E requirements per ANSI
C37.46, Meets full range requirements per ANSI C37.40.
Amp
Rating
1
12
15.75
3
15.75
3
12
1
15.75
3
12
2
2
Data Sheet: 6700
15.5kV Catalog Numbers
Catalog
Numbers
MV155F1CBX5E
MV155F1CBX7E
MV155F1CBX10E
MV155F1CBX15E
MV155F1CBX20E
MV155F1CBX25E
MV155F1CBX30E
MV155F1DBX10E
MV155F1DBX15E
MV155F1DBX20E
MV155F1DBX25E
MV155F1DBX30E
MV155F1DBX40E
MV155F1DBX50E
MV155F1DBX65E
MV155F1DBX80E
MV155F1DBX100E
MV155F2DBX125E
MV155F2DBX150E
MV155F2DBX175E
MV155F2DBX200E
MV155F1DCX65E
MV155F1DCX80E
MV155F1DCX100E
MV155F2DCX125E
MV155F2DCX150E
MV155F2DCX175E
MV155F2DCX200E
*1” = 25.4mm.
Amp
Rating
5
7
10
15
20
25
30
10
15
20
25
30
40
50
65
80
100
125
150
175
200
65
80
100
125
150
175
200
Min
Melt
I2t
Max
Clear
I2t
180
850
850
2,070
2,370
4,650
9,490
850
2,070
2,370
4,650
9,490
9,490
13,600
30,700
54,600
116,200
123,000
218,700
314,700
465,100
30,700
54,600
116,200
123,000
218,700
314,700
465,100
2,900
8,000
8,000
12,000
23,000
31,000
45,000
8,000
12,000
23,000
31,000
45,000
45,000
90,000
181,000
270,000
600,000
677,000
1,287,000
1,689,000
2,405,000
181,000
270,000
600,000
677,000
1,287,000
1,689,000
2,405,000
Dimensions*
Clip
Center Barrels
Length Dia.
18.75
15
1
15
1
1
2
18.75
3
15
18.75
18.75
3
3
15
2
2
21.75
3
18
1
1
21.75
21.75
3
18
18
2
2
Recommended Fuse Clips - see page 91
Data Sheet: 6701 (MV155)
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
73
Medium Voltage Fuses
E-rated Fuses for Transformer & Feeders
JCX, JCY, JCU, JCZ
and JDZ
Specifications
Description: Indoor/enclosure
E-rated medium voltage, currentlimiting fuses for feeders and
power transformers with blown fuse
indication.
Dimensions: See Catalog
Numbers table.
Construction: plated ferrules.
Ratings:
Volts: — 2750-8300V (See Catalog Numbers table for
details)
Amps: — 1⁄2-750A
IR: — 40-63kA Sym
— 60-100kA ASYM
— See Catalog Numbers table for details
Features and Benefits
• Physically dimensioned for retrofitting in existing hardware
• Open fuse indicator for ease in troubleshooting
• Full range ANSI classification
•
•
•
•
Typical
Medium
Medium
Medium
Medium
Applications
Voltage Transformer Primary Protection
Voltage Feeder Circuit Protection
Voltage Switches
Voltage Metal-enclosed Switchgear
Catalog Numbers
Catalog
Amp
Maximum
Numbers
Rating
Design Voltage
2400V; E-Rated; Indoor/Enclosure
JCX-1⁄2E
0.5
2750
JCX-1E
1
2750
JCX-2E
2
2750
JCX-3E
3
2750
JCX-5E
5
2750
JCX-7E
7
2750
JCX-10E
10
2750
JCX-15E
15
2750
JCX-20E
20
2750
JCX-25E
25
2750
JCX-30E
30
2750
JCX-40E
40
2750
JCX-50E
50
2750
JCX-65E
65
2750
JCX-80E
80
2750
JCX-100E
100
2750
JCX-125E
125
2750
JCX-150E
150
2750
JCX-200E
200
2750
JCX-225E
225
2750
JCX-250E/280X
250/280
2750
JCX-300E/325X
300/325
2750
JCX-350X
350
2750
JCX-400X
400
2750
JCX-450X
450
2750
5500V; E-Rated; Indoor/Enclosure
JCY-1⁄2E
0.5
5500
JCY-1E
1
5500
JCY-2E
2
5500
JCY-3E
3
5500
JCY-5E
5
5500
JCY-7E
7
5500
JCY-10E
10
5500
JCY-15E
15
5500
JCY-20E
20
5500
JCY-25E
25
5500
Construction
Maximum Interrupting Capacity
Amps (Asym.)
Amps (Sym.)
Dimensions - in (mm)
Length
Diameter
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Double
Double
Double
Double
Double
60,000
60,000
60,000
60,000
60,000
60,000
60,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
40,000
40,000
40,000
40,000
40,000
40,000
40,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
40,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
9.19 (233.38)
9.19 (233.38)
9.19 (233.38)
9.19 (233.38)
9.19 (233.38)
9.19 (233.38)
9.19 (233.38)
9.5 (241.3)
9.5 (241.3)
9.5 (241.3)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
10.81 (276.35)
2 (50.8)
2 (50.8)
2 (50.8)
2 (50.8)
2 (50.8)
2 (50.8)
2 (50.8)
2.1 (53.34)
2.1 (53.34)
2.1 (53.34)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
60,000
60,000
60,000
60,000
60,000
60,000
60,000
60,000
60,000
60,000
40,000
40,000
40,000
40,000
40,000
40,000
40,000
40,000
40,000
40,000
11.19
11.19
11.19
11.19
11.19
11.19
11.19
11.19
11.19
11.19
2
2
2
2
2
2
2
2
2
2
(284.18)
(284.18)
(284.18)
(284.18)
(284.18)
(284.18)
(284.18)
(284.18)
(284.18)
(284.18)
Contact Cooper Bussmann for the latest product information on E-Rated fuses for transformer and feeder protection.
Recommended fuseclips: see page 91 - 1A0065, 9078A67G04, A3354730
74
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
(50.8)
(50.8)
(50.8)
(50.8)
(50.8)
(50.8)
(50.8)
(50.8)
(50.8)
(50.8)
Medium Voltage Fuses
E-rated Fuses for Transformer & Feeders
Catalog Numbers: E-Rated; Indoor/Enclosure
Maximum
Design Voltage
Construction
Maximum Interrupting Capacity
Amps. (Asym.)
Amps. (Sym.)
Dimensions - in (mm)
Length
Diameter
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
5500
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Double
Double
Double
Double
*
*
80,000
80,000
80,000
80,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
100,000
80,000
80,000
50,000
50,000
50,000
50,000
63,000
63,000
63,000
63,000
63,000
63,000
63,000
63,000
63,000
63,000
63,000
63,000
63,000
63,000
63,000
50,000
50,000
17.81
12.88
12.88
12.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
28.81
28.81
(452.4)
(327.0)
(327.0)
(327.0)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(731.77)
(731.77)
3 (76.2)
2.1 (53.34)
2.1 (53.34)
2.1 (53.34)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
3 (76.20)
4 (101.60)
4 (101.60)
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
8300
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Double
Single
Single
Single
Single
Single
Single
Double
Double
Double
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
15.51
15.51
15.51
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
15.88
15.88
15.88
15.88
15.88
15.88
15.88
15.88
15.88
(393.95)
(393.95)
(393.95)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(454.15)
(403.2)
(403.2)
(403.2)
(403.2)
(403.2)
(403.2)
(403.2)
(403.2)
(403.2)
2.1 (53.34)
2.1 (53.34)
2.1 (53.34)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
3 (76.2)
Medium
Voltage
Fuses
Catalog
Amp
Numbers
Rating
5500V; E-Rated; Indoor/Enclosure
JCU-10E
10
JCU-15E
15
JCU-20E
20
JCU-25E
25
JCU-30E
30
JCU-40E
40
JCU-50E
50
JCU-65E
60
JCU-80E
80
JCU-100E
100
JCU-125E
125
JCU-150E
150
JCU-175E
175
JCU-200E
200
JCU-250E
250
JCU-300E
300
JCU-350E
350
JCU-400E
400
JCU-450E
450
JCU-600E
600
JCU-750E
750
8300V; E-Rated; Indoor/Enclosure
JCZ-15E
15
JCZ-20E
20
JCZ-25E
25
JCZ-30E
30
JCZ-40E
40
JCZ-50E
50
JCZ-65E
65
JCZ-80E
80
JCZ-100E
100
JCZ-125E
125
JCZ-150E
150
JCZ-200E
200
JDZ-20E
20
JDZ-25E
25
JDZ-30E
30
JDZ-40E
40
JDZ-50E
50
JDZ-65E
65
JDZ-80E
80
JDZ-100E
100
JDZ-125E
125
Recommended fuseclips: see page 91 - 1A0065, 9078A67G04, A3354730
General Notes:
1. All fuses are fitted with a striker pin which can be used for indication or tripping purposes.
2. The fuses are suitable for use either indoors or outdoors.
3. These fuses are interchangeable with corresponding fuses produced by most other leading North American manufacturers.
Contact Cooper Bussmann for the latest product information on E-Rated fuses for transformer and feeder protection.
