AZ AZ2505 120 AMP LATCHING POWER RELAY FEATURES • • • • • • • Low cost 120 Amp switching Heavy loads to 30000 VA 4 kV dielectric Single or Dual Coil Latching available Multiple Termination Options UL pending CONTACTS GENERAL DATA Arrangement SPST-NO (1 Form A) SPST-NC (1 Form B) Ratings Resistive load: Rated Load UL, CUR Life Expectancy Mechanical Electrical Minimum operations 1 x 106 1 x 104 at 60 A, 250 VAC Res. Max. switched power: 30000 VA Max. switched current: 120 A Max. switched voltage: 250 VAC Set Time (max) 20 ms at nominal coil voltage Reset Time (max) 20 ms at nominal coil voltage 60 A at 250 VAC 80 A at 250 VAC 100 A at 250 VAC 120 A at 250 VAC Dielectric Strength 4000 VAC coil to contact (at sea level for 1 min.) 1500 VAC between open contacts Material silver alloy Resistance < 2 milliohms initially (6 V, 1 A voltage drop method) COIL 1000 megohms min. at 500 VDC Ambient Temperature Operating Storage At nominal coil voltage -40°C (-40°F) to 85°C (194°F) -40°C (-40°F) to 90°C (194°F) Vibration 0.059" DA at 10–55 Hz Operating Humidity 20 - 85%RH (non-condensing) Shock Power At Pickup Voltage (typical) Insulation Resistance Operating 10 g Non-Operating 100 g 563 mW Single Coil 1.125 W Dual Coil NOTES 1. All values at 23°C (73.4°F). Enclosure P.B.T. polyester Terminals Quick connect terminal Max. Solder Temp. 270°C (518°F) Max. Solder Time 5 seconds Weight 50 grams 2. Relay may pull in with less than “Must Operate” value. 3. Specifications subject to change without notice. 4. Allow suitable slack on leads when wiring, and do not subject the terminals to excessive force. 11/20/2014 AZ AZ2505 RELAY ORDERING DATA COIL SPECIFICATIONS -Single Coil Nominal Coil VDC 5 6 9 12 24 ORDER NUMBER Set Voltage Reset Voltage Max. Continuous VDC VDC VDC[1] 3.75 4.0 6.5 4.50 4.8 7.8 6.75 7.2 11.7 9.00 9.6 15.6 18.00 19.2 31.2 Coil Resistance ± 10% 25 36 81 144 576 1 Form A 1 Form B AZ2505P1–1A–5D AZ2505P1–1A–6D AZ2505P1–1A–9D AZ2505P1–1A–12D AZ2505P1–1A–24D AZ2505P1–1B–5D AZ2505P1–1B–6D AZ2505P1–1B–9D AZ2505P1–1B–12D AZ2505P1–1B–24D Add suffix ‘E’ after A or B for 80A contacts, ‘H’ for 100A contacts, or ‘T’ for 120A contacts. Add Termination Suffix as seen in Chart below. Note[1]: Max continuous voltage should not be applied for more than 30 seconds. COIL SPECIFICATIONS -Dual Coil Nominal Coil VDC 5 6 9 12 24 ORDER NUMBER Set Voltage Reset Voltage Max. Continuous VDC VDC VDC[1] 3.75 4.0 6.5 4.50 4.8 7.8 6.75 7.2 11.7 9.00 9.6 15.6 18.00 19.2 31.2 Coil Resistance ± 10% 12.5 + 12.5 18 + 18 40.5 + 40.5 72 + 72 288 + 288 1 Form A 1 Form B AZ2505P2–1A–5D AZ2505P2–1A–6D AZ2505P2–1A–9D AZ2505P2–1A–12D AZ2505P2–1A–24D AZ2505P2–1B–5D AZ2505P2–1B–6D AZ2505P2–1B–9D AZ2505P2–1B–12D AZ2505P2–1B–24D Add suffix ‘E’ after A or B for 80A contacts, ‘H’ for 100A contacts, or ‘T’ for 120A contacts. Add Termination suffix as seen in chart below. Note[1]: Max continuous voltage should not be applied for more than 30 seconds. TERMINATION OPTIONS MS MH MC WHS WHH CH Stationary Contact: Shunt Stationary Contact: Shunt Stationary Contact: Shunt Stationary Contact: Tab Stationary Contact: Tab Stationary Contact: Tab Moveable Contact: Lead Wire Moveable Contact: Tab Moveable Contact: Shunt Moveable Contact: Lead Wire Moveable Contact: Tab Moveable Contact: Shunt WSS WSH CS *PCB Stationary Contact: Lead Wire Stationary Contact: Lead Wire Stationary Contact: Lead Wire Printed Circuit Board Moveable Contact: Lead Wire Moveable Contact: Tab Moveable Contact: Shunt Tin Plated Terminals * Only available in 60A, 80A, and 100A version MECHANICAL DATA Single Coil Dual Coil Termination Type MS 11/20/2014 AZ2505 Single Coil Dual Coil Termination Type MH Dual Coil Single Coil Termination Type WSS Load Current Tab Thickness(T) 60A 1.0mm 80A 1.5mm 100A 2.0mm 120A 2.5mm 11/20/2014 Dual Coil Termination Type PCB Wiring Diagram pin 1 5 6 pin 1 pin 3 5 6 pin 2 pin 3 NOTE: 1. Single Coil Latching Version (1). After energizing Pin 3(+) and Pin 1(-), 50 ms pulse, Terminal 5 and 6 is conncected. (2). After energizing Pin 1(+) and Pin 3(-), 50 ms pulse, Terminal 5 and 6 is diconncected. 1. Double Coil Latching Version (1). After energizing Pin 2(+) and Pin 1(-), 50 ms pulse, Terminal 5 and 6 is conncected. (2). After energizing Pin 2(+) and Pin 3(-), 50 ms pulse, Terminal 5 and 6 is diconncected. 11/20/2014