*Bolt on mounting
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
75
Medium Voltage Fuses
E-rated Fuses: CL-14 & Bolt-In
ECL055
Specifications
Description: E-rated medium voltage, current-limiting fuses
for transformer and feeder protection.
Construction: Filament wound, glass epoxy fuse tube, with
silica filler, and silver-plated copper terminals and endcaps
containing a silver element in a double concentric helical
configuration.
Ratings:
Volts: — 5.5kV
Amps: — 10-900A
IR: — 63kA Sym. Max
Agency Information: Meets E requirements per ANSI
C37.46, Meets General Purpose requirements per ANSI
C37.40.
Features and Benefits
• Clip-lock and bolt-in style available in double and triple barrel
fuse designs for application flexibility
• The filament wound, glass epoxy fuse tube provides UV and
moisture protection, making these medium voltage fuses
suitable for both indoor and outdoor applications
• Open fuse indication (indicator travel distance is 16mm)
easily integrates into automation schemes
• 50/60Hz operating frequency make these fuses applicable
world-wide
•
•
•
•
Typical Applications
5.0kV Transformer Primary Protection
5.0kV Feeder Circuit Protection
5.0kV Voltage Switches
5.0kV Metal-enclosed Switchgear
Catalog Numbers
Catalog
Numbers
ECL055-10E
ECL055-15E
ECL055-20E
ECL055-25E
ECL055-30E
ECL055-40E
ECL055-50E
ECL055-65E
ECL055-80E
ECL055-100E
ECL055-125E
ECL055-150E
ECL055-200E
ECL055-250E
ECL055-300E
ECL055-400E
ECL055-450E
ECL055-500E
ECL055-600E
ECL055-750E
ECL055-900E
Amp
Rating
10
15
20
25
30
40
50
65
80
100
125
150
200
250
300
400
450
500
600
750
900
Voltage
5.5kV
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
IR
Max Sym.
63kA
# of
Barrels
1
Style
Clip-Lock
1
Clip-Lock
2
Clip-Lock
3
Bolt-In
Bolt-In
63kA
2
3
Catalog Number Construction (Example)
Catalog Number
ECL
Voltage Rating
055
055 = 5.5 kV
Amp Rating
500E
Catalog Number Cross Reference
Cooper Bussmann
Catalog Numbers
ECL055-10E
ECL055-15E
ECL055-20E
ECL055-25E
ECL055-30E
ECL055-40E
ECL055-50E
ECL055-65E
ECL055-80E
ECL055-100E
ECL055-125E
ECL055-150E
ECL055-200E
ECL055-250E
ECL055-300E
ECL055-400E
ECL055-450E
ECL055-500E
ECL055-600E
ECL055-750E
ECL055-900E
Ferraz-Shawmut
New Catalog #
A055C1DORO-10E
A055C1DORO-15E
A055C1DORO-20E
A055C1DORO-25E
A055C1DORO-30E
A055C1DORO-40E
A055C1DORO-50E
A055C1DORO-65E
A055C1DORO-80E
A055C1DORO-100E
A055C1DORO-125E
A055C1DORO-150E
A055C1DORO-200E
A055C1DORO-250E
A055C1DORO-300E
A055C1DORO-400E
A055C2DORO-450E
A055C2DORO-500E
A055C2DORO-600E
A055B3DORO-750E
A055B3DORO-900E
Data Sheet: 9002
76
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
Ferraz-Shawmut
Old Catalog #
225-007-937
225-007-938
225-007-939
225-007-940
225-007-941
225-007-942
225-007-943
225-007-944
225-007-945
225-007-946
225-007-947
225-007-948
225-007-949
225-007-950
225-007-951
225-007-952
225-007-953
225-007-954
225-007-955
A055X750E-4
A055X900E-4
Medium Voltage Fuses
E-rated Fuses: CL-14
ECL155
Features and Benefits
• Clip-lock double barrel fuse design assures positive
installation
• The filament wound, glass epoxy fuse tube provides UV and
moisture protection, making these medium voltage fuses
suitable for both indoor and outdoor applications
• Open fuse indication (indicator travel distance is 16mm)
easily integrates into automation schemes
• 50/60 Hz operating frequency make these fuses applicable
world-wide
•
•
•
•
Typical Applications
15.0kV Transformer Primary Protection
15.0kV Feeder Circuit Protection
15.0kV Voltage Switches
15.0kV Metal-enclosed Switchgear
Catalog Numbers
Catalog
Numbers
ECL155-10E
ECL155-15E
ECL155-20E
ECL155-25E
ECL155-30E
ECL155-40E
ECL155-50E
ECL155-65E
ECL155-80E
ECL155-100E
ECL155-125E
ECL155-150E
ECL155-200E
ECL155-250E
ECL155-300E
Amp
Rating
10
15
20
25
30
40
50
65
80
100
125
150
200
250
300
Voltage
15.5kV
IR Voltage
Max Sym.
63KA
# of
Barrels
1
Style
Clip-Lock
1
63kA
15.5kV
Clip-Lock
2
50kA
50kA
2
Catalog Number Construction (Example)
Catalog Number
ECL
Voltage Rating
155
155 = 15.5 kV
Amp Rating
300E
Catalog Number Cross Reference
Cooper Bussmann
Catalog Numbers
ECL155-10E
ECL155-15E
ECL155-20E
ECL155-25E
ECL155-30E
ECL155-40E
ECL155-50E
ECL155-65E
ECL155-80E
ECL155-100E
ECL155-125E
ECL155-150E
ECL155-200E
ECL155-250E
ECL155-300E
Ferraz-Shawmut
New Catalog #
A155C1DORO-10E
A155C1DORO-15E
A155C1DORO-20E
A155C1DORO-25E
A155C1DORO-30E
A155C1DORO-40E
A155C1DORO-50E
A155C1DORO-65E
A155C1DORO-80E
A155C1DORO-100E
A155C2DORO-125E
A155C3DORO-150E
A155C3DORO-200E
A155C3DORO-250E
A155C3DORO-300E
Ferraz-Shawmut
Old Catalog #
225-007-967
225-007-968
225-007-969
225-007-970
225-007-971
225-007-972
225-007-973
225-007-974
225-007-975
225-007-976
225-007-977
225-007-978
225-007-979
225-007-980
225-007-981
Data Sheet: 9004
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
77
Medium
Voltage
Fuses
Specifications
Description: E-rated medium voltage, current-limiting fuses
for transformer and feeder protection.
Construction: Filament wound, glass epoxy fuse tube, with
silica filler, and silver-plated copper terminals and endcaps
containing a silver element in a double concentric helical
configuration.
Ratings:
Volts: — 15.5kV
Amps: — 10-300A
IR: — 63kA Sym. (10-200A)
— 50kA Sym. (250-300A)
Agency Information: Meets E requirements per ANSI
C37.46, Meets General Purpose requirements per ANSI
C37.40.
Medium Voltage Fuses
E-rated Fuses for Potential & Small Power Transformers
Features and Benefits
• Sized for retrofitting in existing hardware
• Space saving size
JCD, JCW, JCQ, JCI &
JCT
Specifications
Description: Indicating and nonindicating E-rated medium voltage,
current-limiting fuses for potential
and small power transformers.
Dimensions: See Catalog
Numbers table.
Construction: Plated ferrules.
Ratings:
Volts: — 2.4-15.5kV (See Catalog Numbers table for details)
Amps: — 1⁄2-10A
IR: — 25-80kA Sym
— 40-130kA ASYM
— See Catalog Numbers table for details
Typical Applications
• Primary protection of medium voltage potential transformers
• Primary protection of small medium voltage service
transformers
• Primary protection of small medium voltage control
transformers
Catalog Numbers
Catalog
Numbers
Amp
Rating
Maximum
Design Voltage
IR RMS Sym.
Dimensions - in (mm)
Length
Diameter
2400V; E-Rated Fuse; Non-Indicating
JCD-1⁄2E
JCD-1E
JCD-2E
JCD-5E
0.5
1
2
5
2.75kV
2.75kV
2.75kV
2.75kV
63kA
40kA
40kA
25kA
4.50
4.50
4.50
4.50
(114)
(114)
(114)
(114)
0.80
0.80
0.80
0.80
(20.32)
(20.32)
(20.32)
(20.32)
2450/5500V; E-Rated Fuse; Non-Indicating
JCW-1⁄2E
JCW-1E
JCW-2E
JCW-3E
JCW-5E
0.5
1
2
3
5
2.75/5.5kV
2.75/5.5kV
2.75/5.5kV
2.75/5.5kV
2.75/5.5kV
40kA
40kA
40kA
40kA
40kA
7.312
7.312
7.312
7.312
7.312
(185.72)
(185.72)
(185.72)
(185.72)
(185.72)
1.563
1.563
1.563
1.563
1.563
(39.70)
(39.70)
(39.70)
(39.70)
(39.70)
80kA
80kA
80kA
80kA
80kA
80kA
9.5
9.5
9.5
9.5
9.5
9.5
(241.3)
(241.3)
(241.3)
(241.3)
(241.3)
(241.3)
1.6
1.6
1.6
1.6
1.6
1.6
(40.64)
(40.64)
(40.64)
(40.64)
(40.64)
(40.64)
80kA
80kA
50kA
50kA
9.5 (241.3)
12.88 (327.15)
12.88 (327.15)
12.88 (327.15)
1.6
1.6
1.6
1.6
(40.64)
(40.64)
(40.64)
(40.64)
80kA
80kA
80kA
80kA
80kA
80kA
12.93 (328.42)
12.93 (328.42)
12.93 (328.42)
17.5 (444.5)
17.5 (444.5)
17.5 (444.5)
1.6
1.6
1.6
1.6
1.6
1.6
(40.64)
(40.64)
(40.64)
(40.64)
(40.64)
(40.64)
5500V; E-Rated Fuse; Indicating
JCQ-1⁄2E
JCQ-1E
JCQ-11⁄2E
JCQ-3E
JCQ-5E
JCQ-10E
0.5
1
1.5
3
5
10
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
8300V; E-Rated Fuse; Indicating
JCI-1⁄2E
JCI-3E
JCI-5E
JCI-10E
0.5
3
5
10
8.3kA
8.3kA
8.3kA
8.3kA
15,500V; E-Rated Fuse; Indicating
JCT-1⁄2E
JCT-1E
JCT-1-1⁄2E
JCT-3E
JCT-5E
JCT-10E
0.5
1
1.5
3
5
10
15.5kV
15.5kV
15.5kV
15.5kV
15.5kV
15.5kV
Fuse clip for 1.56 and 1.6 inch diameter fuses - 1A0835.
Fuse clip for 0.81 inch diameter fuses - 1A1837.
Data Sheet: 6002
78
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
Medium Voltage Fuses
E-rated Fuses for Potential & Small Power Transformers
Ratings:
Volts: — 5.5-38kV
Amps: — 0.5-15A
IR: — 40kA-80kA Sym.
— See Catalog Numbers table for details
AB, AD, AM and
CAV
Typical Applications
• Primary protection of medium voltage potential transformers
• Primary protection of small medium voltage service
transformers
• Primary protection of small medium voltage control
transformers
Catalog Numbers
Catalog
Numbers
Amp
Rating
5.5ABWNA0.5E
5.5ABWNA1E
5.5ABWNA2E
5.5ABWNA3E
5.5ABWNA5E
5.5AMWNA0.5E
5.5AMWNA1.0E
5.5AMWNA2.0E
5.5AMWNA3.0E
5.5AMWNA4.0E
5.5AMWNA5.0E
5.5CAVH0.5E
5.5CAVH1E
5.5CAVH2E
5.5CAV15E
7.2AMWNA0.5E
7.2AMWNA1.0E
7.2AMWNA2.0E
7.2AMWNA3.0E
7.2AMWNA4.0E
7.2AMWNA5.0E
15.5CAV(H)0.5E*
15.5CAV(H)1E*
15.5CAV(H)2E*
15.5CAV3E
15.5CAV5E
15.5CAV7E
38ADMNA7E
38ADMNA10E
38CAV(H)0.5E*
38CAV(H)1E*
38CAV(H)2E*
38CAV4E
0.5
1
2
3
5
0.5
1.5
2.5
3.5
4.5
5.5
0.5
1
2
15
0.5
1
2
3
4
5
0.5
1
2
3
5
7
7
10
0.5
1
2
4
Maximum
Design Voltage
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
7.2kV
7.2kV
7.2kV
7.2kV
7.2kV
7.2kV
15.5kV
15.5kV
15.5kV
15.5kV
15.5kV
15.5kV
38kV
38kV
38KV
38KV
38KV
38KV
IR RMS Sym.
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
63kA
63kA
63kA
63kA
50kA
50kA
50kA
50kA
50kA
50kA
80kA
80kA
80kA
80kA
80kA
80kA
40kA
40kA
40kA
40kA
40kA
40kA
Dimensions - in (mm)
Length
Diameter
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
7.375 (187.3)
7.375 (187.3)
7.375 (187.3)
7.375 (187.3)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
5.6 (142.2)
12.87 (326.9)
12.87 (326.9)
12.87 (326.9)
12.87 (326.9)
12.87 (326.9)
12.87 (326.9)
17.4 (442)
17.4 (442)
17.32 (439.9)
17.32 (439.9)
17.32 (439.9)
17.32 (439.9)
1 (25.4)
1 (25.4)
1 (25.4)
1 (25.4)
1 (25.4)
0.81 (20.6)
0.81 (20.6)
0.81 (20.6)
0.81 (20.6)
0.81 (20.6)
0.81 (20.6)
1.63 (41.4)
1.63 (41.4)
1.63 (41.4)
1.63 (41.4)
0.81 (20.6)
0.81 (20.6)
0.81 (20.6)
0.81 (20.6)
0.81 (20.6)
0.81 (20.6)
1.63 (41.4)
1.63 (41.4)
1.63 (41.4)
1.63 (41.4)
1.63 (41.4)
1.63 (41.4)
2 (50.8)
2 (50.8)
1.63 (41.4)
1.63 (41.4)
1.63 (41.4)
1.63 (41.4)
*Type CAVH fuses are fitted with a striker pin for indication. Omit ‘H’ for non-indicating fuses.
Fuseclip for 0.8 inch diameter fuses - 1A1837.
Fuseclip for 1 inch diameter fuses - A3354705.
Fuseclip for 1.6 inch diameter fuses - 1A0835.
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
79
Medium
Voltage
Fuses
Specifications
Description: Indicating and non-indicating E-rated medium
voltage, current-limiting fuses for potential and small power
transformers.
Dimensions: See Catalog Numbers table.
Features and Benefits
• Sized for retrofitting in existing hardware
• Space saving size
Medium Voltage Fuses
R-rated Fuses for Motor Circuit Protection
JCG, JCH, JCK,
JCK-A, JCK-B, JCL,
JCL-A, JCL-B, JCR-A,
& JCR-B
Specifications
Description: Indoor/enclosure
R-rated medium voltage,
current-limiting fuses for motor
circuit protection.
Dimensions: See Dimensions
illustrations.
Ratings:
Volts: — 2.4-7.2kV (See Catalog Numbers table for details)
Amps: — 25-450A (See Catalog Numbers table for details)
IR: — 50kA Sym
— 80kA ASYM
— See Catalog Numbers table for details
Agency Information: UL Recognized: 2540Vac — JCK,
JCK-A, 5080Vac — JCL, JCL-A, UL Recognized (Guide
#MSSS2, File #E96676).
Features and Benefits
• Physically dimensioned for retrofitting in existing hardware
• Open fuse indicator for ease in troubleshooting
• Available with optional Cutler Hammer® hookeye for ease of
insertion and removal
• Classified as back-up fuses for current-limited protection of
medium voltage motor controllers
Typical Applications
• Medium Voltage Motor Controllers
Dimensions - mm (in)
Figure 1
INDICATOR
Showing Fuse is Open
0.38"
(9.5mm)
C
A
INDICATOR
Showing Fuse
is Open
B
Figure 2
Figure 3
Data Sheet 6001
80
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
Medium Voltage Fuses
R-rated Fuses for Motor Circuit Protection
Catalog Numbers: R-Rated; Indoor/Enclosure
Catalog
Numbers
Amp
Ratings
Maximum
Design Voltage
A
Dimensions - in (mm)*
B
Construction
C
Max Int. Cap.
Amps (Asym.)
Amps
(Sym.)
Min Int. Cap.
Amps (Sym.)
2400V (See Figure 1)
JCK-2R
JCK-3R
JCK-4R
JCK-5R
JCK-6R
JCK-9R
JCK-12R
JCK-18R
JCK-24R
70
100
130
150
170
200
230
390
450
2540
2540
2540
2540
2540
2540
2540
2540
2540
11.24
11.24
11.24
11.24
11.24
11.24
11.24
11.24
11.24
(285.5)
(285.5)
(285.5)
(285.5)
(285.5)
(285.5)
(285.5)
(285.5)
(285.5)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
165
220
320
410
480
720
970
1,430
1,880
Single
Single
Single
Single
Single
Single
Single
Double
Double
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
165
220
320
410
480
720
970
1,430
1,880
Single
Single
Single
Single
Single
Single
Single
Single
Double
Double
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
90
170
245
340
430
500
1,000
1,250
1,700
1,210
Medium
Voltage
Fuses
Single
Single
Single
Single
Single
Single
Single
Double
Double
2400V — With Westinghouse Ampguard Hookeye (See Figure 1)
JCK-A-2R
JCK-A-3R
JCK-A-4R
JCK-A-5R
JCK-A-6R
JCK-A-9R
JCK-A-12R
JCK-A-18R
JCK-A-24R
70
100
130
150
170
200
230
390
450
2540
2540
2540
2540
2540
2540
2540
2540
2540
11.24
11.24
11.24
11.24
11.24
11.24
11.24
11.24
11.24
(285.5)
(285.5)
(285.5)
(285.5)
(285.5)
(285.5)
(285.5)
(285.5)
(285.5)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
2400V — Bolt-On (See Figures 2 & 3)
JCK-B-30
JCK-B-2R
JCK-B-3R
JCK-B-4R
JCK-B-5R
JCK-B-6R
JCK-B-9R
JCK-B-12R
JCK-B-18R
JCK-B-24R
25
70
100
130
150
170
200
230
390
450
2540
2540
2540
2540
2540
2540
2540
2540
2540
2540
14.18
14.18
14.18
14.18
14.18
14.18
14.18
14.18
14.18
14.18
(360.2)
(360.2)
(360.2)
(360.2)
(360.2)
(360.2)
(360.2)
(360.2)
(360.2)
(360.2)
12.81
12.81
12.81
12.81
12.81
12.81
12.81
12.81
12.81
12.81
(325.4)
(325.4)
(325.4)
(325.4)
(325.4)
(325.4)
(325.4)
(325.4)
(325.4)
(325.4)
3.56 (90.4)
3.56 (90.4)
2400V — Hermetically Sealed, For Use with Ampguard Motor Starters (See Figure 1)
JCH-30
JCH-2R
JCH-3R
JCH-4R
JCH-5R
JCH-6R
JCH-9R
JCH-12R
JCH-18R
JCH-24R
25
70
100
130
150
170
200
230
390
450
2540
2540
2540
2540
2540
2540
2540
2540
2540
2540
10.81
10.81
10.81
10.81
10.81
10.81
10.81
10.81
10.81
10.81
(275.6)
(275.6)
(275.6)
(275.6)
(275.6)
(275.6)
(275.6)
(275.6)
(275.6)
(275.6)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
Single
Single
Single
Single
Single
Single
Single
Single
Double
Double
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
90
170
245
340
430
500
1,000
1,250
1,700
2,100
15.76
15.76
15.76
15.76
15.76
15.76
15.76
15.76
15.76
(400.3)
(400.3)
(400.3)
(400.3)
(400.3)
(400.3)
(400.3)
(400.3)
(400.3)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
Single
Single
Single
Single
Single
Single
Single
Double
Double
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
165
220
320
410
480
720
970
1,430
1,880
4800V (See Figure 1)
JCL-2R
JCL-3R
JCL-4R
JCL-5R
JCL-6R
JCL-9R
JCL-12R
JCL-18R
JCL-24R
70
100
130
150
170
200
230
390
450
5080
5080
5080
5080
5080
5080
5080
5080
5080
• See previous page Figure 2 for single construction and Figure 3 for double construction information.
Recommended fuseclips: see page 91 - 1A0065, A3354730, 9078A67G04.
Data Sheet: 6001
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
81
Medium Voltage Fuses
R-rated Fuses for Motor Circuit Protection
Catalog Numbers: R-Rated; Indoor/Enclosure
Catalog
Numbers
Amp
Ratings
Maximum
Design Voltage
A
Dimensions - in (mm)
B
Max Int. Cap.
Amps (Asym.
Amps
(Sym.)
Single
Single
Single
Single
Single
Single
Single
Double
Double
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
165
220
320
410
480
720
970
1,430
1,880
Single
Single
Single
Single
Single
Single
Single
Single
Double
Double
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
95
180
270
350
450
540
700
1,000
1,450
2,000
Construction
C
Min Int. Cap.
Amps (Sym.)
4800V — With Westinghouse Ampguard Hookeye (See Figure 1)
JCL-A-2R
JCL-A-3R
JCL-A-4R
JCL-A-5R
JCL-A-6R
JCL-A-9R
JCL-A-12R
JCL-A-18R
JCL-A-24R
70
100
130
150
170
200
230
390
450
5080
5080
5080
5080
5080
5080
5080
5080
5080
15.76
15.76
15.76
15.76
15.76
15.76
15.76
15.76
15.76
(400.3)
(400.3)
(400.3)
(400.3)
(400.3)
(400.3)
(400.3)
(400.3)
(400.3)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
4800V — Bolt-On (See Figures 2 & 3)
JCL-B-30
JCL-B-2R
JCL-B-3R
JCL-B-4R
JCL-B-5R
JCL-B-6R
JCL-B-9R
JCL-B-12R
JCL-B-18R
JCL-B-24R
30
70
100
130
150
170
200
230
390
450
5080
5080
5080
5080
5080
5080
5080
5080
5080
5080
19.25
19.25
19.25
19.25
19.25
19.25
19.25
19.25
19.25
19.25
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
3.31 (84.1)
3.31 (84.1)
4800V — Hermetically Sealed, For Use with Ampguard Motor Starters (See Figure 1)
JCG-30
JCG-2R
JCG-3R
JCG-4R
JCG-5R
JCG-6R
JCG-9R
JCG-12R
JCG-A-18R
JCG-A-24R
30
70
100
130
150
170
200
230
390
450
5080
5080
5080
5080
5080
5080
5080
5080
5080
5080
15.91
15.91
15.91
15.91
15.91
15.91
15.91
15.91
15.91
15.91
(404.1)
(404.1)
(404.1)
(404.1)
(404.1)
(404.1)
(404.1)
(404.1)
(404.1)
(404.1)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
Single
Single
Single
Single
Single
Single
Single
Single
Double
Double
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
95
180
270
350
450
540
700
1,000
1,450
2,000
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
Single
Single
Single
Single
Single
Single
Single
Double
Double
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
160
250
325
390
500
750
1,000
1,450
2,500
Single
Single
Single
Single
Single
Single
Single
Double
Double
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
160
250
325
390
500
750
1,000
1,450
2,500
7200V — With Ampguard Hookeye (See Figure 1)
JCR-A-2R
JCR-A-3R
JCR-A-4R
JCR-A-5R
JCR-A-6R
JCR-A-9R
JCR-A-12R
JCR-A-18R
JCR-A-24R
70
100
130
150
170
200
230
390
450
8300
8300
8300
8300
8300
7200
7200
7200
7200
15.85
15.85
15.85
15.85
15.85
15.85
15.85
15.85
15.85
(402.6)
(402.6)
(402.6)
(402.6)
(402.6)
(402.6)
(402.6)
(402.6)
(402.6)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
(76.2)
7200V — Bolt-On (See Figures 2 & 3)
JCR-B-2R
JCR-B-3R
JCR-B-4R
JCR-B-5R
JCR-B-6R
JCR-B-9R
JCR-B-12R
JCR-B-18R
JCR-B-24R
70
100
130
150
170
200
230
390
450
8300
8300
8300
8300
8300
7200
7200
7200
7200
19.25
19.25
19.25
19.25
19.25
19.25
19.25
19.25
19.25
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
(488.9)
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
17.88
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
(454.1)
3.31 (84.1)
3.31 (84.1)
Recommended fuseclips: see page 91 - 1A0065, A3354730, 9078A67G04.
Data Sheet: 6001
82
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
Medium Voltage Fuses
British Standard Dimensioned IEC Fuses for
Motor Circuit Protection
The Cooper Bussmann range of motor fuses are designed to
meet the specific requirements necessary for motor
protection. During the starting cycle of direct on-line motors,
the fuse elements will reach a considerably higher
temperature than during normal operation; (this is due to the
high amount of current the motor will draw as it starts,
typically, six times its normal load current value). This results
in expansion and contraction of the fuse elements and could
cause premature operation of the fuse.
Medium
Voltage
Fuses
Cooper Bussmann motor fuses encompass an advanced
design to minimize this effect. This therefore, negates the
need to over specify the fuse rating due to high values of
motor starting current.
Cooper Bussmann motor fuses operate extremely quickly
under heavy fault currents, resulting from the time / current
characteristic. Low power dissipation ensures low
temperature rise, important in multi-tier starters for example.
Switching (arc), voltages are lower than permitted values,
therefore, 5.5kV fuses are also suitable for 4.8kV and
2.4kV circuits.
Table of Ratings
Basic Cat.
Number
3.6WJON6
3.6WDOH6
3.6WFOH6
3.6WDLSJ
3.6WFLSJ
3.6WDFHO
3.6WFFHO
3.6WKFHO
5.5VFNHA
5.5VKNHA
7.2WFNHO
7.2WKNHO
7.2WFMSJ
7.2WKMSJ
Volts
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
5.5kV
5.5kV
7.2kV
7.2kV
7.2kV
7.2kV
Breaking
Capacity
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
60kA
60kA
40kA
40kA
63kA
63kA
Amp Ratings
5, 6.3, 10, 16, 20, 25, 31.5, 40, 50
50, 63, 80, 100, 125
160, 200
50, 63, 80, 100, 125
160, 200
50, 63, 80, 100, 125
160, 200
250, 315, 355, 400
2R-6R
9R-24R
25, 31.5, 40, 50, 63, 80, 100, 125, 160
200, 224, 250, 315
25, 31.5, 40, 50, 63, 80, 125, 160
200, 224, 250, 315, 355
Catalog Number Build-A-Code
kV
Basic Catalog Number
___
_____
Dimensions - in (mm)
Length
Diameter
7.56 (192)
1.4 (35.6)
7.56 (192)
2 (50.8)
7.56 (192)
3 (76.2)
11.5 (292.1)
2 (50.8)
11.5 (292.1)
3 (76.2)
10 (254)
2 (51)
10 (254)
3 (76.2)
10 (254)
3 (76.2)
15.86 (402.8)
3 (76.2)
15.86 (402.8)
3 (76.2)
15.86 (402.8)
3 (76.2)
15.86 (402.8)
3 (76.2)
17.40 (442)
3 (76.2)
17.40 (442)
3 (76.2)
Dimensional Standard
BS 2692 (TA1) Interchangeable with GEC type K2 PA
BS 2692 (TA1) or DIN 43625
BS 2692 (TA1) or DIN 43625
DIN 43625
DIN 43625
BS 2692 (TA2)
BS 2692 (TA2)
BS 2692 (TA2)
ANSI R-rated
ANSI R-rated
BS 2692 (TA4)
BS 2692 (TA4)
DIN 43625
DIN 43625
Amps
___
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
83
Medium Voltage Fuses
DIN Dimensioned IEC Fuses for Transformer Protection
DIN Dimension Fuses
To Spec. DIN 43625
Specifications
Catalog Symbol: See Basic Catalog Numbers table.
Description: DIN dimension fuses to Specification DIN
43625 covering current-limiting fuses with performance in
compliance with IEC 60282-1. These are in accordance with
the R10 and, in some cases, the R20 series of preferred
numbers.
Dimensions: See Catalog Numbers table.
Catalog Number Build-A-Code
kV
Basic Catalog Number
___
_____
Amps
___
Volts: — See voltage associated with the Basic Catalog
Numbers in the table.
Amps: — See amp rating associated with the Basic Catalog
Numbers in the table.
IR: — See IR associated with the Basic Catalog Numbers
in the table.
Agency Information: Comply with DIN dimensional
standard DIN 43625, VDE 0670 part 4, VDE 0670 part 40Z
and with IEC 60282-1 (2005).
Features and Benefits
• DIN dimensioned for retrofitting in existing hardware
• Open fuse indicator for ease in troubleshooting
• Designed for use in IEC equipment
Typical Applications
• Medium Voltage IEC designed equipment
Catalog Numbers
kV
3.6
7.2
12
17.5
24
36
Catalog Numbers
3.6ADOSJ(amp)
3.6WDOSJ(amp)
3.6WFOSJ(amp)
3.6ADLSJ(amp)
3.6WDLSJ(amp)
3.6WFLSJ(amp)
3.6WKLSJ(amp)
7.2TDLSJ(amp)
7.2TFLSJ(amp)
7.2WKMSJ(amp)
12TDLEJ(amp)
12THLEJ(amp)
12TKLEJ(amp)
12TXLEJ(amp)*
17.5TDLSJ(amp)*
17.5TFLSJ(amp)*
17.5TDMEJ(amp)
17.5THMEJ(amp)
17.5TKMEJ(amp)
24TDMEJ(amp)
24THMEJ(amp)
24TFMEJ(amp)
24TXMEJ(amp)*
36TDQSJ(amp)
36TFQSJ(amp)
36TXQEJ(amp)*
Amp Ratings
6.3, 10, 16, 20, 25, 31.5, 40
50, 63, 80, 100, 125
160, 200
25, 40
50, 63, 80, 100, 125
160, 200
250, 315, 400
6.3, 10, 16, 20, 25, 31.5, 40, 50, 63
80, 100, 125, 160
200, 225, 250, 315, 355
6.3, 10, 16, 20, 25, 31.5, 40, 50, 63
80, 100
125
160, 200
6.3, 10, 16, 20, 25, 31.5, 40
50
6.3, 10, 16, 20, 25, 31.5, 40, 50, 63
80, 100
125
6.3, 10, 16, 20, 25, 31.5, 40, 50
63
80, 100*1
1252, 160
3.153, 6.3, 10, 16, 20, 25
31.5, 40, 50
63
Dimensions - in (mm) Diameter x Length
2.00 x 7.56 (51 x 192)
2.00 x 7.56 (51 x 192)
3.00 x 7.56 (76 x 192
2.00 x 11.50 (51 x 292)
2.00 x 11.50 (51 x 292)
3.00 x 11.50 (76 X 292)
3.00 x 11.50 (76 X 292)
2.00 x 11.50 (51 x 292)
3.00 x 11.50 (76 x 292)
3.00 x 17.41 (76 x 442)
2.00 x 11.50 (51 x 292)
2.52 x 11.50 (64 x 292)
3.00 x 11.50 (76 x 292)
3.50 x 11.50 (88 x 292)
2.00 x 11.50 (51 x 292)
3.00 x 11.50 (76 x 292)
2.00 x 17.41 (51 x 442)
2.52 x 17.41 (64 x 442)
3.00 x 17.41 (76 x 442)
2.00 x 17.41 (51 x 442)
2.52 x 17.41 (64 x 442)
3.00 x 17.41 (76 x 442)
3.46 x 17.41 (88 x 442)
2.00 x 21.16 (51 x 537)
3.00 x 21.16 (76 x 537)
3.46 x 21.16 (88 x 537)
IR RMS Sym
40kA
50kA
40kA
63kA
35.5kA
50kA
50kA
31.5kA
35.5kA
20kA
Recommended fuseclips for DIN style fuses – 270303, A3354745 see page 91.
*Not compliant with VDE 0670, part 402.
1
-IR RMS Sym is 63kA
2
-IR RMS Sym is 40kA
3
-IR RMS Sym is 20kA
Dimensions - In (mm)
Diameter
Striker In
Operated Position
0.59"
15.0mm
1.77"
45.0mm
Length
For Diameter and Length Dimensions See Table Above
84
1.02"
1.34"
34.0mm 26.0mm
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
Medium Voltage Fuses
Potential Transformer Fuses
Ratings:
E-Rated: — See single asterisk in Basic Catalog Numbers
table
Volts: — 3.6-38kV (See Basic Catalog Numbers table)
Amps: — 2-15A (See Basic Catalog Numbers table)
IR: — 25-80kA (See Basic Catalog Numbers table)
Agency Information: BS2692-1 and IEC60282-1
AB, AM and CAV
Features and Benefits
• Physically dimensioned for retrofitting in existing hardware.
• Space saving size.
Medium
Voltage
Fuses
Specifications
Description: British Standard VT fuses with low current
ratings for use in voltage transformers or operating
transformers to provide isolation of the associated system in
the event of faults in the transformer circuit.
Dimensions: See Basic Catalog Numbers table.
Typical Applications
• Medium Voltage Potential Transformers
• Small Medium Voltage Service Transformers
Basic Catalog Numbers for “AB” & “AM” Series
Basic Cat.
Numbers
3.6ABWNA
3.6ABCNA
5.5ABWNA*
5.5AMWNA*
7.2ABWNA
7.2ABCNA
12ABCNA
15.5ABFNA
17.5ABGNA
24ABGNA
36ABGNA**
Volts
3.6kV
3.6kV
5.5kV
5.5kV
7.2kV
7.2kV
12.0kV
15.5kV
17.5kV
24.0kV
36.0kV
Amp Ratings
3.15, 6.3
3.15, 6.3, 10
0.5, 1, 2, 3, 5
0.5, 1.0, 2.0, 3.0, 4.0, 5.0
3.15, 6.3
3.15, 6.3
3.15
3.15
3.15
3.15
3.15
Dimensions - in (mm)
Length
Diameter
5.6 (142.2)
1 (25.4)
7.69 (195.3)
1 (25.4)
5.6 (142.2)
1 (25.4)
5.6 (142.2)
0.81 (20.6)
5.6 (142.2)
1 (25.4)
7.69 (195.3)
1 (25.4)
7.69 (195.3)
1 (25.4)
10.00 (254)
1 (25.4)
14.13 (358.9)
1 (25.4)
14.13 (358.9)
1 (25.4)
14.13 (358.9)
1 (25.4)
Type
AB
AB
AB
AM
AB
AB
AB
AB
AB
AB
AB
IR
50KA
50KA
50KA
50KA
45KA
45KA
45KA
32KA
35KA
25KA
31.5KA
Recommended fuse clip for 1 diameter fuses – A3354705.
Basic Catalog Numbers for “CAV” Series
Basic Cat.
Number
3.6CAV
5.5CAV*
5.5CAVH*
7.2CAV
12CAV
15.5CAV*
15.5CAVH*
17.5CAV
24CAV
36CAV
36CAVH
38CAV*
38CAVH*
Volts
3.6kV
5.5kV
5.5kV
7.2kV
12kV
15.5kV
15.5kV
17.5kV
24kV
36kV
36kV
38kV
38kV
Amp
Ratings
2
15
0.5, 1, 2
2, 4, 6, 10
2
0.5, 1, 2, 3, 5, 7
0.5, 1, 2
2, 4, 6, 10
2, 3, 4
2, 4
2
4
0.5, 1, 2
Dimensions - in (mm)
Length
Diameter
8.66 (220)
1.63 (41.4)
7.375 (187.3)
1.63 (41.4)
7.375 (187.3)
1.63 (41.4)
8.66 (220)
1.63 (41.4)
8.66 (220)
1.63 (41.4)
12.87 (326.9)
1.63 (41.4)
12.87 (326.9)
1.63 (41.4)
8.66 (220)
1.63 (41.4)
13.39 (340.1)
1.63 (41.4)
17.32 (439.9)
1.63 (41.4)
17.32 (439.9)
1.63 (41.4)
17.32 (439.9)
1.63 (41.4)
17.32 (439.9)
1.63 (41.4)
IR
50KA
63KA
63KA
63KA
40KA
80KA
80KA
40KA
40KA
40KA
40KA
40KA
40KA
Type CAVH are fitted with a striker pin for indication.
* E-Rated fuses
**For clean indoor applications only.
Catalog Number Build-A-Code
kV
Basic Catalog Number
___
_____
Amps
___
Recommended Fuse Clips: 1” dia. - A3354705, 1.63” dia. - 1A0835, .819 dia. - 1A1837
Contact Cooper Bussmann for complete specifications on potential transformer fuses
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
85
Medium Voltage Fuses
British Standard IEC Fuses for Use in Oil Filled
Distribution Switchgear
OEFMA
Code Number Reference
Specifications
Description: BS 2692-1 medium
voltage fuses for use on the primary
circuit of three-phase 50Hz
transformers in oil field switchgear.
Fitted with powerful pyrotechnic
striker pin.
Ratings:
Volts: — 3.6-24kV
Amps: — 6.3-200A
IR: — 25-50kA (See Catalog Number table below)
Agency Information: Fuses comply with IEC 60282-1,
BS2692-1 and ESI Standard 12-8. 7.2 and 12kV fuses tested
at highest system voltage and approved by the UK Electricity
Association approvals panel.
O
_
_
M
A
Type
O = Oil tight
Diameter
E = 63.5mm
H = 63.5mm
L = 63.5mm
Length
F = 254mm
G = 359mm
Striker
M = As specified in BS 2692 table 11
Tags
A = None (plain caps)
Dimensions:
Current-limiting fuse for use in oil switchgear
Featues and Benefits
• Physically sized for replacement of British Standard fuse
links
Fuse types: OEF, OEG, OHF, OHG, OLG
254mm (10 in) or 359mm (14 in)
68 Max
63.5
44
Typical Applications
• Medium Voltage BS Designed Equipment
10 Min — 16 Max striker travel after operation, if fitted.
Catalog Numbers
Transformer
kVA
200
250
300/315
400
500
630
750/800
1000
1250
1600
Catalog Numbers/Transformer Primar y Voltage
3.3kV
3.6OEFMA63
3.6OEFMA80
3.6OEFMA100
3.6OEFMA125
3.6OEFMA160
3.6OEFMA200
3.6OLGMA250
3.6OLGMA250*
—
—
6.6kV
12OEFMA31.5
12OEFMA40
12OEFMA50
12OEFMA63
12OHFMA71
7.2OEFMA100
7.2OHGMA125
7.2OHGMA140
7.2OHGMA160*
—
11kV/ESI 12-8 Ref.
12OEFMA25/01
12OEFMA25/—
12OEFMA31.5/02
12OEFMA40/—
12OEFMA50/03
12OEFMA63/—
12OHFMA80/04
12OHGMA90**/05
12OHGMA100/—
12OLGMA125*/—
13.8kV
15.5OEFMA16
15.5OEFMA20
15.5OEFMA25
15.5OEFMA31.5
15.5OEFMA40
15.5OEFMA50
15.5OEFMA63
15.5OHGMA71
15.5OHGMA90
15.5OLGMA100*
This Catalog Number selection table is based upon the following criteria:
1. Withstand against magnetizing inrush current taken as 12 times full-load current for 0.1 second.
2. Withstand against 150% permissible overload current. Recommendations marked with asterisks have the following significance:*Limited to permissible overloads of 130%.
**Permits use of a 12kV OHFMA 80A fuse with a 100kVA transformer where permissible overload does not exceed 130%.
3. For 6.6kV systems, 12kV fuses are recommended where possible in the interests of standardization.
4. Wherever possible, 10 inch long FO1 fuses are offered rather than equivalent 14 inch FO2 types.
5. The above recommendations are not generally applicable to transformers feeding motor circuits with starting currents in excess of the transformer full load current. In this event, please consult
Cooper Bussmann.
Catalog Numbers
Basic Cat.
Number
3.6OEFMA
3.6OEGMA
3.6OLGMA
7.2OEFMA
7.2OHGMA
12OEFMA
12OHFMA
12OHGMA
12OLGMA
15.5OEFMA
15.5OHGMA
15.5OLGMA
17.5OHGMA
24OEGMA
Voltage
3.6kV
3.6kV
3.6kV
7.2kV
7.2kV
12.0kV
12.0kV
12.0kV
12.0kV
15.5kV
15.5kV
15.5kV
17.5kV
24.0kV
Dimensional
Ref. BS 2692
FO1
FO2
FO2
FO1
FO2
FO1
FO1
FO2
FO2
FO1
FO2
FO2
FO2
FO2
Amp Ratings
6.3, 10, 16, 20, 25,
100, 125, 160, 200
250
80, 100, 112
125, 140, 160
6.3, 10, 16, 20, 25,
71, 80
6.3, 10, 16, 20, 25,
125
6.3, 10, 16, 20, 25,
71, 80, 90
100
6.3, 10, 16, 20, 25,
6.3, 10, 16, 20, 25,
Breaking
Capacity (kA)
31.5, 40, 50, 63, 80, 100, 125, 160, 200
50
50
50
45
45
31.5, 40, 50, 63
40
40
31.5, 40, 50, 63, 71, 80, 90, 100
40
40
31.5, 40, 50, 63
40
40
40
31.5, 40, 50, 63, 80
35
31.5, 40, 50
25
Catalog Number Build-A-Code
kV
Basic
Amps
Catalog Number
___
_____
Contact Cooper Bussmann for complete specifications on medium voltage fuses.
86
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
___
Medium Voltage Fuses
Fast-acting Fuses
HVA, HVB,
HVJ, HVL,
HVR, HVT,
HVU, HVW &
HVX
Test Specifications
Basic Catalog
Numbers
HVA, HVB, HVJ, HVL
HVR, HVT, HVU, HVW, HVX
Load / Opening Time
110% / 4 Hours (min)
135% / 1 Hour (max)
100% / 4 Hours (min)
150% / 1 Hour (max)
Features and Benefits
• Physical size varies with electrical rating of fuse to prevent
over-fusing.
• Space saving size.
Typical Applications
• Medium Voltage Instrument Protection
• Medium Voltage Circuit Protection
Medium
Voltage
Fuses
Specifications
Description: Medium voltage, non-time delay, fast-acting
fuses.
Dimensions: See Basic Catalog Numbers table.
Ratings:
Volts: — 1-10kV (See Basic Catalog Numbers table)
Amps: — 1⁄16-10A (See Basic Catalog Numbers table)
Fuse blocks: 4528, 4529, 4530 & 2960
Voltage Rating: 1000 to 10,000V
Basic Catalog
Numbers
HVA, HVR
HVB, HVT
HVJ, HVU
HVL, HVX
Fuse Block
Catalog Number
4528
4529
4530
2960
Fuse Clip
Catalog Number
5960
5960
4180
4180
Use #8 screws on blocks 4528 and 4529.
Use #10 screws on blocks 4530 and 2960.
Basic
Catalog
Number
HVA
kV
1
HVB
HVJ
HVL
HVR
HVW
HVT
HVU
HVX
2.5
5
10
1
1.2
2.5
5
10
Amp Ratings
1
⁄16, 1⁄10, 1⁄8, 2⁄10, 1⁄4, 3⁄10, 3⁄8, 1⁄2,
3
⁄4, 1, 1 1⁄2, 2, 3, 4, 6, 10
1
⁄2, 3⁄4, 1, 1 1⁄2, 2, 3
1
⁄16, 1⁄8, 1⁄4, 1⁄2, 3⁄4, 1 1⁄2, 2, 4, 6, 10
1
⁄16, 1⁄8, 1⁄4, 1⁄2, 1, 1 1⁄2, 2, 3
1
⁄2, 1, 2, 3, 4, 5
1, 2, 3, 4, 5, 8
1
⁄2, 1, 2, 3, 5
1
⁄2, 1, 2, 3, 4, 5
1
⁄2, 1, 3, 5
Maximum S.C.
20kW dc/30kVA ac
Dimensions - in (mm)
Diameter
Length
0.41 (10.4)
3 (76.1)
20kW dc/30kVA ac
20kW dc/30kVA ac
20kW dc/30kVA ac
kVA-500 ac only
kVA-12,000 ac only
kVA-1250 ac only
kVA-2500 ac only
kVA-5,000 ac only
0.41
0.81
0.81
0.41
0.41
0.41
0.81
0.41
(10.4)
(20.6)
(20.6)
(10.4)
(10.4)
(10.4)
(20.6)
(10.4)
4.5 (114.2)
5 (126.9)
10 (254)
3 (76.2)
2.25 (57.1)
4.5 (114.2)
5 (126.9)
10.0 (253.8)
Catalog Number Build-A-Code
Basic Catalog Number
Amps
_____
___
Data Sheet: 6003
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
87
Medium Voltage Fuses
EEI-NEMA Type K & T and Type H & N
FL: Type H and
EEI-NEMA Type K
& T Fuses
Catalog Numbers
EEI-NEMA and High-Surge Universal Tin Element
Fuses for Cutouts — Rated to 27kV
Non-Removable Button-Head For Standard Open or Enclosed Cutouts
Specifications
Description: Medium
voltage fuses: Type H
(high surge), EEI-NEMA
Type K (fast-acting),
EEI-NEMA Type T
(slow-acting).
Ratings:
Amps: — 1-200A
(See Catalog
Numbers tables)
Features and Benefits
• Wide range of EEI-NEMA type fuse links for use in open fuse
cutouts
• Voltage ratings up to 27kV.
• Can be coordinated with other overcurrent protective devices
for sectionalizing to isolate feeder branches.
Typical Applications
• Medium Voltage Fused Cutouts
High-Surge Type H Fuses
High-surge, Type H fuses are manufactured in ratings of 1, 2,
3, 5, and 8A. They have been developed principally for
primary fusing of small-sized transformers. Type H links are
manufactured in the universal buttonhead design.
Type N Fuses
Type N fuses conform to previous NEMA standards and have
been superseded by Type K and T links. Type N fuses are
manufactured in the universal button design in ratings of 5
through 200A for use in NEMA standard dimensioned cutouts
rated through 27kV.
Catalog Numbers
Type H
EEI-NEMA
(High
Type K
Surge)
(Fast)
FL11H1
FL11K1
FL11H2
FL11K2
FL11H3
FL11K3
FL11H5
FL11K5
—
FL11K6
FL11H8
FL11K8
—
FL11K10
—
FL11K12
—
FL11K15
—
FL11K20
—
FL11K25
—
FL11K30
—
FL11K40
—
FL11K50
—
FL11K65
—
FL11K80
—
FL11K100
—
FL11K140
—
FL11K200
EEI-NEMA
Type T
(Slow)
FL11T1
FL11T2
FL11T3
FL11T5
FL11T6
FL11T8
FL11T10
FL11T12
FL11T15
FL11T20
FL11T25
FL11T30
FL11T40
FL11T50
FL11T65
FL11T80
FL11T100
FL11T140
FL11T200
Amps
1
2
3
5
6
8
10
12
15
20
25
30
40
50
65
80
100
140
200
Removable Button-Head For Cutouts Requiring Removable-Button Links
Catalog Numbers
EEI-NEMA
EEI-NEMA
Type K
Type T
(Fast)
(Slow)
FL3K1
FL3T1
FL3K2
FL3T2
FL3K3
FL3T3
FL3K5
FL3T5
FL3K6
FL3T6
FL3K8
FL3T8
FL3K10
FL3T10
FL3K12
FL3T12
FL3K15
FL3T15
FL3K20
FL3T20
FL3K25
FL3T25
FL3K30
FL3T30
FL3K40
FL3T40
FL3K50
FL3T50
FL3K65
FL3T65
FL3K80
FL3T80
FL3K100
FL3T100
FL3K140
FL3T140
FL3K200
FL3T200
Amps
1
2
3
5
6
8
10
12
15
20
25
30
40
50
65
80
100
140
200
Adapter-type removable-button links with ferrule adapter to convert to double-leader
links are available in K and T types. Order by description.
EEI-NEMA Type K Universal Silver-Element Fuses
for Cutouts — Rated through 27kV
Non-Removable Button-Head For Standard Open or Enclosed Cutouts
Catalog Numbers
EEI-NEMA
Type K
Amps
FL12K8
8
FL12K10
10
FL12K12
12
FL12K15
15
FL12K25
25
FL12K50
50
88
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
Medium Voltage Fuses
BBU Boric Acid Fuses
BBU
is designed to operate. Its
dielectric withstand level
corresponds to insulation levels
of power class equipment, thus
the name “power fuse.”
Maximum voltage ratings for
BBU fuses are: 17kV, 27kV and
38kV.
Amps:— The continuous amp rating of a
BBU fuse should equal or
exceed the maximum load
current where the fuse is
applied. They are designed to
carry their rated continuous
current without exceeding the
temperature rise outlined in
NEMA and ANSI standards. The
BBU is available with
continuous current ratings up to
200 amps The current ratings
carry an “E” designation as
defined by ANSI and NEMA.
For example, the current
responsive element rated 100E
amps or below will melt in 300
seconds at an RMS current
within the range of 200 to 240
percent of the continuous
current ratings. Above 100E
amps, melting takes place in
600 seconds at an RMS current
within the range of 220 to 264
percent of the continuous
current rating.
IR:—
BBU fuses have interrupting
capabilities from 10kA to 14kA
symmetrical.
Features and Benefits
• Voltage ratings of up to 38kV coupled
with ratings to 200A provide a wide
range of circuit protection.
• Time-current characteristics allow for
easier coordination with downstream
devices.
• Provides replacement of a variety of
existing systems.
Typical Applications
• Power and Distribution Transformer
Protection
• Medium Voltage Feeder Circuit
Protection
• Distribution Transformers
• Medium Voltage Metal-enclosed
Switchgear
• Medium Voltage Pad-mounted Switches
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
89
Medium
Voltage
Fuses
that elongate the arc through a boric
acid chamber upon release by the fuse
Specifications
element to interrupt short circuits within
Description: Boric
one-half cycle and prevent the arc from
acid fuses for power
re-striking after a current zero.
transformers, feeder
BBU End Fittings: BBU end fittings
circuits, distribution
complete the electrical connection
transformers, metalbetween the fuse unit and the fuse
enclosed and padmounting. Positioned on the top and
mounted switchgear
bottom of the fuse, unit end fittings can
Construction:
be used over again if they remain
Principle parts of the
undamaged. They are completely
replaceable BBU fuse
interchangeable with other
unit are shown in the
manufacturers’ equivalent fuse units and
cross section views. A
mountings.
glass epoxy tube
Indoor Fittings: The indoor end fittings
encloses the assembly
are made of high-impact plastic and
containing the silver
high-conducting copper alloy. The blown
fuse element, arcing
fuse indicator, located on the top end
rod, boric acid cylinder
fitting, provides visual indication of a
and spring. Using a
faulted fuse unit. When engaged into the
pure silver element and nichrome wire
mounting, the spring-loaded plastic
strain element makes the BBU less
mounting handle actuates the latch
susceptible to failure caused by vibration,
mechanism and readily accepts a
corona corrosion and fuse element
hookstick to install or remove the
aging. The components are housed in a
assembled fuse unit.
fiberglass reinforced resin tube with
The bottom indoor fitting is threaded to
plated copper contacts. BBU fuses can
accept a muffler constructed of a plated
directly replace competitive equivalent
steel housing, containing copper mesh
units.
screening, that absorbs and contains the
noise and exhaust materials during a
fault condition, and prevents
contamination of indoor components and
mechanisms located within the
switchgear. Containment also prevents
accidental flash-over from phase-tophase or phase-to-ground by limiting
airborne particles and gases.
BBU Melt Curve Constructions: The
BBU fuse is offered in three
constructions to meet specific melt
curves for an application. The
construction is designated in the Catalog
Number suffix as follows;
• E (Standard)
• K (Fast), and
• SE (Slow)
Element
Vapor
Rod withdraws,
The curves for the SE construction are
Melts
elongating arc quenches
less inverse and allow for more of a
and vaporizing arc at first
Boric Acid current zero
time-delay at high currents. Consult
Cooper Bussmann for application
Operation: The BBU fuse uses boric
assistance.
acid to create the de-ionizing action to
Ratings:
interrupt the arc. At high temperatures,
Volts:
— The maximum voltage rating of
boric acid decomposes to produce a
the BBU fuse is the highest
blast of water vapor and inert boric
RMS voltage at which the fuse
anhydride. Fault interruption is achieved
by an arcing rod and a charged spring
Medium Voltage Fuses
BBU Boric Acid Fuses for Indoor Use
Catalog
Numbers*
BBU17-3K
BBU17-6K
BBU17-8K
BBU17-10K
BBU17-12K
BBU17-15K
BBU17-20K
BBU17-25K
BBU17-30K
BBU17-40K
BBU17-50K
BBU17-65K
BBU17-80K
BBU17-100K
BBU17-140K
BBU17-200K
BBU17-5E
BBU17-7E
BBU17-10E
BBU17-13E
BBU17-15E
BBU17-20E
BBU17-25E
BBU17-30E
BBU17-40E
BBU17-50E
BBU17-65E
BBU17-80E
BBU17-100E
BBU17-125E
BBU17-150E
BBU17-175E
BBU17-200E
BBU17-15SE
BBU17-20SE
BBU17-25SE
BBU17-30SE
BBU17-40SE
BBU17-50SE
BBU17-65SE
BBU17-80SE
BBU17-100SE
BBU17-125SE
BBU17-150SE
BBU17-175SE
BBU17-200SE
Amps
3
6
8
10
12
15
20
25
30
40
50
65
80
100
140
200
5
7
10
13
15
20
25
30
40
50
65
80
100
125
150
175
200
15
20
25
30
40
50
65
80
100
125
150
175
200
Fuse
Type
K
K
E
E
SE
SE
Voltage
kV
17
Max Int.
kA Sym
14
17
14
17
14
17
17
14
14
17
14
Catalog
Numbers*
BBU27-3K
BBU27-6K
BBU27-8K
BBU27-10K
BBU27-12K
BBU27-15K
BBU27-20K
BBU27-25K
BBU27-30K
BBU27-40K
BBU27-50K
BBU27-65K
BBU27-80K
BBU27-100K
BBU27-140K
BBU27-200K
BBU27-5E
BBU27-7E
BBU27-10E
BBU27-13E
BBU27-15E
BBU27-20E
BBU27-25E
BBU27-30E
BBU27-40E
BBU27-50E
BBU27-65E
BBU27-80E
BBU27-100E
BBU27-125E
BBU27-150E
BBU27-175E
BBU27-200E
BBU27-15SE
BBU27-20SE
BBU27-25SE
BBU27-30SE
BBU27-40SE
BBU27-50SE
BBU27-65SE
BBU27-80SE
BBU27-100SE
BBU27-125SE
BBU27-150SE
BBU27-175SE
BBU27-200SE
Amps
3
6
8
10
12
15
20
25
30
40
50
65
80
100
140
200
5
7
10
13
15
20
25
30
40
50
65
80
100
125
150
175
200
15
20
25
30
40
50
65
80
100
125
150
175
200
* BBU Melt Curve Constructions: The BBU fuse is offered in three constructions to meet
specific melt curves for an application. The construction is designated in the Catalog Number
suffix: E (Standard), K (Fast) and SE (Slow). Contact Cooper Bussmann for application
details.
Fuse
Type
K
Voltage
kV
27
Max Int.
kA Sym.
12.5
K
27
12.5
E
27
E
SE
SE
12.5
27
27
12.5
12.5
27
12.5
Catalog
Numbers
BBU38-3K
BBU38-6K
BBU38-8K
BBU38-10K
BBU38-12K
BBU38-15K
BBU38-20K
BBU38-30K
BBU38-40K
BBU38-50K
BBU38-65K
BBU38-80K
BBU38-100K
BBU38-140K
BBU38-200K
BBU38-5E
BBU38-7E
BBU38-10E
BBU38-13E
BBU38-15E
BBU38-20E
BBU38-25E
BBU38-30E
BBU38-40E
BBU38-50E
BBU38-65E
BBU38-80E
BBU38-100E
BBU38-125E
BBU38-150E
BBU38-175E
BBU38-200E
BBU38-15SE
BBU38-20SE
BBU38-25SE
BBU38-30SE
BBU38-40SE
BBU38-50SE
BBU38-65SE
BBU38-80SE
BBU38-100SE
BBU38-125SE
BBU38-150SE
BBU38-175SE
BBU38-200SE
Amps
3
6
8
10
12
15
20
30
40
50
65
80
100
140
200
5
7
10
13
15
20
25
30
40
50
65
80
100
125
150
175
200
15
20
25
30
40
50
65
80
100
125
150
175
200
Fuse
Type
K
K
E
Voltage
kV
38
38
38
E
SE
SE
90
38
38
Note: Muffler can be ordered separately. Order Catalog number BBU-MFLR.
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
10
38
End Fitting Detail
Data Sheet: 1123
10
10
Application Notes
Low currents, usually referred to as overload currents, must
be considered as BBU fuses have a rather low thermal
capacity. They cannot carry overloads of the same
magnitude/duration as motors and transformers of equal
continuous currents. For this reason, the BBU fuse must be
sized with the full load current in mind so the fuse does not
open on otherwise acceptable overloads and inrush
conditions. Coordination should be considered to help
determine what type of fuse is applied. The BBU fuse
interrupts at a natural current zero in the current wave and
allows a minimum of a half-cycle of fault current to flow
before the fault is cleared. The time-current characteristics
associated with a BBU fuse has a rather gradual slope
making it easier to coordinate with downstream equipment.
In addition, the BBU is ideal for higher voltage (up to 38kV)
and high current applications (up to 200A). It is important to
examine the minimum melting and total clearing time-current
characteristics of this fuse.
Max Int.
kA Sym.
10
10
10
Medium Voltage Fuses
Fuseclips for Medium & High Voltage Fuses
Recommended Fuseclips for Medium Voltage Fuses
Catalog
Numbers
A3354710
A3354730
A3354745
Fuse
Diameter in (mm)
2 (50.8)
3 (76)
1.77 (45)
A
3.749
4.139
3.50
B
1.979
2.449
2.50
Clip Dimensions (in)
C
D
E
2.009 1.189 4.539
3.009 1.189 5.639
1.77
1.19
4.50
F
1.509
1.509
1.50
G
0.399
0.399
0.38
C
A
G
Fuseclips are for single barrel applications only. Are not sold in pairs.
F
E
D
B
270303
DIN Fuseclip
A
Medium
Voltage
Fuses
1A0065
3” Diameter Clip
0.99"
25.0mm
4.06"
103mm
A
0.43"
10.8mm
9078A67G04
3” Diameter Clip
2 Cup assemblies per package.
Dimensions shown are for reference only.
For detailed information, visit the Electrical IEC section at www.cooperbussmann.com
91
92